Cisco 350-601 Practice Test 23
Question 220
An administrator creates an ACI VMM integration, but dynamic port groups and VM endpoint attachment are not synchronized. The observed failure is: a missing EPG-to-VMM association leaves VM workloads without the intended policy-controlled connectivity. What should the engineer do to recover and validate the service?
- The controlled remediation is to create only an FC zoneset to attach VMware port groups.
- The controlled remediation is to map every VM to an unrelated VLAN by modifying host BIOS.
- The controlled remediation is to disable vCenter communication while expecting automated VMM updates.
- The controlled remediation is to restore the VMM controller connection and EPG association and validate deployment of expected port groups.
Explanation
Correct Answer
D:ACI VMM integration coordinates virtual networking inventory and EPG policy placement with the hypervisor manager. Validate against aPIC VMM credentials and controller status, dynamic port groups, EPG domain mapping, and learned VM endpoints.
Incorrect Answers
A:Create only an FC zoneset to attach VMware port groups. This would not reliably restore service after the stated fault. A missing EPG-to-VMM association leaves VM workloads without the intended policy-controlled connectivity. The controlled recovery is to restore the VMM controller connection and EPG association and validate deployment of expected port groups.
B:Map every VM to an unrelated VLAN by modifying host BIOS. This would not reliably restore service after the stated fault. A missing EPG-to-VMM association leaves VM workloads without the intended policy-controlled connectivity. The controlled recovery is to restore the VMM controller connection and EPG association and validate deployment of expected port groups.
C:Disable vCenter communication while expecting automated VMM updates. This would not reliably restore service after the stated fault. A missing EPG-to-VMM association leaves VM workloads without the intended policy-controlled connectivity. The controlled recovery is to restore the VMM controller connection and EPG association and validate deployment of expected port groups.
Question 221
Two ACI endpoint groups have valid interfaces but cannot route because the bridge-domain subnet gateway is not configured. Which operator action best meets this technical requirement?
- Validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain.
- Add the same ambiguous subnet to unrelated tenant VRFs without design control.
- Modify only the endpoint naming convention.
- Expect a Cisco UCS service profile to install an ACI gateway automatically.
Explanation
Correct Answer
A:This directly addresses ACI bridge domain subnet and VRF because ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. Confirm the change against aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
Incorrect Answers
B:A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The relevant correction is to validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain.
C:Modify only the endpoint naming convention. The proposed change targets the wrong mechanism or lacks essential validation. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. Relevant evidence is aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
D:A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The appropriate action remains to validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain.
Question 222
Two ACI endpoint groups have valid interfaces but cannot route because the bridge-domain subnet gateway is not configured. Which collection of observations most directly tests the suspected cause?
- An up management interface without the relevant routing or forwarding table.
- APIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
- A pre-change network diagram with no live control-plane state.
- An interface description without the effective peer or VXLAN policy.
Explanation
Correct Answer
B:These observations test the actual ACI bridge domain subnet and VRF mechanism rather than a superficial management status. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
Incorrect Answers
A:An up management interface without the relevant routing or forwarding table. This information cannot independently verify ACI bridge domain subnet and VRF. The decisive records instead include aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
C:A pre-change network diagram with no live control-plane state. This information cannot independently verify ACI bridge domain subnet and VRF. The decisive records instead include aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
D:An interface description without the effective peer or VXLAN policy. This information cannot independently verify ACI bridge domain subnet and VRF. The decisive records instead include aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
Question 223
Two ACI endpoint groups have valid interfaces but cannot route because the bridge-domain subnet gateway is not configured. Which statement most accurately explains this scenario?
- A working management-plane ping proves every tenant and application path is healthy.
- A device description always determines actual forwarding policy regardless of running configuration.
- ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
- Physical link carrier guarantees all overlay and routing states are correct.
Explanation
Correct Answer
C:This explains why the most appropriate response is to validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain. Validation depends on aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
Incorrect Answers
A:A working management-plane ping proves every tenant and application path is healthy. This is an incorrect generalization for ACI bridge domain subnet and VRF. The applicable technical behavior is that ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. The operator should verify aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
B:A device description always determines actual forwarding policy regardless of running configuration. This is an incorrect generalization for ACI bridge domain subnet and VRF. The applicable technical behavior is that ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. The operator should verify aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
D:Physical link carrier guarantees all overlay and routing states are correct. This is an incorrect generalization for ACI bridge domain subnet and VRF. The applicable technical behavior is that ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. The operator should verify aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
Question 224
Two ACI endpoint groups have valid interfaces but cannot route because the bridge-domain subnet gateway is not configured. Assume an engineer instead chooses to add the same ambiguous subnet to unrelated tenant VRFs without design control. What is the principal technical consequence of the mistaken choice?
- The defect exists solely because the engineer documented the change.
- Preserving neighbor-state evidence is itself the source of the observed outage.
- Investigating the forwarding table is the reason a broken route cannot converge.
- A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment.
Explanation
Correct Answer
D:ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual ACI bridge domain subnet and VRF defect after the shortcut. The meaningful failure is that a missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment.
B:This does not explain the actual ACI bridge domain subnet and VRF defect after the shortcut. The relevant evidence is aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
C:This does not explain the actual ACI bridge domain subnet and VRF defect after the shortcut. Investigating the forwarding table is the reason a broken route cannot converge.
Question 225
Two ACI endpoint groups have valid interfaces but cannot route because the bridge-domain subnet gateway is not configured. The observed failure is: a missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. What should the engineer do to recover and validate the service?
- Fix the BD subnet and routing association and verify tenant reachability under permitted contracts.
- Modify only the endpoint naming convention.
- Expect a Cisco UCS service profile to install an ACI gateway automatically.
- Add the same ambiguous subnet to unrelated tenant VRFs without design control.
Explanation
Correct Answer
A:ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:Modify only the endpoint naming convention. This would not reliably restore service after the stated fault. A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The controlled recovery is to fix the BD subnet and routing association and verify tenant reachability under permitted contracts.
C:Expect a Cisco UCS service profile to install an ACI gateway automatically. This would not reliably restore service after the stated fault. A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The controlled recovery is to fix the BD subnet and routing association and verify tenant reachability under permitted contracts.
D:Add the same ambiguous subnet to unrelated tenant VRFs without design control. This would not reliably restore service after the stated fault. A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The controlled recovery is to fix the BD subnet and routing association and verify tenant reachability under permitted contracts.
Question 226
A newly deployed application subnet is associated with an EPG but lacks the expected Layer 3 gateway under its bridge domain. Which next step should the data center engineer select?
- On this affected device, the engineer should modify only the endpoint naming convention.
- On this affected device, the engineer should validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain.
- On this affected device, the engineer should expect a Cisco UCS service profile to install an ACI gateway automatically.
- On this affected device, the engineer should add the same ambiguous subnet to unrelated tenant VRFs without design control.
Explanation
Correct Answer
B:This directly addresses ACI bridge domain subnet and VRF because ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
Incorrect Answers
A:Modify only the endpoint naming convention. The proposed change targets the wrong mechanism or lacks essential validation. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. Relevant evidence is aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
C:A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment.
D:A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. Add the same ambiguous subnet to unrelated tenant VRFs without design control.
Question 227
A newly deployed application subnet is associated with an EPG but lacks the expected Layer 3 gateway under its bridge domain. Which diagnostic record would most strongly confirm the result?
- For this deployment, examine a healthy optical light without checking protocol neighbors or forwarding entries.
- For this deployment, examine an up management interface without the relevant routing or forwarding table.
- For this deployment, examine aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
- For this deployment, examine a pre-change network diagram with no live control-plane state.
Explanation
Correct Answer
C:These observations test the actual ACI bridge domain subnet and VRF mechanism rather than a superficial management status. They should be checked after validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain.
Incorrect Answers
A:A healthy optical light without checking protocol neighbors or forwarding entries. This information cannot independently verify ACI bridge domain subnet and VRF. The decisive records instead include aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
B:An up management interface without the relevant routing or forwarding table. This information cannot independently verify ACI bridge domain subnet and VRF. The decisive records instead include aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
D:A pre-change network diagram with no live control-plane state. This information cannot independently verify ACI bridge domain subnet and VRF. The decisive records instead include aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests. ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
Question 228
A newly deployed application subnet is associated with an EPG but lacks the expected Layer 3 gateway under its bridge domain. Which platform concept should guide the engineer’s assessment?
- For this condition, the applicable principle is that physical link carrier guarantees all overlay and routing states are correct.
- For this condition, the applicable principle is that a working management-plane ping proves every tenant and application path is healthy.
- For this condition, the applicable principle is that all control-plane protocols exchange state automatically after a cable is inserted.
- For this condition, the applicable principle is that ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding.
Explanation
Correct Answer
D:This explains why the most appropriate response is to validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain. In the given case, a newly deployed application subnet is associated with an EPG but lacks the expected Layer 3 gateway under its bridge domain.
Incorrect Answers
A:Physical link carrier guarantees all overlay and routing states are correct. This is an incorrect generalization for ACI bridge domain subnet and VRF. The applicable technical behavior is that ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. The operator should verify aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
B:A working management-plane ping proves every tenant and application path is healthy. This is an incorrect generalization for ACI bridge domain subnet and VRF. The applicable technical behavior is that ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. The operator should verify aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
C:All control-plane protocols exchange state automatically after a cable is inserted. This is an incorrect generalization for ACI bridge domain subnet and VRF. The applicable technical behavior is that ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. The operator should verify aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
Question 229
A newly deployed application subnet is associated with an EPG but lacks the expected Layer 3 gateway under its bridge domain. Assume an engineer instead chooses to add the same ambiguous subnet to unrelated tenant VRFs without design control. Which root-cause observation follows from that incorrect change?
- The resulting defect is that a missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment.
- The resulting defect is that investigating the forwarding table is the reason a broken route cannot converge.
- The resulting defect is that the only consequence of the wrong change is a different device description.
- The resulting defect is that preserving neighbor-state evidence is itself the source of the observed outage.
Explanation
Correct Answer
A:ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. The proper corrective action is to validate bridge-domain VRF attachment and configure the required subnet gateway under the bridge domain.
Incorrect Answers
B:This does not explain the actual ACI bridge domain subnet and VRF defect after the shortcut. In the given case, a newly deployed application subnet is associated with an EPG but lacks the expected Layer 3 gateway under its bridge domain.
C:This does not explain the actual ACI bridge domain subnet and VRF defect after the shortcut. The only consequence of the wrong change is a different device description.
D:This does not explain the actual ACI bridge domain subnet and VRF defect after the shortcut. Preserving neighbor-state evidence is itself the source of the observed outage.
Question 230
A newly deployed application subnet is associated with an EPG but lacks the expected Layer 3 gateway under its bridge domain. The observed failure is: a missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to expect a Cisco UCS service profile to install an ACI gateway automatically.
- The controlled remediation is to fix the BD subnet and routing association and verify tenant reachability under permitted contracts.
- The controlled remediation is to add the same ambiguous subnet to unrelated tenant VRFs without design control.
- The controlled remediation is to modify only the endpoint naming convention.
Explanation
Correct Answer
B:ACI bridge domains provide Layer 2 context and can define subnets used for tenant Layer 3 forwarding. Validate against aPIC bridge-domain subnet, VRF association, learned endpoints, and gateway reachability tests.
Incorrect Answers
A:Expect a Cisco UCS service profile to install an ACI gateway automatically. This would not reliably restore service after the stated fault. A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The controlled recovery is to fix the BD subnet and routing association and verify tenant reachability under permitted contracts.
C:Add the same ambiguous subnet to unrelated tenant VRFs without design control. This would not reliably restore service after the stated fault. A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The controlled recovery is to fix the BD subnet and routing association and verify tenant reachability under permitted contracts.
D:Modify only the endpoint naming convention. This would not reliably restore service after the stated fault. A missing or incorrect BD subnet prevents endpoint default-gateway reachability despite physical attachment. The controlled recovery is to fix the BD subnet and routing association and verify tenant reachability under permitted contracts.