Cisco 300-610 Practice Test 32
Question 310
At an Intersight-managed UCS cluster, the architecture standards group considers the recurring risk: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. The team needs a defensible design decision rather than a vendor feature checklist. Which continuing design control best prevents the same problem from recurring?
- Audit DCB maps whenever FI uplink trunk policies change.
- Retest interoperability after FI firmware or storage array upgrades.
- Require dual-fabric path tests before production datastore activation.
- Review backup-fabric capacity before adding demanding workloads.
Explanation
Correct Answer
B:The most relevant ongoing safeguard is: Retest interoperability after FI firmware or storage array upgrades. The risk it addresses is: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. This check is tied to the technical principle: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. The immediate correction remains: Confirm vendor support, port roles and design prerequisites before choosing direct-attached FC instead of traditional SAN switching. Periodically validate the safeguard through two different observations. Check supported FI model/software and array interoperability tables Verify intended target login and failover in an approved proof of concept. The continuing acceptance target is: The selected storage topology provides documented, supported connectivity and redundancy.
Incorrect Answers
A:This is a continuing control for fcoe no-drop priority isolation; its underlying principle is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. The recurring risk here is different: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The intended long-term acceptance condition remains: The selected storage topology provides documented, supported connectivity and redundancy.
C:This is a continuing control for dual-fabric fibre channel san paths; its underlying principle is: SAN multipath resiliency relies on independent initiator paths, FI fabrics, switches and target portals, not merely on two WWPNs. The recurring risk here is different: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A UCS database server has two virtual HBAs but both paths terminate on fabric A and lose all storage when it goes down. The intended long-term acceptance condition remains: The selected storage topology provides documented, supported connectivity and redundancy.
D:This is a continuing control for storage path failover with asymmetric bandwidth; its underlying principle is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity. The recurring risk here is different: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The intended long-term acceptance condition remains: The selected storage topology provides documented, supported connectivity and redundancy.
Question 311
At an Intersight-managed UCS cluster, a proposed deployment has this failure mode: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The maintenance plan must not disrupt unrelated tenants. Which design correction most directly addresses this specific failure or requirement?
- Correct the approved FCoE VLAN-to-VSAN association and preserve tenant SAN isolation.
- Budget capacity and queueing under one-fabric failure using expected peak storage demand.
- Confirm vendor support, port roles and design prerequisites before choosing direct-attached FC instead of traditional SAN switching.
- Select supported FC mode and connect each fabric to suitable NPIV-capable upstream switches with correct VSAN connectivity.
Explanation
Correct Answer
B:The relevant failure is: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The technical distinction is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity. The targeted correction is: Budget capacity and queueing under one-fabric failure using expected peak storage demand. Before changing the design, check two independent observations. Inspect per-fabric FC port rate and oversubscription Measure application latency with one path intentionally removed. Accept the change only if: Degraded-mode I/O remains within the agreed business recovery and performance limits.
Incorrect Answers
A:This action targets fcoe vlan versus san vsan mapping, where the mechanism is: FCoE uses an appropriate Ethernet transport and VLAN mapping while FC zoning and fabric membership remain VSAN scoped. That is a separate condition from the problem in this question: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. Even a successful repair of the alternative would not establish the required result: Degraded-mode I/O remains within the agreed business recovery and performance limits. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
C:This action targets direct-attached fc storage support boundaries, where the mechanism is: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. That is a separate condition from the problem in this question: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. Even a successful repair of the alternative would not establish the required result: Degraded-mode I/O remains within the agreed business recovery and performance limits. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
D:This action targets fc end-host npv uplink identity, where the mechanism is: In FC end-host mode, UCS FI behaves as an NPV gateway with upstream NPIV-capable fabric switches, not as a fabric-merging FC core. That is a separate condition from the problem in this question: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. Even a successful repair of the alternative would not establish the required result: Degraded-mode I/O remains within the agreed business recovery and performance limits. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
Question 312
At a dual-fabric virtualization host estate, the cause remains unconfirmed for this reported issue: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. Acceptance requires evidence from the running system, not just the saved design. Which pair of observations most directly tests the proposed diagnosis before a change?
- Trace each vHBA WWPN through separate fabric switches; test a controlled fabric A loss while observing datastore I/O.
- Inspect per-fabric FC port rate and oversubscription; measure application latency with one path intentionally removed.
- Inspect FCoE priority/CoS at FI and switch; correlate PFC or drop counters with storage path resets under stress.
- Check supported FI model/software and array interoperability tables; verify intended target login and failover in an approved proof of concept.
Explanation
Correct Answer
B:The first observation is: Inspect per-fabric FC port rate and oversubscription The independent second observation is: Measure application latency with one path intentionally removed. Together they test the proposed diagnosis of this incident: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The underlying technical principle is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity. If those checks confirm it, the appropriate next action is: Budget capacity and queueing under one-fabric failure using expected peak storage demand. The expected measurable result is: Degraded-mode I/O remains within the agreed business recovery and performance limits.
Incorrect Answers
A:These observations investigate dual-fabric fibre channel san paths; they would be useful if the symptoms were: A UCS database server has two virtual HBAs but both paths terminate on fabric A and lose all storage when it goes down. That alternative rests on the principle: SAN multipath resiliency relies on independent initiator paths, FI fabrics, switches and target portals, not merely on two WWPNs. The question instead asks for evidence about: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The discriminating observations here are: Inspect per-fabric FC port rate and oversubscription Measure application latency with one path intentionally removed.
C:These observations investigate fcoe no-drop priority isolation; they would be useful if the symptoms were: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. That alternative rests on the principle: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. The question instead asks for evidence about: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The discriminating observations here are: Inspect per-fabric FC port rate and oversubscription Measure application latency with one path intentionally removed.
D:These observations investigate direct-attached fc storage support boundaries; they would be useful if the symptoms were: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. That alternative rests on the principle: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. The question instead asks for evidence about: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The discriminating observations here are: Inspect per-fabric FC port rate and oversubscription Measure application latency with one path intentionally removed.
Question 313
At a Cisco UCS domain expansion, a failure review must identify the central technical cause of: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. One component outage must remain inside the agreed availability budget. Which engineering principle best explains the observed behavior?
- vHBA virtual link rates do not create physical FC capacity; SAN fabric uplink bandwidth and oversubscription must be budgeted.
- Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity.
- FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes.
- Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility.
Explanation
Correct Answer
B:The controlling technical principle is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity. This matters because the reported design failure is: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The first diagnostic check is: Inspect per-fabric FC port rate and oversubscription The independent check is: Measure application latency with one path intentionally removed. These facts support the targeted intervention: Budget capacity and queueing under one-fabric failure using expected peak storage demand. Confirm that the resulting design meets this condition: Degraded-mode I/O remains within the agreed business recovery and performance limits.
Incorrect Answers
A:The offered principle describes fc uplink throughput for storage: vHBA virtual link rates do not create physical FC capacity; SAN fabric uplink bandwidth and oversubscription must be budgeted. That is useful for a distinct incident, such as: A UCS fabric adds many high-speed vHBAs but uses only one slow FC uplink and experiences queueing at peak backup time. It does not account for the reported failure: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The governing principle in this situation is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity.
C:The offered principle describes fcoe no-drop priority isolation: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. That is useful for a distinct incident, such as: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. It does not account for the reported failure: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The governing principle in this situation is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity.
D:The offered principle describes direct-attached fc storage support boundaries: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. That is useful for a distinct incident, such as: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. It does not account for the reported failure: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The governing principle in this situation is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity.
Question 314
At a modular X-Series compute design, the service owner needs evidence of resolution for: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The architect must preserve the intended failure domains. Which measured result most directly proves the original requirement is satisfied?
- Each vHBA logs into the correct isolated SAN fabric and receives authorized storage zoning.
- Host initiators discover only approved targets through the intended SAN domain.
- Storage remains accessible through the surviving SAN fabric without an unsupported failover mechanism.
- Degraded-mode I/O remains within the agreed business recovery and performance limits.
Explanation
Correct Answer
D:The relevant measurable success criterion is: Degraded-mode I/O remains within the agreed business recovery and performance limits. It addresses the original reported defect: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. A saved design or configuration command alone does not establish that outcome. Observe the affected system in two independent ways: Inspect per-fabric FC port rate and oversubscription Measure application latency with one path intentionally removed. The correction being evaluated is: Budget capacity and queueing under one-fabric failure using expected peak storage demand. The underlying reason that correction matters is: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity.
Incorrect Answers
A:This metric would help validate a correction to fc end-host npv uplink identity, rather than the original reported issue. The other issue is: An FI operates Fibre Channel end-host/NPV mode, yet a design expects it to merge two upstream fabrics as a standalone FC switch. Here the defect to be resolved is: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The expected measurable outcome for the actual incident is: Degraded-mode I/O remains within the agreed business recovery and performance limits. A positive result for the other service would not prove this requirement is met.
B:This metric would help validate a correction to fcoe vlan versus san vsan mapping, rather than the original reported issue. The other issue is: A UCS vHBA uses FCoE traffic on an Ethernet uplink but the upstream switch maps it to the wrong VSAN. Here the defect to be resolved is: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The expected measurable outcome for the actual incident is: Degraded-mode I/O remains within the agreed business recovery and performance limits. A positive result for the other service would not prove this requirement is met.
C:This metric would help validate a correction to dual-fabric fibre channel san paths, rather than the original reported issue. The other issue is: A UCS database server has two virtual HBAs but both paths terminate on fabric A and lose all storage when it goes down. Here the defect to be resolved is: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The expected measurable outcome for the actual incident is: Degraded-mode I/O remains within the agreed business recovery and performance limits. A positive result for the other service would not prove this requirement is met.
Question 315
At a mission-critical UCS blade installation, after correction, the team wants to prevent recurrence of: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The team needs a defensible design decision rather than a vendor feature checklist. Which continuing design control best prevents the same problem from recurring?
- Review backup-fabric capacity before adding demanding workloads.
- Require dual-fabric path tests before production datastore activation.
- Validate FCoE mapping whenever converged network VLAN allocation changes.
- Audit DCB maps whenever FI uplink trunk policies change.
Explanation
Correct Answer
A:The most relevant ongoing safeguard is: Review backup-fabric capacity before adding demanding workloads. The risk it addresses is: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. This check is tied to the technical principle: Availability paths also require degraded-mode performance planning; two physically diverse links alone do not guarantee equal capacity. The immediate correction remains: Budget capacity and queueing under one-fabric failure using expected peak storage demand. Periodically validate the safeguard through two different observations. Inspect per-fabric FC port rate and oversubscription Measure application latency with one path intentionally removed. The continuing acceptance target is: Degraded-mode I/O remains within the agreed business recovery and performance limits.
Incorrect Answers
B:This is a continuing control for dual-fabric fibre channel san paths; its underlying principle is: SAN multipath resiliency relies on independent initiator paths, FI fabrics, switches and target portals, not merely on two WWPNs. The recurring risk here is different: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A UCS database server has two virtual HBAs but both paths terminate on fabric A and lose all storage when it goes down. The intended long-term acceptance condition remains: Degraded-mode I/O remains within the agreed business recovery and performance limits.
C:This is a continuing control for fcoe vlan versus san vsan mapping; its underlying principle is: FCoE uses an appropriate Ethernet transport and VLAN mapping while FC zoning and fabric membership remain VSAN scoped. The recurring risk here is different: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A UCS vHBA uses FCoE traffic on an Ethernet uplink but the upstream switch maps it to the wrong VSAN. The intended long-term acceptance condition remains: Degraded-mode I/O remains within the agreed business recovery and performance limits.
D:This is a continuing control for fcoe no-drop priority isolation; its underlying principle is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. The recurring risk here is different: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The intended long-term acceptance condition remains: Degraded-mode I/O remains within the agreed business recovery and performance limits.
Question 316
At a mission-critical UCS blade installation, a design review reports the following issue: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The maintenance plan must not disrupt unrelated tenants. Which design correction most directly addresses this specific failure or requirement?
- Correct the approved FCoE VLAN-to-VSAN association and preserve tenant SAN isolation.
- Provide dedicated and consistently marked storage queues with appropriate DCB/QoS while isolating other traffic classes.
- Allocate one supported vHBA per fabric and validate operating-system MPIO and SAN zoning end to end.
- Confirm vendor support, port roles and design prerequisites before choosing direct-attached FC instead of traditional SAN switching.
Explanation
Correct Answer
B:The relevant failure is: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The technical distinction is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. The targeted correction is: Provide dedicated and consistently marked storage queues with appropriate DCB/QoS while isolating other traffic classes. Before changing the design, check two independent observations. Inspect FCoE priority/CoS at FI and switch Correlate PFC or drop counters with storage path resets under stress. Accept the change only if: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.
Incorrect Answers
A:This action targets fcoe vlan versus san vsan mapping, where the mechanism is: FCoE uses an appropriate Ethernet transport and VLAN mapping while FC zoning and fabric membership remain VSAN scoped. That is a separate condition from the problem in this question: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. Even a successful repair of the alternative would not establish the required result: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
C:This action targets dual-fabric fibre channel san paths, where the mechanism is: SAN multipath resiliency relies on independent initiator paths, FI fabrics, switches and target portals, not merely on two WWPNs. That is a separate condition from the problem in this question: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. Even a successful repair of the alternative would not establish the required result: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
D:This action targets direct-attached fc storage support boundaries, where the mechanism is: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. That is a separate condition from the problem in this question: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. Even a successful repair of the alternative would not establish the required result: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
Question 317
At an Intersight-managed UCS cluster, two engineers propose competing diagnoses for this condition: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. Acceptance requires evidence from the running system, not just the saved design. Which pair of observations most directly tests the proposed diagnosis before a change?
- Inspect FCoE priority/CoS at FI and switch; correlate PFC or drop counters with storage path resets under stress.
- Inspect FC uplink credit and congestion counters; measure storage I/O with one SAN fabric in a permitted failover test.
- Check supported FI model/software and array interoperability tables; verify intended target login and failover in an approved proof of concept.
- Inspect FCoE VLAN and VSAN bindings at FI and upstream switch; verify fabric login and target discovery on the correct VSAN.
Explanation
Correct Answer
A:The first observation is: Inspect FCoE priority/CoS at FI and switch The independent second observation is: Correlate PFC or drop counters with storage path resets under stress. Together they test the proposed diagnosis of this incident: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The underlying technical principle is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. If those checks confirm it, the appropriate next action is: Provide dedicated and consistently marked storage queues with appropriate DCB/QoS while isolating other traffic classes. The expected measurable result is: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.
Incorrect Answers
B:These observations investigate fc uplink throughput for storage; they would be useful if the symptoms were: A UCS fabric adds many high-speed vHBAs but uses only one slow FC uplink and experiences queueing at peak backup time. That alternative rests on the principle: vHBA virtual link rates do not create physical FC capacity; SAN fabric uplink bandwidth and oversubscription must be budgeted. The question instead asks for evidence about: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The discriminating observations here are: Inspect FCoE priority/CoS at FI and switch Correlate PFC or drop counters with storage path resets under stress.
C:These observations investigate direct-attached fc storage support boundaries; they would be useful if the symptoms were: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. That alternative rests on the principle: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. The question instead asks for evidence about: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The discriminating observations here are: Inspect FCoE priority/CoS at FI and switch Correlate PFC or drop counters with storage path resets under stress.
D:These observations investigate fcoe vlan versus san vsan mapping; they would be useful if the symptoms were: A UCS vHBA uses FCoE traffic on an Ethernet uplink but the upstream switch maps it to the wrong VSAN. That alternative rests on the principle: FCoE uses an appropriate Ethernet transport and VLAN mapping while FC zoning and fabric membership remain VSAN scoped. The question instead asks for evidence about: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The discriminating observations here are: Inspect FCoE priority/CoS at FI and switch Correlate PFC or drop counters with storage path resets under stress.
Question 318
At a dual-fabric virtualization host estate, the design group challenges an assumption behind this issue: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. One component outage must remain inside the agreed availability budget. Which engineering principle best explains the observed behavior?
- FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes.
- SAN multipath resiliency relies on independent initiator paths, FI fabrics, switches and target portals, not merely on two WWPNs.
- Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility.
- vHBA virtual link rates do not create physical FC capacity; SAN fabric uplink bandwidth and oversubscription must be budgeted.
Explanation
Correct Answer
A:The controlling technical principle is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. This matters because the reported design failure is: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The first diagnostic check is: Inspect FCoE priority/CoS at FI and switch The independent check is: Correlate PFC or drop counters with storage path resets under stress. These facts support the targeted intervention: Provide dedicated and consistently marked storage queues with appropriate DCB/QoS while isolating other traffic classes. Confirm that the resulting design meets this condition: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.
Incorrect Answers
B:The offered principle describes dual-fabric fibre channel san paths: SAN multipath resiliency relies on independent initiator paths, FI fabrics, switches and target portals, not merely on two WWPNs. That is useful for a distinct incident, such as: A UCS database server has two virtual HBAs but both paths terminate on fabric A and lose all storage when it goes down. It does not account for the reported failure: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The governing principle in this situation is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes.
C:The offered principle describes direct-attached fc storage support boundaries: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. That is useful for a distinct incident, such as: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. It does not account for the reported failure: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The governing principle in this situation is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes.
D:The offered principle describes fc uplink throughput for storage: vHBA virtual link rates do not create physical FC capacity; SAN fabric uplink bandwidth and oversubscription must be budgeted. That is useful for a distinct incident, such as: A UCS fabric adds many high-speed vHBAs but uses only one slow FC uplink and experiences queueing at peak backup time. It does not account for the reported failure: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The governing principle in this situation is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes.
Question 319
At a Cisco UCS domain expansion, a change has been proposed for the following condition: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The architect must preserve the intended failure domains. Which measured result most directly proves the original requirement is satisfied?
- Degraded-mode I/O remains within the agreed business recovery and performance limits.
- Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.
- Storage meets performance and availability objectives in normal and degraded modes.
- Host initiators discover only approved targets through the intended SAN domain.
Explanation
Correct Answer
B:The relevant measurable success criterion is: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally. It addresses the original reported defect: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. A saved design or configuration command alone does not establish that outcome. Observe the affected system in two independent ways: Inspect FCoE priority/CoS at FI and switch Correlate PFC or drop counters with storage path resets under stress. The correction being evaluated is: Provide dedicated and consistently marked storage queues with appropriate DCB/QoS while isolating other traffic classes. The underlying reason that correction matters is: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes.
Incorrect Answers
A:This metric would help validate a correction to storage path failover with asymmetric bandwidth, rather than the original reported issue. The other issue is: Two SAN fabrics exist but one has much less bandwidth, so losing the primary fabric creates unacceptable I/O latency. Here the defect to be resolved is: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The expected measurable outcome for the actual incident is: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally. A positive result for the other service would not prove this requirement is met.
C:This metric would help validate a correction to fc uplink throughput for storage, rather than the original reported issue. The other issue is: A UCS fabric adds many high-speed vHBAs but uses only one slow FC uplink and experiences queueing at peak backup time. Here the defect to be resolved is: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The expected measurable outcome for the actual incident is: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally. A positive result for the other service would not prove this requirement is met.
D:This metric would help validate a correction to fcoe vlan versus san vsan mapping, rather than the original reported issue. The other issue is: A UCS vHBA uses FCoE traffic on an Ethernet uplink but the upstream switch maps it to the wrong VSAN. Here the defect to be resolved is: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The expected measurable outcome for the actual incident is: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally. A positive result for the other service would not prove this requirement is met.
Question 320
At a modular X-Series compute design, a post-incident design review focuses on preventing: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The team needs a defensible design decision rather than a vendor feature checklist. Which continuing design control best prevents the same problem from recurring?
- Retest interoperability after FI firmware or storage array upgrades.
- Re-run SAN oversubscription analysis when new host profiles increase I/O demand.
- Audit DCB maps whenever FI uplink trunk policies change.
- Require dual-fabric path tests before production datastore activation.
Explanation
Correct Answer
C:The most relevant ongoing safeguard is: Audit DCB maps whenever FI uplink trunk policies change. The risk it addresses is: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. This check is tied to the technical principle: FCoE storage transport needs coherent supported Data Center Bridging QoS, commonly including PFC for assigned storage traffic classes. The immediate correction remains: Provide dedicated and consistently marked storage queues with appropriate DCB/QoS while isolating other traffic classes. Periodically validate the safeguard through two different observations. Inspect FCoE priority/CoS at FI and switch Correlate PFC or drop counters with storage path resets under stress. The continuing acceptance target is: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.
Incorrect Answers
A:This is a continuing control for direct-attached fc storage support boundaries; its underlying principle is: Direct-attached FC storage and FCoE port roles are platform/release dependent and must be verified against specific Cisco FI and array compatibility. The recurring risk here is different: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A design assumes every UCS FI and storage array combination supports direct FC target attachment in the same way as an external SAN switch. The intended long-term acceptance condition remains: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.
B:This is a continuing control for fc uplink throughput for storage; its underlying principle is: vHBA virtual link rates do not create physical FC capacity; SAN fabric uplink bandwidth and oversubscription must be budgeted. The recurring risk here is different: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A UCS fabric adds many high-speed vHBAs but uses only one slow FC uplink and experiences queueing at peak backup time. The intended long-term acceptance condition remains: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.
D:This is a continuing control for dual-fabric fibre channel san paths; its underlying principle is: SAN multipath resiliency relies on independent initiator paths, FI fabrics, switches and target portals, not merely on two WWPNs. The recurring risk here is different: An Ethernet network combines FCoE SAN traffic with lossy application bursts but does not reserve appropriate lossless treatment. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A UCS database server has two virtual HBAs but both paths terminate on fabric A and lose all storage when it goes down. The intended long-term acceptance condition remains: Storage traffic avoids preventable frame loss without pausing unrelated IP services globally.