Cisco 300-420 Practice Test 51
Question 500
An enterprise design requires WAN availability after one last-mile cable cut and a single carrier maintenance outage. The observed fault is: Two labeled circuits that share a duct or provider POP can fail together under a single incident. Which recovery is BEST once this fault is identified?
- The controlled recovery is to assume redundant CE router power supplies prevent external carrier outages.
- The controlled recovery is to buy two circuits over the same last-mile fiber and claim complete physical diversity.
- The controlled recovery is to use two VLAN tags on one single modem as proof of independent providers.
- The controlled recovery is to audit and diversify actual WAN delivery paths then simulate one carrier or conduit failure.
Explanation
Correct Answer
D:Relevant evidence includes carrier IDs, path and conduit maps, diverse POPs, BGP adjacency and failure test results. This corrects the described failure and provides a verifiable outcome.
Incorrect Answers
A:Assume redundant CE router power supplies prevent external carrier outages. Two labeled circuits that share a duct or provider POP can fail together under a single incident. Use the controlled remediation: audit and diversify actual WAN delivery paths then simulate one carrier or conduit failure.
B:Buy two circuits over the same last-mile fiber and claim complete physical diversity. Two labeled circuits that share a duct or provider POP can fail together under a single incident. Use the controlled remediation: audit and diversify actual WAN delivery paths then simulate one carrier or conduit failure. In this case, an enterprise design requires WAN availability after one last-mile cable cut and a single carrier maintenance outage.
C:Use two VLAN tags on one single modem as proof of independent providers. Two labeled circuits that share a duct or provider POP can fail together under a single incident. Use the controlled remediation: audit and diversify actual WAN delivery paths then simulate one carrier or conduit failure.
Question 501
A branch router has dual links but its primary physical interface remains up after upstream Internet service stops forwarding. Which enterprise design procedure best meets this requirement?
- Declare the primary route healthy solely because Ethernet carrier remains up.
- Give backup and primary routes random equal preferences without testing oscillation.
- Combine suitable tracked reachability or routing liveliness with backup path preference and failback policy.
- Assume an alternate WAN cable supplies automatic failover without route or controller policy.
Explanation
Correct Answer
C:Confirm the result using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening. WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone.
Incorrect Answers
A:This change targets the wrong mechanism for WAN IP SLA tracking and backup path failover. Depending only on interface line protocol can keep directing traffic into an upstream blackhole.
B:Give backup and primary routes random equal preferences without testing oscillation. WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Instead inspect probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
D:Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Assume an alternate WAN cable supplies automatic failover without route or controller policy.
Question 502
A branch router has dual links but its primary physical interface remains up after upstream Internet service stops forwarding. Which evidence best distinguishes the intended state from a superficial indicator?
- An old network diagram with no current route, policy, or redundancy state.
- One successful ping to an unrelated test host without a path or failover test.
- Probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
- A marketing claim without measured routing, capacity or failure-domain evidence.
Explanation
Correct Answer
C:The intended procedure is combine suitable tracked reachability or routing liveliness with backup path preference and failback policy. WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone.
Incorrect Answers
A:This observation alone cannot establish wAN IP SLA tracking and backup path failover. The decisive evidence instead includes probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
B:This observation alone cannot establish wAN IP SLA tracking and backup path failover. WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone.
D:This observation alone cannot establish wAN IP SLA tracking and backup path failover. A marketing claim without measured routing, capacity or failure-domain evidence.
Question 503
A branch router has dual links but its primary physical interface remains up after upstream Internet service stops forwarding. Which underlying principle explains the correct decision?
- WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone.
- An operational up state alone proves every security and design objective is met.
- Any single device automatically guarantees high availability for every site.
- A longer IP prefix is always less specific than the default route.
Explanation
Correct Answer
A:Confirm it with probe target selection, track state, primary and secondary routes, failover latency and recovery dampening. This is why the appropriate action is combine suitable tracked reachability or routing liveliness with backup path preference and failback policy.
Incorrect Answers
B:An operational up state alone proves every security and design objective is met. This is an incorrect generalization for wAN IP SLA tracking and backup path failover. The relevant rule is wAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Verify using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
C:Any single device automatically guarantees high availability for every site. This is an incorrect generalization for wAN IP SLA tracking and backup path failover. The relevant rule is wAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Verify using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
D:A longer IP prefix is always less specific than the default route. This is an incorrect generalization for wAN IP SLA tracking and backup path failover. The relevant rule is wAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Verify using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
Question 504
A branch router has dual links but its primary physical interface remains up after upstream Internet service stops forwarding. Suppose the operator instead makes this incorrect change: Declare the primary route healthy solely because Ethernet carrier remains up. What is the most material consequence of that mistake?
- Depending only on interface line protocol can keep directing traffic into an upstream blackhole.
- The failure is entirely cosmetic because all control-plane changes are harmless.
- Collecting telemetry originally caused the missing route or service outage.
- A correct change-control review makes all WAN carriers fail simultaneously.
Explanation
Correct Answer
A:This explains why the proposed shortcut does not solve wAN IP SLA tracking and backup path failover. WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone.
Incorrect Answers
B:The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is depending only on interface line protocol can keep directing traffic into an upstream blackhole. Check probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
C:Collecting telemetry originally caused the missing route or service outage. The actual failure is depending only on interface line protocol can keep directing traffic into an upstream blackhole. Check probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
D:A correct change-control review makes all WAN carriers fail simultaneously. The actual failure is depending only on interface line protocol can keep directing traffic into an upstream blackhole. Check probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
Question 505
A branch router has dual links but its primary physical interface remains up after upstream Internet service stops forwarding. The observed fault is: Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Which controlled remediation should be used?
- Give backup and primary routes random equal preferences without testing oscillation.
- Track a representative target and validate stable switchovers and controlled return to primary.
- Assume an alternate WAN cable supplies automatic failover without route or controller policy.
- Declare the primary route healthy solely because Ethernet carrier remains up.
Explanation
Correct Answer
B:Relevant evidence includes probe target selection, track state, primary and secondary routes, failover latency and recovery dampening. WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone.
Incorrect Answers
A:Give backup and primary routes random equal preferences without testing oscillation. Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Use the controlled remediation: track a representative target and validate stable switchovers and controlled return to primary.
C:Assume an alternate WAN cable supplies automatic failover without route or controller policy. Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Use the controlled remediation: track a representative target and validate stable switchovers and controlled return to primary.
D:Declare the primary route healthy solely because Ethernet carrier remains up. Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Use the controlled remediation: track a representative target and validate stable switchovers and controlled return to primary.
Question 506
A remote site needs automated failover to LTE only when its wired route actually becomes unusable. What is the most defensible configuration decision?
- For this enterprise design, the architect should give backup and primary routes random equal preferences without testing oscillation.
- For this enterprise design, the architect should assume an alternate WAN cable supplies automatic failover without route or controller policy.
- For this enterprise design, the architect should combine suitable tracked reachability or routing liveliness with backup path preference and failback policy.
- For this enterprise design, the architect should declare the primary route healthy solely because Ethernet carrier remains up.
Explanation
Correct Answer
C:Confirm the result using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening. This is the specific corrective action for WAN IP SLA tracking and backup path failover.
Incorrect Answers
A:Give backup and primary routes random equal preferences without testing oscillation. WAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Instead inspect probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
B:Depending only on interface line protocol can keep directing traffic into an upstream blackhole.
D:This change targets the wrong mechanism for WAN IP SLA tracking and backup path failover. The relevant action is combine suitable tracked reachability or routing liveliness with backup path preference and failback policy.
Question 507
A remote site needs automated failover to LTE only when its wired route actually becomes unusable. Which evidence BEST confirms the actual technical behavior?
- Inspect the following evidence: a hostname inventory without effective configuration or operational measurements.
- Inspect the following evidence: an old network diagram with no current route, policy, or redundancy state.
- Inspect the following evidence: one successful ping to an unrelated test host without a path or failover test.
- Inspect the following evidence: probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
Explanation
Correct Answer
D:The intended procedure is combine suitable tracked reachability or routing liveliness with backup path preference and failback policy. This evidence observes the actual wAN IP SLA tracking and backup path failover mechanism and its result.
Incorrect Answers
A:This observation alone cannot establish wAN IP SLA tracking and backup path failover. A hostname inventory without effective configuration or operational measurements.
B:This observation alone cannot establish wAN IP SLA tracking and backup path failover. In this case, a remote site needs automated failover to LTE only when its wired route actually becomes unusable.
C:This observation alone cannot establish wAN IP SLA tracking and backup path failover. One successful ping to an unrelated test host without a path or failover test.
Question 508
A remote site needs automated failover to LTE only when its wired route actually becomes unusable. What networking or enterprise network design concept best explains this scenario?
- The relevant principle is that a longer IP prefix is always less specific than the default route.
- The relevant principle is that an operational up state alone proves every security and design objective is met.
- The relevant principle is that wAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone.
- The relevant principle is that encryption and segmentation are identical mechanisms and can replace each other.
Explanation
Correct Answer
C:Confirm it with probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
Incorrect Answers
A:A longer IP prefix is always less specific than the default route. This is an incorrect generalization for wAN IP SLA tracking and backup path failover. The relevant rule is wAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Verify using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
B:An operational up state alone proves every security and design objective is met. This is an incorrect generalization for wAN IP SLA tracking and backup path failover. The relevant rule is wAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Verify using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
D:Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for wAN IP SLA tracking and backup path failover. The relevant rule is wAN path selection should reflect end-to-end usable reachability rather than interface carrier status alone. Verify using probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
Question 509
A remote site needs automated failover to LTE only when its wired route actually becomes unusable. Suppose the operator instead makes this incorrect change: Declare the primary route healthy solely because Ethernet carrier remains up. Which resulting fault should the reviewer identify?
- The resulting technical fault is that depending only on interface line protocol can keep directing traffic into an upstream blackhole.
- The resulting technical fault is that a correct change-control review makes all WAN carriers fail simultaneously.
- The resulting technical fault is that the only issue is an inaccurate hostname while traffic paths are unaffected.
- The resulting technical fault is that collecting telemetry originally caused the missing route or service outage.
Explanation
Correct Answer
A:This explains why the proposed shortcut does not solve wAN IP SLA tracking and backup path failover. The right response is combine suitable tracked reachability or routing liveliness with backup path preference and failback policy.
Incorrect Answers
B:A correct change-control review makes all WAN carriers fail simultaneously. The actual failure is depending only on interface line protocol can keep directing traffic into an upstream blackhole. Check probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
C:The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is depending only on interface line protocol can keep directing traffic into an upstream blackhole. Check probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
D:Collecting telemetry originally caused the missing route or service outage. The actual failure is depending only on interface line protocol can keep directing traffic into an upstream blackhole. Check probe target selection, track state, primary and secondary routes, failover latency and recovery dampening.
Question 510
A remote site needs automated failover to LTE only when its wired route actually becomes unusable. The observed fault is: Depending only on interface line protocol can keep directing traffic into an upstream blackhole. How should the issue be corrected and verified?
- The controlled recovery is to assume an alternate WAN cable supplies automatic failover without route or controller policy.
- The controlled recovery is to declare the primary route healthy solely because Ethernet carrier remains up.
- The controlled recovery is to give backup and primary routes random equal preferences without testing oscillation.
- The controlled recovery is to track a representative target and validate stable switchovers and controlled return to primary.
Explanation
Correct Answer
D:Relevant evidence includes probe target selection, track state, primary and secondary routes, failover latency and recovery dampening. This corrects the described failure and provides a verifiable outcome.
Incorrect Answers
A:Assume an alternate WAN cable supplies automatic failover without route or controller policy. Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Use the controlled remediation: track a representative target and validate stable switchovers and controlled return to primary.
B:Declare the primary route healthy solely because Ethernet carrier remains up. Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Use the controlled remediation: track a representative target and validate stable switchovers and controlled return to primary.
C:Give backup and primary routes random equal preferences without testing oscillation. Depending only on interface line protocol can keep directing traffic into an upstream blackhole. Use the controlled remediation: track a representative target and validate stable switchovers and controlled return to primary.