cert
cert-1
cert-2

Pass Cisco 300-420 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
300-420 Exam - Verified By Experts
300-420 Premium Bundle
$29.98

300-420 Premium Bundle

$79.99
$109.97
  • Premium File 416 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 75 Video Lectures
  • Study Guide 751 Pages
 
$109.97
$79.99
accept 33 downloads in last 7 days
block-screenshots
Purchase Cisco 300-420 Exam Training Products Individually
Cisco 300-420 Premium File
Premium File 416 Q&A
$76.99$69.99
Cisco 300-420 Video Training Course
Training Course 75 Lectures
$21.99 $19.99
Cisco 300-420 PDF Study Guide
Study Guide 751 Pages
$21.99 $19.99
Cisco 300-420 Practice Test 25

Question 240

A platform must preserve viable forwarding during a route processor failover while neighbors reconverge. The observed fault is: Assuming any hardware reboot is hitless regardless of capability can result in unplanned campus outages. Which controlled remediation should be used?

  1. The controlled recovery is to disable adjacent protocol helper support while claiming end-to-end nonstop forwarding.
  2. The controlled recovery is to validate all participating device features and failover behavior and document unsupported cases.
  3. The controlled recovery is to promise zero traffic loss from any arbitrary platform reboot without feature verification.
  4. The controlled recovery is to use only an HSRP hostname change to deliver routing protocol graceful restart.

Explanation

Correct Answer

B:

Nonstop forwarding and graceful restart can preserve selected data-plane paths during eligible control-plane interruptions but depend on platform and peer support. Relevant evidence includes supervisor switchover state, forwarding table continuity, routing helper capability and controlled traffic tests.

Incorrect Answers

A:

Disable adjacent protocol helper support while claiming end-to-end nonstop forwarding. Assuming any hardware reboot is hitless regardless of capability can result in unplanned campus outages. Use the controlled remediation: validate all participating device features and failover behavior and document unsupported cases.

C:

Promise zero traffic loss from any arbitrary platform reboot without feature verification. Assuming any hardware reboot is hitless regardless of capability can result in unplanned campus outages. Use the controlled remediation: validate all participating device features and failover behavior and document unsupported cases.

D:

Use only an HSRP hostname change to deliver routing protocol graceful restart. Assuming any hardware reboot is hitless regardless of capability can result in unplanned campus outages. Use the controlled remediation: validate all participating device features and failover behavior and document unsupported cases.

Question 241

A campus link stays physically up while its far-end forwarding becomes unavailable and routing hellos detect the loss too slowly. What is the BEST supported implementation or corrective action?

  1. Assume BFD sessions automatically replace all routing protocol path selection.
  2. Configure the minimum possible timers without checking hardware and topology stability.
  3. Deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers.
  4. Expect Ethernet carrier up to guarantee the routed neighbor remains usable.

Explanation

Correct Answer

C:

Confirm the result using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity. BFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge.

Incorrect Answers

A:

Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. The relevant action is deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers.

B:

Configure the minimum possible timers without checking hardware and topology stability. BFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Instead inspect bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

D:

Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity.

Question 242

A campus link stays physically up while its far-end forwarding becomes unavailable and routing hellos detect the loss too slowly. What should the operator inspect to verify the result?

  1. A feature-license screenshot without the required design or acceptance tests.
  2. A marketing claim without measured routing, capacity or failure-domain evidence.
  3. A hostname inventory without effective configuration or operational measurements.
  4. BFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

Explanation

Correct Answer

D:

The intended procedure is deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers. BFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge.

Incorrect Answers

A:

This observation alone cannot establish bFD routing convergence failure detection. BFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge.

B:

This observation alone cannot establish bFD routing convergence failure detection. The decisive evidence instead includes bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

C:

This observation alone cannot establish bFD routing convergence failure detection. A hostname inventory without effective configuration or operational measurements.

Question 243

A campus link stays physically up while its far-end forwarding becomes unavailable and routing hellos detect the loss too slowly. Which technical statement is MOST accurate for this situation?

  1. Any single device automatically guarantees high availability for every site.
  2. Encryption and segmentation are identical mechanisms and can replace each other.
  3. BFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge.
  4. Cloud connectivity automatically removes any requirement for routing or policy.

Explanation

Correct Answer

C:

This is why the appropriate action is deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers. Confirm it with bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

Incorrect Answers

A:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for bFD routing convergence failure detection. The relevant rule is bFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Verify using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

B:

Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for bFD routing convergence failure detection. The relevant rule is bFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Verify using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

D:

Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for bFD routing convergence failure detection. The relevant rule is bFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Verify using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

Question 244

A campus link stays physically up while its far-end forwarding becomes unavailable and routing hellos detect the loss too slowly. Suppose the operator instead makes this incorrect change: Assume BFD sessions automatically replace all routing protocol path selection. What weakness does the mistaken approach introduce?

  1. The only issue is an inaccurate hostname while traffic paths are unaffected.
  2. A healthy unrelated system proves the intended failure domain is protected.
  3. Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity.
  4. The failure is entirely cosmetic because all control-plane changes are harmless.

Explanation

Correct Answer

C:

The right response is deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers.

Incorrect Answers

A:

The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Check bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

B:

A healthy unrelated system proves the intended failure domain is protected. The actual failure is overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Check bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

D:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Check bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

Question 245

A campus link stays physically up while its far-end forwarding becomes unavailable and routing hellos detect the loss too slowly. The observed fault is: Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Which recovery is BEST once this fault is identified?

  1. Configure the minimum possible timers without checking hardware and topology stability.
  2. Set supported timers and validate both real outage detection and false-positive rates.
  3. Expect Ethernet carrier up to guarantee the routed neighbor remains usable.
  4. Assume BFD sessions automatically replace all routing protocol path selection.

Explanation

Correct Answer

B:

Relevant evidence includes bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity. BFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge.

Incorrect Answers

A:

Configure the minimum possible timers without checking hardware and topology stability. Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Use the controlled remediation: set supported timers and validate both real outage detection and false-positive rates.

C:

Expect Ethernet carrier up to guarantee the routed neighbor remains usable. Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Use the controlled remediation: set supported timers and validate both real outage detection and false-positive rates.

D:

Assume BFD sessions automatically replace all routing protocol path selection. Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Use the controlled remediation: set supported timers and validate both real outage detection and false-positive rates.

Question 246

A routed distribution core needs quick path failure detection without drastically reducing all protocol hello timers. Which operator action most directly resolves this condition?

  1. For this enterprise design, the architect should deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers.
  2. For this enterprise design, the architect should configure the minimum possible timers without checking hardware and topology stability.
  3. For this enterprise design, the architect should expect Ethernet carrier up to guarantee the routed neighbor remains usable.
  4. For this enterprise design, the architect should assume BFD sessions automatically replace all routing protocol path selection.

Explanation

Correct Answer

A:

Confirm the result using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity. This is the specific corrective action for BFD routing convergence failure detection.

Incorrect Answers

B:

Configure the minimum possible timers without checking hardware and topology stability. BFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Instead inspect bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

C:

Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity.

D:

Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. This change targets the wrong mechanism for BFD routing convergence failure detection.

Question 247

A routed distribution core needs quick path failure detection without drastically reducing all protocol hello timers. Which collection of observations most directly tests the suspected cause?

  1. Inspect the following evidence: an old network diagram with no current route, policy, or redundancy state.
  2. Inspect the following evidence: bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.
  3. Inspect the following evidence: a feature-license screenshot without the required design or acceptance tests.
  4. Inspect the following evidence: a marketing claim without measured routing, capacity or failure-domain evidence.

Explanation

Correct Answer

B:

The intended procedure is deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers. This evidence observes the actual bFD routing convergence failure detection mechanism and its result.

Incorrect Answers

A:

This observation alone cannot establish bFD routing convergence failure detection. In this case, a routed distribution core needs quick path failure detection without drastically reducing all protocol hello timers.

C:

This observation alone cannot establish bFD routing convergence failure detection. A feature-license screenshot without the required design or acceptance tests.

D:

This observation alone cannot establish bFD routing convergence failure detection. A marketing claim without measured routing, capacity or failure-domain evidence.

Question 248

A routed distribution core needs quick path failure detection without drastically reducing all protocol hello timers. Which system behavior underlies the appropriate response?

  1. The relevant principle is that cloud connectivity automatically removes any requirement for routing or policy.
  2. The relevant principle is that any single device automatically guarantees high availability for every site.
  3. The relevant principle is that bFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge.
  4. The relevant principle is that a longer IP prefix is always less specific than the default route.

Explanation

Correct Answer

C:

This is why the appropriate action is deploy BFD where routing protocol and platform support provide suitable fast failure detection and tested timers.

Incorrect Answers

A:

Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for bFD routing convergence failure detection. The relevant rule is bFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Verify using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

B:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for bFD routing convergence failure detection. The relevant rule is bFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Verify using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

D:

A longer IP prefix is always less specific than the default route. This is an incorrect generalization for bFD routing convergence failure detection. The relevant rule is bFD can provide protocol-independent rapid liveliness detection and signal a routing protocol to reconverge. Verify using bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

Question 249

A routed distribution core needs quick path failure detection without drastically reducing all protocol hello timers. Suppose the operator instead makes this incorrect change: Assume BFD sessions automatically replace all routing protocol path selection. Which failure or risk follows from this shortcut?

  1. The resulting technical fault is that the failure is entirely cosmetic because all control-plane changes are harmless.
  2. The resulting technical fault is that overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity.
  3. The resulting technical fault is that collecting telemetry originally caused the missing route or service outage.
  4. The resulting technical fault is that a healthy unrelated system proves the intended failure domain is protected.

Explanation

Correct Answer

B:

This explains why the proposed shortcut does not solve bFD routing convergence failure detection.

Incorrect Answers

A:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Check bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

C:

Collecting telemetry originally caused the missing route or service outage. The actual failure is overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Check bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

D:

A healthy unrelated system proves the intended failure domain is protected. The actual failure is overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Check bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity.

Question 250

A routed distribution core needs quick path failure detection without drastically reducing all protocol hello timers. The observed fault is: Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. What action most directly restores and validates the intended state?

  1. The controlled recovery is to expect Ethernet carrier up to guarantee the routed neighbor remains usable.
  2. The controlled recovery is to assume BFD sessions automatically replace all routing protocol path selection.
  3. The controlled recovery is to configure the minimum possible timers without checking hardware and topology stability.
  4. The controlled recovery is to set supported timers and validate both real outage detection and false-positive rates.

Explanation

Correct Answer

D:

Relevant evidence includes bFD session state, routing adjacency dependencies, failure detection latency and CPU capacity. This corrects the described failure and provides a verifiable outcome.

Incorrect Answers

A:

Expect Ethernet carrier up to guarantee the routed neighbor remains usable. Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Use the controlled remediation: set supported timers and validate both real outage detection and false-positive rates.

B:

Assume BFD sessions automatically replace all routing protocol path selection. Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Use the controlled remediation: set supported timers and validate both real outage detection and false-positive rates.

C:

Configure the minimum possible timers without checking hardware and topology stability. Overly aggressive BFD timers can trigger flaps or load devices beyond their control-plane capacity. Use the controlled remediation: set supported timers and validate both real outage detection and false-positive rates.

Designing Cisco Enterprise Networks (ENSLD) (300-420) Practice Tests