cert
cert-1
cert-2

Pass Cisco 300-420 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
300-420 Exam - Verified By Experts
300-420 Premium Bundle
$29.98

300-420 Premium Bundle

$79.99
$109.97
  • Premium File 416 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 75 Video Lectures
  • Study Guide 751 Pages
 
$109.97
$79.99
accept 33 downloads in last 7 days
block-screenshots
Purchase Cisco 300-420 Exam Training Products Individually
Cisco 300-420 Premium File
Premium File 416 Q&A
$76.99$69.99
Cisco 300-420 Video Training Course
Training Course 75 Lectures
$21.99 $19.99
Cisco 300-420 PDF Study Guide
Study Guide 751 Pages
$21.99 $19.99
Cisco 300-420 Practice Test 10

Question 90

An edge region wants a smaller database yet must advertise a locally connected external prefix upstream. The observed fault is: Configuring a standard stub area when local redistribution is needed can suppress those external routes. What action most directly restores and validates the intended state?

  1. The controlled recovery is to assume changing the OSPF hello interval enables NSSA translation.
  2. The controlled recovery is to use the correct area type and redistribution control then verify Type-7 and translated reachability.
  3. The controlled recovery is to set an ordinary stub area yet expect its ASBR to originate external Type-5 LSAs.
  4. The controlled recovery is to redistribute every external prefix in every area for simplicity.

Explanation

Correct Answer

B:

OSPF NSSA permits selected local external advertisements with Type-7 LSA translation at an appropriate ABR. Relevant evidence includes area type, NSSA Type-7 advertisements, ABR translation and installed external prefixes.

Incorrect Answers

A:

Assume changing the OSPF hello interval enables NSSA translation. Configuring a standard stub area when local redistribution is needed can suppress those external routes. Use the controlled remediation: use the correct area type and redistribution control then verify Type-7 and translated reachability.

C:

Set an ordinary stub area yet expect its ASBR to originate external Type-5 LSAs. Configuring a standard stub area when local redistribution is needed can suppress those external routes. Use the controlled remediation: use the correct area type and redistribution control then verify Type-7 and translated reachability.

D:

Redistribute every external prefix in every area for simplicity. Configuring a standard stub area when local redistribution is needed can suppress those external routes. Use the controlled remediation: use the correct area type and redistribution control then verify Type-7 and translated reachability.

Question 91

A shared Ethernet OSPF segment has many routers and adjacency scaling is poor because DR priority was never planned. What is the most defensible configuration decision?

  1. Choose appropriately capable DR and BDR candidates through the OSPF interface priority and network design.
  2. Force a resource-constrained edge router as sole DR without capacity review.
  3. Assume any new higher priority router automatically preempts an existing healthy DR.
  4. Use switch MAC addresses instead of OSPF interface priority for DR planning.

Explanation

Correct Answer

A:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. This is the specific corrective action for OSPF multiaccess DR election design.

Incorrect Answers

B:

Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. This change targets the wrong mechanism for OSPF multiaccess DR election design.

C:

Assume any new higher priority router automatically preempts an existing healthy DR. OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Instead inspect OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

D:

Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Use switch MAC addresses instead of OSPF interface priority for DR planning.

Question 92

A shared Ethernet OSPF segment has many routers and adjacency scaling is poor because DR priority was never planned. Which evidence BEST confirms the actual technical behavior?

  1. A feature-license screenshot without the required design or acceptance tests.
  2. OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.
  3. A marketing claim without measured routing, capacity or failure-domain evidence.
  4. A hostname inventory without effective configuration or operational measurements.

Explanation

Correct Answer

B:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. This evidence observes the actual OSPF multiaccess DR election design mechanism and its result.

Incorrect Answers

A:

This observation alone cannot establish OSPF multiaccess DR election design. OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment.

C:

This observation alone cannot establish OSPF multiaccess DR election design. The decisive evidence instead includes OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

D:

This observation alone cannot establish OSPF multiaccess DR election design. A hostname inventory without effective configuration or operational measurements.

Question 93

A shared Ethernet OSPF segment has many routers and adjacency scaling is poor because DR priority was never planned. What networking or enterprise network design concept best explains this scenario?

  1. Any single device automatically guarantees high availability for every site.
  2. Encryption and segmentation are identical mechanisms and can replace each other.
  3. OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment.
  4. Cloud connectivity automatically removes any requirement for routing or policy.

Explanation

Correct Answer

C:

This is why the appropriate action is choose appropriately capable DR and BDR candidates through the OSPF interface priority and network design. Confirm it with OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

Incorrect Answers

A:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for OSPF multiaccess DR election design. The relevant rule is OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Verify using OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

B:

Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for OSPF multiaccess DR election design. The relevant rule is OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Verify using OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

D:

Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for OSPF multiaccess DR election design. The relevant rule is OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Verify using OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

Question 94

A shared Ethernet OSPF segment has many routers and adjacency scaling is poor because DR priority was never planned. Suppose the operator instead makes this incorrect change: Force a resource-constrained edge router as sole DR without capacity review. Which resulting fault should the reviewer identify?

  1. The only issue is an inaccurate hostname while traffic paths are unaffected.
  2. A healthy unrelated system proves the intended failure domain is protected.
  3. The failure is entirely cosmetic because all control-plane changes are harmless.
  4. Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior.

Explanation

Correct Answer

D:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. This explains why the proposed shortcut does not solve OSPF multiaccess DR election design.

Incorrect Answers

A:

The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Check OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

B:

A healthy unrelated system proves the intended failure domain is protected. The actual failure is treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Check OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

C:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Check OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

Question 95

A shared Ethernet OSPF segment has many routers and adjacency scaling is poor because DR priority was never planned. The observed fault is: Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. How should the issue be corrected and verified?

  1. Correct DR candidate priorities and validate elections and neighbor states in a safe window.
  2. Assume any new higher priority router automatically preempts an existing healthy DR.
  3. Use switch MAC addresses instead of OSPF interface priority for DR planning.
  4. Force a resource-constrained edge router as sole DR without capacity review.

Explanation

Correct Answer

A:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. This corrects the described failure and provides a verifiable outcome.

Incorrect Answers

B:

Assume any new higher priority router automatically preempts an existing healthy DR. Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Use the controlled remediation: correct DR candidate priorities and validate elections and neighbor states in a safe window.

C:

Use switch MAC addresses instead of OSPF interface priority for DR planning. Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Use the controlled remediation: correct DR candidate priorities and validate elections and neighbor states in a safe window.

D:

Force a resource-constrained edge router as sole DR without capacity review. Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Use the controlled remediation: correct DR candidate priorities and validate elections and neighbor states in a safe window.

Question 96

An access-distribution segment needs a stable designated router on a suitable device rather than random election by router ID. What is the BEST supported implementation or corrective action?

  1. For this enterprise design, the architect should choose appropriately capable DR and BDR candidates through the OSPF interface priority and network design.
  2. For this enterprise design, the architect should assume any new higher priority router automatically preempts an existing healthy DR.
  3. For this enterprise design, the architect should use switch MAC addresses instead of OSPF interface priority for DR planning.
  4. For this enterprise design, the architect should force a resource-constrained edge router as sole DR without capacity review.

Explanation

Correct Answer

A:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Confirm the result using OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

Incorrect Answers

B:

Assume any new higher priority router automatically preempts an existing healthy DR. OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Instead inspect OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

C:

Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior.

D:

Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. The relevant action is choose appropriately capable DR and BDR candidates through the OSPF interface priority and network design.

Question 97

An access-distribution segment needs a stable designated router on a suitable device rather than random election by router ID. What should the operator inspect to verify the result?

  1. Inspect the following evidence: an old network diagram with no current route, policy, or redundancy state.
  2. Inspect the following evidence: OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.
  3. Inspect the following evidence: a feature-license screenshot without the required design or acceptance tests.
  4. Inspect the following evidence: a marketing claim without measured routing, capacity or failure-domain evidence.

Explanation

Correct Answer

B:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. The intended procedure is choose appropriately capable DR and BDR candidates through the OSPF interface priority and network design.

Incorrect Answers

A:

This observation alone cannot establish OSPF multiaccess DR election design. In this case, an access-distribution segment needs a stable designated router on a suitable device rather than random election by router ID.

C:

This observation alone cannot establish OSPF multiaccess DR election design. A feature-license screenshot without the required design or acceptance tests.

D:

This observation alone cannot establish OSPF multiaccess DR election design. A marketing claim without measured routing, capacity or failure-domain evidence.

Question 98

An access-distribution segment needs a stable designated router on a suitable device rather than random election by router ID. Which technical statement is MOST accurate for this situation?

  1. The relevant principle is that cloud connectivity automatically removes any requirement for routing or policy.
  2. The relevant principle is that any single device automatically guarantees high availability for every site.
  3. The relevant principle is that a longer IP prefix is always less specific than the default route.
  4. The relevant principle is that OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment.

Explanation

Correct Answer

D:

This is why the appropriate action is choose appropriately capable DR and BDR candidates through the OSPF interface priority and network design.

Incorrect Answers

A:

Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for OSPF multiaccess DR election design. The relevant rule is OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Verify using OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

B:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for OSPF multiaccess DR election design. The relevant rule is OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Verify using OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

C:

A longer IP prefix is always less specific than the default route. This is an incorrect generalization for OSPF multiaccess DR election design. The relevant rule is OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Verify using OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

Question 99

An access-distribution segment needs a stable designated router on a suitable device rather than random election by router ID. Suppose the operator instead makes this incorrect change: Force a resource-constrained edge router as sole DR without capacity review. What weakness does the mistaken approach introduce?

  1. The resulting technical fault is that the failure is entirely cosmetic because all control-plane changes are harmless.
  2. The resulting technical fault is that treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior.
  3. The resulting technical fault is that collecting telemetry originally caused the missing route or service outage.
  4. The resulting technical fault is that a healthy unrelated system proves the intended failure domain is protected.

Explanation

Correct Answer

B:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. The right response is choose appropriately capable DR and BDR candidates through the OSPF interface priority and network design.

Incorrect Answers

A:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Check OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

C:

Collecting telemetry originally caused the missing route or service outage. The actual failure is treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Check OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

D:

A healthy unrelated system proves the intended failure domain is protected. The actual failure is treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Check OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

Question 100

An access-distribution segment needs a stable designated router on a suitable device rather than random election by router ID. The observed fault is: Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Which recovery is BEST once this fault is identified?

  1. The controlled recovery is to use switch MAC addresses instead of OSPF interface priority for DR planning.
  2. The controlled recovery is to force a resource-constrained edge router as sole DR without capacity review.
  3. The controlled recovery is to assume any new higher priority router automatically preempts an existing healthy DR.
  4. The controlled recovery is to correct DR candidate priorities and validate elections and neighbor states in a safe window.

Explanation

Correct Answer

D:

OSPF broadcast-network DR and BDR election reduces full-mesh adjacency requirements among routers on that segment. Relevant evidence includes OSPF interface network type, priority, DR and BDR state, neighbor adjacency count.

Incorrect Answers

A:

Use switch MAC addresses instead of OSPF interface priority for DR planning. Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Use the controlled remediation: correct DR candidate priorities and validate elections and neighbor states in a safe window.

B:

Force a resource-constrained edge router as sole DR without capacity review. Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Use the controlled remediation: correct DR candidate priorities and validate elections and neighbor states in a safe window.

C:

Assume any new higher priority router automatically preempts an existing healthy DR. Treating every broadcast router as fully adjacent to every other can obscure scaling and failure behavior. Use the controlled remediation: correct DR candidate priorities and validate elections and neighbor states in a safe window.

Designing Cisco Enterprise Networks (ENSLD) (300-420) Practice Tests