ServiceNow CIS-DF Practice Test 13
Question 120
A vulnerability result cannot find its affected server CI. What should transformation address?
- Ingest equipment facts through IRE and preserve risk ratings in governed security records.
- Use governed compliance references associated with appropriate CSDM objects.
- Map the scanner's asset identity to the canonical affected CI.
- Maintain one authoritative regulation record with service associations.
Explanation
Correct Answer
C:Correct finding-to-CI references enable downstream impact and remediation.
Incorrect Answers
A:Different fact types have separate schemas and ownership. Correct finding-to-CI references enable downstream impact and remediation.
B:A logical compliance requirement belongs to the relevant service context. Correct finding-to-CI references enable downstream impact and remediation.
D:Controlled references prevent fragmented copies of compliance facts. Correct finding-to-CI references enable downstream impact and remediation.
Question 121
A service offering requires business-level evidence of privacy compliance. Where should it be linked?
- Reconcile external aliases to stable CMDB CI identities.
- Ingest equipment facts through IRE and preserve risk ratings in governed security records.
- Attach the evidence or control to the relevant service offering object.
- Verify those exact non-CMDB tables are supported by the chosen IRE or ETL path.
Explanation
Correct Answer
C:Business service obligations should not be attached arbitrarily to one host.
Incorrect Answers
A:Canonical CI references survive identifier changes in source systems. Business service obligations should not be attached arbitrarily to one host.
B:Different fact types have separate schemas and ownership. Business service obligations should not be attached arbitrarily to one host.
D:Some non-CMDB tables are compatible; universal support should not be assumed. Business service obligations should not be attached arbitrarily to one host.
Question 122
An integration classifies each regulation code as a network device. What should change?
- Verify those exact non-CMDB tables are supported by the chosen IRE or ETL path.
- Map the code to a compliance object rather than to infrastructure.
- Maintain one authoritative regulation record with service associations.
- Reconcile external aliases to stable CMDB CI identities.
Explanation
Correct Answer
B:Security classification data and discoverable CIs are not interchangeable.
Incorrect Answers
A:Some non-CMDB tables are compatible; universal support should not be assumed. Security classification data and discoverable CIs are not interchangeable.
C:Controlled references prevent fragmented copies of compliance facts. Security classification data and discoverable CIs are not interchangeable.
D:Canonical CI references survive identifier changes in source systems. Security classification data and discoverable CIs are not interchangeable.
Question 123
A scanner changes its external device IDs in a vendor migration. What preserves findings?
- Reconcile external aliases to stable CMDB CI identities.
- Use governed compliance references associated with appropriate CSDM objects.
- Maintain one authoritative regulation record with service associations.
- Attach the evidence or control to the relevant service offering object.
Explanation
Correct Answer
A:Canonical CI references survive identifier changes in source systems.
Incorrect Answers
B:A logical compliance requirement belongs to the relevant service context. Canonical CI references survive identifier changes in source systems.
C:Controlled references prevent fragmented copies of compliance facts. Canonical CI references survive identifier changes in source systems.
D:Business service obligations should not be attached arbitrarily to one host. Canonical CI references survive identifier changes in source systems.
Question 124
One feed reports both device serials and risk scores. How should these be modeled?
- Map the scanner's asset identity to the canonical affected CI.
- Attach the evidence or control to the relevant service offering object.
- Maintain one authoritative regulation record with service associations.
- Ingest equipment facts through IRE and preserve risk ratings in governed security records.
Explanation
Correct Answer
D:Different fact types have separate schemas and ownership.
Incorrect Answers
A:Correct finding-to-CI references enable downstream impact and remediation. Different fact types have separate schemas and ownership.
B:Business service obligations should not be attached arbitrarily to one host. Different fact types have separate schemas and ownership.
C:Controlled references prevent fragmented copies of compliance facts. Different fact types have separate schemas and ownership.
Question 125
A nightly connector sends changes only; a CI is absent from today's batch. What does absence mean?
- Examine sample class mappings and IRE identification outcomes.
- Compare execution logs with CMDB 360 source histories.
- Do not infer decommissioning from a missing incremental-change row.
- Agree on shared identification and per-attribute reconciliation precedence.
Explanation
Correct Answer
C:A delta feed is not an authoritative complete inventory.
Incorrect Answers
A:Both wrong class mapping and weak identity keys can inflate records. A delta feed is not an authoritative complete inventory.
B:Trigger success does not prove useful canonical CI updates occurred. A delta feed is not an authoritative complete inventory.
D:Multiple feeds must converge on one CI with controlled source authority. A delta feed is not an authoritative complete inventory.
Question 126
A connector has been offline for three nights. What should precede CI cleanup?
- Examine sample class mappings and IRE identification outcomes.
- Investigate source failures separately from staleness and retirement eligibility.
- Agree on shared identification and per-attribute reconciliation precedence.
- Disable the old schedule after verifying connector IRE identity matches.
Explanation
Correct Answer
B:An acquisition outage must not cause false destructive lifecycle actions.
Incorrect Answers
A:Both wrong class mapping and weak identity keys can inflate records. An acquisition outage must not cause false destructive lifecycle actions.
C:Multiple feeds must converge on one CI with controlled source authority. An acquisition outage must not cause false destructive lifecycle actions.
D:Parallel loaders can race to write and duplicate data. An acquisition outage must not cause false destructive lifecycle actions.
Question 127
An import sends blank serial numbers over known values. What control is warranted?
- Validate and reject malformed critical source attributes before IRE.
- Give the malformed source unrestricted higher-priority write authority so that its blank serials replace existing identified values.
- Do not infer decommissioning from a missing incremental-change row.
- Investigate source failures separately from staleness and retirement eligibility.
Explanation
Correct Answer
A:Empty identifiers degrade matching and can corrupt existing data.
Incorrect Answers
B:Reconciliation authority cannot justify corrupting a reliable identity attribute with a blank. Validate the feed before IRE and preserve authoritative identifier values.
C:A delta feed is not an authoritative complete inventory. Empty identifiers degrade matching and can corrupt existing data.
D:An acquisition outage must not cause false destructive lifecycle actions. Empty identifiers degrade matching and can corrupt existing data.
Question 128
A vendor changes enumerated lifecycle values and CIs receive incorrect statuses. What should be modified?
- Agree on shared identification and per-attribute reconciliation precedence.
- Disable the old schedule after verifying connector IRE identity matches.
- Examine sample class mappings and IRE identification outcomes.
- Update and regression-test source status transformations.
Explanation
Correct Answer
D:Source vocabulary may differ from standardized CI lifecycle values.
Incorrect Answers
A:Multiple feeds must converge on one CI with controlled source authority. Source vocabulary may differ from standardized CI lifecycle values.
B:Parallel loaders can race to write and duplicate data. Source vocabulary may differ from standardized CI lifecycle values.
C:Both wrong class mapping and weak identity keys can inflate records. Source vocabulary may differ from standardized CI lifecycle values.
Question 129
A bulk load abruptly doubles the router count. What should be inspected?
- Update and regression-test source status transformations.
- Compare execution logs with CMDB 360 source histories.
- Examine sample class mappings and IRE identification outcomes.
- Do not infer decommissioning from a missing incremental-change row.
Explanation
Correct Answer
C:Both wrong class mapping and weak identity keys can inflate records.
Incorrect Answers
A:Source vocabulary may differ from standardized CI lifecycle values. Both wrong class mapping and weak identity keys can inflate records.
B:Trigger success does not prove useful canonical CI updates occurred. Both wrong class mapping and weak identity keys can inflate records.
D:A delta feed is not an authoritative complete inventory. Both wrong class mapping and weak identity keys can inflate records.
Question 130
Import schedules succeed but CMDB 360 shows no recent source contributions. What should be correlated?
- Disable the old schedule after verifying connector IRE identity matches.
- Compare execution logs with CMDB 360 source histories.
- Do not infer decommissioning from a missing incremental-change row.
- Examine sample class mappings and IRE identification outcomes.
Explanation
Correct Answer
B:Trigger success does not prove useful canonical CI updates occurred.
Incorrect Answers
A:Parallel loaders can race to write and duplicate data. Trigger success does not prove useful canonical CI updates occurred.
C:A delta feed is not an authoritative complete inventory. Trigger success does not prove useful canonical CI updates occurred.
D:Both wrong class mapping and weak identity keys can inflate records. Trigger success does not prove useful canonical CI updates occurred.