Question 380

An enterprise change review is deciding whether its response to blanking and airflow integrity has been justified. The fictional case facts are: A customer removes a chassis filler panel to make temporary cable routing easier. The review needs three separate components: a sound FlashArray administration principle, a scoped authorized response, and an independent measurable success check. Choose EXACTLY THREE statements that fulfill those roles.

  1. All unused openings are protected and thermal sensors remain within documented operational limits.
  2. An independent operator can trace each unit and service cable without relying on memory.
  3. Reroute and secure cabling with supported lengths and defined service clearance.
  4. Required module blanks and cabinet airflow controls are functional parts of a supported chassis installation.
  5. Fit the approved blanking pieces and restore the intended airflow path before production load.
  6. New-array software changes require an authorized release and verified installation medium for the hardware generation.

Explanation

Correct Answer

A:

All unused openings are protected and thermal sensors remain within documented operational limits. This shows whether the scoped response worked: Fit the approved blanking pieces and restore the intended airflow path before production load. A customer removes a chassis filler panel to make temporary cable routing easier. The result should be supported by this evidence: Inspect populated slots, blanking plates and model-specific thermal guidance.

D:

Required module blanks and cabinet airflow controls are functional parts of a supported chassis installation. A customer removes a chassis filler panel to make temporary cable routing easier. The comparison to make is: Inspect populated slots, blanking plates and model-specific thermal guidance. That principle leads to a bounded response: Fit the approved blanking pieces and restore the intended airflow path before production load.

E:

A customer removes a chassis filler panel to make temporary cable routing easier. Fit the approved blanking pieces and restore the intended airflow path before production load. Verify the change by checking: All unused openings are protected and thermal sensors remain within documented operational limits. The action implements this principle: Required module blanks and cabinet airflow controls are functional parts of a supported chassis installation.

Incorrect Answers

B:

An independent operator can trace each unit and service cable without relying on memory. That outcome tests a separate rack labels and asset identification concern, not whether the reported problem is fixed: A customer removes a chassis filler panel to make temporary cable routing easier. A directly relevant result would be: All unused openings are protected and thermal sensors remain within documented operational limits. The acceptance test needs evidence from: Inspect populated slots, blanking plates and model-specific thermal guidance.

C:

Reroute and secure cabling with supported lengths and defined service clearance. That change targets a separate cable strain relief and service loops concern; the unresolved issue is: A customer removes a chassis filler panel to make temporary cable routing easier. The scoped response is: Fit the approved blanking pieces and restore the intended airflow path before production load. The action should implement: Required module blanks and cabinet airflow controls are functional parts of a supported chassis installation.

F:

New-array software changes require an authorized release and verified installation medium for the hardware generation. That is a separate purity software staging on newly installed hardware concern; it does not explain the case: A customer removes a chassis filler panel to make temporary cable routing easier. The governing distinction here is: Required module blanks and cabinet airflow controls are functional parts of a supported chassis installation. The governing rule must instead lead to: Fit the approved blanking pieces and restore the intended airflow path before production load.

Question 381

A hypothetical FlashArray operations change concerns redundant power supply physical verification in the Installation area. The change or incident record reports: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. Before modifying any FlashArray object, the administrator must identify the defensible operating principle. Which ONE governing principle directly applies? Choose ONE answer.

  1. Initial local console access must use the vendor-approved method and protect privileged setup credentials.
  2. A chassis must be lifted and seated by trained staff with suitable handling equipment, not balanced on temporary supports.
  3. Cables should be sized, routed and labeled so they remain secure during controller and shelf service.
  4. Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

Explanation

Correct Answer

D:

Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The comparison to make is: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Incorrect Answers

A:

Initial local console access must use the vendor-approved method and protect privileged setup credentials. That is a separate controller initialization through approved console concern; it does not explain the case: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

B:

A chassis must be lifted and seated by trained staff with suitable handling equipment, not balanced on temporary supports. That is a separate load-assisted chassis mounting concern; it does not explain the case: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

C:

Cables should be sized, routed and labeled so they remain secure during controller and shelf service. That is a separate cable strain relief and service loops concern; it does not explain the case: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

Question 382

During FlashArray administration concerning redundant power supply physical verification, an operator reviews this fictional service issue: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. Several explanations remain plausible until the relevant configuration and runtime evidence are checked. Which ONE specific evidence package should the administrator examine before deciding the change or diagnosis? Choose ONE answer.

  1. Check safe-lift plan, component weights, rack mounting instructions and the available lifting device.
  2. Inspect PSU status, feed labels, power alarms and power-circuit mapping.
  3. Inspect cable bend radii, rear service paths, connector tension and port labeling.
  4. Check console-displayed configuration, network worksheet and direct ping or route tests from approved sources.

Explanation

Correct Answer

B:

A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. Inspect PSU status, feed labels, power alarms and power-circuit mapping. These observations test the rule: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

Incorrect Answers

A:

Check safe-lift plan, component weights, rack mounting instructions and the available lifting device. Those checks address a separate load-assisted chassis mounting concern, not the specific finding: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

C:

Inspect cable bend radii, rear service paths, connector tension and port labeling. Those checks address a separate cable strain relief and service loops concern, not the specific finding: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

D:

Check console-displayed configuration, network worksheet and direct ping or route tests from approved sources. Those checks address a separate ip initialization and subnet masks concern, not the specific finding: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Question 383

A change manager requests a safe and limited FlashArray response to a Installation problem involving redundant power supply physical verification. The reported situation is: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The change must follow the observed facts, preserve recovery capability and avoid unrelated service impact. Which ONE bounded administrative action best matches this case? Choose ONE answer.

  1. Establish a secured console session using the correct guide and keep initial credentials under controlled custody.
  2. Correct an unseated module or miswired power connection under approved electrical procedures.
  3. Rebuild the shelf connection map using the supported sequence after a documented outage review.
  4. Create or correct authorized host objects and mapping after identity verification.

Explanation

Correct Answer

B:

A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. Correct an unseated module or miswired power connection under approved electrical procedures. Verify the change by checking: PSU status remains healthy and a controlled feed-loss check preserves required redundancy.

Incorrect Answers

A:

Establish a secured console session using the correct guide and keep initial credentials under controlled custody. That change targets a separate controller initialization through approved console concern; the unresolved issue is: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures.

C:

Rebuild the shelf connection map using the supported sequence after a documented outage review. That change targets a separate directflash shelf supported topology concern; the unresolved issue is: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures.

D:

Create or correct authorized host objects and mapping after identity verification. That change targets a separate host and host-group mapping safety concern; the unresolved issue is: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures.

Question 384

Two independent FlashArray administrator reviewers discuss redundant power supply physical verification. Their case record says: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. One requires diagnostic evidence that can distinguish the actual issue from lookalike symptoms; the other requires a limited and approved remediation. Choose EXACTLY TWO statements that jointly provide those roles.

  1. Inspect PSU status, feed labels, power alarms and power-circuit mapping.
  2. Compare currently installed Purity version, supported target image and downloaded package checksum.
  3. Read hardware labels, model-specific component map and matching supported procedure.
  4. Correct an unseated module or miswired power connection under approved electrical procedures.
  5. Reroute and secure cabling with supported lengths and defined service clearance.

Explanation

Correct Answer

A:

A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. Inspect PSU status, feed labels, power alarms and power-circuit mapping. These observations test the rule: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. The evidence supports this limited action: Correct an unseated module or miswired power connection under approved electrical procedures.

D:

A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. Correct an unseated module or miswired power connection under approved electrical procedures. Verify the change by checking: PSU status remains healthy and a controlled feed-loss check preserves required redundancy. The change should follow this observation: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Incorrect Answers

B:

Compare currently installed Purity version, supported target image and downloaded package checksum. Those checks address a separate purity software staging on newly installed hardware concern, not the specific finding: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping. The relevant observation must instead support: Correct an unseated module or miswired power connection under approved electrical procedures.

C:

Read hardware labels, model-specific component map and matching supported procedure. Those checks address a separate chassis and controller hardware identity concern, not the specific finding: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping. The relevant observation must instead support: Correct an unseated module or miswired power connection under approved electrical procedures.

E:

Reroute and secure cabling with supported lengths and defined service clearance. That change targets a separate cable strain relief and service loops concern; the unresolved issue is: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures. The authorized change must instead follow: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Question 385

An enterprise change review is deciding whether its response to redundant power supply physical verification has been justified. The fictional case facts are: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The review needs three separate components: a sound FlashArray administration principle, a scoped authorized response, and an independent measurable success check. Choose EXACTLY THREE statements that fulfill those roles.

  1. Correct an unseated module or miswired power connection under approved electrical procedures.
  2. The installation inspection confirms a secure mount with no improvised bracing or damaged rails.
  3. Complete the approved registration workflow or document the supported restricted-site exception.
  4. PSU status remains healthy and a controlled feed-loss check preserves required redundancy.
  5. Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.
  6. Physical chassis, shelf and cable labeling should unambiguously match asset, service and support records.

Explanation

Correct Answer

A:

A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. Correct an unseated module or miswired power connection under approved electrical procedures. Verify the change by checking: PSU status remains healthy and a controlled feed-loss check preserves required redundancy. The action implements this principle: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

D:

PSU status remains healthy and a controlled feed-loss check preserves required redundancy. This shows whether the scoped response worked: Correct an unseated module or miswired power connection under approved electrical procedures. A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The result should be supported by this evidence: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

E:

Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The comparison to make is: Inspect PSU status, feed labels, power alarms and power-circuit mapping. That principle leads to a bounded response: Correct an unseated module or miswired power connection under approved electrical procedures.

Incorrect Answers

B:

The installation inspection confirms a secure mount with no improvised bracing or damaged rails. That outcome tests a separate load-assisted chassis mounting concern, not whether the reported problem is fixed: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. A directly relevant result would be: PSU status remains healthy and a controlled feed-loss check preserves required redundancy. The acceptance test needs evidence from: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

C:

Complete the approved registration workflow or document the supported restricted-site exception. That change targets a separate pure1 registration and telemetry authorization concern; the unresolved issue is: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures. The action should implement: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

F:

Physical chassis, shelf and cable labeling should unambiguously match asset, service and support records. That is a separate rack labels and asset identification concern; it does not explain the case: A campus installer sees both PSU LEDs green although both supply cords lead to one PDU. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. The governing rule must instead lead to: Correct an unseated module or miswired power connection under approved electrical procedures.

Question 386

A hypothetical FlashArray operations change concerns redundant power supply physical verification in the Installation area. The change or incident record reports: A telecom warehouse's second controller displays a power redundancy warning after racking. Before modifying any FlashArray object, the administrator must identify the defensible operating principle. Which ONE governing principle directly applies? Choose ONE answer.

  1. Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.
  2. A shelf added at installation must be discovered and admitted using the supported hardware procedure and inventory identity.
  3. Registration for cloud telemetry must comply with customer policy and prove the intended network path works.
  4. Host access is production ready only when its approved multiple storage paths are visible and working.

Explanation

Correct Answer

A:

Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. A telecom warehouse's second controller displays a power redundancy warning after racking. The comparison to make is: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Incorrect Answers

B:

A shelf added at installation must be discovered and admitted using the supported hardware procedure and inventory identity. That is a separate directflash shelf admission and identity concern; it does not explain the case: A telecom warehouse's second controller displays a power redundancy warning after racking. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

C:

Registration for cloud telemetry must comply with customer policy and prove the intended network path works. That is a separate pure1 registration and telemetry authorization concern; it does not explain the case: A telecom warehouse's second controller displays a power redundancy warning after racking. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

D:

Host access is production ready only when its approved multiple storage paths are visible and working. That is a separate multipath configuration after presentation concern; it does not explain the case: A telecom warehouse's second controller displays a power redundancy warning after racking. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

Question 387

During FlashArray administration concerning redundant power supply physical verification, an operator reviews this fictional service issue: A telecom warehouse's second controller displays a power redundancy warning after racking. Several explanations remain plausible until the relevant configuration and runtime evidence are checked. Which ONE specific evidence package should the administrator examine before deciding the change or diagnosis? Choose ONE answer.

  1. Check safe-lift plan, component weights, rack mounting instructions and the available lifting device.
  2. Inspect PSU status, feed labels, power alarms and power-circuit mapping.
  3. Compare host IQNs or WWPNs, access groups, intended volume mapping and application-owner approvals.
  4. Compare optical module specifications, connector type, speed settings and live link diagnostics.

Explanation

Correct Answer

B:

A telecom warehouse's second controller displays a power redundancy warning after racking. Inspect PSU status, feed labels, power alarms and power-circuit mapping. These observations test the rule: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

Incorrect Answers

A:

Check safe-lift plan, component weights, rack mounting instructions and the available lifting device. Those checks address a separate load-assisted chassis mounting concern, not the specific finding: A telecom warehouse's second controller displays a power redundancy warning after racking. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

C:

Compare host IQNs or WWPNs, access groups, intended volume mapping and application-owner approvals. Those checks address a separate host and host-group mapping safety concern, not the specific finding: A telecom warehouse's second controller displays a power redundancy warning after racking. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

D:

Compare optical module specifications, connector type, speed settings and live link diagnostics. Those checks address a separate ethernet optics matching concern, not the specific finding: A telecom warehouse's second controller displays a power redundancy warning after racking. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Question 388

A change manager requests a safe and limited FlashArray response to a Installation problem involving redundant power supply physical verification. The reported situation is: A telecom warehouse's second controller displays a power redundancy warning after racking. The change must follow the observed facts, preserve recovery capability and avoid unrelated service impact. Which ONE bounded administrative action best matches this case? Choose ONE answer.

  1. Correct an unseated module or miswired power connection under approved electrical procedures.
  2. Rotate or disable temporary credentials and establish least-privilege named ownership after initial setup.
  3. Correct any specific physical mismatch and rerun the vendor-aligned connection verification.
  4. Correct FC patching and zoning dependencies without changing unrelated production initiators.

Explanation

Correct Answer

A:

A telecom warehouse's second controller displays a power redundancy warning after racking. Correct an unseated module or miswired power connection under approved electrical procedures. Verify the change by checking: PSU status remains healthy and a controlled feed-loss check preserves required redundancy.

Incorrect Answers

B:

Rotate or disable temporary credentials and establish least-privilege named ownership after initial setup. That change targets a separate privileged local account handoff concern; the unresolved issue is: A telecom warehouse's second controller displays a power redundancy warning after racking. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures.

C:

Correct any specific physical mismatch and rerun the vendor-aligned connection verification. That change targets a separate post-cabling controller and shelf link verification concern; the unresolved issue is: A telecom warehouse's second controller displays a power redundancy warning after racking. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures.

D:

Correct FC patching and zoning dependencies without changing unrelated production initiators. That change targets a separate fibre channel target-port cabling concern; the unresolved issue is: A telecom warehouse's second controller displays a power redundancy warning after racking. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures.

Question 389

Two independent FlashArray administrator reviewers discuss redundant power supply physical verification. Their case record says: A telecom warehouse's second controller displays a power redundancy warning after racking. One requires diagnostic evidence that can distinguish the actual issue from lookalike symptoms; the other requires a limited and approved remediation. Choose EXACTLY TWO statements that jointly provide those roles.

  1. Compare host IQNs or WWPNs, access groups, intended volume mapping and application-owner approvals.
  2. Check console-displayed configuration, network worksheet and direct ping or route tests from approved sources.
  3. Correct an unseated module or miswired power connection under approved electrical procedures.
  4. Replace unsupported optics with approved compatible components before enabling target traffic.
  5. Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Explanation

Correct Answer

C:

A telecom warehouse's second controller displays a power redundancy warning after racking. Correct an unseated module or miswired power connection under approved electrical procedures. Verify the change by checking: PSU status remains healthy and a controlled feed-loss check preserves required redundancy. The change should follow this observation: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

E:

A telecom warehouse's second controller displays a power redundancy warning after racking. Inspect PSU status, feed labels, power alarms and power-circuit mapping. These observations test the rule: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. The evidence supports this limited action: Correct an unseated module or miswired power connection under approved electrical procedures.

Incorrect Answers

A:

Compare host IQNs or WWPNs, access groups, intended volume mapping and application-owner approvals. Those checks address a separate host and host-group mapping safety concern, not the specific finding: A telecom warehouse's second controller displays a power redundancy warning after racking. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping. The relevant observation must instead support: Correct an unseated module or miswired power connection under approved electrical procedures.

B:

Check console-displayed configuration, network worksheet and direct ping or route tests from approved sources. Those checks address a separate ip initialization and subnet masks concern, not the specific finding: A telecom warehouse's second controller displays a power redundancy warning after racking. The useful observations are: Inspect PSU status, feed labels, power alarms and power-circuit mapping. The relevant observation must instead support: Correct an unseated module or miswired power connection under approved electrical procedures.

D:

Replace unsupported optics with approved compatible components before enabling target traffic. That change targets a separate ethernet optics matching concern; the unresolved issue is: A telecom warehouse's second controller displays a power redundancy warning after racking. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures. The authorized change must instead follow: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Question 390

An enterprise change review is deciding whether its response to redundant power supply physical verification has been justified. The fictional case facts are: A telecom warehouse's second controller displays a power redundancy warning after racking. The review needs three separate components: a sound FlashArray administration principle, a scoped authorized response, and an independent measurable success check. Choose EXACTLY THREE statements that fulfill those roles.

  1. Install only the approved rail hardware after confirming the cabinet's mounting standard.
  2. Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.
  3. Correct an unseated module or miswired power connection under approved electrical procedures.
  4. PSU status remains healthy and a controlled feed-loss check preserves required redundancy.
  5. Initial local console access must use the vendor-approved method and protect privileged setup credentials.
  6. The customer can authenticate with intended roles, while temporary installer credentials are no longer active.

Explanation

Correct Answer

B:

Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. A telecom warehouse's second controller displays a power redundancy warning after racking. The comparison to make is: Inspect PSU status, feed labels, power alarms and power-circuit mapping. That principle leads to a bounded response: Correct an unseated module or miswired power connection under approved electrical procedures.

C:

A telecom warehouse's second controller displays a power redundancy warning after racking. Correct an unseated module or miswired power connection under approved electrical procedures. Verify the change by checking: PSU status remains healthy and a controlled feed-loss check preserves required redundancy. The action implements this principle: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

D:

PSU status remains healthy and a controlled feed-loss check preserves required redundancy. This shows whether the scoped response worked: Correct an unseated module or miswired power connection under approved electrical procedures. A telecom warehouse's second controller displays a power redundancy warning after racking. The result should be supported by this evidence: Inspect PSU status, feed labels, power alarms and power-circuit mapping.

Incorrect Answers

A:

Install only the approved rail hardware after confirming the cabinet's mounting standard. That change targets a separate rail kit selection and orientation concern; the unresolved issue is: A telecom warehouse's second controller displays a power redundancy warning after racking. The scoped response is: Correct an unseated module or miswired power connection under approved electrical procedures. The action should implement: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed.

E:

Initial local console access must use the vendor-approved method and protect privileged setup credentials. That is a separate controller initialization through approved console concern; it does not explain the case: A telecom warehouse's second controller displays a power redundancy warning after racking. The governing distinction here is: Physical installation should verify each PSU is seated, powered and wired to the intended independent feed. The governing rule must instead lead to: Correct an unseated module or miswired power connection under approved electrical procedures.

F:

The customer can authenticate with intended roles, while temporary installer credentials are no longer active. That outcome tests a separate privileged local account handoff concern, not whether the reported problem is fixed: A telecom warehouse's second controller displays a power redundancy warning after racking. A directly relevant result would be: PSU status remains healthy and a controlled feed-loss check preserves required redundancy. The acceptance test needs evidence from: Inspect PSU status, feed labels, power alarms and power-circuit mapping.