Nokia 4A0-C03 Practice Test 61
Question 600
A planned link speed increase updates physical capacity but the advertised TE reservable bandwidth remains at its old lower limit, so new LSPs choose a longer route. After the approved repair, which outcome best demonstrates that this exact fault is resolved?
- The new LSP selects an eligible path under correctly advertised resource limits.
- The router switches the test LSP onto its valid facility bypass when the protected link fails.
- Only intended preemption occurs and protected service priorities match contracts.
- The authorized tunnel establishes across intended areas without bypassing resource constraints.
Explanation
Correct Answer
A:The acceptance measurement for this case is: The new LSP selects an eligible path under correctly advertised resource limits. It establishes that the intended remediation (“Update verified TE resource advertisements to match the supported, policy-approved reservable capacity”) was effective and can be corroborated by: Inspect CSPF excluded-link reasons and available resources for the target LSP.
Incorrect Answers
B:The alternative is directed at this separate case: A core LSP is marked protected, but the local repair node has no usable bypass tunnel for a failed transit link. The present incident is: A planned link speed increase updates physical capacity but the advertised TE reservable bandwidth remains at its old lower limit, so new LSPs choose a longer route. The pertinent verification is: Compare physical interface speed and configured reservable bandwidth on the link. The action or outcome to select here is: The new LSP selects an eligible path under correctly advertised resource limits.
C:This choice does not address the stated situation: A planned link speed increase updates physical capacity but the advertised TE reservable bandwidth remains at its old lower limit, so new LSPs choose a longer route. Its competing context is: A high-priority TE LSP reserves scarce link bandwidth and a lower-priority existing tunnel is preempted although both used to coexist. The relevant diagnostic is: Compare physical interface speed and configured reservable bandwidth on the link. The case-supported response is: The new LSP selects an eligible path under correctly advertised resource limits.
D:The alternative applies to another situation: A service tunnel crosses two IGP areas but an area border router lacks the planned TE visibility, preventing constrained signaling beyond the first area. The reported case instead states: A planned link speed increase updates physical capacity but the advertised TE reservable bandwidth remains at its old lower limit, so new LSPs choose a longer route. The distinguishing check is: Compare physical interface speed and configured reservable bandwidth on the link. The supported action or criterion is: The new LSP selects an eligible path under correctly advertised resource limits.
Question 601
A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. An operator needs a controlled repair. Which response is most appropriate?
- Restore the intended service administrative state after confirming maintenance authorization.
- Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.
- Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
- Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.
Explanation
Correct Answer
C:The fault stated in this case is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The specific corrective action is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants. Confirm it with: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The expected end-to-end outcome is: Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
Incorrect Answers
A:The alternative is directed at this separate case: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The present incident is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The pertinent verification is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The action or outcome to select here is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
B:This choice does not address the stated situation: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Its competing context is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The relevant diagnostic is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The case-supported response is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
D:These other facts could justify the alternative: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. They differ from the stated case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Test the distinction using: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The case-specific response is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
Question 602
A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)
- Capture synthetic frames at both access ports and compare VLAN tag presence.
- Compare the installed Epipe SAP configuration with the signed customer circuit inventory.
- Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame.
- Inspect service ID, far-end and signaling state at both Epipe endpoints.
- Inspect IES interface association and learned routes for the customer handoff.
Explanation
Correct Answers
B:This is a direct diagnostic for the reported fault: Compare the installed Epipe SAP configuration with the signed customer circuit inventory. A second independent check is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. Combined evidence distinguishes the fault before implementing: Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
C:This is a direct diagnostic for the reported fault: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. A second independent check is: Compare the installed Epipe SAP configuration with the signed customer circuit inventory. Combined evidence distinguishes the fault before implementing: Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
Incorrect Answers
A:This choice does not address the stated situation: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Its competing context is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The relevant diagnostic is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The case-supported response is: Compare the installed Epipe SAP configuration with the signed customer circuit inventory; and Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame.
D:The actual case evidence is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The proposed option addresses a different condition: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Confirm the distinction by checking: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The response supported by the evidence is: Compare the installed Epipe SAP configuration with the signed customer circuit inventory; and Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame.
E:The alternative is directed at this separate case: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. The present incident is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The pertinent verification is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The action or outcome to select here is: Compare the installed Epipe SAP configuration with the signed customer circuit inventory; and Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame.
Question 603
A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Which specific consequence explains why a repair is necessary?
- A healthy interface cannot carry private-wire traffic through a disabled service instance.
- A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.
- A link may be operational while mismatched tags cause the customer endpoint to reject frames.
- A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
Explanation
Correct Answer
D:The observed condition is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The principal operational or security impact is: A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries. The supported repair is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The reported case instead states: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The distinguishing check is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The supported action or criterion is: A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
B:These other facts could justify the alternative: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. They differ from the stated case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Test the distinction using: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The case-specific response is: A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
C:The actual case evidence is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The proposed option addresses a different condition: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Confirm the distinction by checking: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The response supported by the evidence is: A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
Question 604
A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)
- Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.
- Distinguish access ports and their SAPs from the provider's network-facing transport ports.
- Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
- Verify port ownership and change only the approved SAP under an isolated service test.
- Attach the approved IES interface to the proper global routed service context.
Explanation
Correct Answers
C:This is the required technical repair: Correct the specific customer SAP port and encapsulation binding without modifying other tenants. The separately necessary deployment safeguard is: Verify port ownership and change only the approved SAP under an isolated service test. Together they address: A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
D:This safeguard prevents unwanted collateral effects: Verify port ownership and change only the approved SAP under an isolated service test. Its complementary corrective change is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants. Both are required because: A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
Incorrect Answers
A:These other facts could justify the alternative: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. They differ from the stated case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Test the distinction using: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The case-specific response is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants; and Verify port ownership and change only the approved SAP under an isolated service test.
B:The actual case evidence is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The proposed option addresses a different condition: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Confirm the distinction by checking: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The response supported by the evidence is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants; and Verify port ownership and change only the approved SAP under an isolated service test.
E:The alternative applies to another situation: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. The reported case instead states: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The distinguishing check is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The supported action or criterion is: Correct the specific customer SAP port and encapsulation binding without modifying other tenants; and Verify port ownership and change only the approved SAP under an isolated service test.
Question 605
A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Which post-change observation is the strongest acceptance criterion?
- The authorized Epipe becomes operational and remote customer MAC traffic is restored.
- The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.
- The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.
- Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
Explanation
Correct Answer
D:The acceptance measurement for this case is: Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact. It establishes that the intended remediation (“Correct the specific customer SAP port and encapsulation binding without modifying other tenants”) was effective and can be corroborated by: Compare the installed Epipe SAP configuration with the signed customer circuit inventory.
Incorrect Answers
A:The actual case evidence is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The proposed option addresses a different condition: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Confirm the distinction by checking: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The response supported by the evidence is: Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
B:The alternative is directed at this separate case: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The present incident is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The pertinent verification is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The action or outcome to select here is: Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
C:This choice does not address the stated situation: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Its competing context is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The relevant diagnostic is: Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame. The case-supported response is: Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
Question 606
An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Which next technical step should the engineer prioritize?
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
- Diagnose the remote attachment status rather than changing the already healthy transport LSP.
- Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
- Distinguish access ports and their SAPs from the provider's network-facing transport ports.
Explanation
Correct Answer
D:The fault stated in this case is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The specific corrective action is: Distinguish access ports and their SAPs from the provider's network-facing transport ports. Confirm it with: Inspect actual SR OS port mode and the service attachment hierarchy. The expected end-to-end outcome is: The customer SAP attaches to the correct access port while core transport remains isolated.
Incorrect Answers
A:The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The pertinent verification is: Inspect actual SR OS port mode and the service attachment hierarchy. The action or outcome to select here is: Distinguish access ports and their SAPs from the provider's network-facing transport ports.
B:This choice does not address the stated situation: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect actual SR OS port mode and the service attachment hierarchy. The case-supported response is: Distinguish access ports and their SAPs from the provider's network-facing transport ports.
C:The alternative applies to another situation: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The reported case instead states: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The distinguishing check is: Inspect actual SR OS port mode and the service attachment hierarchy. The supported action or criterion is: Distinguish access ports and their SAPs from the provider's network-facing transport ports.
Question 607
An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Which TWO items of evidence should the engineer examine first? (Select TWO.)
- Inspect service OAM result and remote SAP policy drop counters together.
- Compare the physical circuit role with the Nokia service deployment diagram.
- Inspect pseudowire status TLVs and remote attachment-circuit alarms.
- Inspect actual SR OS port mode and the service attachment hierarchy.
- Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
Explanation
Correct Answers
B:This is a direct diagnostic for the reported fault: Compare the physical circuit role with the Nokia service deployment diagram. A second independent check is: Inspect actual SR OS port mode and the service attachment hierarchy. Combined evidence distinguishes the fault before implementing: Distinguish access ports and their SAPs from the provider's network-facing transport ports.
D:This is a direct diagnostic for the reported fault: Inspect actual SR OS port mode and the service attachment hierarchy. A second independent check is: Compare the physical circuit role with the Nokia service deployment diagram. Combined evidence distinguishes the fault before implementing: Distinguish access ports and their SAPs from the provider's network-facing transport ports.
Incorrect Answers
A:This choice does not address the stated situation: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Its competing context is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The relevant diagnostic is: Inspect actual SR OS port mode and the service attachment hierarchy. The case-supported response is: Compare the physical circuit role with the Nokia service deployment diagram; and Inspect actual SR OS port mode and the service attachment hierarchy.
C:These other facts could justify the alternative: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. They differ from the stated case: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Test the distinction using: Inspect actual SR OS port mode and the service attachment hierarchy. The case-specific response is: Compare the physical circuit role with the Nokia service deployment diagram; and Inspect actual SR OS port mode and the service attachment hierarchy.
E:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The pertinent verification is: Inspect actual SR OS port mode and the service attachment hierarchy. The action or outcome to select here is: Compare the physical circuit role with the Nokia service deployment diagram; and Inspect actual SR OS port mode and the service attachment hierarchy.
Question 608
An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. If the condition is left unresolved, which operational consequence is most directly at risk?
- A green transport or SDP check cannot establish application reachability through customer filters.
- A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
- Using the wrong port role can block service creation or expose customer payloads to transport interfaces.
- A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
Explanation
Correct Answer
C:The observed condition is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The principal operational or security impact is: Using the wrong port role can block service creation or expose customer payloads to transport interfaces. The supported repair is: Distinguish access ports and their SAPs from the provider's network-facing transport ports. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The distinguishing check is: Inspect actual SR OS port mode and the service attachment hierarchy. The supported action or criterion is: Using the wrong port role can block service creation or expose customer payloads to transport interfaces.
B:These other facts could justify the alternative: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. They differ from the stated case: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Test the distinction using: Inspect actual SR OS port mode and the service attachment hierarchy. The case-specific response is: Using the wrong port role can block service creation or expose customer payloads to transport interfaces.
D:The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The pertinent verification is: Inspect actual SR OS port mode and the service attachment hierarchy. The action or outcome to select here is: Using the wrong port role can block service creation or expose customer payloads to transport interfaces.
Question 609
An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)
- Distinguish access ports and their SAPs from the provider's network-facing transport ports.
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
- Confirm maintenance approval and port purpose before attempting any mode conversion.
- Verify MTU at both customer attachment endpoints and the transport service overhead.
- Restore the intended service administrative state after confirming maintenance authorization.
Explanation
Correct Answers
A:This is the required technical repair: Distinguish access ports and their SAPs from the provider's network-facing transport ports. The separately necessary deployment safeguard is: Confirm maintenance approval and port purpose before attempting any mode conversion. Together they address: Using the wrong port role can block service creation or expose customer payloads to transport interfaces.
C:This safeguard prevents unwanted collateral effects: Confirm maintenance approval and port purpose before attempting any mode conversion. Its complementary corrective change is: Distinguish access ports and their SAPs from the provider's network-facing transport ports. Both are required because: Using the wrong port role can block service creation or expose customer payloads to transport interfaces.
Incorrect Answers
B:The actual case evidence is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Inspect actual SR OS port mode and the service attachment hierarchy. The response supported by the evidence is: Distinguish access ports and their SAPs from the provider's network-facing transport ports; and Confirm maintenance approval and port purpose before attempting any mode conversion.
D:This choice does not address the stated situation: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Its competing context is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The relevant diagnostic is: Inspect actual SR OS port mode and the service attachment hierarchy. The case-supported response is: Distinguish access ports and their SAPs from the provider's network-facing transport ports; and Confirm maintenance approval and port purpose before attempting any mode conversion.
E:The alternative applies to another situation: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The reported case instead states: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The distinguishing check is: Inspect actual SR OS port mode and the service attachment hierarchy. The supported action or criterion is: Distinguish access ports and their SAPs from the provider's network-facing transport ports; and Confirm maintenance approval and port purpose before attempting any mode conversion.
Question 610
An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Which measurable result would verify success without relying on assumptions?
- The contracted customer application passes while unapproved access remains blocked.
- Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
- The remote attachment comes Up and the Epipe reports end-to-end operational service.
- The customer SAP attaches to the correct access port while core transport remains isolated.
Explanation
Correct Answer
D:The acceptance measurement for this case is: The customer SAP attaches to the correct access port while core transport remains isolated. It establishes that the intended remediation (“Distinguish access ports and their SAPs from the provider's network-facing transport ports”) was effective and can be corroborated by: Compare the physical circuit role with the Nokia service deployment diagram.
Incorrect Answers
A:The actual case evidence is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Inspect actual SR OS port mode and the service attachment hierarchy. The response supported by the evidence is: The customer SAP attaches to the correct access port while core transport remains isolated.
B:The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The pertinent verification is: Inspect actual SR OS port mode and the service attachment hierarchy. The action or outcome to select here is: The customer SAP attaches to the correct access port while core transport remains isolated.
C:This choice does not address the stated situation: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect actual SR OS port mode and the service attachment hierarchy. The case-supported response is: The customer SAP attaches to the correct access port while core transport remains isolated.