cert
cert-1
cert-2

Pass Nokia 4A0-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
4A0-C03 Exam - Verified By Experts
4A0-C03 Premium File

4A0-C03 Premium File

$69.99
$76.99
  • Premium File 145 Questions & Answers. Last Update: Nov 23, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Nokia 4A0-C03 Practice Test 15

Question 140

An IS-IS route disappears because bound BFD detects a downstream path failure even though the fiber interface still shows carrier. After the approved repair, which outcome best demonstrates that this exact fault is resolved?

  1. The chosen next hop is correctly explained by route origin and applicable metrics.
  2. The router uses the approved route source and unrelated IS-IS metrics remain unchanged.
  3. The repaired data path passes controlled traffic and the BFD-backed IS-IS adjacency stabilizes.
  4. Overload clears only when ready and approved transit paths use the router without loss.

Explanation

Correct Answer

C:

The acceptance measurement for this case is: The repaired data path passes controlled traffic and the BFD-backed IS-IS adjacency stabilizes. It establishes that the intended remediation (“Investigate end-to-end forwarding and BFD state rather than treating optical link-up as proof of health”) was effective and can be corroborated by: Compare packet delivery and optic counters during the same failure interval.

Incorrect Answers

A:

The actual case evidence is: An IS-IS route disappears because bound BFD detects a downstream path failure even though the fiber interface still shows carrier. The proposed option addresses a different condition: A redistributed external service prefix carries a larger route metric than expected, and an operator compares it directly to an internal path without checking route type. Confirm the distinction by checking: Inspect BFD session state and negotiated discriminators on the affected IS-IS adjacency. The response supported by the evidence is: The repaired data path passes controlled traffic and the BFD-backed IS-IS adjacency stabilizes.

B:

The alternative is directed at this separate case: A Nokia route table installs an outdated preferred static prefix instead of a valid IS-IS path, but a technician keeps lowering IS-IS costs expecting a change. The present incident is: An IS-IS route disappears because bound BFD detects a downstream path failure even though the fiber interface still shows carrier. The pertinent verification is: Inspect BFD session state and negotiated discriminators on the affected IS-IS adjacency. The action or outcome to select here is: The repaired data path passes controlled traffic and the BFD-backed IS-IS adjacency stabilizes.

D:

The alternative applies to another situation: A newly restarted core router advertises IS-IS overload while stabilizing, and nearby nodes avoid choosing it for transit even though its management loopback responds. The reported case instead states: An IS-IS route disappears because bound BFD detects a downstream path failure even though the fiber interface still shows carrier. The distinguishing check is: Inspect BFD session state and negotiated discriminators on the affected IS-IS adjacency. The supported action or criterion is: The repaired data path passes controlled traffic and the BFD-backed IS-IS adjacency stabilizes.

Question 141

A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. An operator needs a controlled repair. Which response is most appropriate?

  1. Inspect IS-IS route resolution and restore the correct IPv6 forwarding adjacency on the intended local link.
  2. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  3. Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.
  4. Correct the authorized tag or narrow policy match for the intended external prefix only.

Explanation

Correct Answer

C:

The fault stated in this case is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The specific corrective action is: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause. Confirm it with: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The expected end-to-end outcome is: The neighbor remains stable under representative load and real path failures still trigger detection.

Incorrect Answers

A:

The alternative is directed at this separate case: An IS-IS router advertises IPv6 prefixes correctly but the receiving edge lacks the proper IPv6 next-hop interface association for one connected circuit. The present incident is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The pertinent verification is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The action or outcome to select here is: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

B:

This choice does not address the stated situation: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Its competing context is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The relevant diagnostic is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The case-supported response is: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

D:

These other facts could justify the alternative: A redistributed static network is present in a border router's RIB but missing from IS-IS because its route tag differs from the policy's accepted tag. They differ from the stated case: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Test the distinction using: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The case-specific response is: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

Question 142

A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)

  1. Inspect route tags on the static source and the relevant IS-IS redistribution filter.
  2. Review BFD transmit, receive and multiplier negotiation alongside session reset logs.
  3. Correlate session loss with control CPU scheduling and packet loss across the circuit.
  4. Compare learned IPv6 reachability advertisements with actual forwarding entries.
  5. Inspect external reachability attributes and source redistribution policy.

Explanation

Correct Answers

B:

This is a direct diagnostic for the reported fault: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. A second independent check is: Correlate session loss with control CPU scheduling and packet loss across the circuit. Combined evidence distinguishes the fault before implementing: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

C:

This is a direct diagnostic for the reported fault: Correlate session loss with control CPU scheduling and packet loss across the circuit. A second independent check is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. Combined evidence distinguishes the fault before implementing: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

Incorrect Answers

A:

This choice does not address the stated situation: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Its competing context is: A redistributed static network is present in a border router's RIB but missing from IS-IS because its route tag differs from the policy's accepted tag. The relevant diagnostic is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The case-supported response is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs; and Correlate session loss with control CPU scheduling and packet loss across the circuit.

D:

The actual case evidence is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The proposed option addresses a different condition: An IS-IS router advertises IPv6 prefixes correctly but the receiving edge lacks the proper IPv6 next-hop interface association for one connected circuit. Confirm the distinction by checking: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The response supported by the evidence is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs; and Correlate session loss with control CPU scheduling and packet loss across the circuit.

E:

The alternative is directed at this separate case: A redistributed external service prefix carries a larger route metric than expected, and an operator compares it directly to an internal path without checking route type. The present incident is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The pertinent verification is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The action or outcome to select here is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs; and Correlate session loss with control CPU scheduling and packet loss across the circuit.

Question 143

A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Which specific consequence explains why a repair is necessary?

  1. A received IPv6 prefix can exist in the database without a usable local next hop.
  2. A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
  3. Overaggressive fault detection can destabilize routing even without a permanent transport outage.
  4. Overbroad tag adjustments can unintentionally export sensitive external routes into the core.

Explanation

Correct Answer

C:

The observed condition is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The principal operational or security impact is: Overaggressive fault detection can destabilize routing even without a permanent transport outage. The supported repair is: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: An IS-IS router advertises IPv6 prefixes correctly but the receiving edge lacks the proper IPv6 next-hop interface association for one connected circuit. The reported case instead states: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The distinguishing check is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The supported action or criterion is: Overaggressive fault detection can destabilize routing even without a permanent transport outage.

B:

These other facts could justify the alternative: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. They differ from the stated case: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Test the distinction using: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The case-specific response is: Overaggressive fault detection can destabilize routing even without a permanent transport outage.

D:

The alternative is directed at this separate case: A redistributed static network is present in a border router's RIB but missing from IS-IS because its route tag differs from the policy's accepted tag. The present incident is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The pertinent verification is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The action or outcome to select here is: Overaggressive fault detection can destabilize routing even without a permanent transport outage.

Question 144

A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)

  1. Test adjusted timers on one monitored adjacency before widening the change.
  2. Inspect IS-IS route resolution and restore the correct IPv6 forwarding adjacency on the intended local link.
  3. Constrain IS-IS redistribution to the exact approved customer prefix and withdraw the oversized route.
  4. Review external prefix origin and applicable IS-IS route selection before changing the path cost.
  5. Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

Explanation

Correct Answers

A:

This safeguard prevents unwanted collateral effects: Test adjusted timers on one monitored adjacency before widening the change. Its complementary corrective change is: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause. Both are required because: Overaggressive fault detection can destabilize routing even without a permanent transport outage.

E:

This is the required technical repair: Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause. The separately necessary deployment safeguard is: Test adjusted timers on one monitored adjacency before widening the change. Together they address: Overaggressive fault detection can destabilize routing even without a permanent transport outage.

Incorrect Answers

B:

The actual case evidence is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The proposed option addresses a different condition: An IS-IS router advertises IPv6 prefixes correctly but the receiving edge lacks the proper IPv6 next-hop interface association for one connected circuit. Confirm the distinction by checking: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The response supported by the evidence is: Test adjusted timers on one monitored adjacency before widening the change; and Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

C:

The alternative is directed at this separate case: A temporary redistribution policy inadvertently announces a broad synthetic customer summary into the core rather than its single authorized subnet. The present incident is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The pertinent verification is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The action or outcome to select here is: Test adjusted timers on one monitored adjacency before widening the change; and Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

D:

This choice does not address the stated situation: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Its competing context is: A redistributed external service prefix carries a larger route metric than expected, and an operator compares it directly to an internal path without checking route type. The relevant diagnostic is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The case-supported response is: Test adjusted timers on one monitored adjacency before widening the change; and Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause.

Question 145

A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Which post-change observation is the strongest acceptance criterion?

  1. The neighbor remains stable under representative load and real path failures still trigger detection.
  2. Only the intended external route enters the IS-IS domain and other tags remain blocked.
  3. IPv6 traffic follows the approved circuit and all intended destinations remain reachable.
  4. The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

Explanation

Correct Answer

A:

The acceptance measurement for this case is: The neighbor remains stable under representative load and real path failures still trigger detection. It establishes that the intended remediation (“Select peer-compatible detection timing with demonstrated platform performance and correct the overload cause”) was effective and can be corroborated by: Correlate session loss with control CPU scheduling and packet loss across the circuit.

Incorrect Answers

B:

The alternative is directed at this separate case: A redistributed static network is present in a border router's RIB but missing from IS-IS because its route tag differs from the policy's accepted tag. The present incident is: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The pertinent verification is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The action or outcome to select here is: The neighbor remains stable under representative load and real path failures still trigger detection.

C:

This choice does not address the stated situation: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. Its competing context is: An IS-IS router advertises IPv6 prefixes correctly but the receiving edge lacks the proper IPv6 next-hop interface association for one connected circuit. The relevant diagnostic is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The case-supported response is: The neighbor remains stable under representative load and real path failures still trigger detection.

D:

The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: A busy edge router intermittently declares an IS-IS neighbor dead because its BFD detection interval is shorter than the platform's supported scheduling behavior. The distinguishing check is: Review BFD transmit, receive and multiplier negotiation alongside session reset logs. The supported action or criterion is: The neighbor remains stable under representative load and real path failures still trigger detection.

Question 146

An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Which next technical step should the engineer prioritize?

  1. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  2. Allow normal PSNP-based missing-LSP acknowledgment or request processing to repair database synchronization.
  3. Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure.
  4. Review external prefix origin and applicable IS-IS route selection before changing the path cost.

Explanation

Correct Answer

C:

The fault stated in this case is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The specific corrective action is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure. Confirm it with: Inspect primary and backup shortest path distances for the neighbor and destination. The expected end-to-end outcome is: Traffic takes a proven loop-free alternate immediately after the protected failure.

Incorrect Answers

A:

The alternative is directed at this separate case: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The present incident is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The pertinent verification is: Inspect primary and backup shortest path distances for the neighbor and destination. The action or outcome to select here is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure.

B:

This choice does not address the stated situation: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Its competing context is: A router joins a newly restored point-to-point link and requests a missing LSP using PSNP, but the operator expects a full database reset. The relevant diagnostic is: Inspect primary and backup shortest path distances for the neighbor and destination. The case-supported response is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure.

D:

These other facts could justify the alternative: A redistributed external service prefix carries a larger route metric than expected, and an operator compares it directly to an internal path without checking route type. They differ from the stated case: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Test the distinction using: Inspect primary and backup shortest path distances for the neighbor and destination. The case-specific response is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure.

Question 147

An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Which TWO items of evidence should the engineer examine first? (Select TWO.)

  1. Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange.
  2. Inspect primary and backup shortest path distances for the neighbor and destination.
  3. Inspect per-prefix alternate next-hop entries and their protection reasons.
  4. Simulate the protected link failure and trace the proposed alternate's return path.
  5. Inspect the PSNP identifier list and the neighbor's advertised LSP sequence values.

Explanation

Correct Answers

B:

This is a direct diagnostic for the reported fault: Inspect primary and backup shortest path distances for the neighbor and destination. A second independent check is: Simulate the protected link failure and trace the proposed alternate's return path. Combined evidence distinguishes the fault before implementing: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure.

D:

This is a direct diagnostic for the reported fault: Simulate the protected link failure and trace the proposed alternate's return path. A second independent check is: Inspect primary and backup shortest path distances for the neighbor and destination. Combined evidence distinguishes the fault before implementing: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure.

Incorrect Answers

A:

This choice does not address the stated situation: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Its competing context is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The relevant diagnostic is: Inspect primary and backup shortest path distances for the neighbor and destination. The case-supported response is: Inspect primary and backup shortest path distances for the neighbor and destination; and Simulate the protected link failure and trace the proposed alternate's return path.

C:

These other facts could justify the alternative: An IS-IS router reports fast reroute for local loopbacks, but a remote customer prefix has no feasible LFA and is incorrectly included in an all-protected claim. They differ from the stated case: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Test the distinction using: Inspect primary and backup shortest path distances for the neighbor and destination. The case-specific response is: Inspect primary and backup shortest path distances for the neighbor and destination; and Simulate the protected link failure and trace the proposed alternate's return path.

E:

The alternative is directed at this separate case: A router joins a newly restored point-to-point link and requests a missing LSP using PSNP, but the operator expects a full database reset. The present incident is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The pertinent verification is: Inspect primary and backup shortest path distances for the neighbor and destination. The action or outcome to select here is: Inspect primary and backup shortest path distances for the neighbor and destination; and Simulate the protected link failure and trace the proposed alternate's return path.

Question 148

An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. If the condition is left unresolved, which operational consequence is most directly at risk?

  1. A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
  2. Comparing dissimilar route types by raw metric can lead to ineffective network changes.
  3. A non-loop-free alternate may redirect packets back to the failed link and prolong outages.
  4. Ignoring partial database synchronization can prolong stale routes or prompt unnecessary disruptive resets.

Explanation

Correct Answer

C:

The observed condition is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The principal operational or security impact is: A non-loop-free alternate may redirect packets back to the failed link and prolong outages. The supported repair is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The distinguishing check is: Inspect primary and backup shortest path distances for the neighbor and destination. The supported action or criterion is: A non-loop-free alternate may redirect packets back to the failed link and prolong outages.

B:

These other facts could justify the alternative: A redistributed external service prefix carries a larger route metric than expected, and an operator compares it directly to an internal path without checking route type. They differ from the stated case: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Test the distinction using: Inspect primary and backup shortest path distances for the neighbor and destination. The case-specific response is: A non-loop-free alternate may redirect packets back to the failed link and prolong outages.

D:

The alternative is directed at this separate case: A router joins a newly restored point-to-point link and requests a missing LSP using PSNP, but the operator expects a full database reset. The present incident is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The pertinent verification is: Inspect primary and backup shortest path distances for the neighbor and destination. The action or outcome to select here is: A non-loop-free alternate may redirect packets back to the failed link and prolong outages.

Question 149

An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)

  1. Diagnose the point-to-point adjacency handshake and correct mismatched peer state before resetting the entire area.
  2. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  3. Measure backup-path availability for each intended destination rather than generalizing from a subset.
  4. Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure.
  5. Enable protection only for prefixes whose backup meets verified loop-free criteria.

Explanation

Correct Answers

D:

This is the required technical repair: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure. The separately necessary deployment safeguard is: Enable protection only for prefixes whose backup meets verified loop-free criteria. Together they address: A non-loop-free alternate may redirect packets back to the failed link and prolong outages.

E:

This safeguard prevents unwanted collateral effects: Enable protection only for prefixes whose backup meets verified loop-free criteria. Its complementary corrective change is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure. Both are required because: A non-loop-free alternate may redirect packets back to the failed link and prolong outages.

Incorrect Answers

A:

These other facts could justify the alternative: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. They differ from the stated case: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Test the distinction using: Inspect primary and backup shortest path distances for the neighbor and destination. The case-specific response is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure; and Enable protection only for prefixes whose backup meets verified loop-free criteria.

B:

The actual case evidence is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The proposed option addresses a different condition: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Confirm the distinction by checking: Inspect primary and backup shortest path distances for the neighbor and destination. The response supported by the evidence is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure; and Enable protection only for prefixes whose backup meets verified loop-free criteria.

C:

The alternative is directed at this separate case: An IS-IS router reports fast reroute for local loopbacks, but a remote customer prefix has no feasible LFA and is incorrectly included in an all-protected claim. The present incident is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The pertinent verification is: Inspect primary and backup shortest path distances for the neighbor and destination. The action or outcome to select here is: Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure; and Enable protection only for prefixes whose backup meets verified loop-free criteria.

Question 150

An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Which measurable result would verify success without relying on assumptions?

  1. Traffic takes a proven loop-free alternate immediately after the protected failure.
  2. The chosen next hop is correctly explained by route origin and applicable metrics.
  3. The requested LSP arrives and both neighbors agree on the current database without area-wide resets.
  4. The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

Explanation

Correct Answer

A:

The acceptance measurement for this case is: Traffic takes a proven loop-free alternate immediately after the protected failure. It establishes that the intended remediation (“Calculate the applicable loop-free inequality and reject alternates that recurse through the protected failure”) was effective and can be corroborated by: Simulate the protected link failure and trace the proposed alternate's return path.

Incorrect Answers

B:

The alternative is directed at this separate case: A redistributed external service prefix carries a larger route metric than expected, and an operator compares it directly to an internal path without checking route type. The present incident is: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The pertinent verification is: Inspect primary and backup shortest path distances for the neighbor and destination. The action or outcome to select here is: Traffic takes a proven loop-free alternate immediately after the protected failure.

C:

This choice does not address the stated situation: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. Its competing context is: A router joins a newly restored point-to-point link and requests a missing LSP using PSNP, but the operator expects a full database reset. The relevant diagnostic is: Inspect primary and backup shortest path distances for the neighbor and destination. The case-supported response is: Traffic takes a proven loop-free alternate immediately after the protected failure.

D:

The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: An operator labels the nearest backup next hop as loop free without checking whether that neighbor's path to the destination uses the protected failed link. The distinguishing check is: Inspect primary and backup shortest path distances for the neighbor and destination. The supported action or criterion is: Traffic takes a proven loop-free alternate immediately after the protected failure.

Nokia NRS II Composite: IS-IS version (4A0-C03) Practice Tests