Question 610
A minor interface renumbering inadvertently disconnects an emergency paging VLAN that was omitted from impact review. Which switching implementation or corrective action BEST addresses the underlying requirement?
Explanation
Correct Answer
Maintain approved maintenance records, affected path inventory, user notices and postchange validation for recurring wired network work. This addresses the controlling network requirement rather than merely changing its symptoms. Maintenance success depends on operational coordination as well as command execution and hardware status. Verify before and after with: Check change owner, impact window, outage dependencies, test plan, rollback threshold and service notification record. Scenario: A minor interface renumbering inadvertently disconnects an emergency paging VLAN that was omitted from impact review.
Incorrect Answers
Attribute application loss to the actual congested egress queue and traffic class rather than only interface-level packet drops. This action instead applies to QoS queue drop root cause under congestion. Interface error counters can remain zero while egress queues discard packets during oversubscription. It does not directly resolve the controlling requirement. The targeted response is: Maintain approved maintenance records, affected path inventory, user notices and postchange validation for recurring wired network work. Scenario: A minor interface renumbering inadvertently disconnects an emergency paging VLAN that was omitted from impact review.
Use LLDP neighbor data and interface inventories to verify connected peers and document the physical campus topology. This action instead applies to LLDP topology and neighbor mapping. LLDP is discovery evidence but neighbor advertisements do not prove the entire end-to-end forwarding path is authorized. It does not directly resolve the controlling requirement. The targeted response is: Maintain approved maintenance records, affected path inventory, user notices and postchange validation for recurring wired network work. Scenario: A minor interface renumbering inadvertently disconnects an emergency paging VLAN that was omitted from impact review.
Use scheduled and validated AOS-CX software maintenance with platform-specific images, checkpoints and supported fallback approach. This action instead applies to Firmware maintenance compatibility and image fallback. Software maintenance must verify active image and network behavior rather than stop at successful upload of a file. It does not directly resolve the controlling requirement. The targeted response is: Maintain approved maintenance records, affected path inventory, user notices and postchange validation for recurring wired network work. Scenario: A minor interface renumbering inadvertently disconnects an emergency paging VLAN that was omitted from impact review.