HP HPE6-A86 Practice Test 14
Question 130
Which evidence should be examined FIRST to localize this switch-related fault? A VLAN interface serving end-user PCs emits OSPF hellos unnecessarily although no router is expected on that network.
- Inspect OSPF interface settings, neighbor table, route LSA and captured hello packets.
- Inspect show ip interface brief, SVI state, routing table and client ARP.
- Check show lldp neighbor-info detail, interface descriptions and cable inventory.
- Inspect show version, boot image selection, startup configuration and boot event log.
Explanation
Correct Answer
A:Inspect OSPF interface settings, neighbor table, route LSA and captured hello packets. Passive interfaces suppress OSPF neighbor formation on selected networks while route advertisement can remain configured. Next step: Set the appropriate supported passive OSPF interface design while retaining desired network advertisement.
Incorrect Answers
B:This diagnostic addresses another network condition (An engineer creates VLAN70 on a Layer 3 AOS-CX switch but puts the gateway address on the wrong VLAN SVI.). Here inspect: Inspect OSPF interface settings, neighbor table, route LSA and captured hello packets.
C:Check show lldp neighbor-info detail, interface descriptions and cable inventory. This diagnostic addresses another network condition (After rewiring a campus distribution panel, staff see conflicting port-label records for one access uplink.). Here inspect: Inspect OSPF interface settings, neighbor table, route LSA and captured hello packets.
D:This diagnostic addresses another network condition (After first boot, a switch unexpectedly starts an old image despite a staged upgrade and the engineer proceeds without checking active software.). Here inspect: Inspect OSPF interface settings, neighbor table, route LSA and captured hello packets.
Question 131
Which measurable state would demonstrate the fault was resolved? A campus closet's uplink documentation lists switch B on port 1/1/48 while cables were moved to port 1/1/47.
- Both physical members contribute to one loop-free LAG without an unintended standalone blocked link.
- The authorized remote management network reaches the OOBM address and data VLAN routes remain unchanged.
- The replacement has the correct member identity and all intended stack links report healthy state.
- The observed neighbor and port map matches the corrected topology record.
Explanation
Correct Answer
D:The observed neighbor and port map matches the corrected topology record. Corresponding action: Use LLDP neighbor detail and interface counters to verify the active connected peer and port.
Incorrect Answers
A:That observation verifies a different fault (Two parallel uplinks intended as one LAG are actually configured as independent trunks, causing RSTP to block one.). Both physical members contribute to one loop-free LAG without an unintended standalone blocked link.
B:That observation verifies a different fault (An AOS-CX switch management port has a valid IPv4 address, but off-subnet operations workstations cannot access it.). For the question at hand, verify: The observed neighbor and port map matches the corrected topology record.
C:That observation verifies a different fault (A newly replaced VSF member forwards locally but is not recognized as a healthy member of the intended stack.). For the question at hand, verify: The observed neighbor and port map matches the corrected topology record.
Question 132
Which technical networking principle BEST explains this condition? A branch places forty access switches directly on a perimeter firewall with no suitable uplink distribution and experiences oversubscribed forwarding.
- Distribution switching aggregates access paths and can supply routing or policy features depending on the selected platform.
- Ethernet port speed options vary across product families and cannot be created by changing VLANs.
- Hardware family names are not sufficient evidence of current availability, software support or licensing entitlement.
- PoE redundancy under power supply failure depends on actual reserved capacity and switch policy.
Explanation
Correct Answer
A:Distribution switching aggregates access paths and can supply routing or policy features depending on the selected platform. Appropriate intervention: Choose an appropriately capable aggregation/distribution switching layer and sized routed or Layer 2 links.
Incorrect Answers
B:This concept applies to another switch problem (A high-density access site requires 2.5-Gb/s access for Wi-Fi uplinks but selects a platform whose edge ports are gigabit-only.). Distribution switching aggregates access paths and can supply routing or policy features depending on the selected platform.
C:This concept applies to another switch problem (A network manager orders a discontinued switch variant after seeing its family name on an old training slide without checking current support.). Distribution switching aggregates access paths and can supply routing or policy features depending on the selected platform.
D:This concept applies to another switch problem (A school runs critical badge readers from a PoE switch with dual power supplies but disables power redundancy allocation.). Distribution switching aggregates access paths and can supply routing or policy features depending on the selected platform.
Question 133
A wired network administrator encounters: An engineer proposes VSX multi-chassis aggregation steps on two fixed access members designed for a VSF stack. Which configuration or response is MOST appropriate?
- Validate supported web or CLI management services for the exact AOS-CX model and provision approved addresses and access.
- Evaluate modular switching platforms with documented redundancy and line-card expansion as required by the core design.
- Size uplink ports and an appropriate access/aggregation switch family based on expected concurrent service traffic.
- Select the topology and features supported by the exact platforms, distinguishing VSF stacking from VSX peer redundancy.
Explanation
Correct Answer
D:Select the topology and features supported by the exact platforms, distinguishing VSF stacking from VSX peer redundancy. VSF and VSX are different HPE Aruba Networking multi-switch architectures with platform-dependent support. Verified result: The resulting design uses the supported interconnect and management semantics for that model family.
Incorrect Answers
A:This change serves a different network condition (A field operator assumes every Aruba switch ships with the same always-enabled in-band web GUI and no setup is needed.), not the issue described. Appropriate response here: Select the topology and features supported by the exact platforms, distinguishing VSF stacking from VSX peer redundancy.
B:This change serves a different network condition (A regional core requires numerous line cards and high-density redundant power, but a fixed 24-port access model is proposed.), not the issue described. Appropriate response here: Select the topology and features supported by the exact platforms, distinguishing VSF stacking from VSX peer redundancy.
C:This change serves a different network condition (A remote closet has forty gigabit users and a 1-Gb/s uplink saturated by backups, yet planners buy more client ports without changing aggregation.), not the issue described. Appropriate response here: Select the topology and features supported by the exact platforms, distinguishing VSF stacking from VSX peer redundancy.
Question 134
For this wired switching issue, which investigation and response plan is MOST defensible? A virtualization host tags its guest networks but the switchport is configured as a single untagged access port.
- First, Compare server vSwitch port groups, Ethernet tags and AOS-CX trunk allowed/native configuration. Then, Configure an approved trunk and corresponding server VLAN tag interfaces while retaining a planned native management VLAN.
- First, Inspect spanning-tree mode, role transitions, topology changes and recovery timing during an uplink loss. Then, Review RSTP operation, bridge priorities, port roles and edge link classification.
- First, Inspect host mask, routing table, ARP traffic and first-hop packet capture. Then, Correct the client's subnet mask and default gateway so remote targets use router next-hop resolution.
- First, Inspect per-port PoE classification, reserved draw, available budget and load-event logs. Then, Calculate total power demand and allocate or upgrade supported power capacity for priority ports.
Explanation
Correct Answer
A:A hypervisor trunk requires consistent VLAN tagging expectations on the virtual and physical switch boundaries.
Incorrect Answers
B:This plan investigates a different issue (A distribution uplink fails and traffic takes an excessive time to recover even though alternate Ethernet links exist.).
C:This plan investigates a different issue (A client ARPs for the final destination on another IPv4 subnet after a technician sets an incorrect on-link mask.). For the case described, inspect: Compare server vSwitch port groups, Ethernet tags and AOS-CX trunk allowed/native configuration.
D:This plan investigates a different issue (A stack of badge readers reboots during shift change after the access switch exhausts its available PoE budget.).
Question 135
Which measurable state would demonstrate the fault was resolved? A telemetry application repeatedly polls hundreds of AOS-CX switches and begins receiving API throttling and intermittent errors.
- The management system collects complete data within rate limits and surfaces unresolved collection gaps.
- The device boots a supported image and existing network services pass post-upgrade tests.
- Branches receive the intended standard and special sites preserve documented exceptions.
- Read-only status inspection works, unauthorized writes fail and approved change records identify the operator.
Explanation
Correct Answer
A:The management system collects complete data within rate limits and surfaces unresolved collection gaps. Corresponding action: Implement bounded concurrent requests, retry/backoff, cached inventory and fault visibility appropriate to the API.
Incorrect Answers
B:That observation verifies a different fault (A branch technician copies a new firmware image built for one Aruba switch family onto an unrelated model.). For the question at hand, verify: The management system collects complete data within rate limits and surfaces unresolved collection gaps.
C:That observation verifies a different fault (A set of branch switches joins cloud management but receives an inappropriate template due to assignment to the wrong device group.). For the question at hand, verify: The management system collects complete data within rate limits and surfaces unresolved collection gaps.
D:That observation verifies a different fault (A support contractor can view port status through a CLI role but is denied configuration writes, and an administrator assumes the switch is faulty.). Read-only status inspection works, unauthorized writes fail and approved change records identify the operator.
Question 136
Which proposed action would be LEAST defensible for this AOS-CX or network problem? A campus core requires a long fiber run but procurement supplies copper-only switch modules with no usable optical interface.
- Verify the correct device and port before changing production configuration.
- Correlate link fault counters with time and live traffic.
- Restrict monitoring permissions to the required data access.
- Attach fiber directly to a copper-only RJ-45 socket using an unsupported passive adapter.
Explanation
Correct Answer
D:Attach fiber directly to a copper-only RJ-45 socket using an unsupported passive adapter. Physical media and supported transceiver choices are constraints of the selected switch hardware. Safer action: Select a hardware model and transceiver port combination with the required supported optical reach.
Incorrect Answers
A:Verify the correct device and port before changing production configuration. Accurate change scoping prevents unintended service disruption. For the stated issue, the appropriate action is: Select a hardware model and transceiver port combination with the required supported optical reach.
B:Correlate link fault counters with time and live traffic. Cumulative counters must be interpreted against a baseline. For the stated issue, the appropriate action is: Select a hardware model and transceiver port combination with the required supported optical reach.
C:Restrict monitoring permissions to the required data access. Read-only telemetry rarely needs broad configuration privileges. For the stated issue, the appropriate action is: Select a hardware model and transceiver port combination with the required supported optical reach.
Question 137
What fundamental switching or routing concept is MOST relevant here? A monitoring deployment reuses one SNMPv2 community across all switches while compliance requires authenticated confidential device telemetry.
- SNMPv3 can provide authentication and privacy for management telemetry, improving over v2c community-only access.
- Physical access to networking gear can bypass parts of management and port-security assumptions.
- Average utilization can conceal periodic congestion that causes user-visible packet drops.
- Accurate synchronized timestamps enable troubleshooting and reliable change or security auditing.
Explanation
Correct Answer
A:SNMPv3 can provide authentication and privacy for management telemetry, improving over v2c community-only access. Appropriate intervention: Provision supported SNMPv3 users with scoped authentication/privacy and protected secret distribution.
Incorrect Answers
B:This concept applies to another switch problem (A branch's switching rack is accessible from a public hallway, with live management console ports and unused front-panel ports.). SNMPv3 can provide authentication and privacy for management telemetry, improving over v2c community-only access.
C:This concept applies to another switch problem (A branch repeatedly saturates its uplink at the end of each month, but reports show only average daily utilization.). SNMPv3 can provide authentication and privacy for management telemetry, improving over v2c community-only access.
D:This concept applies to another switch problem (Cross-switch port events cannot be ordered because the distribution switch runs UTC and access devices have uncontrolled clocks.). SNMPv3 can provide authentication and privacy for management telemetry, improving over v2c community-only access.
Question 138
An HPE Aruba Networking switch operator observes this condition: Two ports intended for a LAG operate at different negotiated speeds after an optic replacement and aggregation health degrades. What action BEST addresses the fault?
- Review bandwidth, classification, trust and queue policies, then enforce appropriate congestion treatment.
- Replace or reconfigure media to meet supported member compatibility before restoring redundancy.
- Reorder or refine the supported ACL in approved policy precedence and test allowed plus denied paths.
- Progress to physical and next-hop ARP checks rather than treat a local loopback reply as network reachability.
Explanation
Correct Answer
B:Replace or reconfigure media to meet supported member compatibility before restoring redundancy. Aggregation may exclude members whose link capabilities are not compatible with the logical bundle. Verified result: Both LAG members negotiate compatible speeds and carry expected aggregate traffic.
Incorrect Answers
A:This change serves a different network condition (Voice calls degrade during large backups, and the switch shows voice queue drops even though all VLANs are correctly carried.), not the issue described. Appropriate response here: Replace or reconfigure media to meet supported member compatibility before restoring redundancy.
C:This change serves a different network condition (A permit rule was added for a management application but a broader deny rule above it continues to drop traffic.), not the issue described. Appropriate response here: Replace or reconfigure media to meet supported member compatibility before restoring redundancy.
D:This change serves a different network condition (A newly provisioned switch can ping its own loopback IP but not the default gateway, yet an operator calls the uplink healthy.), not the issue described. Appropriate response here: Replace or reconfigure media to meet supported member compatibility before restoring redundancy.
Question 139
Select TWO statements: the correct intervention and its observed verification in this AOS-CX case. A NOC pages engineers every time an access port changes state even when users regularly unplug docking stations at closing time.
- Action: Set event classifications and thresholds that distinguish routine edge changes from material uplink or stack faults.
- Verification: New classroom endpoints have correct VLAN/power and the management records match actual ports.
- Verification: Critical infrastructure alarms reach responders while benign endpoint disconnects do not flood escalation queues.
- Action: Issue a supported least-privileged API identity and rotate or revoke the original overpowered credential.
- Unsafe shortcut: Disable all port monitoring because noncritical edge changes generate too many alerts.
Explanation
Correct Answers
A:Action: Set event classifications and thresholds that distinguish routine edge changes from material uplink or stack faults. Monitoring should be actionable and proportional to service impact, not just maximize event volume.
C:Verification: Critical infrastructure alarms reach responders while benign endpoint disconnects do not flood escalation queues. Monitoring should be actionable and proportional to service impact, not just maximize event volume.
Incorrect Answers
B:This is validation for another condition (A school repeatedly reassigns Ethernet ports after classroom renovations without updating switchport descriptions or access policy ownership.). Here verify: Critical infrastructure alarms reach responders while benign endpoint disconnects do not flood escalation queues.
D:This remedy fits a different fault (An internal monitoring application holds a full-config-change REST API credential even though it collects only interface statistics.).
E:Monitoring should be actionable and proportional to service impact, not just maximize event volume.
Question 140
Which TWO claims link a supported response and validation for this wired switching scenario? A new routed department VLAN cannot obtain DHCP leases from the remote authorized server because its gateway does not relay broadcasts.
- Verification: Hosts receive the intended scope leases while rogue DHCP sources remain blocked.
- Unsafe shortcut: Move every department device into the server's management VLAN to avoid DHCP relay.
- Action: Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security.
- Verification: The preferred path appears in routing and traffic moves to backup on a controlled primary failure.
- Action: Update the interface description and asset/cable record while validating actual operational connection.
Explanation
Correct Answers
A:Verification: Hosts receive the intended scope leases while rogue DHCP sources remain blocked. DHCP discover broadcasts need an authorized relay across a routed boundary.
C:Action: Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security. DHCP discover broadcasts need an authorized relay across a routed boundary.
Incorrect Answers
B:This is not a supported or safe intervention in this scenario. DHCP discover broadcasts need an authorized relay across a routed boundary.
D:This is validation for another condition (Two redundant OSPF paths exist but traffic selects the slower backup because link costs were never reviewed.).
E:This remedy fits a different fault (A new uplink is physically patched into port 1/1/48 but the running configuration still describes it as a decommissioned printer.). For this case use: Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security.