HP HPE6-A86 Practice Test 106
Question 1050
A wired network administrator encounters: A daily network report shows zero faults because an SNMP collector stopped polling thirty switches after its credential expired. Which configuration or response is MOST appropriate?
- Apply physical access controls and enforce logical least-privilege interfaces and disable unused ports where appropriate.
- Establish approved time sources and validate clock offset across the fleet, preserving timezone display clarity.
- Mark collection gaps explicitly, restore collector authentication and assess missed critical events.
- Use peak and percentile traffic trends and queue drops to plan capacity or traffic prioritization.
Explanation
Correct Answer
C:Mark collection gaps explicitly, restore collector authentication and assess missed critical events. Observability depends on sensor/collector coverage and data freshness as well as event values. Verified result: The report distinguishes missing telemetry from measured zero-fault conditions with monitored poll coverage.
Incorrect Answers
A:This change serves a different network condition (A branch's switching rack is accessible from a public hallway, with live management console ports and unused front-panel ports.), not the issue described. Appropriate response here: Mark collection gaps explicitly, restore collector authentication and assess missed critical events.
B:This change serves a different network condition (Cross-switch port events cannot be ordered because the distribution switch runs UTC and access devices have uncontrolled clocks.), not the issue described. Appropriate response here: Mark collection gaps explicitly, restore collector authentication and assess missed critical events.
D:This change serves a different network condition (A branch repeatedly saturates its uplink at the end of each month, but reports show only average daily utilization.), not the issue described. Appropriate response here: Mark collection gaps explicitly, restore collector authentication and assess missed critical events.
Question 1051
Which diagnostic-then-correction sequence BEST addresses this network situation? A new AOS-CX switch has Layer 2 connectivity but never becomes visible in HPE Aruba Networking Central inventory.
- First, Compare traffic matrix, oversubscription ratio, interface capacities and queue drop rates. Then, Size uplink ports and an appropriate access/aggregation switch family based on expected concurrent service traffic.
- First, Check intake orientation, inlet temperature, fan status and facility airflow plan. Then, Use supported installation clearances, directional airflow and thermal monitoring for the hardware.
- First, Inspect certificate subject/SAN, issuer/trust, expiration and source ACL for the switch web UI. Then, Provision supported HTTPS certificate trust and access from the approved management segment.
- First, Inspect Central inventory/assignment, DNS/TLS reachability, management IP and onboarding logs. Then, Confirm account entitlement, device association, management routing and supported Central connectivity prerequisites.
Explanation
Correct Answer
D:Cloud management registration depends on device identity, network reachability and licensing or subscription workflow.
Incorrect Answers
A:This plan investigates a different issue (A remote closet has forty gigabit users and a 1-Gb/s uplink saturated by backups, yet planners buy more client ports without changing aggregation.). For the case described, inspect: Inspect Central inventory/assignment, DNS/TLS reachability, management IP and onboarding logs.
B:This plan investigates a different issue (A rack-mounted aggregation switch overheats after installation because intake airflow is blocked by front-mounted cable trays.). For the case described, inspect: Inspect Central inventory/assignment, DNS/TLS reachability, management IP and onboarding logs.
C:This plan investigates a different issue (A field team accepts any self-signed device management certificate without validating the hostname or administrator trust path.). For the case described, inspect: Inspect Central inventory/assignment, DNS/TLS reachability, management IP and onboarding logs.
Question 1052
What mistaken approach is MOST likely to worsen this networking fault? A new server-facing switchport remains administratively disabled after an approved cable move even though the transceiver is detected.
- Check a known-good rollback before a disruptive upgrade.
- Restrict monitoring permissions to the required data access.
- Choose switch hardware against traffic, PoE, and resiliency requirements.
- Enable every unused switchport in the closet to find the one connected to the server.
Explanation
Correct Answer
D:An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
Incorrect Answers
A:Check a known-good rollback before a disruptive upgrade. Controlled restoration reduces failed-change impact. For the stated issue, the appropriate action is: Enable only the intended interface and verify link and access policy before restoring server traffic.
B:Restrict monitoring permissions to the required data access. Read-only telemetry rarely needs broad configuration privileges. For the stated issue, the appropriate action is: Enable only the intended interface and verify link and access policy before restoring server traffic.
C:Choose switch hardware against traffic, PoE, and resiliency requirements. Product capabilities vary independently of procurement price. For the stated issue, the appropriate action is: Enable only the intended interface and verify link and access policy before restoring server traffic.
Question 1053
What fundamental switching or routing concept is MOST relevant here? A new branch route causes traceroute hops to alternate between two routers until TTL expires.
- Packet traces show what was transmitted and help distinguish VLAN tagging from IP configuration faults.
- A routing loop occurs when each router forwards a destination back toward another router without progress.
- Cumulative counters need timestamps and change rates to distinguish past faults from active problems.
- Structured troubleshooting narrows variables and avoids destructive changes that erase causal evidence.
Explanation
Correct Answer
B:A routing loop occurs when each router forwards a destination back toward another router without progress. Appropriate intervention: Inspect each router's selected next hop and correct the mutual static-route dependency or advertisement.
Incorrect Answers
A:This concept applies to another switch problem (Users report that a VoIP phone carries voice but its attached PC cannot join the data VLAN after a trunk policy update.). A routing loop occurs when each router forwards a destination back toward another router without progress.
C:This concept applies to another switch problem (A technician sees a large cumulative error counter and assumes a currently active fault despite no recent increment.). A routing loop occurs when each router forwards a destination back toward another router without progress.
D:This concept applies to another switch problem (An outage affects three access closets, but an operator schedules simultaneous resets of every device before gathering evidence.). A routing loop occurs when each router forwards a destination back toward another router without progress.
Question 1054
Identify the unsafe shortcut to REJECT for the following campus switching situation: A branch's switching rack is accessible from a public hallway, with live management console ports and unused front-panel ports.
- Check a known-good rollback before a disruptive upgrade.
- Assume a strong SSH password alone prevents misuse of an exposed local console and patch panel.
- Use SSH or secure management where supported and required.
- Keep recovery configuration files protected and versioned.
Explanation
Correct Answer
B:Safer action: Apply physical access controls and enforce logical least-privilege interfaces and disable unused ports where appropriate.
Incorrect Answers
A:Check a known-good rollback before a disruptive upgrade. Controlled restoration reduces failed-change impact. For the stated issue, the appropriate action is: Apply physical access controls and enforce logical least-privilege interfaces and disable unused ports where appropriate.
C:Use SSH or secure management where supported and required. Encrypted authenticated management improves control-plane safety. For the stated issue, the appropriate action is: Apply physical access controls and enforce logical least-privilege interfaces and disable unused ports where appropriate.
D:Keep recovery configuration files protected and versioned. Backup confidentiality and integrity support safe restoration. For the stated issue, the appropriate action is: Apply physical access controls and enforce logical least-privilege interfaces and disable unused ports where appropriate.
Question 1055
What observed result BEST validates the change in this wired network case? A distribution uplink fails and traffic takes an excessive time to recover even though alternate Ethernet links exist.
- Aggregate bandwidth improves across diverse flows while a single flow follows its selected member link.
- The alternative path transitions to forwarding within expected convergence bounds after a controlled failover.
- Link restoration makes the Ethernet interface operational and the application succeeds without changing HTTP content.
- Both ports join the intended aggregator with an in-sync collecting/distributing state.
Explanation
Correct Answer
B:The alternative path transitions to forwarding within expected convergence bounds after a controlled failover. Corresponding action: Review RSTP operation, bridge priorities, port roles and edge link classification.
Incorrect Answers
A:That observation verifies a different fault (A technician expects a four-link LAG to make one single TCP transfer four times faster than a member link.). For the question at hand, verify: The alternative path transitions to forwarding within expected convergence bounds after a controlled failover.
C:That observation verifies a different fault (An inventory application sends correct HTTP requests, but an operator blames its Layer 7 data when the distribution uplink has no physical signal.). For the question at hand, verify: The alternative path transitions to forwarding within expected convergence bounds after a controlled failover.
D:That observation verifies a different fault (A pair of uplinks were bundled as dynamic LAG on one side but configured as unrelated standalone ports on the neighbor.). For the question at hand, verify: The alternative path transitions to forwarding within expected convergence bounds after a controlled failover.
Question 1056
Identify the unsafe shortcut to REJECT for the following campus switching situation: An operator assumes any uplink port can be split into four lower-speed interfaces regardless of transceiver mode or switch hardware.
- Avoid assuming web UI and CLI features are identical across devices.
- Use current platform release documentation for model-specific features.
- Use an unsupported cable pinout to claim a fixed optical port has become four independent links.
- Verify the correct device and port before changing production configuration.
Explanation
Correct Answer
C:Use an unsupported cable pinout to claim a fixed optical port has become four independent links. High-speed port breakout depends on port ASIC and model capabilities and specified media. Safer action: Validate supported breakout-capable ports and compatible cables and configure only documented options.
Incorrect Answers
A:Avoid assuming web UI and CLI features are identical across devices. Different platforms expose different supported management methods. For the stated issue, the appropriate action is: Validate supported breakout-capable ports and compatible cables and configure only documented options.
B:Use current platform release documentation for model-specific features. Hardware and AOS-CX capabilities vary across series and versions. For the stated issue, the appropriate action is: Validate supported breakout-capable ports and compatible cables and configure only documented options.
D:Verify the correct device and port before changing production configuration. Accurate change scoping prevents unintended service disruption. For the stated issue, the appropriate action is: Validate supported breakout-capable ports and compatible cables and configure only documented options.
Question 1057
Identify the unsafe shortcut to REJECT for the following campus switching situation: A branch repeatedly saturates its uplink at the end of each month, but reports show only average daily utilization.
- Limit active services to those required by operational policy.
- Report a low weekly average as proof brief periods at 100 percent link utilization never matter.
- Preserve separate management and guest network security boundaries.
- Keep recovery configuration files protected and versioned.
Explanation
Correct Answer
B:Safer action: Use peak and percentile traffic trends and queue drops to plan capacity or traffic prioritization.
Incorrect Answers
A:Limit active services to those required by operational policy. Unused management listeners add unnecessary exposure. For the stated issue, the appropriate action is: Use peak and percentile traffic trends and queue drops to plan capacity or traffic prioritization.
C:Preserve separate management and guest network security boundaries. Least-privilege reachability limits management-plane exposure. For the stated issue, the appropriate action is: Use peak and percentile traffic trends and queue drops to plan capacity or traffic prioritization.
D:Keep recovery configuration files protected and versioned. Backup confidentiality and integrity support safe restoration. For the stated issue, the appropriate action is: Use peak and percentile traffic trends and queue drops to plan capacity or traffic prioritization.
Question 1058
An AOS-CX learner investigates: A switch can ping a host in VLAN25 but a remote host cannot return traffic after an ACL change on the SVI. What underlying concept should guide the response?
- Name resolution failures are distinct from transport/application reachability to a known IP.
- Correlated fault analysis requires trustworthy time and device attribution across distributed logs.
- Repeated MAC moves across multiple ports can signal an Ethernet forwarding loop or duplicate source identity.
- Direction-specific ACL policies can drop return or initiating traffic even with correct VLAN trunks.
Explanation
Correct Answer
D:Direction-specific ACL policies can drop return or initiating traffic even with correct VLAN trunks. Appropriate intervention: Inspect effective routed ACL direction and adjust the approved policy to permit required bidirectional flows.
Incorrect Answers
A:This concept applies to another switch problem (A switch web-management hostname fails but HTTPS works by its IP address from the same workstation.). Direction-specific ACL policies can drop return or initiating traffic even with correct VLAN trunks.
B:This concept applies to another switch problem (Two switches report intermittent spanning-tree changes but their logs use unsynchronized local clocks, obscuring the cause.). Direction-specific ACL policies can drop return or initiating traffic even with correct VLAN trunks.
C:This concept applies to another switch problem (A switch repeatedly learns one server MAC on two trunk ports while broadcast utilization rises sharply.). Direction-specific ACL policies can drop return or initiating traffic even with correct VLAN trunks.
Question 1059
For the following AOS-CX switching task, which intervention should the engineer take FIRST? An installer puts a new in-band management IP on a VLAN SVI that has no active member port and then cannot reach it.
- Replace generic credentials with unique managed administrative identities and supported AAA or role controls.
- Ensure the management VLAN interface is properly enabled and associated with a viable Layer 2 path and route.
- Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security.
- Configure approved management identity, role access and network restrictions for SSH over the intended interface or VRF.
Explanation
Correct Answer
B:Ensure the management VLAN interface is properly enabled and associated with a viable Layer 2 path and route. An SVI depends on VLAN and interface operational state as well as correct IP addressing. Verified result: The management SVI becomes reachable from the allowed operations subnet without mixing visitor traffic.
Incorrect Answers
A:This change serves a different network condition (A new switch uses an administrative identity that all branch installers know, and the same password is reused on every device.), not the issue described. Appropriate response here: Ensure the management VLAN interface is properly enabled and associated with a viable Layer 2 path and route.
C:This change serves a different network condition (A new routed department VLAN cannot obtain DHCP leases from the remote authorized server because its gateway does not relay broadcasts.), not the issue described. Appropriate response here: Ensure the management VLAN interface is properly enabled and associated with a viable Layer 2 path and route.
D:This change serves a different network condition (An initial AOS-CX deployment leaves SSH credentials shared among technicians and management reachable from visitor networks.), not the issue described. Appropriate response here: Ensure the management VLAN interface is properly enabled and associated with a viable Layer 2 path and route.
Question 1060
What specific operational information BEST distinguishes the cause of this issue? A remote closet has forty gigabit users and a 1-Gb/s uplink saturated by backups, yet planners buy more client ports without changing aggregation.
- Compare traffic matrix, oversubscription ratio, interface capacities and queue drop rates.
- Check diff before/after, execution errors, script reruns and checkpoint restore behavior.
- Review product management interface matrix, active services, management VRF and authorized connectivity tests.
- Check platform feature matrix, stacking/VSX software release and intended control-plane topology.
Explanation
Correct Answer
A:Compare traffic matrix, oversubscription ratio, interface capacities and queue drop rates. Access bandwidth and aggregated upstream capacity are separate sizing dimensions. Next step: Size uplink ports and an appropriate access/aggregation switch family based on expected concurrent service traffic.
Incorrect Answers
B:Check diff before/after, execution errors, script reruns and checkpoint restore behavior. This diagnostic addresses another network condition (A script repeatedly creates the same VLAN and port description without checking existing state, generating failures on rerun.). Here inspect: Compare traffic matrix, oversubscription ratio, interface capacities and queue drop rates.
C:This diagnostic addresses another network condition (A field operator assumes every Aruba switch ships with the same always-enabled in-band web GUI and no setup is needed.). Here inspect: Compare traffic matrix, oversubscription ratio, interface capacities and queue drop rates.
D:Check platform feature matrix, stacking/VSX software release and intended control-plane topology. This diagnostic addresses another network condition (An engineer proposes VSX multi-chassis aggregation steps on two fixed access members designed for a VSF stack.). Here inspect: Compare traffic matrix, oversubscription ratio, interface capacities and queue drop rates.