HP HPE6-A86 Practice Test 104
Question 1030
Following the planned correction, which outcome MOST strongly confirms success? A technician issues a VLAN configuration command from the operator context and interprets the rejection as a missing hardware capability.
- The intended configuration applies only to compatible targets with no silent partial deployment.
- Approved API calls return the expected telemetry while anonymous and unauthorized modifications are denied.
- Relevant link flap events are recorded and useful alerts arrive without saturating the management CPU.
- The intended VLAN configuration succeeds only for authorized users, and operator read-only commands remain limited.
Explanation
Correct Answer
D:The intended VLAN configuration succeeds only for authorized users, and operator read-only commands remain limited. Corresponding action: Use the appropriate manager/configuration context and supported privilege for that command without bypassing RBAC.
Incorrect Answers
A:That observation verifies a different fault (A deployment script configures a feature supported only on some AOS-CX releases, and half the switches reject the command.). For the question at hand, verify: The intended VLAN configuration succeeds only for authorized users, and operator read-only commands remain limited.
B:That observation verifies a different fault (A monitoring script makes API requests to a switch using an anonymous shared account and fails after access policies are hardened.). For the question at hand, verify: The intended VLAN configuration succeeds only for authorized users, and operator read-only commands remain limited.
C:That observation verifies a different fault (Operations wants automated alerts on abnormal link flap patterns but plans to poll all interface counters at one-second intervals from a fragile script.). For the question at hand, verify: The intended VLAN configuration succeeds only for authorized users, and operator read-only commands remain limited.
Question 1031
An HPE Aruba Networking switch operator observes this condition: The topology diagram shows one core switch while the actual building now uses a VSF pair with new distribution uplinks. What action BEST addresses the fault?
- Enroll the supported devices in the approved inventory and Central management process with site ownership.
- Apply physical access controls and enforce logical least-privilege interfaces and disable unused ports where appropriate.
- Use peak and percentile traffic trends and queue drops to plan capacity or traffic prioritization.
- Update operational diagrams from verified device inventory and discovered physical/logical connectivity.
Explanation
Correct Answer
D:Update operational diagrams from verified device inventory and discovered physical/logical connectivity. Accurate as-built topology records support fault isolation and reduce risky assumptions during modifications. Verified result: The topology accurately shows members, uplinks and failover paths used by troubleshooting and change approvals.
Incorrect Answers
A:This change serves a different network condition (Three new access switches forward traffic but were never recorded in asset management or Central after emergency installation.), not the issue described. Appropriate response here: Update operational diagrams from verified device inventory and discovered physical/logical connectivity.
B:This change serves a different network condition (A branch's switching rack is accessible from a public hallway, with live management console ports and unused front-panel ports.), not the issue described. Appropriate response here: Update operational diagrams from verified device inventory and discovered physical/logical connectivity.
C:This change serves a different network condition (A branch repeatedly saturates its uplink at the end of each month, but reports show only average daily utilization.), not the issue described. Appropriate response here: Update operational diagrams from verified device inventory and discovered physical/logical connectivity.
Question 1032
An AOS-CX learner investigates: A new switch uses an administrative identity that all branch installers know, and the same password is reused on every device. What underlying concept should guide the response?
- Management-plane DNS depends on suitable resolver configuration and routes in the management path.
- Factory/default and shared credentials undermine accountability and increase management compromise risk.
- STP state is established by protocol election and port-role decisions that are visible in diagnostic output.
- LLDP evidence helps identify the adjacent device but must be correlated with live forwarding state.
Explanation
Correct Answer
B:Factory/default and shared credentials undermine accountability and increase management compromise risk. Appropriate intervention: Replace generic credentials with unique managed administrative identities and supported AAA or role controls.
Incorrect Answers
A:This concept applies to another switch problem (A switch can ping Central's management endpoint by IP but cannot resolve its hostname, blocking enrollment.). Factory/default and shared credentials undermine accountability and increase management compromise risk.
C:This concept applies to another switch problem (A distribution design expects switch A to be root but a technician reads only port LEDs and cannot explain the blocked uplink.). Factory/default and shared credentials undermine accountability and increase management compromise risk.
D:This concept applies to another switch problem (A campus closet's uplink documentation lists switch B on port 1/1/48 while cables were moved to port 1/1/47.). Factory/default and shared credentials undermine accountability and increase management compromise risk.
Question 1033
Following the planned correction, which outcome MOST strongly confirms success? A client ARPs for the final destination on another IPv4 subnet after a technician sets an incorrect on-link mask.
- The client ARPs for its gateway instead of the off-subnet destination and remote traffic succeeds.
- Port and service scans show only authorized management listeners from their approved network.
- Host links attached to distinct switchports negotiate full duplex without hub-shared collisions.
- All authorized readers maintain power as concurrent demand reaches the tested peak.
Explanation
Correct Answer
A:The client ARPs for its gateway instead of the off-subnet destination and remote traffic succeeds. Corresponding action: Correct the client's subnet mask and default gateway so remote targets use router next-hop resolution.
Incorrect Answers
B:That observation verifies a different fault (A new AOS-CX switch accepts remote management protocols never requested in the commissioning standard.). For the question at hand, verify: The client ARPs for its gateway instead of the off-subnet destination and remote traffic succeeds.
C:That observation verifies a different fault (An operator adds a repeater-style hub behind a managed switch and expects independent full-duplex Ethernet per hub port.).
D:That observation verifies a different fault (A stack of badge readers reboots during shift change after the access switch exhausts its available PoE budget.). For the question at hand, verify: The client ARPs for its gateway instead of the off-subnet destination and remote traffic succeeds.
Question 1034
What specific operational information BEST distinguishes the cause of this issue? A lab switch allows Telnet logins across an untrusted contractor VLAN despite password authentication being enabled.
- Check route selection and prefix lengths using the route table and a destination-specific lookup.
- Capture login transport, validate SSH host key, and review management-port ACL and service settings.
- Check VSF topology, role/member state, stack port diagnostics and platform support.
- Inspect effective SNMP version, access lists, user roles and wire traffic exposure.
Explanation
Correct Answer
B:Capture login transport, validate SSH host key, and review management-port ACL and service settings. Telnet transmits session content without SSH transport encryption and is unsuitable for untrusted administration. Next step: Disable insecure remote terminal access and permit supported SSH administration from a restricted management network.
Incorrect Answers
A:This diagnostic addresses another network condition (A switch has routes 10.0.0.0/8 and 10.24.32.0/20 but an operator expects the /8 path for traffic to 10.24.35.9.). Here inspect: Capture login transport, validate SSH host key, and review management-port ACL and service settings.
C:Check VSF topology, role/member state, stack port diagnostics and platform support. This diagnostic addresses another network condition (A branch VSF stack reports that one member no longer participates after a stacking cable was unplugged.). Here inspect: Capture login transport, validate SSH host key, and review management-port ACL and service settings.
D:Inspect effective SNMP version, access lists, user roles and wire traffic exposure. This diagnostic addresses another network condition (A monitoring station polls switch counters via SNMPv2c using a default community string discoverable by guest clients.). Here inspect: Capture login transport, validate SSH host key, and review management-port ACL and service settings.
Question 1035
Which diagnostic-then-correction sequence BEST addresses this network situation? A planned reboot changes the STP root unexpectedly because preferred bridge priority was applied only to the running configuration.
- First, Inspect DSCP values, queue drops, uplink utilization and call quality measurements. Then, Review bandwidth, classification, trust and queue policies, then enforce appropriate congestion treatment.
- First, Record baseline and follow-up counters, interface uptime and current traffic volume. Then, Compare time-normalized counter deltas under a known traffic interval before determining corrective work.
- First, Review MAC move events, trunk topology, STP roles and broadcast counters. Then, Find and correct the unintended Layer 2 loop or unapproved bridge and restore STP protection.
- First, Compare show spanning-tree bridge priority, startup configuration and reboot chronology. Then, Restore documented root priority and persist supported configuration before controlled failover testing.
Explanation
Correct Answer
D:STP election uses active bridge identifiers, so unsaved configurations can alter forwarding topology.
Incorrect Answers
A:This plan investigates a different issue (Voice calls degrade during large backups, and the switch shows voice queue drops even though all VLANs are correctly carried.). For the case described, inspect: Compare show spanning-tree bridge priority, startup configuration and reboot chronology.
B:This plan investigates a different issue (A technician sees a large cumulative error counter and assumes a currently active fault despite no recent increment.). For the case described, inspect: Compare show spanning-tree bridge priority, startup configuration and reboot chronology.
C:This plan investigates a different issue (A switch repeatedly learns one server MAC on two trunk ports while broadcast utilization rises sharply.). For the case described, inspect: Compare show spanning-tree bridge priority, startup configuration and reboot chronology.
Question 1036
Select TWO statements: the correct intervention and its observed verification in this AOS-CX case. A branch announces a broad OSPF route for a network it does not actually reach, attracting traffic into a dead end.
- Action: Determine whether the attached device is appropriate and correct its cabling or edge-policy treatment before recovery.
- Action: Correct invalid advertisement or underlying reachability and validate the intended prefix origins.
- Unsafe shortcut: Increase the false route priority so every site sends still more traffic to the branch.
- Verification: The responsible port/bridge is isolated and normal broadcast rates resume.
- Verification: Traffic selects an origin that really forwards to the destination and loss resolves.
Explanation
Correct Answers
B:Action: Correct invalid advertisement or underlying reachability and validate the intended prefix origins. Routing advertisements must reflect real reachable prefixes; incorrect routing information can create blackholes.
E:Verification: Traffic selects an origin that really forwards to the destination and loss resolves. Routing advertisements must reflect real reachable prefixes; incorrect routing information can create blackholes.
Incorrect Answers
A:This remedy fits a different fault (A newly deployed access point cannot connect after switch security protection placed its port into a disabled state on detecting a BPDU.). For this case use: Correct invalid advertisement or underlying reachability and validate the intended prefix origins.
C:Routing advertisements must reflect real reachable prefixes; incorrect routing information can create blackholes.
D:This is validation for another condition (A large spike in broadcast traffic follows a new office wall jack installation and staff cannot locate the originating port.).
Question 1037
Which proposed action would be LEAST defensible for this AOS-CX or network problem? A new routed department VLAN cannot obtain DHCP leases from the remote authorized server because its gateway does not relay broadcasts.
- Correlate link fault counters with time and live traffic.
- Restrict monitoring permissions to the required data access.
- Move every department device into the server's management VLAN to avoid DHCP relay.
- Limit active services to those required by operational policy.
Explanation
Correct Answer
C:Move every department device into the server's management VLAN to avoid DHCP relay. DHCP discover broadcasts need an authorized relay across a routed boundary. Safer action: Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security.
Incorrect Answers
A:Correlate link fault counters with time and live traffic. Cumulative counters must be interpreted against a baseline. For the stated issue, the appropriate action is: Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security.
B:Restrict monitoring permissions to the required data access. Read-only telemetry rarely needs broad configuration privileges. For the stated issue, the appropriate action is: Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security.
D:Limit active services to those required by operational policy. Unused management listeners add unnecessary exposure. For the stated issue, the appropriate action is: Configure the supported DHCP relay/helper function at the correct L3 gateway and review network security.
Question 1038
What mistaken approach is MOST likely to worsen this networking fault? After rewiring a campus distribution panel, staff see conflicting port-label records for one access uplink.
- Choose switch hardware against traffic, PoE, and resiliency requirements.
- Monitor the effect of an uplink change on real applications.
- Review current NTP and syslog health during an incident.
- Assume a patch-panel sticker is always more accurate than live neighbor information.
Explanation
Correct Answer
D:Safer action: Use LLDP neighbor data and actual physical port tracing to identify the peer before changing trunk policy.
Incorrect Answers
A:Choose switch hardware against traffic, PoE, and resiliency requirements. Product capabilities vary independently of procurement price. For the stated issue, the appropriate action is: Use LLDP neighbor data and actual physical port tracing to identify the peer before changing trunk policy.
B:Physical link state alone does not guarantee service correctness. For the stated issue, the appropriate action is: Use LLDP neighbor data and actual physical port tracing to identify the peer before changing trunk policy.
C:Review current NTP and syslog health during an incident. Time-aligned logs support sound fault analysis. For the stated issue, the appropriate action is: Use LLDP neighbor data and actual physical port tracing to identify the peer before changing trunk policy.
Question 1039
Before applying a production change, what diagnostic should the technician prioritize? An AOS-CX switch management port has a valid IPv4 address, but off-subnet operations workstations cannot access it.
- Inspect show ip interface brief, SVI state, routing table and client ARP.
- Check interface lag membership, show lacp interfaces, partner state and trunk tagging.
- Review show running-config, policy counters, backup diff and a negative connectivity test.
- Compare show ip route vrf mgmt, source ping, gateway ARP and firewall results.
Explanation
Correct Answer
D:Compare show ip route vrf mgmt, source ping, gateway ARP and firewall results. OOB management path reachability depends on routes within the correct management routing instance. Next step: Set a reachable gateway or appropriate route in the management VRF while preserving network isolation.
Incorrect Answers
A:This diagnostic addresses another network condition (An engineer creates VLAN70 on a Layer 3 AOS-CX switch but puts the gateway address on the wrong VLAN SVI.). Here inspect: Compare show ip route vrf mgmt, source ping, gateway ARP and firewall results.
B:This diagnostic addresses another network condition (Two server NICs are supposed to use a dynamic LAG but the switch has interfaces configured separately with different VLAN modes.). Here inspect: Compare show ip route vrf mgmt, source ping, gateway ARP and firewall results.
C:This diagnostic addresses another network condition (A remote change to an access switch unexpectedly removes a security filter and the team has no postchange verification checklist.). Here inspect: Compare show ip route vrf mgmt, source ping, gateway ARP and firewall results.
Question 1040
Identify the unsafe shortcut to REJECT for the following campus switching situation: A local VLAN can reach its own gateway but cannot reach outside prefixes because the core routing table lacks a default path.
- Validate switch software image compatibility before deployment.
- Configure an ARP static entry for each internet website rather than the required gateway route.
- Verify port VLAN membership with operational state rather than ticket labels.
- Separate an Ethernet tagging fault from an IP route fault.
Explanation
Correct Answer
B:Safer action: Install a reviewed default route to the valid upstream next hop where the switch is a Layer 3 router.
Incorrect Answers
A:Validate switch software image compatibility before deployment. Unsupported images can prevent reliable device startup. For the stated issue, the appropriate action is: Install a reviewed default route to the valid upstream next hop where the switch is a Layer 3 router.
C:Verify port VLAN membership with operational state rather than ticket labels. Actual forwarding can differ from intended configuration. For the stated issue, the appropriate action is: Install a reviewed default route to the valid upstream next hop where the switch is a Layer 3 router.
D:Separate an Ethernet tagging fault from an IP route fault. Correct problem-layer isolation avoids ineffective reconfiguration. For the stated issue, the appropriate action is: Install a reviewed default route to the valid upstream next hop where the switch is a Layer 3 router.