Question 30
A campus extends two-tier managed switching across a narrow uplink and experiences unexpected bottlenecks. Which diagnostic evidence should the FortiSwitch administrator examine FIRST?
Explanation
Correct Answer
Check managed tree, ISL link health, model compatibility, VLAN carriage, depth limitations and upstream aggregate status. A FortiGate controls each FortiSwitch through the managed Layer-2 topology, but downstream reachability depends on upstream FortiLink links. The paired action is: Build a documented supported FortiSwitch daisy chain or multi-tier topology with adequate ISL uplink capacity and safeguards.
Incorrect Answers
Inspect shared-port VLAN diff, tenant inventory, VDOM policy, change approval and representative positive/negative access tests. These observations are applicable to Multi-tenant change verification and rollback, but would not isolate the main failure first. The decisive evidence is: Check managed tree, ISL link health, model compatibility, VLAN carriage, depth limitations and upstream aggregate status.
Review firmware compatibility, release notes, current image, boot fallback, managed switch inventory and upgrade sequencing. These observations are applicable to Firmware and lifecycle preparation for FortiSwitch, but would not isolate the main failure first. The decisive evidence is: Check managed tree, ISL link health, model compatibility, VLAN carriage, depth limitations and upstream aggregate status.
Inspect DHCP server permitted list, Option 82 insertion/trust state, relay path, client bindings and lease evidence. These observations are applicable to DHCP server allowlist and Option 82 validation, but would not isolate the main failure first. The decisive evidence is: Check managed tree, ISL link health, model compatibility, VLAN carriage, depth limitations and upstream aggregate status.