Question 120
An engineer enables legacy public read-write SNMP community strings to save time and exposes management data. Which TWO complementary steps identify the appropriate FortiSwitch response AND the evidence needed to verify it? Select TWO.
Explanation
Correct Answers
Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy. Flow samples are estimates and counters vary by port; collecting telemetry cannot replace a controlled packet capture when headers are needed. The paired action is: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. This is the diagnostic or verification half of the requested TWO-step pair.
Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Flow samples are estimates and counters vary by port; collecting telemetry cannot replace a controlled packet capture when headers are needed. Verify the action with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy. This is the configuration or remediation half of the requested TWO-step pair.
Incorrect Answers
Collect relevant FortiSwitch controller diagnostics, switch system events and targeted status output before making configuration changes. This step concerns FortiSwitch diagnostic commands and logs and is not part of the required paired solution. The correct action and evidence are: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Together with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.
Inspect FortiGate HA active member, FortiLink aggregate state, ISL, MCLAG peer link, standby path and STP roles. This step concerns FortiLink HA and MCLAG topology faults and is not part of the required paired solution. The correct action and evidence are: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Together with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.
Critical telephony and wireless endpoints receive continuous intended power without overrunning PSU capacity. This step concerns Power over Ethernet port controls and budgets and is not part of the required paired solution. The correct action and evidence are: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Together with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.