cert
cert-1
cert-2

Pass CompTIA SK0-005 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
SK0-005 Exam - Verified By Experts
SK0-005 Premium Bundle
$29.98

SK0-005 Premium Bundle

$79.99
$109.97
  • Premium File 617 Questions & Answers. Last update: Nov 13, 2026
  • Training Course 139 Video Lectures
  • Study Guide 533 Pages
 
$109.97
$79.99
accept 21 downloads in last 7 days
block-screenshots
Purchase CompTIA SK0-005 Exam Training Products Individually
CompTIA SK0-005 Premium File
Premium File 617 Q&A
$76.99$69.99
CompTIA SK0-005 Video Training Course
Training Course 139 Lectures
$21.99 $19.99
CompTIA SK0-005 PDF Study Guide
Study Guide 533 Pages
$21.99 $19.99
CompTIA SK0-005 Practice Test 61

Question 600

A change board is planning a verified response to this server event: A temporary firewall bypass restores a web service but remains undocumented and exposed after incident closure. For the Escalation, rollback and post-incident closure issue, which response elements belong in the approved plan? Select THREE answers.

  1. Contain unapproved egress, preserve flow and endpoint evidence and validate allowed destinations before reopening paths.
  2. Capture baseline symptoms, timeline, recent changes, comparison hosts and test results before modifying production.
  3. Leave emergency security bypasses permanent because the application now responds.
  4. Escalate using evidence and severity thresholds, apply a reversible supported workaround and remove temporary exceptions after root-cause review.
  5. Check outage severity, vendor case criteria, change ticket, workaround expiry and root cause evidence.
  6. Service is restored within response targets, temporary risk is removed and a reproducible fix is documented.

Explanation

Correct Answer

D:

Incident resolution includes timely escalation, safe rollback and documented follow-through, not just a green monitor. A successful outcome is: Service is restored within response targets, temporary risk is removed and a reproducible fix is documented.

E:

These observations investigate the exact Escalation, rollback and post-incident closure failure rather than unrelated components. The expected technical relationship is: Incident resolution includes timely escalation, safe rollback and documented follow-through, not just a green monitor.

F:

Incident resolution includes timely escalation, safe rollback and documented follow-through, not just a green monitor. This evidence tests whether the original Escalation, rollback and post-incident closure weakness has been corrected under realistic conditions.

Incorrect Answers

A:

This statement concerns Unauthorized outbound traffic and exfiltration detection, a different Server+ technical control. It does not directly address the reported Escalation, rollback and post-incident closure fault or prove its repair. For this incident, the relevant principle is: Incident resolution includes timely escalation, safe rollback and documented follow-through, not just a green monitor.

B:

This statement concerns Structured troubleshooting hypothesis and controlled change, a different Server+ technical control. It does not directly address the reported Escalation, rollback and post-incident closure fault or prove its repair. For this incident, the relevant principle is: Incident resolution includes timely escalation, safe rollback and documented follow-through, not just a green monitor. A targeted investigation checks: Check outage severity, vendor case criteria, change ticket, workaround expiry and root cause evidence. The desired recovery condition is: Service is restored within response targets, temporary risk is removed and a reproducible fix is documented.

C:

Incident: A temporary firewall bypass restores a web service but remains undocumented and exposed after incident closure.

Question 601

A server administrator is investigating a server issue involving thermal shutdown and heatsink diagnostics: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.

  1. Correlate ECC and memory training events with physical slots, then replace faulty qualified DIMMs using approved service steps.
  2. Trace and test PSU, cables, PDU, UPS and breaker paths under a safely controlled maintenance procedure.
  3. Inspect cooling path, heatsink mounting and sensor telemetry, then correct the thermal fault before increasing load.
  4. Disable thermal protections to keep an overheating server online.

Explanation

Correct Answer

C:

Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. For this case, A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled.

Incorrect Answers

A:

This statement concerns Correctable ECC error escalation, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

B:

That option would trace and test PSU, cables, PDU, UPS and breaker paths under a safely controlled maintenance procedure, but it addresses a different concern. Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use.

D:

This is the unsafe shortcut in the Thermal shutdown and heatsink diagnostics scenario, not a justified remediation or diagnostic. Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use.

Question 602

While reviewing the CompTIA Server+ administration incident, a technician learns: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled. Which principle most directly explains how to address the described issue safely? Select ONE best answer.

  1. Link-up alone does not establish link quality; CRC, FCS, drops and duplex mismatches reveal layer-one or layer-two faults.
  2. Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use.
  3. Tagged VLAN traffic must be permitted end-to-end; routing changes do not repair a missing layer-two VLAN path.
  4. A repeatable incident method isolates causes and prevents uncontrolled fixes from introducing new failures.

Explanation

Correct Answer

B:

The acceptance test is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

Incorrect Answers

A:

This statement concerns NIC port errors and duplex mismatch, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

C:

This statement concerns Incorrect switch VLAN trunk allowance, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

D:

This statement concerns Structured troubleshooting hypothesis and controlled change, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

Question 603

Before a server change is approved, the on-call engineer receives this incident report: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.

  1. Review PSU fault logs, UPS/PDU event history, load measurements and path diagrams.
  2. Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs.
  3. Inspect interface counters at both ends, cable tests, transceiver diagnostics and negotiated parameters.
  4. Disable thermal protections to keep an overheating server online.

Explanation

Correct Answer

B:

These observations investigate the exact Thermal shutdown and heatsink diagnostics failure rather than unrelated components. Incident: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled.

Incorrect Answers

A:

For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs.

C:

For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. This statement concerns NIC port errors and duplex mismatch, a different Server+ technical control.

D:

This is the unsafe shortcut in the Thermal shutdown and heatsink diagnostics scenario, not a justified remediation or diagnostic. Incident: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled.

Question 604

After the team implements a targeted remediation for Thermal shutdown and heatsink diagnostics, the original incident was: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.

  1. Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.
  2. Hardware reports no recurring ECC faults and memory validation passes under representative load.
  3. Only intended VLANs traverse the trunk and test VMs reach their approved peers.
  4. Affected systems are contained, persistent mechanisms removed and monitored restoration shows no renewed indicators.

Explanation

Correct Answer

A:

Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. Incident: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled.

Incorrect Answers

B:

This statement concerns Correctable ECC error escalation, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair.

C:

This statement concerns Incorrect switch VLAN trunk allowance, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair.

D:

This statement concerns Malware persistence and containment, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

Question 605

A change board is planning a verified response to this server event: A CPU host powers off under load after a heatsink replacement because thermal compound and fan attachment were mishandled. For the Thermal shutdown and heatsink diagnostics issue, which response elements belong in the approved plan? Select ONE best answer.

  1. Examine controller cache mode, BBU/flash status, workload write latency and vendor alerts.
  2. Inspect cooling path, heatsink mounting and sensor telemetry, then correct the thermal fault before increasing load. Then validate the change by confirming: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.
  3. Resolve physical media and negotiated speed/duplex compatibility, replacing defective optics or cabling as evidence dictates.
  4. Disable thermal protections to keep an overheating server online.

Explanation

Correct Answer

B:

Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. The proposed change and outcome assessment work together for Thermal shutdown and heatsink diagnostics.

Incorrect Answers

A:

This statement concerns Write cache battery and storage performance, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

C:

This statement concerns NIC port errors and duplex mismatch, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair.

D:

This is the unsafe shortcut in the Thermal shutdown and heatsink diagnostics scenario, not a justified remediation or diagnostic. Discriminate using: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs.

Question 606

A server administrator is investigating a server issue involving thermal shutdown and heatsink diagnostics: A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.

  1. Inspect cooling path, heatsink mounting and sensor telemetry, then correct the thermal fault before increasing load.
  2. Restore the supported boot entry or known-good kernel and rebuild boot images as needed using tested recovery media.
  3. Back up critical data, inspect controller/media events, replace failed components and rebuild with monitored redundancy.
  4. Disable thermal protections to keep an overheating server online.

Explanation

Correct Answer

A:

Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A successful outcome is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

Incorrect Answers

B:

This statement concerns Boot loader and failed update recovery, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

C:

This statement concerns RAID degraded state and predictive drive failure, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

D:

This is the unsafe shortcut in the Thermal shutdown and heatsink diagnostics scenario, not a justified remediation or diagnostic. Incident: A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake.

Question 607

While reviewing the CompTIA Server+ administration incident, a technician learns: A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake. Which principle most directly explains how to address the described issue safely? Select ONE best answer.

  1. Boot failures may arise before services start; distinguish firmware/bootloader problems from application outages.
  2. Degraded or unstable storage may be one additional fault from data loss; immediate integrity and rebuild priorities matter.
  3. Unusual outbound volume and destinations may indicate exfiltration; investigation must preserve evidence and scope blast radius.
  4. Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use.

Explanation

Correct Answer

D:

The acceptance test is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown. This is the controlling principle for the reported Thermal shutdown and heatsink diagnostics incident.

Incorrect Answers

A:

This statement concerns Boot loader and failed update recovery, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair.

B:

This statement concerns RAID degraded state and predictive drive failure, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair.

C:

This statement concerns Unauthorized outbound traffic and exfiltration detection, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

Question 608

Before a server change is approved, the on-call engineer receives this incident report: A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.

  1. Correlate firewall/NetFlow records, process ownership, DNS logs, DLP alerts and identity sign-ins.
  2. Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs.
  3. Review PSU fault logs, UPS/PDU event history, load measurements and path diagrams.
  4. Disable thermal protections to keep an overheating server online.

Explanation

Correct Answer

B:

These observations investigate the exact Thermal shutdown and heatsink diagnostics failure rather than unrelated components. The expected technical relationship is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use.

Incorrect Answers

A:

For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. This statement concerns Unauthorized outbound traffic and exfiltration detection, a different Server+ technical control.

C:

For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. This statement concerns PSU and power event isolation, a different Server+ technical control.

D:

Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use.

Question 609

After the team implements a targeted remediation for Thermal shutdown and heatsink diagnostics, the original incident was: A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.

  1. The host boots the approved OS reliably through several cold boots with disk access intact.
  2. The application passes functional load tests without repeating its prior exceptions.
  3. Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.
  4. Transfer throughput and latency recover while physical error counters remain stable.

Explanation

Correct Answer

C:

Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. Incident: A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake.

Incorrect Answers

A:

This statement concerns Boot loader and failed update recovery, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use.

B:

This statement concerns Application crash and dependency triage, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

D:

This statement concerns NIC port errors and duplex mismatch, a different Server+ technical control. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair. For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. A targeted investigation checks: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

Question 610

A change board is planning a verified response to this server event: A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake. For the Thermal shutdown and heatsink diagnostics issue, which response elements belong in the approved plan? Select TWO answers.

  1. Contain unapproved egress, preserve flow and endpoint evidence and validate allowed destinations before reopening paths.
  2. Transfer throughput and latency recover while physical error counters remain stable.
  3. Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs.
  4. Inspect cooling path, heatsink mounting and sensor telemetry, then correct the thermal fault before increasing load.
  5. Disable thermal protections to keep an overheating server online.

Explanation

Correct Answer

C:

These observations investigate the exact Thermal shutdown and heatsink diagnostics failure rather than unrelated components. Confirm remediation through: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

D:

Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. For this case, A rack server throttles every afternoon although CPU utilization is modest; inlet sensors show a blocked cold-air intake.

Incorrect Answers

A:

For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. The desired recovery condition is: Sustained stress tests run within component thermal limits without unexpected throttling or shutdown.

B:

For this incident, the relevant principle is: Thermal throttling and protective shutdown may result from heat transfer or airflow faults even without high average CPU use. It does not directly address the reported Thermal shutdown and heatsink diagnostics fault or prove its repair.

E:

Discriminate using: Compare inlet/CPU temperatures, fan RPM, heatsink seating, thermal history and throttling event logs.