CompTIA SK0-005 Practice Test 14
Question 130
A change board is planning a verified response to this server event: An administrator updates RAID controller firmware across all storage nodes at once without checking the vendor-supported driver and firmware matrix. For the Firmware compatibility and staged maintenance issue, which response elements belong in the approved plan? Select TWO answers.
- Record installed firmware/driver versions, vendor advisories, compatibility notes and maintenance dependency order.
- Place BMC access on an isolated management network, change default credentials, restrict administrator access and maintain supported firmware.
- Validate the hardware compatibility matrix, test firmware and drivers in a pilot, arrange rollback and stagger production maintenance.
- Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
- Install the newest firmware everywhere simultaneously without checking compatibility or rollback.
Explanation
Correct Answer
A:These observations investigate the exact Firmware compatibility and staged maintenance failure rather than unrelated components. Use findings to decide whether to: Validate the hardware compatibility matrix, test firmware and drivers in a pilot, arrange rollback and stagger production maintenance.
C:BIOS, BMC, controller firmware and drivers can have version dependencies; simultaneous fleet updates amplify risk. This is the appropriate targeted correction for Firmware compatibility and staged maintenance.
Incorrect Answers
B:For this incident, the relevant principle is: BIOS, BMC, controller firmware and drivers can have version dependencies; simultaneous fleet updates amplify risk. It does not directly address the reported Firmware compatibility and staged maintenance fault or prove its repair.
D:For this incident, the relevant principle is: BIOS, BMC, controller firmware and drivers can have version dependencies; simultaneous fleet updates amplify risk. This statement concerns Preventive hardware maintenance and spares, a different Server+ technical control.
E:Incident: An administrator updates RAID controller firmware across all storage nodes at once without checking the vendor-supported driver and firmware matrix.
Question 131
A server administrator is investigating a server issue involving preventive hardware maintenance and spares: A remote branch stores no spare fans or drives and repeatedly waits days for replacements after predictable wear alerts. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.
- Wait for complete service outage before acting on persistent hardware health alarms.
- Validate the hardware compatibility matrix, test firmware and drivers in a pilot, arrange rollback and stagger production maintenance.
- Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks.
- Check component hot-swap support, follow power isolation requirements and use approved ESD handling procedures.
Explanation
Correct Answer
C:Before rollout, confirm the problem with: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
Incorrect Answers
A:This is the unsafe shortcut in the Preventive hardware maintenance and spares scenario, not a justified remediation or diagnostic. Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
B:That option would validate the hardware compatibility matrix, test firmware and drivers in a pilot, arrange rollback and stagger production maintenance, but it addresses a different concern. Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
D:That option would check component hot-swap support, follow power isolation requirements and use approved ESD handling procedures, but it addresses a different concern. Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
Question 132
While reviewing the CompTIA Server+ administration incident, a technician learns: A remote branch stores no spare fans or drives and repeatedly waits days for replacements after predictable wear alerts. Which principle most directly explains how to address the described issue safely? Select ONE best answer.
- Two PSUs are not a redundant power design when both depend on one upstream power device or circuit.
- RAID 0 offers no disk fault tolerance; parity and mirrors have different write and rebuild characteristics, and none replaces backup.
- Rack placement must satisfy structural loading, chassis mounting specifications and designed airflow; a physically fitting rail is not proof of safe installation.
- Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
Explanation
Correct Answer
D:Applying it leads to this operational action: Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks. This is the controlling principle for the reported Preventive hardware maintenance and spares incident.
Incorrect Answers
A:This statement concerns Dual power supply fault domains, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
B:This statement concerns RAID fault tolerance versus performance, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
C:This statement concerns Rack weight, rail compatibility and airflow, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
Question 133
Before a server change is approved, the on-call engineer receives this incident report: A remote branch stores no spare fans or drives and repeatedly waits days for replacements after predictable wear alerts. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.
- Review chassis and rack load documents, weight distribution, rail part numbers, inlet temperature and actual front/rear clearances.
- Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements.
- Wait for complete service outage before acting on persistent hardware health alarms.
- Record installed firmware/driver versions, vendor advisories, compatibility notes and maintenance dependency order.
Explanation
Correct Answer
B:These observations investigate the exact Preventive hardware maintenance and spares failure rather than unrelated components. The expected technical relationship is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
Incorrect Answers
A:For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements.
C:This is the unsafe shortcut in the Preventive hardware maintenance and spares scenario, not a justified remediation or diagnostic. Discriminate using: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements.
D:For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. This statement concerns Firmware compatibility and staged maintenance, a different Server+ technical control.
Question 134
After the team implements a targeted remediation for Preventive hardware maintenance and spares, the original incident was: A remote branch stores no spare fans or drives and repeatedly waits days for replacements after predictable wear alerts. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.
- The rebuild completes without new errors and the controller reports all expected redundancy restored.
- A planned single-path outage leaves the server powered without overloading the remaining path.
- Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
- The component is replaced per approved procedure and POST or hardware diagnostics show normal health.
Explanation
Correct Answer
C:Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. Incident: A remote branch stores no spare fans or drives and repeatedly waits days for replacements after predictable wear alerts.
Incorrect Answers
A:This statement concerns Hot spare eligibility and rebuild supervision, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
B:This statement concerns Dual power supply fault domains, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair.
D:This statement concerns ESD and hot-swap replacement procedure, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
Question 135
A change board is planning a verified response to this server event: A remote branch stores no spare fans or drives and repeatedly waits days for replacements after predictable wear alerts. For the Preventive hardware maintenance and spares issue, which response elements belong in the approved plan? Select ONE best answer.
- Wait for complete service outage before acting on persistent hardware health alarms.
- Inventory BMC firmware and accounts, scan exposed management interfaces and review management VLAN ACLs.
- Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks. Then validate the change by confirming: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
- Check the rack's weight rating, supported rails, front-to-back clearance and cold/hot aisle arrangement; mount heavier equipment low and preserve unobstructed cooling.
Explanation
Correct Answer
C:Before modifying systems, gather: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements.
Incorrect Answers
A:This is the unsafe shortcut in the Preventive hardware maintenance and spares scenario, not a justified remediation or diagnostic. Incident: A remote branch stores no spare fans or drives and repeatedly waits days for replacements after predictable wear alerts.
B:This statement concerns Out-of-band management network, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
D:That option would check the rack's weight rating, supported rails, front-to-back clearance and cold/hot aisle arrangement; mount heavier equipment low and preserve unobstructed cooling, but it addresses a different concern. Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
Question 136
A server administrator is investigating a server issue involving preventive hardware maintenance and spares: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.
- Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks.
- Use dedicated or appropriately isolated iSCSI paths with supported MPIO, correct initiator/target configuration and measured QoS.
- Wait for complete service outage before acting on persistent hardware health alarms.
- Place BMC access on an isolated management network, change default credentials, restrict administrator access and maintain supported firmware.
Explanation
Correct Answer
A:Before rollout, confirm the problem with: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. For this case, A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks.
Incorrect Answers
B:That option would use dedicated or appropriately isolated iSCSI paths with supported MPIO, correct initiator/target configuration and measured QoS, but it addresses a different concern. Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
C:This is the unsafe shortcut in the Preventive hardware maintenance and spares scenario, not a justified remediation or diagnostic. Incident: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks.
D:This statement concerns Out-of-band management network, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
Question 137
While reviewing the CompTIA Server+ administration incident, a technician learns: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks. Which principle most directly explains how to address the described issue safely? Select ONE best answer.
- Out-of-band controllers are privileged hardware management interfaces and need independent network and identity protections.
- Stable iSCSI performance and resilience depend on end-to-end network path design and host multipathing, not simply the number of NICs.
- Two PSUs are not a redundant power design when both depend on one upstream power device or circuit.
- Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
Explanation
Correct Answer
D:Applying it leads to this operational action: Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks.
Incorrect Answers
A:This statement concerns Out-of-band management network, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair.
B:This statement concerns iSCSI network isolation and MPIO, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
C:This statement concerns Dual power supply fault domains, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
Question 138
Before a server change is approved, the on-call engineer receives this incident report: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.
- Inspect qualified hardware lists, slot/channel maps, POST logs, detected speeds and NUMA memory distribution.
- Wait for complete service outage before acting on persistent hardware health alarms.
- Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements.
- Trace PSU cords through PDU, UPS and breaker paths; compare load and failover ratings against peak demand.
Explanation
Correct Answer
C:These observations investigate the exact Preventive hardware maintenance and spares failure rather than unrelated components. Incident: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks.
Incorrect Answers
A:For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. Incident: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks.
B:Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
D:For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. This statement concerns Dual power supply fault domains, a different Server+ technical control.
Question 139
After the team implements a targeted remediation for Preventive hardware maintenance and spares, the original incident was: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.
- Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
- The component is replaced per approved procedure and POST or hardware diagnostics show normal health.
- The selected array meets latency and capacity targets and remains accessible during the specified supported drive failure.
- Only authorized administrators can reach and authenticate to the updated BMC over the isolated path.
Explanation
Correct Answer
A:Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. Incident: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks.
Incorrect Answers
B:This statement concerns ESD and hot-swap replacement procedure, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
C:This statement concerns RAID fault tolerance versus performance, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. A targeted investigation checks: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. The desired recovery condition is: Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
D:This statement concerns Out-of-band management network, a different Server+ technical control. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair. For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
Question 140
A change board is planning a verified response to this server event: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks. For the Preventive hardware maintenance and spares issue, which response elements belong in the approved plan? Select TWO answers.
- Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements.
- Connect redundant PSUs to independently protected PDU and UPS paths where available; size each path to carry the required load.
- Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks.
- Wait for complete service outage before acting on persistent hardware health alarms.
- The component is replaced per approved procedure and POST or hardware diagnostics show normal health.
Explanation
Correct Answer
A:These observations investigate the exact Preventive hardware maintenance and spares failure rather than unrelated components. Use findings to decide whether to: Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks.
C:Before rollout, confirm the problem with: Correlate sensor alarms, fault trends, part numbers, vendor lifecycle notices and support response agreements. This is the appropriate targeted correction for Preventive hardware maintenance and spares.
Incorrect Answers
B:For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. It does not directly address the reported Preventive hardware maintenance and spares fault or prove its repair.
D:Incident: A rack facility dismisses rising fan errors and battery warnings because the servers are still answering application health checks.
E:For this incident, the relevant principle is: Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements. This statement concerns ESD and hot-swap replacement procedure, a different Server+ technical control.