CompTIA N10-009 Practice Test 32
Question 310
An older handheld scanner cannot join a WPA3-only SSID but can use an approved WPA2-Enterprise profile. A colleague instead suggests: Disable encryption entirely on the main corporate SSID for the scanner. Which finding MOST specifically explains why that suggestion is unsuitable?
- Maximum width can worsen contention where overlapping cells reuse limited channels.
- Security must balance device compatibility and risk with strong individual authentication.
- Replacing legacy equipment enables stronger WLAN protections.
- Unencrypted production WLAN traffic creates avoidable exposure.
Explanation
Correct Answer
D:Unencrypted production WLAN traffic creates avoidable exposure. This flaw directly concerns the proposed action: Disable encryption entirely on the main corporate SSID for the scanner.
Incorrect Answers
A:This flaw concerns a different case in objective 2.3: A dense lecture hall has many compatible 5GHz clients competing on a few wide channels. The current rejected proposal is: Disable encryption entirely on the main corporate SSID for the scanner.
B:This explains why the recommended control works: Provide a segmented compatible WPA2-Enterprise WLAN while scheduling device replacement.
C:This rationale belongs to a later changed condition: New scanner hardware supports modern WPA3-Enterprise controls.
Question 311
An older handheld scanner cannot join a WPA3-only SSID but can use an approved WPA2-Enterprise profile. After applying the solution 'Provide a segmented compatible WPA2-Enterprise WLAN while scheduling device replacement.', which observation MOST directly proves that the requirement was met?
- Test devices associate to their supported bands and access approved services.
- A density survey shows stable airtime utilization and acceptable per-client throughput.
- Approval is recorded for 'Provide a segmented compatible WPA2-Enterprise WLAN while scheduling device replacement.' but no operational validation is performed.
- The scanner authenticates to a constrained VLAN and cannot access unrelated services.
Explanation
Correct Answer
D:The scanner authenticates to a constrained VLAN and cannot access unrelated services. It tests the intended outcome because security must balance device compatibility and risk with strong individual authentication.
Incorrect Answers
A:This test addresses a separate problem: An office needs newer clients to join 6GHz while preserving support for older 5GHz devices.
B:This observation is for a different condition: A dense lecture hall has many compatible 5GHz clients competing on a few wide channels. It does not directly test the target outcome: An older handheld scanner cannot join a WPA3-only SSID but can use an approved WPA2-Enterprise profile.
C:The missing direct test is: The scanner authenticates to a constrained VLAN and cannot access unrelated services.
Question 312
The original case was: An older handheld scanner cannot join a WPA3-only SSID but can use an approved WPA2-Enterprise profile. The requirement then changes: New scanner hardware supports modern WPA3-Enterprise controls. Which revised action BEST meets this new condition?
- Disable encryption entirely on the main corporate SSID for the scanner.
- Migrate devices to stronger supported authentication with staged validation.
- Provide a segmented compatible WPA2-Enterprise WLAN while scheduling device replacement.
- The scanner authenticates to a constrained VLAN and cannot access unrelated services.
Explanation
Correct Answer
B:Replacing legacy equipment enables stronger WLAN protections. The revised requirement is: New scanner hardware supports modern WPA3-Enterprise controls. The appropriate action is: Migrate devices to stronger supported authentication with staged validation.
Incorrect Answers
A:Unencrypted production WLAN traffic creates avoidable exposure. It remains inappropriate in the revised context.
C:This is the original control. Security must balance device compatibility and risk with strong individual authentication. It does not directly satisfy the revised requirement: New scanner hardware supports modern WPA3-Enterprise controls.
D:The scanner authenticates to a constrained VLAN and cannot access unrelated services. The current requirement is: New scanner hardware supports modern WPA3-Enterprise controls.
Question 313
A six-floor office has one main equipment room and intermediate closets for each floor's access cabling. Which action MOST directly meets the stated networking requirement?
- Design a suitable MDF backbone with IDF distribution and documented fiber or copper runs.
- Calculate power budgets and use properly rated circuits and PDUs.
- Run every endpoint cable unlabelled through the lobby to a consumer switch.
- Add correctly sized cooling and thermal monitoring to that IDF.
Explanation
Correct Answer
A:Hierarchical wiring closets organize building backbone and access terminations. This specifically resolves: A six-floor office has one main equipment room and intermediate closets for each floor's access cabling.
Incorrect Answers
B:This addresses another problem in objective 2.4: A network closet's rack PDUs exceed safe electrical loading during a proposed server expansion.
C:Unstructured cabling complicates fault isolation and may violate length limits. The suggested approach is: Run every endpoint cable unlabelled through the lobby to a consumer switch.
D:This action responds to a later condition: One floor's closet cannot maintain acceptable environmental temperature. Physical distribution requires environmental conditions suitable for active equipment.
Question 314
A six-floor office has one main equipment room and intermediate closets for each floor's access cabling. A colleague instead suggests: Run every endpoint cable unlabelled through the lobby to a consumer switch. Which finding MOST specifically explains why that suggestion is unsuitable?
- Physical distribution requires environmental conditions suitable for active equipment.
- Hierarchical wiring closets organize building backbone and access terminations.
- Unstructured cabling complicates fault isolation and may violate length limits.
- Shared branch circuits and PDUs still impose aggregate current limits.
Explanation
Correct Answer
C:Unstructured cabling complicates fault isolation and may violate length limits. This flaw directly concerns the proposed action: Run every endpoint cable unlabelled through the lobby to a consumer switch.
Incorrect Answers
A:This rationale belongs to a later changed condition: One floor's closet cannot maintain acceptable environmental temperature.
B:This explains why the recommended control works: Design a suitable MDF backbone with IDF distribution and documented fiber or copper runs.
D:This flaw concerns a different case in objective 2.4: A network closet's rack PDUs exceed safe electrical loading during a proposed server expansion. The current rejected proposal is: Run every endpoint cable unlabelled through the lobby to a consumer switch.
Question 315
A six-floor office has one main equipment room and intermediate closets for each floor's access cabling. After applying the solution 'Design a suitable MDF backbone with IDF distribution and documented fiber or copper runs.', which observation MOST directly proves that the requirement was met?
- Measured load stays within rated capacity with planned headroom.
- Cable maps and rack diagrams match tested patch-panel runs to floor ports.
- A controlled power-loss test maintains service for the target interval.
- Approval is recorded for 'Design a suitable MDF backbone with IDF distribution and documented fiber or copper runs.' but no operational validation is performed.
Explanation
Correct Answer
B:Cable maps and rack diagrams match tested patch-panel runs to floor ports. It tests the intended outcome because hierarchical wiring closets organize building backbone and access terminations.
Incorrect Answers
A:This observation is for a different condition: A network closet's rack PDUs exceed safe electrical loading during a proposed server expansion. It does not directly test the target outcome: A six-floor office has one main equipment room and intermediate closets for each floor's access cabling.
C:This test addresses a separate problem: A distribution switch needs enough battery runtime to keep management access alive through brief power interruptions.
D:The missing direct test is: Cable maps and rack diagrams match tested patch-panel runs to floor ports.
Question 316
The original case was: A six-floor office has one main equipment room and intermediate closets for each floor's access cabling. The requirement then changes: One floor's closet cannot maintain acceptable environmental temperature. Which revised action BEST meets this new condition?
- Run every endpoint cable unlabelled through the lobby to a consumer switch.
- Cable maps and rack diagrams match tested patch-panel runs to floor ports.
- Add correctly sized cooling and thermal monitoring to that IDF.
- Design a suitable MDF backbone with IDF distribution and documented fiber or copper runs.
Explanation
Correct Answer
C:Physical distribution requires environmental conditions suitable for active equipment. The revised requirement is: One floor's closet cannot maintain acceptable environmental temperature. The appropriate action is: Add correctly sized cooling and thermal monitoring to that IDF.
Incorrect Answers
A:Unstructured cabling complicates fault isolation and may violate length limits. It remains inappropriate in the revised context.
B:Cable maps and rack diagrams match tested patch-panel runs to floor ports. The current requirement is: One floor's closet cannot maintain acceptable environmental temperature.
D:This is the original control. Hierarchical wiring closets organize building backbone and access terminations. It does not directly satisfy the revised requirement: One floor's closet cannot maintain acceptable environmental temperature.
Question 317
New rack switches draw air from front to rear but are installed in a reversed hot/cold aisle pattern. Which action MOST directly meets the stated networking requirement?
- Match equipment airflow orientation to the rack's cold and hot aisle design.
- Deploy a UPS sized for device load and required runtime.
- Install all network equipment with blocked intake vents to hide cables.
- Add monitored environmental controls for humidity and corrosion risk.
Explanation
Correct Answer
A:Correct airflow reduces recirculation and thermal failures. This specifically resolves: New rack switches draw air from front to rear but are installed in a reversed hot/cold aisle pattern.
Incorrect Answers
B:This addresses another problem in objective 2.4: A distribution switch needs enough battery runtime to keep management access alive through brief power interruptions.
C:Blocked intake raises device temperatures and jeopardizes reliability. The suggested approach is: Install all network equipment with blocked intake vents to hide cables.
D:This action responds to a later condition: The equipment room moves to a higher-humidity coastal site. Moisture and corrosion constraints require facility-level mitigation.
Question 318
New rack switches draw air from front to rear but are installed in a reversed hot/cold aisle pattern. A colleague instead suggests: Install all network equipment with blocked intake vents to hide cables. Which finding MOST specifically explains why that suggestion is unsuitable?
- Blocked intake raises device temperatures and jeopardizes reliability.
- Passive cabling hardware provides no backup electricity.
- Moisture and corrosion constraints require facility-level mitigation.
- Correct airflow reduces recirculation and thermal failures.
Explanation
Correct Answer
A:Blocked intake raises device temperatures and jeopardizes reliability. This flaw directly concerns the proposed action: Install all network equipment with blocked intake vents to hide cables.
Incorrect Answers
B:This flaw concerns a different case in objective 2.4: A distribution switch needs enough battery runtime to keep management access alive through brief power interruptions. The current rejected proposal is: Install all network equipment with blocked intake vents to hide cables.
C:This rationale belongs to a later changed condition: The equipment room moves to a higher-humidity coastal site.
D:This explains why the recommended control works: Match equipment airflow orientation to the rack's cold and hot aisle design.
Question 319
New rack switches draw air from front to rear but are installed in a reversed hot/cold aisle pattern. After applying the solution 'Match equipment airflow orientation to the rack's cold and hot aisle design.', which observation MOST directly proves that the requirement was met?
- Intake and exhaust temperature trends stabilize within vendor limits.
- A controlled power-loss test maintains service for the target interval.
- Approval is recorded for 'Match equipment airflow orientation to the rack's cold and hot aisle design.' but no operational validation is performed.
- Physical checks reconcile sampled port labels with the cable map.
Explanation
Correct Answer
A:Intake and exhaust temperature trends stabilize within vendor limits. It tests the intended outcome because correct airflow reduces recirculation and thermal failures.
Incorrect Answers
B:This observation is for a different condition: A distribution switch needs enough battery runtime to keep management access alive through brief power interruptions. It does not directly test the target outcome: New rack switches draw air from front to rear but are installed in a reversed hot/cold aisle pattern.
C:Approval alone does not demonstrate operating effectiveness. The missing direct test is: Intake and exhaust temperature trends stabilize within vendor limits.
D:This test addresses a separate problem: Technicians frequently unplug the wrong patch cables because an equipment rack has no port maps.
Question 320
The original case was: New rack switches draw air from front to rear but are installed in a reversed hot/cold aisle pattern. The requirement then changes: The equipment room moves to a higher-humidity coastal site. Which revised action BEST meets this new condition?
- Add monitored environmental controls for humidity and corrosion risk.
- Intake and exhaust temperature trends stabilize within vendor limits.
- Match equipment airflow orientation to the rack's cold and hot aisle design.
- Install all network equipment with blocked intake vents to hide cables.
Explanation
Correct Answer
A:Moisture and corrosion constraints require facility-level mitigation. The revised requirement is: The equipment room moves to a higher-humidity coastal site. The appropriate action is: Add monitored environmental controls for humidity and corrosion risk.
Incorrect Answers
B:Intake and exhaust temperature trends stabilize within vendor limits. The current requirement is: The equipment room moves to a higher-humidity coastal site.
C:This is the original control. Correct airflow reduces recirculation and thermal failures. It does not directly satisfy the revised requirement: The equipment room moves to a higher-humidity coastal site.
D:Blocked intake raises device temperatures and jeopardizes reliability. It remains inappropriate in the revised context.