Cisco 300-610 Practice Test 70
Question 690
At a multi-device API-based provisioning project, after correction, the team wants to prevent recurrence of: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. The team needs a defensible design decision rather than a vendor feature checklist. Which continuing design control best prevents the same problem from recurring?
- Enforce VNI and route-target collision prevention in controller templates.
- Include post-deployment fabric audits in controller workflows.
- Require management bootstrap and version support checks for new leaves.
- Require path-redundancy review before controller-scheduled maintenance.
Explanation
Correct Answer
A:The most relevant ongoing safeguard is: Enforce VNI and route-target collision prevention in controller templates. The risk it addresses is: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. This check is tied to the technical principle: Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements. The immediate correction remains: Parameterize and validate tenant network identifiers with collision checks before generating VXLAN intent. Periodically validate the safeguard through two different observations. Compare generated VNI/VRF/RT assignments for distinct customers Run allowed and denied synthetic inter-tenant reachability tests after deployment. The continuing acceptance target is: Distinct tenants remain isolated while their approved segments have correct overlay reachability.
Incorrect Answers
B:This is a continuing control for nexus dashboard fabric controller fabric intent; its underlying principle is: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. The recurring risk here is different: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A Nexus Dashboard deployment automates fabric interface objects but an engineer assumes every created object has already been pushed and operationalized on physical devices. The intended long-term acceptance condition remains: Distinct tenants remain isolated while their approved segments have correct overlay reachability.
C:This is a continuing control for nexus dashboard discovered device prerequisites; its underlying principle is: Controller onboarding depends on device credentials, routing, supported software and telemetry connectivity in addition to inventory presence. The recurring risk here is different: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A fabric onboarding script adds unreachable leaf switches to Nexus Dashboard and treats a discovered inventory entry as successful management onboarding. The intended long-term acceptance condition remains: Distinct tenants remain isolated while their approved segments have correct overlay reachability.
D:This is a continuing control for nexus dashboard device upgrade orchestration; its underlying principle is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. The recurring risk here is different: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The intended long-term acceptance condition remains: Distinct tenants remain isolated while their approved segments have correct overlay reachability.
Question 691
At a multi-device API-based provisioning project, a design review reports the following issue: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The maintenance plan must not disrupt unrelated tenants. Which design correction most directly addresses this specific failure or requirement?
- Parameterize and validate tenant network identifiers with collision checks before generating VXLAN intent.
- Review deployment status and verify effective fabric configuration after pushing validated intent.
- Stage upgrades using supported rolling workflows, compatibility checks and service drains rather than parallel all-device reboot.
- Validate bootstrap reachability, RBAC and supported device configuration before enrolling the leaf into management.
Explanation
Correct Answer
C:The relevant failure is: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The technical distinction is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. The targeted correction is: Stage upgrades using supported rolling workflows, compatibility checks and service drains rather than parallel all-device reboot. Before changing the design, check two independent observations. Inspect planned device maintenance order and peer topology Test a representative leaf drain with application packet measurements. Accept the change only if: The fabric remains within service availability targets throughout the authorized upgrade.
Incorrect Answers
A:This action targets nexus dashboard vxlan intent segmentation, where the mechanism is: Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements. That is a separate condition from the problem in this question: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. Even a successful repair of the alternative would not establish the required result: The fabric remains within service availability targets throughout the authorized upgrade. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
B:This action targets nexus dashboard fabric controller fabric intent, where the mechanism is: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. That is a separate condition from the problem in this question: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. Even a successful repair of the alternative would not establish the required result: The fabric remains within service availability targets throughout the authorized upgrade. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
D:This action targets nexus dashboard discovered device prerequisites, where the mechanism is: Controller onboarding depends on device credentials, routing, supported software and telemetry connectivity in addition to inventory presence. That is a separate condition from the problem in this question: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. Even a successful repair of the alternative would not establish the required result: The fabric remains within service availability targets throughout the authorized upgrade. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
Question 692
At an Intersight service-profile rollout, two engineers propose competing diagnoses for this condition: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. Acceptance requires evidence from the running system, not just the saved design. Which pair of observations most directly tests the proposed diagnosis before a change?
- Map controller nodes to distinct hosts, racks and network paths; simulate loss of one eligible management node while checking dashboard and automation services.
- Inspect fabric-controller pending changes and job completion; compare live switch policy and interface state to the expected fabric intent.
- Inspect planned device maintenance order and peer topology; test a representative leaf drain with application packet measurements.
- Compare generated VNI/VRF/RT assignments for distinct customers; run allowed and denied synthetic inter-tenant reachability tests after deployment.
Explanation
Correct Answer
C:The first observation is: Inspect planned device maintenance order and peer topology The independent second observation is: Test a representative leaf drain with application packet measurements. Together they test the proposed diagnosis of this incident: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The underlying technical principle is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. If those checks confirm it, the appropriate next action is: Stage upgrades using supported rolling workflows, compatibility checks and service drains rather than parallel all-device reboot. The expected measurable result is: The fabric remains within service availability targets throughout the authorized upgrade.
Incorrect Answers
A:These observations investigate nexus dashboard controller redundancy; they would be useful if the symptoms were: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. That alternative rests on the principle: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy. The question instead asks for evidence about: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The discriminating observations here are: Inspect planned device maintenance order and peer topology Test a representative leaf drain with application packet measurements.
B:These observations investigate nexus dashboard fabric controller fabric intent; they would be useful if the symptoms were: A Nexus Dashboard deployment automates fabric interface objects but an engineer assumes every created object has already been pushed and operationalized on physical devices. That alternative rests on the principle: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. The question instead asks for evidence about: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The discriminating observations here are: Inspect planned device maintenance order and peer topology Test a representative leaf drain with application packet measurements.
D:These observations investigate nexus dashboard vxlan intent segmentation; they would be useful if the symptoms were: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. That alternative rests on the principle: Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements. The question instead asks for evidence about: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The discriminating observations here are: Inspect planned device maintenance order and peer topology Test a representative leaf drain with application packet measurements.
Question 693
At an automation governance team, the design group challenges an assumption behind this issue: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. One component outage must remain inside the agreed availability budget. Which engineering principle best explains the observed behavior?
- Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks.
- Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements.
- Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy.
- Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains.
Explanation
Correct Answer
D:The controlling technical principle is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. This matters because the reported design failure is: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The first diagnostic check is: Inspect planned device maintenance order and peer topology The independent check is: Test a representative leaf drain with application packet measurements. These facts support the targeted intervention: Stage upgrades using supported rolling workflows, compatibility checks and service drains rather than parallel all-device reboot. Confirm that the resulting design meets this condition: The fabric remains within service availability targets throughout the authorized upgrade.
Incorrect Answers
A:The offered principle describes nexus dashboard fabric controller fabric intent: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. That is useful for a distinct incident, such as: A Nexus Dashboard deployment automates fabric interface objects but an engineer assumes every created object has already been pushed and operationalized on physical devices. It does not account for the reported failure: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The governing principle in this situation is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains.
B:The offered principle describes nexus dashboard vxlan intent segmentation: Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements. That is useful for a distinct incident, such as: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. It does not account for the reported failure: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The governing principle in this situation is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains.
C:The offered principle describes nexus dashboard controller redundancy: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy. That is useful for a distinct incident, such as: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. It does not account for the reported failure: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The governing principle in this situation is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains.
Question 694
At a network orchestration engineering team, a change has been proposed for the following condition: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The architect must preserve the intended failure domains. Which measured result most directly proves the original requirement is satisfied?
- The management plane meets its stated availability target without treating backups as active HA.
- The controller can accurately manage and observe every intended fabric device.
- The fabric remains within service availability targets throughout the authorized upgrade.
- Distinct tenants remain isolated while their approved segments have correct overlay reachability.
Explanation
Correct Answer
C:The relevant measurable success criterion is: The fabric remains within service availability targets throughout the authorized upgrade. It addresses the original reported defect: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. A saved design or configuration command alone does not establish that outcome. Observe the affected system in two independent ways: Inspect planned device maintenance order and peer topology Test a representative leaf drain with application packet measurements. The correction being evaluated is: Stage upgrades using supported rolling workflows, compatibility checks and service drains rather than parallel all-device reboot. The underlying reason that correction matters is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains.
Incorrect Answers
A:This metric would help validate a correction to nexus dashboard controller redundancy, rather than the original reported issue. The other issue is: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. Here the defect to be resolved is: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The expected measurable outcome for the actual incident is: The fabric remains within service availability targets throughout the authorized upgrade. A positive result for the other service would not prove this requirement is met.
B:This metric would help validate a correction to nexus dashboard discovered device prerequisites, rather than the original reported issue. The other issue is: A fabric onboarding script adds unreachable leaf switches to Nexus Dashboard and treats a discovered inventory entry as successful management onboarding. Here the defect to be resolved is: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The expected measurable outcome for the actual incident is: The fabric remains within service availability targets throughout the authorized upgrade. A positive result for the other service would not prove this requirement is met.
D:This metric would help validate a correction to nexus dashboard vxlan intent segmentation, rather than the original reported issue. The other issue is: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. Here the defect to be resolved is: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The expected measurable outcome for the actual incident is: The fabric remains within service availability targets throughout the authorized upgrade. A positive result for the other service would not prove this requirement is met.
Question 695
At a Nexus Dashboard fabric deployment, a post-incident design review focuses on preventing: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The team needs a defensible design decision rather than a vendor feature checklist. Which continuing design control best prevents the same problem from recurring?
- Test controller restores and node-loss recovery as separate procedures.
- Require path-redundancy review before controller-scheduled maintenance.
- Enforce VNI and route-target collision prevention in controller templates.
- Include post-deployment fabric audits in controller workflows.
Explanation
Correct Answer
B:The most relevant ongoing safeguard is: Require path-redundancy review before controller-scheduled maintenance. The risk it addresses is: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. This check is tied to the technical principle: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. The immediate correction remains: Stage upgrades using supported rolling workflows, compatibility checks and service drains rather than parallel all-device reboot. Periodically validate the safeguard through two different observations. Inspect planned device maintenance order and peer topology Test a representative leaf drain with application packet measurements. The continuing acceptance target is: The fabric remains within service availability targets throughout the authorized upgrade.
Incorrect Answers
A:This is a continuing control for nexus dashboard controller redundancy; its underlying principle is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy. The recurring risk here is different: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The intended long-term acceptance condition remains: The fabric remains within service availability targets throughout the authorized upgrade.
C:This is a continuing control for nexus dashboard vxlan intent segmentation; its underlying principle is: Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements. The recurring risk here is different: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. The intended long-term acceptance condition remains: The fabric remains within service availability targets throughout the authorized upgrade.
D:This is a continuing control for nexus dashboard fabric controller fabric intent; its underlying principle is: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. The recurring risk here is different: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A Nexus Dashboard deployment automates fabric interface objects but an engineer assumes every created object has already been pushed and operationalized on physical devices. The intended long-term acceptance condition remains: The fabric remains within service availability targets throughout the authorized upgrade.
Question 696
At a Nexus Dashboard fabric deployment, during a controlled design review, the team discovers: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The maintenance plan must not disrupt unrelated tenants. Which design correction most directly addresses this specific failure or requirement?
- Review deployment status and verify effective fabric configuration after pushing validated intent.
- Validate bootstrap reachability, RBAC and supported device configuration before enrolling the leaf into management.
- Choose supported multi-node controller placement and independent recovery arrangements according to management RTO.
- Stage upgrades using supported rolling workflows, compatibility checks and service drains rather than parallel all-device reboot.
Explanation
Correct Answer
C:The relevant failure is: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The technical distinction is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy. The targeted correction is: Choose supported multi-node controller placement and independent recovery arrangements according to management RTO. Before changing the design, check two independent observations. Map controller nodes to distinct hosts, racks and network paths Simulate loss of one eligible management node while checking dashboard and automation services. Accept the change only if: The management plane meets its stated availability target without treating backups as active HA.
Incorrect Answers
A:This action targets nexus dashboard fabric controller fabric intent, where the mechanism is: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. That is a separate condition from the problem in this question: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. Even a successful repair of the alternative would not establish the required result: The management plane meets its stated availability target without treating backups as active HA. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
B:This action targets nexus dashboard discovered device prerequisites, where the mechanism is: Controller onboarding depends on device credentials, routing, supported software and telemetry connectivity in addition to inventory presence. That is a separate condition from the problem in this question: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. Even a successful repair of the alternative would not establish the required result: The management plane meets its stated availability target without treating backups as active HA. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
D:This action targets nexus dashboard device upgrade orchestration, where the mechanism is: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. That is a separate condition from the problem in this question: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. Even a successful repair of the alternative would not establish the required result: The management plane meets its stated availability target without treating backups as active HA. The applicable design change must address the diagnosed mechanism of the stated case, not the neighboring design problem.
Question 697
At a multi-device API-based provisioning project, before changing the fabric, the team observes: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. Acceptance requires evidence from the running system, not just the saved design. Which pair of observations most directly tests the proposed diagnosis before a change?
- Inspect fabric-controller pending changes and job completion; compare live switch policy and interface state to the expected fabric intent.
- Inspect planned device maintenance order and peer topology; test a representative leaf drain with application packet measurements.
- Test management-plane connectivity and AAA from controller nodes; inspect device discovery, credential and telemetry status after enrollment.
- Map controller nodes to distinct hosts, racks and network paths; simulate loss of one eligible management node while checking dashboard and automation services.
Explanation
Correct Answer
D:The first observation is: Map controller nodes to distinct hosts, racks and network paths The independent second observation is: Simulate loss of one eligible management node while checking dashboard and automation services. Together they test the proposed diagnosis of this incident: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The underlying technical principle is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy. If those checks confirm it, the appropriate next action is: Choose supported multi-node controller placement and independent recovery arrangements according to management RTO. The expected measurable result is: The management plane meets its stated availability target without treating backups as active HA.
Incorrect Answers
A:These observations investigate nexus dashboard fabric controller fabric intent; they would be useful if the symptoms were: A Nexus Dashboard deployment automates fabric interface objects but an engineer assumes every created object has already been pushed and operationalized on physical devices. That alternative rests on the principle: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. The question instead asks for evidence about: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The discriminating observations here are: Map controller nodes to distinct hosts, racks and network paths Simulate loss of one eligible management node while checking dashboard and automation services.
B:These observations investigate nexus dashboard device upgrade orchestration; they would be useful if the symptoms were: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. That alternative rests on the principle: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. The question instead asks for evidence about: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The discriminating observations here are: Map controller nodes to distinct hosts, racks and network paths Simulate loss of one eligible management node while checking dashboard and automation services.
C:These observations investigate nexus dashboard discovered device prerequisites; they would be useful if the symptoms were: A fabric onboarding script adds unreachable leaf switches to Nexus Dashboard and treats a discovered inventory entry as successful management onboarding. That alternative rests on the principle: Controller onboarding depends on device credentials, routing, supported software and telemetry connectivity in addition to inventory presence. The question instead asks for evidence about: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The discriminating observations here are: Map controller nodes to distinct hosts, racks and network paths Simulate loss of one eligible management node while checking dashboard and automation services.
Question 698
At an Intersight service-profile rollout, the data-center team needs to explain this behavior: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. One component outage must remain inside the agreed availability budget. Which engineering principle best explains the observed behavior?
- Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements.
- Controller onboarding depends on device credentials, routing, supported software and telemetry connectivity in addition to inventory presence.
- Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy.
- Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains.
Explanation
Correct Answer
C:The controlling technical principle is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy. This matters because the reported design failure is: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The first diagnostic check is: Map controller nodes to distinct hosts, racks and network paths The independent check is: Simulate loss of one eligible management node while checking dashboard and automation services. These facts support the targeted intervention: Choose supported multi-node controller placement and independent recovery arrangements according to management RTO. Confirm that the resulting design meets this condition: The management plane meets its stated availability target without treating backups as active HA.
Incorrect Answers
A:The offered principle describes nexus dashboard vxlan intent segmentation: Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements. That is useful for a distinct incident, such as: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. It does not account for the reported failure: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The governing principle in this situation is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy.
B:The offered principle describes nexus dashboard discovered device prerequisites: Controller onboarding depends on device credentials, routing, supported software and telemetry connectivity in addition to inventory presence. That is useful for a distinct incident, such as: A fabric onboarding script adds unreachable leaf switches to Nexus Dashboard and treats a discovered inventory entry as successful management onboarding. It does not account for the reported failure: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The governing principle in this situation is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy.
D:The offered principle describes nexus dashboard device upgrade orchestration: Fabric automation must sequence maintenance across redundant devices and understand their shared failure domains. That is useful for a distinct incident, such as: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. It does not account for the reported failure: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The governing principle in this situation is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy.
Question 699
At an automation governance team, the team completed an authorized repair for: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The architect must preserve the intended failure domains. Which measured result most directly proves the original requirement is satisfied?
- The fabric remains within service availability targets throughout the authorized upgrade.
- The controller can accurately manage and observe every intended fabric device.
- The deployed fabric matches the reviewed intent, not merely the saved controller model.
- The management plane meets its stated availability target without treating backups as active HA.
Explanation
Correct Answer
D:The relevant measurable success criterion is: The management plane meets its stated availability target without treating backups as active HA. It addresses the original reported defect: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. A saved design or configuration command alone does not establish that outcome. Observe the affected system in two independent ways: Map controller nodes to distinct hosts, racks and network paths Simulate loss of one eligible management node while checking dashboard and automation services. The correction being evaluated is: Choose supported multi-node controller placement and independent recovery arrangements according to management RTO. The underlying reason that correction matters is: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy.
Incorrect Answers
A:This metric would help validate a correction to nexus dashboard device upgrade orchestration, rather than the original reported issue. The other issue is: An automated Nexus Dashboard upgrade job reboots every fabric switch simultaneously despite an application requiring continuous paths. Here the defect to be resolved is: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The expected measurable outcome for the actual incident is: The management plane meets its stated availability target without treating backups as active HA. A positive result for the other service would not prove this requirement is met.
B:This metric would help validate a correction to nexus dashboard discovered device prerequisites, rather than the original reported issue. The other issue is: A fabric onboarding script adds unreachable leaf switches to Nexus Dashboard and treats a discovered inventory entry as successful management onboarding. Here the defect to be resolved is: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The expected measurable outcome for the actual incident is: The management plane meets its stated availability target without treating backups as active HA. A positive result for the other service would not prove this requirement is met.
C:This metric would help validate a correction to nexus dashboard fabric controller fabric intent, rather than the original reported issue. The other issue is: A Nexus Dashboard deployment automates fabric interface objects but an engineer assumes every created object has already been pushed and operationalized on physical devices. Here the defect to be resolved is: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The expected measurable outcome for the actual incident is: The management plane meets its stated availability target without treating backups as active HA. A positive result for the other service would not prove this requirement is met.
Question 700
At a network orchestration engineering team, the architecture standards group considers the recurring risk: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The team needs a defensible design decision rather than a vendor feature checklist. Which continuing design control best prevents the same problem from recurring?
- Enforce VNI and route-target collision prevention in controller templates.
- Test controller restores and node-loss recovery as separate procedures.
- Include post-deployment fabric audits in controller workflows.
- Require management bootstrap and version support checks for new leaves.
Explanation
Correct Answer
B:The most relevant ongoing safeguard is: Test controller restores and node-loss recovery as separate procedures. The risk it addresses is: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. This check is tied to the technical principle: Backups preserve recoverable state but do not replace active clustered control-plane or node failure-domain redundancy. The immediate correction remains: Choose supported multi-node controller placement and independent recovery arrangements according to management RTO. Periodically validate the safeguard through two different observations. Map controller nodes to distinct hosts, racks and network paths Simulate loss of one eligible management node while checking dashboard and automation services. The continuing acceptance target is: The management plane meets its stated availability target without treating backups as active HA.
Incorrect Answers
A:This is a continuing control for nexus dashboard vxlan intent segmentation; its underlying principle is: Automated fabric overlays require tenant-specific VLAN/VNI/VRF and RT mapping; template reuse does not remove isolation requirements. The recurring risk here is different: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A controller template creates a single tenant VRF and VNI for every customer because its automated default is reused without input validation. The intended long-term acceptance condition remains: The management plane meets its stated availability target without treating backups as active HA.
C:This is a continuing control for nexus dashboard fabric controller fabric intent; its underlying principle is: Fabric-controller desired intent, deployment tasks and operational switch state are distinct stages requiring explicit checks. The recurring risk here is different: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A Nexus Dashboard deployment automates fabric interface objects but an engineer assumes every created object has already been pushed and operationalized on physical devices. The intended long-term acceptance condition remains: The management plane meets its stated availability target without treating backups as active HA.
D:This is a continuing control for nexus dashboard discovered device prerequisites; its underlying principle is: Controller onboarding depends on device credentials, routing, supported software and telemetry connectivity in addition to inventory presence. The recurring risk here is different: A data-center design uses one Nexus Dashboard node and assumes that backing up its configuration provides management service high availability. The appropriate ongoing control must prevent recurrence of that particular failure, not just the separate issue of: A fabric onboarding script adds unreachable leaf switches to Nexus Dashboard and treats a discovered inventory entry as successful management onboarding. The intended long-term acceptance condition remains: The management plane meets its stated availability target without treating backups as active HA.