Cisco 300-420 Practice Test 79
Question 780
A design calls for streaming on-change telemetry over authenticated gRPC with supported gNMI paths. The observed fault is: Assuming every sensor supports ON_CHANGE without device capability checks can cause missing events or rejected subscriptions. Which recovery is BEST once this fault is identified?
- The controlled recovery is to use a network packet capture as a replacement for checking subscription capability and returned updates.
- The controlled recovery is to validate model and mode support and verify an interface event reaches the receiver within required bounds.
- The controlled recovery is to treat a periodic ten-minute subscription as guaranteed immediate notification for every state change.
- The controlled recovery is to assume an unauthenticated open TCP socket is sufficient for secure production gNMI transport.
Explanation
Correct Answer
B:This corrects the described failure and provides a verifiable outcome. gNMI commonly uses gRPC transport and supports telemetry subscription modes including SAMPLE and ON_CHANGE where implemented.
Incorrect Answers
A:Use a network packet capture as a replacement for checking subscription capability and returned updates. Assuming every sensor supports ON_CHANGE without device capability checks can cause missing events or rejected subscriptions. Use the controlled remediation: validate model and mode support and verify an interface event reaches the receiver within required bounds.
C:Treat a periodic ten-minute subscription as guaranteed immediate notification for every state change. Assuming every sensor supports ON_CHANGE without device capability checks can cause missing events or rejected subscriptions. Use the controlled remediation: validate model and mode support and verify an interface event reaches the receiver within required bounds.
D:Assume an unauthenticated open TCP socket is sufficient for secure production gNMI transport. Assuming every sensor supports ON_CHANGE without device capability checks can cause missing events or rejected subscriptions. Use the controlled remediation: validate model and mode support and verify an interface event reaches the receiver within required bounds.
Question 781
An enterprise migrates workloads to a public cloud but all user sites still hairpin through one headquarters Internet gateway. Which enterprise design procedure best meets this requirement?
- Design cloud on-ramp paths using supported private connectivity, cloud gateway routing and failover policy.
- Assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration.
- Carry all cloud traffic through one headquarters router while claiming independent regional resilience.
- Use a public SaaS domain name as proof a private cloud interconnect is healthy.
Explanation
Correct Answer
A:Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. This is the specific corrective action for Hybrid cloud on-ramp and direct-connect failure design.
Incorrect Answers
B:A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. This change targets the wrong mechanism for Hybrid cloud on-ramp and direct-connect failure design.
C:Carry all cloud traffic through one headquarters router while claiming independent regional resilience. Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Instead inspect cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
D:A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. In this case, an enterprise migrates workloads to a public cloud but all user sites still hairpin through one headquarters Internet gateway.
Question 782
An enterprise migrates workloads to a public cloud but all user sites still hairpin through one headquarters Internet gateway. Which evidence best distinguishes the intended state from a superficial indicator?
- One successful ping to an unrelated test host without a path or failover test.
- Cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
- A hostname inventory without effective configuration or operational measurements.
- An old network diagram with no current route, policy, or redundancy state.
Explanation
Correct Answer
B:Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. This evidence observes the actual hybrid cloud on-ramp and direct-connect failure design mechanism and its result.
Incorrect Answers
A:This observation alone cannot establish hybrid cloud on-ramp and direct-connect failure design. Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy.
C:This observation alone cannot establish hybrid cloud on-ramp and direct-connect failure design. The decisive evidence instead includes cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
D:This observation alone cannot establish hybrid cloud on-ramp and direct-connect failure design.
Question 783
An enterprise migrates workloads to a public cloud but all user sites still hairpin through one headquarters Internet gateway. Which underlying principle explains the correct decision?
- Encryption and segmentation are identical mechanisms and can replace each other.
- A longer IP prefix is always less specific than the default route.
- Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy.
- An operational up state alone proves every security and design objective is met.
Explanation
Correct Answer
C:This is why the appropriate action is design cloud on-ramp paths using supported private connectivity, cloud gateway routing and failover policy. Confirm it with cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
Incorrect Answers
A:Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for hybrid cloud on-ramp and direct-connect failure design. The relevant rule is cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Verify using cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
B:A longer IP prefix is always less specific than the default route. This is an incorrect generalization for hybrid cloud on-ramp and direct-connect failure design. The relevant rule is cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Verify using cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
D:An operational up state alone proves every security and design objective is met. This is an incorrect generalization for hybrid cloud on-ramp and direct-connect failure design. The relevant rule is cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Verify using cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
Question 784
An enterprise migrates workloads to a public cloud but all user sites still hairpin through one headquarters Internet gateway. Suppose the operator instead makes this incorrect change: Assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration. What is the most material consequence of that mistake?
- A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure.
- Collecting telemetry originally caused the missing route or service outage.
- A correct change-control review makes all WAN carriers fail simultaneously.
- The only issue is an inaccurate hostname while traffic paths are unaffected.
Explanation
Correct Answer
A:This explains why the proposed shortcut does not solve hybrid cloud on-ramp and direct-connect failure design. Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy.
Incorrect Answers
B:Collecting telemetry originally caused the missing route or service outage. The actual failure is a single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Check cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
C:A correct change-control review makes all WAN carriers fail simultaneously. The actual failure is a single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Check cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
D:The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is a single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Check cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
Question 785
An enterprise migrates workloads to a public cloud but all user sites still hairpin through one headquarters Internet gateway. The observed fault is: A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Which controlled remediation should be used?
- Carry all cloud traffic through one headquarters router while claiming independent regional resilience.
- Add diverse paths and validate policy routing and secure failover for cloud destinations.
- Use a public SaaS domain name as proof a private cloud interconnect is healthy.
- Assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration.
Explanation
Correct Answer
B:Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. This corrects the described failure and provides a verifiable outcome.
Incorrect Answers
A:Carry all cloud traffic through one headquarters router while claiming independent regional resilience. A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Use the controlled remediation: add diverse paths and validate policy routing and secure failover for cloud destinations.
C:That option would use a public SaaS domain name as proof a private cloud interconnect is healthy, but it addresses a different concern. Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy.
D:That option would assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration, but it addresses a different concern. Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy.
Question 786
A financial firm wants private cloud interconnect while maintaining alternate encrypted Internet access during direct circuit failure. What is the most defensible configuration decision?
- For this enterprise design, the architect should carry all cloud traffic through one headquarters router while claiming independent regional resilience.
- For this enterprise design, the architect should use a public SaaS domain name as proof a private cloud interconnect is healthy.
- For this enterprise design, the architect should design cloud on-ramp paths using supported private connectivity, cloud gateway routing and failover policy.
- For this enterprise design, the architect should assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration.
Explanation
Correct Answer
C:Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Confirm the result using cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
Incorrect Answers
A:Carry all cloud traffic through one headquarters router while claiming independent regional resilience. Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Instead inspect cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
B:A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. In this case, a financial firm wants private cloud interconnect while maintaining alternate encrypted Internet access during direct circuit failure.
D:A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. The relevant action is design cloud on-ramp paths using supported private connectivity, cloud gateway routing and failover policy.
Question 787
A financial firm wants private cloud interconnect while maintaining alternate encrypted Internet access during direct circuit failure. Which evidence BEST confirms the actual technical behavior?
- Inspect the following evidence: cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
- Inspect the following evidence: a feature-license screenshot without the required design or acceptance tests.
- Inspect the following evidence: one successful ping to an unrelated test host without a path or failover test.
- Inspect the following evidence: a hostname inventory without effective configuration or operational measurements.
Explanation
Correct Answer
A:Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. The intended procedure is design cloud on-ramp paths using supported private connectivity, cloud gateway routing and failover policy.
Incorrect Answers
B:This observation alone cannot establish hybrid cloud on-ramp and direct-connect failure design. A feature-license screenshot without the required design or acceptance tests.
C:This observation alone cannot establish hybrid cloud on-ramp and direct-connect failure design. One successful ping to an unrelated test host without a path or failover test.
D:This observation alone cannot establish hybrid cloud on-ramp and direct-connect failure design. A hostname inventory without effective configuration or operational measurements.
Question 788
A financial firm wants private cloud interconnect while maintaining alternate encrypted Internet access during direct circuit failure. What networking or enterprise network design concept best explains this scenario?
- The relevant principle is that an operational up state alone proves every security and design objective is met.
- The relevant principle is that cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy.
- The relevant principle is that encryption and segmentation are identical mechanisms and can replace each other.
- The relevant principle is that cloud connectivity automatically removes any requirement for routing or policy.
Explanation
Correct Answer
B:This is why the appropriate action is design cloud on-ramp paths using supported private connectivity, cloud gateway routing and failover policy.
Incorrect Answers
A:An operational up state alone proves every security and design objective is met. This is an incorrect generalization for hybrid cloud on-ramp and direct-connect failure design. The relevant rule is cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Verify using cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
C:Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for hybrid cloud on-ramp and direct-connect failure design. The relevant rule is cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Verify using cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
D:Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for hybrid cloud on-ramp and direct-connect failure design. The relevant rule is cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Verify using cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
Question 789
A financial firm wants private cloud interconnect while maintaining alternate encrypted Internet access during direct circuit failure. Suppose the operator instead makes this incorrect change: Assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration. Which resulting fault should the reviewer identify?
- The resulting technical fault is that the only issue is an inaccurate hostname while traffic paths are unaffected.
- The resulting technical fault is that a healthy unrelated system proves the intended failure domain is protected.
- The resulting technical fault is that a correct change-control review makes all WAN carriers fail simultaneously.
- The resulting technical fault is that a single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure.
Explanation
Correct Answer
D:This explains why the proposed shortcut does not solve hybrid cloud on-ramp and direct-connect failure design. The right response is design cloud on-ramp paths using supported private connectivity, cloud gateway routing and failover policy.
Incorrect Answers
A:The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is a single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Check cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
B:A healthy unrelated system proves the intended failure domain is protected. The actual failure is a single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Check cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
C:A correct change-control review makes all WAN carriers fail simultaneously. The actual failure is a single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Check cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
Question 790
A financial firm wants private cloud interconnect while maintaining alternate encrypted Internet access during direct circuit failure. The observed fault is: A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. How should the issue be corrected and verified?
- The controlled recovery is to add diverse paths and validate policy routing and secure failover for cloud destinations.
- The controlled recovery is to use a public SaaS domain name as proof a private cloud interconnect is healthy.
- The controlled recovery is to assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration.
- The controlled recovery is to carry all cloud traffic through one headquarters router while claiming independent regional resilience.
Explanation
Correct Answer
A:Cloud direct connectivity and SD-WAN on-ramp designs must coordinate underlay capacity routing and failure-domain redundancy. Relevant evidence includes cloud interconnect circuits, gateway BGP peers, route propagation, RTT and backup tunnel behavior.
Incorrect Answers
B:Use a public SaaS domain name as proof a private cloud interconnect is healthy. A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Use the controlled remediation: add diverse paths and validate policy routing and secure failover for cloud destinations.
C:Assume cloud direct connection automatically establishes every enterprise VPN and route policy without configuration. A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Use the controlled remediation: add diverse paths and validate policy routing and secure failover for cloud destinations.
D:Carry all cloud traffic through one headquarters router while claiming independent regional resilience. A single private cloud circuit with no alternate path can make cloud apps unavailable during carrier failure. Use the controlled remediation: add diverse paths and validate policy routing and secure failover for cloud destinations.