cert
cert-1
cert-2

Pass Amazon AWS Certified Solutions Architect - Associate SAA-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
AWS Certified Solutions Architect - Associate SAA-C03 Exam - Verified By Experts
AWS Certified Solutions Architect - Associate SAA-C03 Premium Bundle
$29.98

AWS Certified Solutions Architect - Associate SAA-C03 Premium Bundle

$79.99
$109.97
  • Premium File 1063 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 368 Video Lectures
  • Study Guide 632 Pages
 
$109.97
$79.99
accept 217 downloads in last 7 days
block-screenshots
Purchase Amazon AWS Certified Solutions Architect - Associate SAA-C03 Exam Training Products Individually
Amazon AWS Certified Solutions Architect - Associate SAA-C03 Premium File
Premium File 1063 Q&A
$76.99$69.99
Amazon AWS Certified Solutions Architect - Associate SAA-C03 Video Training Course
Training Course 368 Lectures
$21.99 $19.99
Amazon AWS Certified Solutions Architect - Associate SAA-C03 PDF Study Guide
Study Guide 632 Pages
$21.99 $19.99
Amazon AWS Certified Solutions Architect - Associate SAA-C03 Practice Test 43

Question 420

A distribution's primary origin returns an HTTP code not configured for failover, so CloudFront never uses the secondary. What setting is missing?

  1. Configure a CloudFront origin group with primary and secondary origins for supported requests.
  2. Authorize CloudFront origin access to the backup bucket using the appropriate supported access control.
  3. Include the appropriate supported HTTP failure status in the origin-group failover criteria.
  4. CloudFront origin-group failover is limited to eligible idempotent request methods, not arbitrary POST replay.

Explanation

Correct Answer

C:

CloudFront origin-group routing responds to configured eligible error codes, not every application response. Return the target error and verify which origin handles the next eligible request.

Incorrect Answers

A:

Origin failover can route eligible requests to a secondary origin on configured origin failure responses. Include the appropriate supported HTTP failure status in the origin-group failover criteria. Return the target error and verify which origin handles the next eligible request.

B:

Each private S3 origin needs its own correct bucket access policy for distribution fetches. Include the appropriate supported HTTP failure status in the origin-group failover criteria. Return the target error and verify which origin handles the next eligible request.

D:

Automatic origin failover for mutations could duplicate side effects, so application-level resilience is necessary. Include the appropriate supported HTTP failure status in the origin-group failover criteria. Return the target error and verify which origin handles the next eligible request.

Question 421

A backup origin contains outdated objects after deployment; origin failover serves stale content. What else must be synchronized?

  1. Replicate approved static assets to an additional S3 bucket and configure a supported CloudFront origin failover strategy.
  2. Include the appropriate supported HTTP failure status in the origin-group failover criteria.
  3. Maintain equivalent object versions on both origin locations before failover.
  4. Configure a CloudFront origin group with primary and secondary origins for supported requests.

Explanation

Correct Answer

C:

Failover routing cannot make an unsynchronized secondary data source current. Update a test object and verify byte equality from both origins.

Incorrect Answers

A:

Redundant origins and consistent object copies reduce dependence on one regional endpoint. Maintain equivalent object versions on both origin locations before failover. Update a test object and verify byte equality from both origins.

B:

CloudFront origin-group routing responds to configured eligible error codes, not every application response. Maintain equivalent object versions on both origin locations before failover. Update a test object and verify byte equality from both origins.

D:

Origin failover can route eligible requests to a secondary origin on configured origin failure responses. Maintain equivalent object versions on both origin locations before failover. Update a test object and verify byte equality from both origins.

Question 422

An S3 static website must remain available even if one Region's bucket endpoint is unavailable. What layout fits?

  1. Configure a CloudFront origin group with primary and secondary origins for supported requests.
  2. Authorize CloudFront origin access to the backup bucket using the appropriate supported access control.
  3. Include the appropriate supported HTTP failure status in the origin-group failover criteria.
  4. Replicate approved static assets to an additional S3 bucket and configure a supported CloudFront origin failover strategy.

Explanation

Correct Answer

D:

Redundant origins and consistent object copies reduce dependence on one regional endpoint. Disable primary origin access and fetch an uncached object through the distribution.

Incorrect Answers

A:

Origin failover can route eligible requests to a secondary origin on configured origin failure responses. Replicate approved static assets to an additional S3 bucket and configure a supported CloudFront origin failover strategy. Disable primary origin access and fetch an uncached object through the distribution.

B:

Each private S3 origin needs its own correct bucket access policy for distribution fetches. Replicate approved static assets to an additional S3 bucket and configure a supported CloudFront origin failover strategy. Disable primary origin access and fetch an uncached object through the distribution.

C:

CloudFront origin-group routing responds to configured eligible error codes, not every application response. Replicate approved static assets to an additional S3 bucket and configure a supported CloudFront origin failover strategy. Disable primary origin access and fetch an uncached object through the distribution.

Question 423

CloudFront fails to retrieve private objects from its backup S3 origin. What security configuration is likely missing?

  1. Include the appropriate supported HTTP failure status in the origin-group failover criteria.
  2. Authorize CloudFront origin access to the backup bucket using the appropriate supported access control.
  3. CloudFront origin-group failover is limited to eligible idempotent request methods, not arbitrary POST replay.
  4. Replicate approved static assets to an additional S3 bucket and configure a supported CloudFront origin failover strategy.

Explanation

Correct Answer

B:

Each private S3 origin needs its own correct bucket access policy for distribution fetches. Fetch a backup-only object and inspect access-denied logs.

Incorrect Answers

A:

CloudFront origin-group routing responds to configured eligible error codes, not every application response. Authorize CloudFront origin access to the backup bucket using the appropriate supported access control. Fetch a backup-only object and inspect access-denied logs.

C:

Automatic origin failover for mutations could duplicate side effects, so application-level resilience is necessary. Each private S3 origin needs its own correct bucket access policy for distribution fetches.

D:

Redundant origins and consistent object copies reduce dependence on one regional endpoint. Authorize CloudFront origin access to the backup bucket using the appropriate supported access control. Fetch a backup-only object and inspect access-denied logs.

Question 424

An origin failover works for misses but a stale cached error page persists at edge locations. What should be reviewed?

  1. Include the appropriate supported HTTP failure status in the origin-group failover criteria.
  2. Authorize CloudFront origin access to the backup bucket using the appropriate supported access control.
  3. CloudFront can serve still-valid cached objects without contacting an unhealthy origin.
  4. Set appropriate error-response caching behavior and use invalidation where justified.

Explanation

Correct Answer

D:

Error caching can preserve an outage symptom after the origin has recovered. Recover the origin and compare error TTL expiry to successful responses.

Incorrect Answers

A:

CloudFront origin-group routing responds to configured eligible error codes, not every application response. Set appropriate error-response caching behavior and use invalidation where justified. Recover the origin and compare error TTL expiry to successful responses.

B:

Each private S3 origin needs its own correct bucket access policy for distribution fetches. Set appropriate error-response caching behavior and use invalidation where justified. Recover the origin and compare error TTL expiry to successful responses.

C:

Edge caching isolates repeat reads until cache freshness rules require origin access. Set appropriate error-response caching behavior and use invalidation where justified. Recover the origin and compare error TTL expiry to successful responses.

Question 425

A private datacenter reaches AWS using one Direct Connect connection, and a fiber cut would sever connectivity. Which network design improves resilience?

  1. Provision redundant Direct Connect connectivity at suitable diverse locations and validate routing.
  2. Add a site-to-site VPN path with suitable route preference and capacity planning.
  3. Provide redundant customer-side VPN paths and correct Transit Gateway routing for failover.
  4. Use physically independent Direct Connect locations or failure domains.

Explanation

Correct Answer

A:

Physical diversity avoids a single circuit failure becoming a business-wide loss. Disable one connection and inspect BGP path failover and application reachability.

Incorrect Answers

B:

A VPN can provide failover connectivity over the internet, subject to bandwidth and latency limits. Provision redundant Direct Connect connectivity at suitable diverse locations and validate routing. Disable one connection and inspect BGP path failover and application reachability.

C:

Transit Gateway centralizes attachments but does not automatically make a single physical branch circuit resilient. Provision redundant Direct Connect connectivity at suitable diverse locations and validate routing. Disable one connection and inspect BGP path failover and application reachability.

D:

Two logical links sharing a single facility do not protect against that facility's outage. Provision redundant Direct Connect connectivity at suitable diverse locations and validate routing. Disable one connection and inspect BGP path failover and application reachability.

Question 426

An application needs an interim encrypted connectivity path when its Direct Connect circuit fails. What backup can be configured?

  1. Add a site-to-site VPN path with suitable route preference and capacity planning.
  2. Provide redundant hybrid DNS resolution paths and resolver endpoints as appropriate.
  3. Size and test the backup path for required critical traffic or define degraded-mode priorities.
  4. Configure both IPsec tunnels and compatible routing or failover on the customer gateway.

Explanation

Correct Answer

A:

A VPN can provide failover connectivity over the internet, subject to bandwidth and latency limits. Simulate Direct Connect loss and inspect protected VPN traffic.

Incorrect Answers

B:

A healthy data path cannot resolve private application names if the only DNS forwarder fails. Add a site-to-site VPN path with suitable route preference and capacity planning. Simulate Direct Connect loss and inspect protected VPN traffic.

C:

Failover is not equivalent to equal bandwidth; traffic volume may exceed VPN capacity. Add a site-to-site VPN path with suitable route preference and capacity planning. Simulate Direct Connect loss and inspect protected VPN traffic.

D:

A two-tunnel AWS VPN offers resilience only if the customer-side design uses both paths correctly. Add a site-to-site VPN path with suitable route preference and capacity planning. Simulate Direct Connect loss and inspect protected VPN traffic.

Question 427

A company has two VPN tunnels to AWS but its customer gateway uses only one fixed tunnel. How should it use redundancy?

  1. Add a site-to-site VPN path with suitable route preference and capacity planning.
  2. Size and test the backup path for required critical traffic or define degraded-mode priorities.
  3. Configure both IPsec tunnels and compatible routing or failover on the customer gateway.
  4. Provide redundant customer-side VPN paths and correct Transit Gateway routing for failover.

Explanation

Correct Answer

C:

A two-tunnel AWS VPN offers resilience only if the customer-side design uses both paths correctly. Disable the active tunnel and test data-path failover.

Incorrect Answers

A:

A VPN can provide failover connectivity over the internet, subject to bandwidth and latency limits. Configure both IPsec tunnels and compatible routing or failover on the customer gateway. Disable the active tunnel and test data-path failover.

B:

Failover is not equivalent to equal bandwidth; traffic volume may exceed VPN capacity. Configure both IPsec tunnels and compatible routing or failover on the customer gateway. Disable the active tunnel and test data-path failover.

D:

Transit Gateway centralizes attachments but does not automatically make a single physical branch circuit resilient. Configure both IPsec tunnels and compatible routing or failover on the customer gateway. Disable the active tunnel and test data-path failover.

Question 428

An application in AWS spans two AZs but connects through one NAT gateway in a third AZ. How should it reduce AZ dependency?

  1. Use physically independent Direct Connect locations or failure domains.
  2. Provision redundant Direct Connect connectivity at suitable diverse locations and validate routing.
  3. Deploy an appropriate NAT gateway per AZ and route each private subnet to its local-AZ gateway.
  4. Provide redundant hybrid DNS resolution paths and resolver endpoints as appropriate.

Explanation

Correct Answer

C:

Per-AZ egress reduces cross-AZ dependency and avoids an outage in one AZ affecting unrelated subnets. Disable one NAT gateway and verify other AZs retain outbound connections.

Incorrect Answers

A:

Two logical links sharing a single facility do not protect against that facility's outage. Deploy an appropriate NAT gateway per AZ and route each private subnet to its local-AZ gateway. Disable one NAT gateway and verify other AZs retain outbound connections.

B:

Physical diversity avoids a single circuit failure becoming a business-wide loss. Deploy an appropriate NAT gateway per AZ and route each private subnet to its local-AZ gateway. Disable one NAT gateway and verify other AZs retain outbound connections.

D:

A healthy data path cannot resolve private application names if the only DNS forwarder fails. Deploy an appropriate NAT gateway per AZ and route each private subnet to its local-AZ gateway. Disable one NAT gateway and verify other AZs retain outbound connections.

Question 429

A branch connects to multiple VPCs through a Transit Gateway but only one customer VPN attachment is active. What improves hybrid availability?

  1. Provide redundant hybrid DNS resolution paths and resolver endpoints as appropriate.
  2. Provision redundant Direct Connect connectivity at suitable diverse locations and validate routing.
  3. Configure both IPsec tunnels and compatible routing or failover on the customer gateway.
  4. Provide redundant customer-side VPN paths and correct Transit Gateway routing for failover.

Explanation

Correct Answer

D:

Transit Gateway centralizes attachments but does not automatically make a single physical branch circuit resilient. Bring down one site path and verify the alternate attachment route.

Incorrect Answers

A:

A healthy data path cannot resolve private application names if the only DNS forwarder fails. Provide redundant customer-side VPN paths and correct Transit Gateway routing for failover. Bring down one site path and verify the alternate attachment route.

B:

Physical diversity avoids a single circuit failure becoming a business-wide loss. Provide redundant customer-side VPN paths and correct Transit Gateway routing for failover. Bring down one site path and verify the alternate attachment route.

C:

A two-tunnel AWS VPN offers resilience only if the customer-side design uses both paths correctly. Provide redundant customer-side VPN paths and correct Transit Gateway routing for failover. Bring down one site path and verify the alternate attachment route.

Question 430

During a Direct Connect disruption, AWS traffic falls back to VPN and saturates the backup. What must be planned?

  1. Configure both IPsec tunnels and compatible routing or failover on the customer gateway.
  2. Size and test the backup path for required critical traffic or define degraded-mode priorities.
  3. Provide redundant customer-side VPN paths and correct Transit Gateway routing for failover.
  4. Provision redundant Direct Connect connectivity at suitable diverse locations and validate routing.

Explanation

Correct Answer

B:

Failover is not equivalent to equal bandwidth; traffic volume may exceed VPN capacity. Run a bounded peak-traffic test on the backup and record latency and loss.

Incorrect Answers

A:

A two-tunnel AWS VPN offers resilience only if the customer-side design uses both paths correctly. Size and test the backup path for required critical traffic or define degraded-mode priorities. Run a bounded peak-traffic test on the backup and record latency and loss.

C:

Transit Gateway centralizes attachments but does not automatically make a single physical branch circuit resilient. Size and test the backup path for required critical traffic or define degraded-mode priorities. Run a bounded peak-traffic test on the backup and record latency and loss.

D:

Physical diversity avoids a single circuit failure becoming a business-wide loss. Failover is not equivalent to equal bandwidth; traffic volume may exceed VPN capacity.