Amazon AWS Certified Solutions Architect - Associate SAA-C03 Practice Test 41
Question 400
A developer believes S3 versioning alone stops malware from modifying every version. What gap remains?
- Leave Object Lock disabled and rely only on S3 Versioning to prevent privileged deletion of every retained version.
- Enable S3 Versioning and retain prior object versions according to policy.
- Apply least-privilege access and immutable retention such as S3 Object Lock where required.
- Review S3 replication delete-marker behavior and destination retention separately.
Explanation
Correct Answer
C:Versioning aids recovery but authorized principals may delete or expire versions absent stronger controls. Try deleting a prior version under ordinary credentials and observe the policy result.
Incorrect Answers
A:Versioning retains older revisions after ordinary overwrites but does not itself establish immutability. An approved Object Lock retention mode or legal hold must protect required versions from prohibited deletion.
B:Versioning preserves overwritten versions so a prior object version can be recovered. Apply least-privilege access and immutable retention such as S3 Object Lock where required. Try deleting a prior version under ordinary credentials and observe the policy result.
D:Replication settings can propagate certain delete markers; independent retention and Object Lock control recovery policy. Apply least-privilege access and immutable retention such as S3 Object Lock where required. Try deleting a prior version under ordinary credentials and observe the policy result.
Question 401
An order platform has a strict regional disaster-recovery objective. It must recover with a warm secondary application tier, route users away from a failed Region, and preserve up-to-date cross-Region database state within an agreed RPO. Which THREE provisions are needed? (Select THREE.)
- Configure supported Route 53 failover health checks or a comparable global traffic-routing control.
- Maintain warm, tested application compute capacity in the standby Region that meets the RTO under expected failover load.
- Publish both Regions in DNS but leave the standby deployment with no usable compute.
- Declare recovery successful if the secondary application starts, without verifying database consistency or write availability.
- Use a supported cross-Region data-replication or recovery mechanism and measure its lag against RPO.
- Assume nightly backups meet a strict five-minute RPO with no further replication evidence.
Explanation
Correct Answers
A:A health-aware traffic decision directs users toward available regional endpoints after failure.
B:A standby Region without adequate compute cannot meet recovery-time targets even if its data is available.
E:Recoverability depends on the age and integrity of standby data, which must be tested separately from DNS or application readiness.
Incorrect Answers
C:DNS-only failover would route users to an endpoint without the required serving capacity.
D:A running web process alone does not demonstrate that the data tier meets RPO or can serve valid transactions.
F:A 24-hour backup interval does not substantiate a minutes-level recovery-point objective.
Question 402
A service must resume within tens of minutes and maintain a minimal always-on core in a second Region. Which strategy fits?
- Maintain a warm standby environment at reduced capacity in the secondary Region.
- Use backup-and-restore with tested infrastructure recovery automation.
- Implement pilot light with continuously available essential state and automated scale-up.
- Rehearse the full application dependency graph and document recovery automation and evidence.
Explanation
Correct Answer
C:Pilot light keeps the smallest required infrastructure running and rebuilds the rest during recovery. Execute a regional recovery rehearsal and measure spin-up time.
Incorrect Answers
A:Warm standby runs a functional smaller footprint that can be scaled up during disaster recovery. Implement pilot light with continuously available essential state and automated scale-up. Execute a regional recovery rehearsal and measure spin-up time.
B:Backup-and-restore minimizes active standby infrastructure but generally has a longer recovery time. Implement pilot light with continuously available essential state and automated scale-up. Execute a regional recovery rehearsal and measure spin-up time.
D:An untested standby cannot prove required RTO or functional service if critical dependencies are missing. Implement pilot light with continuously available essential state and automated scale-up. Execute a regional recovery rehearsal and measure spin-up time.
Question 403
A business requires recovery within minutes without paying for full active-active capacity. Which DR strategy often fits?
- Rehearse the full application dependency graph and document recovery automation and evidence.
- Implement pilot light with continuously available essential state and automated scale-up.
- Add health-based cross-Region traffic failover with appropriate DNS or global routing.
- Maintain a warm standby environment at reduced capacity in the secondary Region.
Explanation
Correct Answer
D:Warm standby runs a functional smaller footprint that can be scaled up during disaster recovery. Shift test traffic to standby and observe readiness and scaling time.
Incorrect Answers
A:An untested standby cannot prove required RTO or functional service if critical dependencies are missing. Maintain a warm standby environment at reduced capacity in the secondary Region. Shift test traffic to standby and observe readiness and scaling time.
B:Pilot light keeps the smallest required infrastructure running and rebuilds the rest during recovery. Maintain a warm standby environment at reduced capacity in the secondary Region. Shift test traffic to standby and observe readiness and scaling time.
C:Data replication is only one dependency; service traffic must reach the available secondary stack. Maintain a warm standby environment at reduced capacity in the secondary Region. Shift test traffic to standby and observe readiness and scaling time.
Question 404
An application has near-zero tolerance for regional outages and can fund two full serving deployments. Which DR pattern suits it?
- Use backup-and-restore with tested infrastructure recovery automation.
- Implement pilot light with continuously available essential state and automated scale-up.
- Add health-based cross-Region traffic failover with appropriate DNS or global routing.
- Use a multi-site active-active architecture with suitable replicated state and traffic steering.
Explanation
Correct Answer
D:Active-active keeps serving capacity in multiple locations and requires conflict-aware data design. Fail one location and measure continuity of successful transactions.
Incorrect Answers
A:Backup-and-restore minimizes active standby infrastructure but generally has a longer recovery time. Use a multi-site active-active architecture with suitable replicated state and traffic steering. Fail one location and measure continuity of successful transactions.
B:Pilot light keeps the smallest required infrastructure running and rebuilds the rest during recovery. Use a multi-site active-active architecture with suitable replicated state and traffic steering. Fail one location and measure continuity of successful transactions.
C:Data replication is only one dependency; service traffic must reach the available secondary stack. Use a multi-site active-active architecture with suitable replicated state and traffic steering. Fail one location and measure continuity of successful transactions.
Question 405
A team calls its DR plan zero-data-loss, but it asynchronously replicates database writes between Regions. What must be revised?
- Set an RPO consistent with measured asynchronous replication lag and business acceptance.
- Implement pilot light with continuously available essential state and automated scale-up.
- Maintain a warm standby environment at reduced capacity in the secondary Region.
- Add health-based cross-Region traffic failover with appropriate DNS or global routing.
Explanation
Correct Answer
A:Asynchronous cross-Region replication can lose in-flight updates if the primary fails before propagation. Commit test writes and measure acknowledged-versus-replicated boundaries.
Incorrect Answers
B:Pilot light keeps the smallest required infrastructure running and rebuilds the rest during recovery. Set an RPO consistent with measured asynchronous replication lag and business acceptance. Commit test writes and measure acknowledged-versus-replicated boundaries.
C:Warm standby runs a functional smaller footprint that can be scaled up during disaster recovery. Set an RPO consistent with measured asynchronous replication lag and business acceptance. Commit test writes and measure acknowledged-versus-replicated boundaries.
D:Data replication is only one dependency; service traffic must reach the available secondary stack. Set an RPO consistent with measured asynchronous replication lag and business acceptance. Commit test writes and measure acknowledged-versus-replicated boundaries.
Question 406
A recovery plan says RTO is five minutes but restoring backups and provisioning takes two hours. What should the architect do?
- Use backup-and-restore with tested infrastructure recovery automation.
- Rehearse the full application dependency graph and document recovery automation and evidence.
- Maintain a warm standby environment at reduced capacity in the secondary Region.
- Choose a faster standby pattern or revise the promised RTO based on tested recovery steps.
Explanation
Correct Answer
D:RTO measures elapsed restoration time; a backup alone cannot satisfy a very short RTO. Run recovery drills and record application service restoration time.
Incorrect Answers
A:Backup-and-restore minimizes active standby infrastructure but generally has a longer recovery time. Choose a faster standby pattern or revise the promised RTO based on tested recovery steps. Run recovery drills and record application service restoration time.
B:An untested standby cannot prove required RTO or functional service if critical dependencies are missing. Choose a faster standby pattern or revise the promised RTO based on tested recovery steps. Run recovery drills and record application service restoration time.
C:Warm standby runs a functional smaller footprint that can be scaled up during disaster recovery. Choose a faster standby pattern or revise the promised RTO based on tested recovery steps. Run recovery drills and record application service restoration time.
Question 407
An application fails in Region A but the database is already current in Region B. Users still cannot connect because DNS routing is static. What must complete DR?
- Set an RPO consistent with measured asynchronous replication lag and business acceptance.
- Maintain a warm standby environment at reduced capacity in the secondary Region.
- Rehearse the full application dependency graph and document recovery automation and evidence.
- Add health-based cross-Region traffic failover with appropriate DNS or global routing.
Explanation
Correct Answer
D:Data replication is only one dependency; service traffic must reach the available secondary stack. Simulate primary unavailability and track client endpoint changes.
Incorrect Answers
A:Asynchronous cross-Region replication can lose in-flight updates if the primary fails before propagation. Add health-based cross-Region traffic failover with appropriate DNS or global routing. Simulate primary unavailability and track client endpoint changes.
B:Warm standby runs a functional smaller footprint that can be scaled up during disaster recovery. Add health-based cross-Region traffic failover with appropriate DNS or global routing. Simulate primary unavailability and track client endpoint changes.
C:An untested standby cannot prove required RTO or functional service if critical dependencies are missing. Add health-based cross-Region traffic failover with appropriate DNS or global routing. Simulate primary unavailability and track client endpoint changes.
Question 408
A company has a standby deployment but no tested recovery steps for secrets, networking, or partner allowlists. What should its DR program include?
- Choose a faster standby pattern or revise the promised RTO based on tested recovery steps.
- Maintain a warm standby environment at reduced capacity in the secondary Region.
- Rehearse the full application dependency graph and document recovery automation and evidence.
- Implement pilot light with continuously available essential state and automated scale-up.
Explanation
Correct Answer
C:An untested standby cannot prove required RTO or functional service if critical dependencies are missing. Run an end-to-end cutover that validates partner access and data correctness.
Incorrect Answers
A:RTO measures elapsed restoration time; a backup alone cannot satisfy a very short RTO. Rehearse the full application dependency graph and document recovery automation and evidence. Run an end-to-end cutover that validates partner access and data correctness.
B:Warm standby runs a functional smaller footprint that can be scaled up during disaster recovery. Rehearse the full application dependency graph and document recovery automation and evidence. Run an end-to-end cutover that validates partner access and data correctness.
D:Pilot light keeps the smallest required infrastructure running and rebuilds the rest during recovery. An untested standby cannot prove required RTO or functional service if critical dependencies are missing.
Question 409
A company wants centralized scheduled backups across EBS, RDS, and supported AWS resources. Which service coordinates policy centrally?
- Use separate backup plans or policy selections with reliable resource tags.
- Use AWS Backup plans and resource assignments for supported services.
- Adjust AWS Backup plan lifecycle and vault retention to the required policy period.
- Configure AWS Backup Vault Lock in an appropriate supported governance or compliance mode.
Explanation
Correct Answer
B:AWS Backup centralizes scheduling, retention, and recovery-point management for supported resources. Create a tagged resource and verify its recovery point appears in the vault.
Incorrect Answers
A:Scoped assignments apply different recovery-point schedules and lifecycles to distinct resource classes. Use AWS Backup plans and resource assignments for supported services. Create a tagged resource and verify its recovery point appears in the vault.
C:Recovery-point retention is governed by lifecycle and vault controls rather than an application's data TTL. Use AWS Backup plans and resource assignments for supported services. Create a tagged resource and verify its recovery point appears in the vault.
D:Vault Lock enforces retention controls that can restrict unauthorized modification and deletion. Use AWS Backup plans and resource assignments for supported services. Create a tagged resource and verify its recovery point appears in the vault.
Question 410
An attacker gains write access to a backup vault and tries to shorten retention. Which safeguard reduces that risk?
- Copy eligible recovery points into a separately controlled backup account and vault.
- Use AWS Backup plans and resource assignments for supported services.
- Configure AWS Backup Vault Lock in an appropriate supported governance or compliance mode.
- Adjust AWS Backup plan lifecycle and vault retention to the required policy period.
Explanation
Correct Answer
C:Vault Lock enforces retention controls that can restrict unauthorized modification and deletion. Try an early delete against a retained recovery point with a limited test identity.
Incorrect Answers
A:Cross-account copies separate backup administration from compromised production principals. Configure AWS Backup Vault Lock in an appropriate supported governance or compliance mode. Try an early delete against a retained recovery point with a limited test identity.
B:AWS Backup centralizes scheduling, retention, and recovery-point management for supported resources. Configure AWS Backup Vault Lock in an appropriate supported governance or compliance mode. Try an early delete against a retained recovery point with a limited test identity.
D:Recovery-point retention is governed by lifecycle and vault controls rather than an application's data TTL. Configure AWS Backup Vault Lock in an appropriate supported governance or compliance mode. Try an early delete against a retained recovery point with a limited test identity.