VMware 2V0-21.23 Practice Test 6

Question 50

At a vSphere 8.x change advisory panel, administrators consider the issue titled Select vSAN ESA prerequisites carefully. The production symptom was: A plan mixes legacy disk-group assumptions into an Express Storage Architecture deployment with unsuitable devices. The panel requires a coherent explanation of why the issue occurs, a bounded repair that respects change approval, and a measurable post-change outcome. Other technically plausible choices concern different infrastructure problems. Select EXACTLY THREE: a governing principle, the matching corrective action and its independent acceptance condition.

  1. Choose an ESA-qualified cluster design rather than reusing unsupported OSA disk-group patterns.
  2. vSphere FT provides continuous secondary execution for supported VMs within explicit resource and compatibility limits.
  3. Configure the datastore using the protocol-specific supported VMFS or NFS workflow and access settings.
  4. The cluster passes health validation and advertises the selected ESA architecture without unsupported disks.
  5. vSAN ESA is a distinct vSphere 8 storage architecture with its own supported hardware and networking criteria.
  6. Compatible disks redistribute with available free space and storage policy compliance maintained.

Explanation

Correct Answers

A:

Choose an ESA-qualified cluster design rather than reusing unsupported OSA disk-group patterns. vSAN ESA is a distinct vSphere 8 storage architecture with its own supported hardware and networking criteria. The cluster passes health validation and advertises the selected ESA architecture without unsupported disks.

D:

The cluster passes health validation and advertises the selected ESA architecture without unsupported disks. Choose an ESA-qualified cluster design rather than reusing unsupported OSA disk-group patterns. vSAN ESA is a distinct vSphere 8 storage architecture with its own supported hardware and networking criteria.

E:

vSAN ESA is a distinct vSphere 8 storage architecture with its own supported hardware and networking criteria. Choose an ESA-qualified cluster design rather than reusing unsupported OSA disk-group patterns. The cluster passes health validation and advertises the selected ESA architecture without unsupported disks.

Incorrect Answers

B:

vSphere FT provides continuous secondary execution for supported VMs within explicit resource and compatibility limits. It is not the rule that supports the proposed change and acceptance test: A plan mixes legacy disk-group assumptions into an Express Storage Architecture deployment with unsuitable devices. vSAN ESA is a distinct vSphere 8 storage architecture with its own supported hardware and networking criteria. Choose an ESA-qualified cluster design rather than reusing unsupported OSA disk-group patterns.

C:

Configure the datastore using the protocol-specific supported VMFS or NFS workflow and access settings. It does not implement the governing rule for this approval: A plan mixes legacy disk-group assumptions into an Express Storage Architecture deployment with unsuitable devices. Choose an ESA-qualified cluster design rather than reusing unsupported OSA disk-group patterns. The cluster passes health validation and advertises the selected ESA architecture without unsupported disks.

F:

Compatible disks redistribute with available free space and storage policy compliance maintained. It would not independently demonstrate that the control works: A plan mixes legacy disk-group assumptions into an Express Storage Architecture deployment with unsuitable devices. The cluster passes health validation and advertises the selected ESA architecture without unsupported disks. Choose an ESA-qualified cluster design rather than reusing unsupported OSA disk-group patterns.

Question 51

A VMware vSphere 8.x architecture assessment addresses Separate DRS from high availability. The team documents this infrastructure state: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. An administrator must distinguish the technical responsibility or mechanism before proposing configuration changes. Which single governing vSphere principle most accurately explains what is required, rather than a diagnostic or implementation step? Choose ONE answer.

  1. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior.
  2. Supervisor Namespace policy and identity boundaries determine who may consume vSphere Kubernetes resources.
  3. A VSS is administered on each host, while a VDS centralizes compatible switch and distributed-port configuration.
  4. VMFS commonly uses supported block devices, whereas NFS datastores mount a network file share.

Explanation

Correct Answer

A:

DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

Incorrect Answers

B:

Supervisor Namespace policy and identity boundaries determine who may consume vSphere Kubernetes resources. It does not govern the condition described: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior.

C:

A VSS is administered on each host, while a VDS centralizes compatible switch and distributed-port configuration. It does not govern the condition described: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior.

D:

VMFS commonly uses supported block devices, whereas NFS datastores mount a network file share. It does not govern the condition described: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior.

Question 52

During a VMware vSphere 8.x incident investigation, a separate operations report states: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. The failure could carry this operational consequence: Conflating placement optimization with recovery can leave critical VMs unprotected. Before any administrator applies a change, the technical team needs proof from configuration, topology or observed behavior; intuition alone is not sufficient. Which single diagnostic check best establishes the decisive condition? Choose ONE answer.

  1. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently.
  2. Verify VM vCPU configuration, datastore/network requirements, supported device options and FT policy availability.
  3. Check VM console reachability through direct host management, host heartbeat status and vCenter service health separately.
  4. Inspect datastore type, host discovery results, presented LUN or share permissions and cluster mapping.

Explanation

Correct Answer

A:

Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

Incorrect Answers

B:

Verify VM vCPU configuration, datastore/network requirements, supported device options and FT policy availability. That check would not establish the decisive facts for this condition: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently.

C:

Check VM console reachability through direct host management, host heartbeat status and vCenter service health separately. That check would not establish the decisive facts for this condition: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently.

D:

Inspect datastore type, host discovery results, presented LUN or share permissions and cluster mapping. That check would not establish the decisive facts for this condition: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently.

Question 53

A change-control ticket for VMware ESXi and vCenter 8.x concerns Separate DRS from high availability. The reported problem is: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Investigation is complete. A planned maintenance window must protect existing guests and preserve a safe rollback path. Which single supported, scoped administration action most directly resolves this condition without modifying unrelated workloads? Choose ONE answer.

  1. Enable or use supported storage offload only where capability checks confirm array interoperability.
  2. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.
  3. Use the supported DPU-compatible workflow instead of enabling unsupported offloads on ordinary NICs.
  4. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

Explanation

Correct Answer

B:

Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.

Incorrect Answers

A:

Enable or use supported storage offload only where capability checks confirm array interoperability. That change would leave the reported problem unresolved: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

C:

Use the supported DPU-compatible workflow instead of enabling unsupported offloads on ordinary NICs. That change would leave the reported problem unresolved: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

D:

Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it. That change would leave the reported problem unresolved: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

Question 54

An operational assurance reviewer is evaluating a VMware vSphere 8.x repair after this report: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. The reason for caution is: Conflating placement optimization with recovery can leave critical VMs unprotected. The team needs one fact-based check from BEFORE implementation and one independent observation demonstrating success AFTER the change. Select EXACTLY TWO answers with those two different roles; not two checks or two corrective actions.

  1. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.
  2. Compare local host switch inventory with distributed switch membership, uplinks and backing port groups.
  3. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently.
  4. The application deploys in its intended namespace and health checks reflect both management layers.
  5. Inspect datastore type, host discovery results, presented LUN or share permissions and cluster mapping.

Explanation

Correct Answers

A:

A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior.

C:

Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

Incorrect Answers

B:

Compare local host switch inventory with distributed switch membership, uplinks and backing port groups. It would not provide the evidence needed for the paired diagnosis and follow-up: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.

D:

The application deploys in its intended namespace and health checks reflect both management layers. It would not verify whether the proposed change works: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

E:

Inspect datastore type, host discovery results, presented LUN or share permissions and cluster mapping. It would not provide the evidence needed for the paired diagnosis and follow-up: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Inspect both cluster DRS settings and HA admission, isolation and restart configurations independently. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.

Question 55

At a vSphere 8.x change advisory panel, administrators consider the issue titled Separate DRS from high availability. The production symptom was: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. The panel requires a coherent explanation of why the issue occurs, a bounded repair that respects change approval, and a measurable post-change outcome. Other technically plausible choices concern different infrastructure problems. Select EXACTLY THREE: a governing principle, the matching corrective action and its independent acceptance condition.

  1. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior.
  2. Shared storage requires supported access and consistent visibility from all participating ESXi hosts.
  3. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.
  4. Encrypted guests remain accessible after controlled management recovery without exposing cryptographic keys.
  5. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.
  6. Create or correct a dedicated supported VMkernel service path without exposing host management services to guest VLANs.

Explanation

Correct Answers

A:

DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.

C:

Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.

E:

A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior.

Incorrect Answers

B:

Shared storage requires supported access and consistent visibility from all participating ESXi hosts. It is not the rule that supports the proposed change and acceptance test: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. DRS optimizes placement and load while vSphere HA addresses supported failure detection and VM restart behavior. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

D:

Encrypted guests remain accessible after controlled management recovery without exposing cryptographic keys. It would not independently demonstrate that the control works: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity.

F:

Create or correct a dedicated supported VMkernel service path without exposing host management services to guest VLANs. It does not implement the governing rule for this approval: A customer asks DRS to restart VMs after a physical host powers off and expects load balancing alone to ensure failover. Enable and validate HA for failure response and DRS for resource-placement optimization with spare capacity. A controlled host-failure test restarts protected VMs and normal load balancing resumes afterward.

Question 56

A VMware vSphere 8.x architecture assessment addresses Plan EVC across mixed CPU generations. The team documents this infrastructure state: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. An administrator must distinguish the technical responsibility or mechanism before proposing configuration changes. Which single governing vSphere principle most accurately explains what is required, rather than a diagnostic or implementation step? Choose ONE answer.

  1. Management control-plane interruption does not itself terminate running guest execution on healthy ESXi hosts.
  2. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations.
  3. A Supervisor provides control for Kubernetes-integrated services and TKG clusters provide separate guest Kubernetes execution scopes.
  4. Storage DRS evaluates datastore space and I/O placement separately from host CPU and memory DRS.

Explanation

Correct Answer

B:

EVC creates a compatible CPU feature baseline to support supported cross-host live migrations. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

Incorrect Answers

A:

Management control-plane interruption does not itself terminate running guest execution on healthy ESXi hosts. It does not govern the condition described: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations.

C:

A Supervisor provides control for Kubernetes-integrated services and TKG clusters provide separate guest Kubernetes execution scopes. It does not govern the condition described: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations.

D:

Storage DRS evaluates datastore space and I/O placement separately from host CPU and memory DRS. It does not govern the condition described: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations.

Question 57

During a VMware vSphere 8.x incident investigation, a separate operations report states: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. The failure could carry this operational consequence: A too-high EVC baseline can strand workloads on older hosts. Before any administrator applies a change, the technical team needs proof from configuration, topology or observed behavior; intuition alone is not sufficient. Which single diagnostic check best establishes the decisive condition? Choose ONE answer.

  1. Review uplink capacity, NIOC settings and measured contention by system traffic type.
  2. Verify VM vCPU configuration, datastore/network requirements, supported device options and FT policy availability.
  3. Review Supervisor service health, namespace topology and associated TKG cluster lifecycle state.
  4. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state.

Explanation

Correct Answer

D:

Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

Incorrect Answers

A:

Review uplink capacity, NIOC settings and measured contention by system traffic type. That check would not establish the decisive facts for this condition: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state.

B:

Verify VM vCPU configuration, datastore/network requirements, supported device options and FT policy availability. That check would not establish the decisive facts for this condition: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state.

C:

Review Supervisor service health, namespace topology and associated TKG cluster lifecycle state. That check would not establish the decisive facts for this condition: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state.

Question 58

A change-control ticket for VMware ESXi and vCenter 8.x concerns Plan EVC across mixed CPU generations. The reported problem is: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Investigation is complete. A planned maintenance window must protect existing guests and preserve a safe rollback path. Which single supported, scoped administration action most directly resolves this condition without modifying unrelated workloads? Choose ONE answer.

  1. Repair the missing supported SAN path and confirm expected path selection under controlled tests.
  2. Configure supported reachable time sources and validate synchronization before enabling sensitive workflows.
  3. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.
  4. Select VSS or VDS based on cross-host policy needs and migrate uplinks through a tested sequence.

Explanation

Correct Answer

C:

Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state. Approved live migrations succeed between compatible hosts without changing guest workload behavior.

Incorrect Answers

A:

Repair the missing supported SAN path and confirm expected path selection under controlled tests. That change would leave the reported problem unresolved: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

B:

Configure supported reachable time sources and validate synchronization before enabling sensitive workflows. That change would leave the reported problem unresolved: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

D:

Select VSS or VDS based on cross-host policy needs and migrate uplinks through a tested sequence. That change would leave the reported problem unresolved: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

Question 59

An operational assurance reviewer is evaluating a VMware vSphere 8.x repair after this report: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. The reason for caution is: A too-high EVC baseline can strand workloads on older hosts. The team needs one fact-based check from BEFORE implementation and one independent observation demonstrating success AFTER the change. Select EXACTLY TWO answers with those two different roles; not two checks or two corrective actions.

  1. The protected application continues through a supported single-host failure within its expected continuity goal.
  2. Compare host client capabilities with vCenter inventory, connectivity and required management workflows.
  3. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state.
  4. Compare per-host compliance, hardware compatibility, depot content and active maintenance state.
  5. Approved live migrations succeed between compatible hosts without changing guest workload behavior.

Explanation

Correct Answers

C:

Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state. Approved live migrations succeed between compatible hosts without changing guest workload behavior. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

E:

Approved live migrations succeed between compatible hosts without changing guest workload behavior. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations.

Incorrect Answers

A:

The protected application continues through a supported single-host failure within its expected continuity goal. It would not verify whether the proposed change works: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Approved live migrations succeed between compatible hosts without changing guest workload behavior. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

B:

Compare host client capabilities with vCenter inventory, connectivity and required management workflows. It would not provide the evidence needed for the paired diagnosis and follow-up: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state. Approved live migrations succeed between compatible hosts without changing guest workload behavior.

D:

Compare per-host compliance, hardware compatibility, depot content and active maintenance state. It would not provide the evidence needed for the paired diagnosis and follow-up: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Inspect source and destination CPU vendors, guest CPU features, existing EVC mode and VM power state. Approved live migrations succeed between compatible hosts without changing guest workload behavior.

Question 60

At a vSphere 8.x change advisory panel, administrators consider the issue titled Plan EVC across mixed CPU generations. The production symptom was: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. The panel requires a coherent explanation of why the issue occurs, a bounded repair that respects change approval, and a measurable post-change outcome. Other technically plausible choices concern different infrastructure problems. Select EXACTLY THREE: a governing principle, the matching corrective action and its independent acceptance condition.

  1. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.
  2. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations.
  3. Approved live migrations succeed between compatible hosts without changing guest workload behavior.
  4. Configure supported reachable time sources and validate synchronization before enabling sensitive workflows.
  5. The application deploys in its intended namespace and health checks reflect both management layers.
  6. Shared storage requires supported access and consistent visibility from all participating ESXi hosts.

Explanation

Correct Answers

A:

Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations. Approved live migrations succeed between compatible hosts without changing guest workload behavior.

B:

EVC creates a compatible CPU feature baseline to support supported cross-host live migrations. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it. Approved live migrations succeed between compatible hosts without changing guest workload behavior.

C:

Approved live migrations succeed between compatible hosts without changing guest workload behavior. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations.

Incorrect Answers

D:

Configure supported reachable time sources and validate synchronization before enabling sensitive workflows. It does not implement the governing rule for this approval: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it. Approved live migrations succeed between compatible hosts without changing guest workload behavior.

E:

The application deploys in its intended namespace and health checks reflect both management layers. It would not independently demonstrate that the control works: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. Approved live migrations succeed between compatible hosts without changing guest workload behavior. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

F:

Shared storage requires supported access and consistent visibility from all participating ESXi hosts. It is not the rule that supports the proposed change and acceptance test: A VM migrates between older and newer CPUs but fails when guest-exposed instruction sets differ. EVC creates a compatible CPU feature baseline to support supported cross-host live migrations. Choose a supported common EVC baseline and assess whether VM restart is needed to adopt it.

VMware vSphere 8.x Professional (2V0-21.23) Practice Tests