Network Appliance NS0-094 Practice Test 65
Question 640
Fictional NetApp hardware-support incident R376-C160: A client LUN is not mapped in its SVM yet technicians propose replacing the shelf. What validation result would justify closing this support finding?
- Recovery point and supported scope are explicitly verified
- Capacity plan reconciles effective savings with actual spare headroom
- Only demonstrated filesystem or physical faults receive invasive recovery
- Support isolates the affected logical layer before FRU dispatch
Explanation
Correct Answer
D:Support isolates the affected logical layer before FRU dispatch. This outcome would specifically test whether one logical tenant outage is misdiagnosed as total chassis failure has been corrected in the fictional situation: A client LUN is not mapped in its SVM yet technicians propose replacing the shelf.. It should follow the supported response distinguish svm protocols, logical interfaces and data volumes from physical controllers and shelves, with evidence from check svm and lif associations and map volume and aggregate to serving node and underlying media. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Recovery point and supported scope are explicitly verified could be a positive validation for the adjacent topic Snapshot consistency and restore scope, but is insufficient to close this fault. The case reports A client LUN is not mapped in its SVM yet technicians propose replacing the shelf.. Its direct acceptance condition is that support isolates the affected logical layer before fru dispatch, after the appropriate action distinguish svm protocols, logical interfaces and data volumes from physical controllers and shelves. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Capacity plan reconciles effective savings with actual spare headroom could be a positive validation for the adjacent topic Storage efficiency before capacity change, but is insufficient to close this fault. The case reports A client LUN is not mapped in its SVM yet technicians propose replacing the shelf.. Its direct acceptance condition is that support isolates the affected logical layer before fru dispatch, after the appropriate action distinguish svm protocols, logical interfaces and data volumes from physical controllers and shelves. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Only demonstrated filesystem or physical faults receive invasive recovery could be a positive validation for the adjacent topic WAFL consistency and filesystem health, but is insufficient to close this fault. The case reports A client LUN is not mapped in its SVM yet technicians propose replacing the shelf.. Its direct acceptance condition is that support isolates the affected logical layer before fru dispatch, after the appropriate action distinguish svm protocols, logical interfaces and data volumes from physical controllers and shelves. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 641
Fictional NetApp hardware-support incident R376-C161: The cluster admin interface responds while a client VLAN data LIF is down. Which approved diagnostic or corrective step should be selected first?
- Diagnose management-LIF reachability separately from client data-LIF access
- Assign ONTAP ports to appropriate broadcast domains based on layer 2 reachability
- Verify failover group, policies and current home-node port when clients lose access after link change
- Verify SAN LUN mapping to correct igroup initiators and host visibility
Explanation
Correct Answer
A:Diagnose management-LIF reachability separately from client data-LIF access. This is the targeted supported response because successful cluster admin ping is treated as proof nfs data access works. The fictional incident is: The cluster admin interface responds while a client VLAN data LIF is down.. The technician should first correlate identify service policy and home port of each lif with compare management route with data network path, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that the intended management or data endpoint is independently reachable. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Assign ONTAP ports to appropriate broadcast domains based on layer 2 reachability is a legitimate focus when investigating Broadcast domains and ports, but it does not resolve the reported management versus data lif failure. In this particular incident, The cluster admin interface responds while a client VLAN data LIF is down.. The decisive checks are identify service policy and home port of each lif and compare management route with data network path; these isolate why successful cluster admin ping is treated as proof nfs data access works. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is diagnose management-lif reachability separately from client data-lif access. Expert review has not yet confirmed option exclusivity.
C:Verify failover group, policies and current home-node port when clients lose access after link change is a legitimate focus when investigating LIF failover and home port, but it does not resolve the reported management versus data lif failure. In this particular incident, The cluster admin interface responds while a client VLAN data LIF is down.. The decisive checks are identify service policy and home port of each lif and compare management route with data network path; these isolate why successful cluster admin ping is treated as proof nfs data access works. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is diagnose management-lif reachability separately from client data-lif access. Expert review has not yet confirmed option exclusivity.
D:Verify SAN LUN mapping to correct igroup initiators and host visibility is a legitimate focus when investigating LUN mapping and igroup, but it does not resolve the reported management versus data lif failure. In this particular incident, The cluster admin interface responds while a client VLAN data LIF is down.. The decisive checks are identify service policy and home port of each lif and compare management route with data network path; these isolate why successful cluster admin ping is treated as proof nfs data access works. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is diagnose management-lif reachability separately from client data-lif access. Expert review has not yet confirmed option exclusivity.
Question 642
Fictional NetApp hardware-support incident R376-C161: The cluster admin interface responds while a client VLAN data LIF is down. Which check should be requested first to test the reported condition?
- Inspect matching export policy rules
- Identify service policy and home port of each LIF
- Check LIF current port versus home port
- Check network path to target portals
Explanation
Correct Answer
B:Identify service policy and home port of each LIF is directly relevant evidence for the management versus data lif scenario. Pair it with compare management route with data network path when both are called for to establish whether successful cluster admin ping is treated as proof nfs data access works. The support case reports The cluster admin interface responds while a client VLAN data LIF is down.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that the intended management or data endpoint is independently reachable. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Inspect matching export policy rules may be appropriate for a separate nfs export policy specificity case, but is not the most discriminating check in this incident: The cluster admin interface responds while a client VLAN data LIF is down.. The described failure is successful cluster admin ping is treated as proof nfs data access works. The targeted evidence is identify service policy and home port of each lif together with compare management route with data network path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Check LIF current port versus home port may be appropriate for a separate lif failover and home port case, but is not the most discriminating check in this incident: The cluster admin interface responds while a client VLAN data LIF is down.. The described failure is successful cluster admin ping is treated as proof nfs data access works. The targeted evidence is identify service policy and home port of each lif together with compare management route with data network path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Check network path to target portals may be appropriate for a separate iscsi target discovery and session case, but is not the most discriminating check in this incident: The cluster admin interface responds while a client VLAN data LIF is down.. The described failure is successful cluster admin ping is treated as proof nfs data access works. The targeted evidence is identify service policy and home port of each lif together with compare management route with data network path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 643
Fictional NetApp hardware-support incident R376-C161: The cluster admin interface responds while a client VLAN data LIF is down. What assumption should the engineer reject before touching equipment?
- A client is not authorized by export policy yet hardware is blamed
- Host cannot see LUN because SAN fabric zoning omits its initiator
- Successful cluster admin ping is treated as proof NFS data access works
- Ports from unrelated layer 2 networks are treated as one failover domain
Explanation
Correct Answer
C:Successful cluster admin ping is treated as proof NFS data access works. This diagnosis fits the original incident, The cluster admin interface responds while a client VLAN data LIF is down., rather than requiring an unrelated service action. Check identify service policy and home port of each lif and compare management route with data network path to confirm the location and status of the affected resource. The relevant corrective response is diagnose management-lif reachability separately from client data-lif access, with final acceptance when the intended management or data endpoint is independently reachable. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:A client is not authorized by export policy yet hardware is blamed describes a possible failure in the neighboring topic NFS export policy specificity, not the main mechanism demonstrated here. The actual scenario is The cluster admin interface responds while a client VLAN data LIF is down.; the more direct diagnosis is successful cluster admin ping is treated as proof nfs data access works. Confirm it from identify service policy and home port of each lif and compare management route with data network path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:Host cannot see LUN because SAN fabric zoning omits its initiator describes a possible failure in the neighboring topic Fibre Channel zoning correctness, not the main mechanism demonstrated here. The actual scenario is The cluster admin interface responds while a client VLAN data LIF is down.; the more direct diagnosis is successful cluster admin ping is treated as proof nfs data access works. Confirm it from identify service policy and home port of each lif and compare management route with data network path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:Ports from unrelated layer 2 networks are treated as one failover domain describes a possible failure in the neighboring topic Broadcast domains and ports, not the main mechanism demonstrated here. The actual scenario is The cluster admin interface responds while a client VLAN data LIF is down.; the more direct diagnosis is successful cluster admin ping is treated as proof nfs data access works. Confirm it from identify service policy and home port of each lif and compare management route with data network path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 644
Fictional NetApp hardware-support incident R376-C161: The cluster admin interface responds while a client VLAN data LIF is down. Which test result best shows restoration of the intended protected behavior?
- Only intended host initiators can access the mapped LUN
- Appropriate host paths are visible through approved FC zones
- Supported initiator logs in and sees the intended presented LUN
- The intended management or data endpoint is independently reachable
Explanation
Correct Answer
D:The intended management or data endpoint is independently reachable. This outcome would specifically test whether successful cluster admin ping is treated as proof nfs data access works has been corrected in the fictional situation: The cluster admin interface responds while a client VLAN data LIF is down.. It should follow the supported response diagnose management-lif reachability separately from client data-lif access, with evidence from identify service policy and home port of each lif and compare management route with data network path. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Only intended host initiators can access the mapped LUN could be a positive validation for the adjacent topic LUN mapping and igroup, but is insufficient to close this fault. The case reports The cluster admin interface responds while a client VLAN data LIF is down.. Its direct acceptance condition is that the intended management or data endpoint is independently reachable, after the appropriate action diagnose management-lif reachability separately from client data-lif access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Appropriate host paths are visible through approved FC zones could be a positive validation for the adjacent topic Fibre Channel zoning correctness, but is insufficient to close this fault. The case reports The cluster admin interface responds while a client VLAN data LIF is down.. Its direct acceptance condition is that the intended management or data endpoint is independently reachable, after the appropriate action diagnose management-lif reachability separately from client data-lif access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Supported initiator logs in and sees the intended presented LUN could be a positive validation for the adjacent topic ISCSI target discovery and session, but is insufficient to close this fault. The case reports The cluster admin interface responds while a client VLAN data LIF is down.. Its direct acceptance condition is that the intended management or data endpoint is independently reachable, after the appropriate action diagnose management-lif reachability separately from client data-lif access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 645
Fictional NetApp hardware-support incident R376-C162: A technician moves a data LIF to an isolated management network to fix user traffic. Which supported next step addresses the diagnosed fault while preserving the healthy parts of the system?
- Diagnose management-LIF reachability separately from client data-LIF access
- Verify failover group, policies and current home-node port when clients lose access after link change
- Verify export rules, client match and access protocols before assigning a NAS client outage to hardware
- Confirm initiator/target WWPN zoning and port states for supported FC host access
Explanation
Correct Answer
A:Diagnose management-LIF reachability separately from client data-LIF access. This is the targeted supported response because successful cluster admin ping is treated as proof nfs data access works. The fictional incident is: A technician moves a data LIF to an isolated management network to fix user traffic.. The technician should first correlate identify service policy and home port of each lif with compare management route with data network path, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that the intended management or data endpoint is independently reachable. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Verify failover group, policies and current home-node port when clients lose access after link change is a legitimate focus when investigating LIF failover and home port, but it does not resolve the reported management versus data lif failure. In this particular incident, A technician moves a data LIF to an isolated management network to fix user traffic.. The decisive checks are identify service policy and home port of each lif and compare management route with data network path; these isolate why successful cluster admin ping is treated as proof nfs data access works. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is diagnose management-lif reachability separately from client data-lif access. Expert review has not yet confirmed option exclusivity.
C:Verify export rules, client match and access protocols before assigning a NAS client outage to hardware is a legitimate focus when investigating NFS export policy specificity, but it does not resolve the reported management versus data lif failure. In this particular incident, A technician moves a data LIF to an isolated management network to fix user traffic.. The decisive checks are identify service policy and home port of each lif and compare management route with data network path; these isolate why successful cluster admin ping is treated as proof nfs data access works. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is diagnose management-lif reachability separately from client data-lif access. Expert review has not yet confirmed option exclusivity.
D:Confirm initiator/target WWPN zoning and port states for supported FC host access is a legitimate focus when investigating Fibre Channel zoning correctness, but it does not resolve the reported management versus data lif failure. In this particular incident, A technician moves a data LIF to an isolated management network to fix user traffic.. The decisive checks are identify service policy and home port of each lif and compare management route with data network path; these isolate why successful cluster admin ping is treated as proof nfs data access works. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is diagnose management-lif reachability separately from client data-lif access. Expert review has not yet confirmed option exclusivity.
Question 646
Fictional NetApp hardware-support incident R376-C162: A technician moves a data LIF to an isolated management network to fix user traffic. What record best distinguishes this suspected issue from a nearby hardware fault?
- Check ONTAP LUN map and igroup membership
- Identify service policy and home port of each LIF
- Check share and file ACLs
- Check broadcast domain membership
Explanation
Correct Answer
B:Identify service policy and home port of each LIF is directly relevant evidence for the management versus data lif scenario. Pair it with compare management route with data network path when both are called for to establish whether successful cluster admin ping is treated as proof nfs data access works. The support case reports A technician moves a data LIF to an isolated management network to fix user traffic.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that the intended management or data endpoint is independently reachable. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Check ONTAP LUN map and igroup membership may be appropriate for a separate lun mapping and igroup case, but is not the most discriminating check in this incident: A technician moves a data LIF to an isolated management network to fix user traffic.. The described failure is successful cluster admin ping is treated as proof nfs data access works. The targeted evidence is identify service policy and home port of each lif together with compare management route with data network path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Check share and file ACLs may be appropriate for a separate smb share and authentication case, but is not the most discriminating check in this incident: A technician moves a data LIF to an isolated management network to fix user traffic.. The described failure is successful cluster admin ping is treated as proof nfs data access works. The targeted evidence is identify service policy and home port of each lif together with compare management route with data network path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Check broadcast domain membership may be appropriate for a separate broadcast domains and ports case, but is not the most discriminating check in this incident: A technician moves a data LIF to an isolated management network to fix user traffic.. The described failure is successful cluster admin ping is treated as proof nfs data access works. The targeted evidence is identify service policy and home port of each lif together with compare management route with data network path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 647
Fictional NetApp hardware-support incident R376-C162: A technician moves a data LIF to an isolated management network to fix user traffic. What is the principal engineering fault indicated by the scenario?
- An authentication or ACL rejection is treated as a failed disk
- A LUN is healthy in storage but invisible due to missing host mapping
- Successful cluster admin ping is treated as proof NFS data access works
- Cluster traffic is connected through the client data path or wrong VLAN
Explanation
Correct Answer
C:Successful cluster admin ping is treated as proof NFS data access works. This diagnosis fits the original incident, A technician moves a data LIF to an isolated management network to fix user traffic., rather than requiring an unrelated service action. Check identify service policy and home port of each lif and compare management route with data network path to confirm the location and status of the affected resource. The relevant corrective response is diagnose management-lif reachability separately from client data-lif access, with final acceptance when the intended management or data endpoint is independently reachable. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:An authentication or ACL rejection is treated as a failed disk describes a possible failure in the neighboring topic SMB share and authentication, not the main mechanism demonstrated here. The actual scenario is A technician moves a data LIF to an isolated management network to fix user traffic.; the more direct diagnosis is successful cluster admin ping is treated as proof nfs data access works. Confirm it from identify service policy and home port of each lif and compare management route with data network path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:A LUN is healthy in storage but invisible due to missing host mapping describes a possible failure in the neighboring topic LUN mapping and igroup, not the main mechanism demonstrated here. The actual scenario is A technician moves a data LIF to an isolated management network to fix user traffic.; the more direct diagnosis is successful cluster admin ping is treated as proof nfs data access works. Confirm it from identify service policy and home port of each lif and compare management route with data network path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:Cluster traffic is connected through the client data path or wrong VLAN describes a possible failure in the neighboring topic Cluster network isolation, not the main mechanism demonstrated here. The actual scenario is A technician moves a data LIF to an isolated management network to fix user traffic.; the more direct diagnosis is successful cluster admin ping is treated as proof nfs data access works. Confirm it from identify service policy and home port of each lif and compare management route with data network path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 648
Fictional NetApp hardware-support incident R376-C162: A technician moves a data LIF to an isolated management network to fix user traffic. Which post-service observation best demonstrates the specific problem is resolved?
- LIF target ports share actual reachable connectivity
- The authorized identity reaches the correct SMB share
- Only intended host initiators can access the mapped LUN
- The intended management or data endpoint is independently reachable
Explanation
Correct Answer
D:The intended management or data endpoint is independently reachable. This outcome would specifically test whether successful cluster admin ping is treated as proof nfs data access works has been corrected in the fictional situation: A technician moves a data LIF to an isolated management network to fix user traffic.. It should follow the supported response diagnose management-lif reachability separately from client data-lif access, with evidence from identify service policy and home port of each lif and compare management route with data network path. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:LIF target ports share actual reachable connectivity could be a positive validation for the adjacent topic Broadcast domains and ports, but is insufficient to close this fault. The case reports A technician moves a data LIF to an isolated management network to fix user traffic.. Its direct acceptance condition is that the intended management or data endpoint is independently reachable, after the appropriate action diagnose management-lif reachability separately from client data-lif access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:The authorized identity reaches the correct SMB share could be a positive validation for the adjacent topic SMB share and authentication, but is insufficient to close this fault. The case reports A technician moves a data LIF to an isolated management network to fix user traffic.. Its direct acceptance condition is that the intended management or data endpoint is independently reachable, after the appropriate action diagnose management-lif reachability separately from client data-lif access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Only intended host initiators can access the mapped LUN could be a positive validation for the adjacent topic LUN mapping and igroup, but is insufficient to close this fault. The case reports A technician moves a data LIF to an isolated management network to fix user traffic.. Its direct acceptance condition is that the intended management or data endpoint is independently reachable, after the appropriate action diagnose management-lif reachability separately from client data-lif access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 649
Fictional NetApp hardware-support incident R376-C163: A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance. Which supported next step addresses the diagnosed fault while preserving the healthy parts of the system?
- Verify failover group, policies and current home-node port when clients lose access after link change
- Preserve dedicated cluster interconnect health and port roles during switch or adapter changes
- Verify SAN LUN mapping to correct igroup initiators and host visibility
- Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health
Explanation
Correct Answer
A:Verify failover group, policies and current home-node port when clients lose access after link change. This is the targeted supported response because a lif migrates to a port without access to required client vlan. The fictional incident is: A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. The technician should first correlate check lif current port versus home port with inspect allowed failover targets and network reachability, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that data lif fails over only to reachable authorized paths. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Preserve dedicated cluster interconnect health and port roles during switch or adapter changes is a legitimate focus when investigating Cluster network isolation, but it does not resolve the reported lif failover and home port failure. In this particular incident, A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. The decisive checks are check lif current port versus home port and inspect allowed failover targets and network reachability; these isolate why a lif migrates to a port without access to required client vlan. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify failover group, policies and current home-node port when clients lose access after link change. Expert review has not yet confirmed option exclusivity.
C:Verify SAN LUN mapping to correct igroup initiators and host visibility is a legitimate focus when investigating LUN mapping and igroup, but it does not resolve the reported lif failover and home port failure. In this particular incident, A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. The decisive checks are check lif current port versus home port and inspect allowed failover targets and network reachability; these isolate why a lif migrates to a port without access to required client vlan. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify failover group, policies and current home-node port when clients lose access after link change. Expert review has not yet confirmed option exclusivity.
D:Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health is a legitimate focus when investigating SMB share and authentication, but it does not resolve the reported lif failover and home port failure. In this particular incident, A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. The decisive checks are check lif current port versus home port and inspect allowed failover targets and network reachability; these isolate why a lif migrates to a port without access to required client vlan. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify failover group, policies and current home-node port when clients lose access after link change. Expert review has not yet confirmed option exclusivity.
Question 650
Fictional NetApp hardware-support incident R376-C163: A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance. What record best distinguishes this suspected issue from a nearby hardware fault?
- Check broadcast domain membership
- Check LIF current port versus home port
- Identify service policy and home port of each LIF
- Check ONTAP LUN map and igroup membership
Explanation
Correct Answer
B:Check LIF current port versus home port is directly relevant evidence for the lif failover and home port scenario. Pair it with inspect allowed failover targets and network reachability when both are called for to establish whether a lif migrates to a port without access to required client vlan. The support case reports A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that data lif fails over only to reachable authorized paths. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Check broadcast domain membership may be appropriate for a separate broadcast domains and ports case, but is not the most discriminating check in this incident: A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. The described failure is a lif migrates to a port without access to required client vlan. The targeted evidence is check lif current port versus home port together with inspect allowed failover targets and network reachability, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Identify service policy and home port of each LIF may be appropriate for a separate management versus data lif case, but is not the most discriminating check in this incident: A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. The described failure is a lif migrates to a port without access to required client vlan. The targeted evidence is check lif current port versus home port together with inspect allowed failover targets and network reachability, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Check ONTAP LUN map and igroup membership may be appropriate for a separate lun mapping and igroup case, but is not the most discriminating check in this incident: A NAS LIF relocates onto a switch with no matching VLAN during controller maintenance.. The described failure is a lif migrates to a port without access to required client vlan. The targeted evidence is check lif current port versus home port together with inspect allowed failover targets and network reachability, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.