Question 180
Fictional NetApp hardware-support incident R376-C045: A PSU alarm persists because its PDU circuit is tripped while the supply itself passes checks. Which post-service observation best demonstrates the specific problem is resolved?
- Port roles and required network connections are restored consistently
- Recovery proceeds within the supported mode and returns to service
- Correct failed feed or PSU is repaired without losing both power sources
- Authorized support can reach the management processor without disturbing data traffic
Explanation
Correct Answer
C:Correct failed feed or PSU is repaired without losing both power sources. This outcome would specifically test whether one absent input is assumed to prove a physically failed psu has been corrected in the fictional situation: A PSU alarm persists because its PDU circuit is tripped while the supply itself passes checks.. It should follow the supported response distinguish failed input feed, power cord and psu unit using hardware status before swapping, with evidence from check pdu output and power supply status and verify separate redundant supply is functioning. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Port roles and required network connections are restored consistently could be a positive validation for the adjacent topic Adapter port mapping after FRU, but is insufficient to close this fault. The case reports A PSU alarm persists because its PDU circuit is tripped while the supply itself passes checks.. Its direct acceptance condition is that correct failed feed or psu is repaired without losing both power sources, after the appropriate action distinguish failed input feed, power cord and psu unit using hardware status before swapping. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Recovery proceeds within the supported mode and returns to service could be a positive validation for the adjacent topic Maintenance and boot modes, but is insufficient to close this fault. The case reports A PSU alarm persists because its PDU circuit is tripped while the supply itself passes checks.. Its direct acceptance condition is that correct failed feed or psu is repaired without losing both power sources, after the appropriate action distinguish failed input feed, power cord and psu unit using hardware status before swapping. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
D:Authorized support can reach the management processor without disturbing data traffic could be a positive validation for the adjacent topic BMC or Service Processor access, but is insufficient to close this fault. The case reports A PSU alarm persists because its PDU circuit is tripped while the supply itself passes checks.. Its direct acceptance condition is that correct failed feed or psu is repaired without losing both power sources, after the appropriate action distinguish failed input feed, power cord and psu unit using hardware status before swapping. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 181
Fictional NetApp hardware-support incident R376-C046: A replacement PSU is requested despite the power cord being unplugged at the rack inlet. Which plan most directly resolves the identified hardware-support risk?
- Determine the exact slot, service role and live-replacement support for an I/O card under current platform/ONTAP constraints
- Cross-check physical LEDs with current ONTAP health data rather than relying on lamp color alone
- Reconcile physical port identifiers and logical network configuration following an approved adapter replacement
- Distinguish failed input feed, power cord and PSU unit using hardware status before swapping
Explanation
Correct Answer
D:Distinguish failed input feed, power cord and PSU unit using hardware status before swapping. This is the targeted supported response because one absent input is assumed to prove a physically failed psu. The fictional incident is: A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. The technician should first correlate check pdu output and power supply status with verify separate redundant supply is functioning, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that correct failed feed or psu is repaired without losing both power sources. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
A:Determine the exact slot, service role and live-replacement support for an I/O card under current platform/ONTAP constraints is a legitimate focus when investigating I/O module replacement prerequisites, but it does not resolve the reported psu fault isolation failure. In this particular incident, A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. The decisive checks are check pdu output and power supply status and verify separate redundant supply is functioning; these isolate why one absent input is assumed to prove a physically failed psu. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is distinguish failed input feed, power cord and psu unit using hardware status before swapping. Expert review has not yet confirmed option exclusivity.
B:Cross-check physical LEDs with current ONTAP health data rather than relying on lamp color alone is a legitimate focus when investigating LED versus software-alert reconciliation, but it does not resolve the reported psu fault isolation failure. In this particular incident, A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. The decisive checks are check pdu output and power supply status and verify separate redundant supply is functioning; these isolate why one absent input is assumed to prove a physically failed psu. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is distinguish failed input feed, power cord and psu unit using hardware status before swapping. Expert review has not yet confirmed option exclusivity.
C:Reconcile physical port identifiers and logical network configuration following an approved adapter replacement is a legitimate focus when investigating Adapter port mapping after FRU, but it does not resolve the reported psu fault isolation failure. In this particular incident, A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. The decisive checks are check pdu output and power supply status and verify separate redundant supply is functioning; these isolate why one absent input is assumed to prove a physically failed psu. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is distinguish failed input feed, power cord and psu unit using hardware status before swapping. Expert review has not yet confirmed option exclusivity.
Question 182
Fictional NetApp hardware-support incident R376-C046: A replacement PSU is requested despite the power cord being unplugged at the rack inlet. Select TWO checks that together would verify the reported failure before remediation.
- Compare port inventory before and after replacement
- Check PDU output and power supply status
- Compare fan tachometer alerts with chassis thermal readings
- Verify separate redundant supply is functioning
- Map affected I/O ports to cluster HA storage or client functions
Explanation
Correct Answers
B:Check PDU output and power supply status is directly relevant evidence for the psu fault isolation scenario. Pair it with verify separate redundant supply is functioning when both are called for to establish whether one absent input is assumed to prove a physically failed psu. The support case reports A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that correct failed feed or psu is repaired without losing both power sources. This is an author-intended diagnostic choice requiring human technical confirmation.
D:Verify separate redundant supply is functioning is directly relevant evidence for the psu fault isolation scenario. Pair it with check pdu output and power supply status when both are called for to establish whether one absent input is assumed to prove a physically failed psu. The support case reports A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that correct failed feed or psu is repaired without losing both power sources. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Compare port inventory before and after replacement may be appropriate for a separate adapter port mapping after fru case, but is not the most discriminating check in this incident: A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. The described failure is one absent input is assumed to prove a physically failed psu. The targeted evidence is check pdu output and power supply status together with verify separate redundant supply is functioning, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Compare fan tachometer alerts with chassis thermal readings may be appropriate for a separate fan fru and thermal telemetry case, but is not the most discriminating check in this incident: A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. The described failure is one absent input is assumed to prove a physically failed psu. The targeted evidence is check pdu output and power supply status together with verify separate redundant supply is functioning, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
E:Map affected I/O ports to cluster HA storage or client functions may be appropriate for a separate i/o module replacement prerequisites case, but is not the most discriminating check in this incident: A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. The described failure is one absent input is assumed to prove a physically failed psu. The targeted evidence is check pdu output and power supply status together with verify separate redundant supply is functioning, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 183
Fictional NetApp hardware-support incident R376-C046: A replacement PSU is requested despite the power cord being unplugged at the rack inlet. What assumption should the engineer reject before touching equipment?
- One absent input is assumed to prove a physically failed PSU
- A controller is power-cycled repeatedly without preserving the first failure evidence
- A cooling failure is masked by adjusting unrelated performance settings
- In-band storage-client connectivity is mistaken for guaranteed out-of-band access
Explanation
Correct Answer
A:One absent input is assumed to prove a physically failed PSU. This diagnosis fits the original incident, A replacement PSU is requested despite the power cord being unplugged at the rack inlet., rather than requiring an unrelated service action. Check check pdu output and power supply status and verify separate redundant supply is functioning to confirm the location and status of the affected resource. The relevant corrective response is distinguish failed input feed, power cord and psu unit using hardware status before swapping, with final acceptance when correct failed feed or psu is repaired without losing both power sources. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
B:A controller is power-cycled repeatedly without preserving the first failure evidence describes a possible failure in the neighboring topic Console capture at startup, not the main mechanism demonstrated here. The actual scenario is A replacement PSU is requested despite the power cord being unplugged at the rack inlet.; the more direct diagnosis is one absent input is assumed to prove a physically failed psu. Confirm it from check pdu output and power supply status and verify separate redundant supply is functioning before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
C:A cooling failure is masked by adjusting unrelated performance settings describes a possible failure in the neighboring topic Fan FRU and thermal telemetry, not the main mechanism demonstrated here. The actual scenario is A replacement PSU is requested despite the power cord being unplugged at the rack inlet.; the more direct diagnosis is one absent input is assumed to prove a physically failed psu. Confirm it from check pdu output and power supply status and verify separate redundant supply is functioning before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:In-band storage-client connectivity is mistaken for guaranteed out-of-band access describes a possible failure in the neighboring topic BMC or Service Processor access, not the main mechanism demonstrated here. The actual scenario is A replacement PSU is requested despite the power cord being unplugged at the rack inlet.; the more direct diagnosis is one absent input is assumed to prove a physically failed psu. Confirm it from check pdu output and power supply status and verify separate redundant supply is functioning before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 184
Fictional NetApp hardware-support incident R376-C046: A replacement PSU is requested despite the power cord being unplugged at the rack inlet. Which test result best shows restoration of the intended protected behavior?
- Recovery proceeds within the supported mode and returns to service
- Correct failed feed or PSU is repaired without losing both power sources
- Affected paths and FRU are handled with the correct supported disruption plan
- Hardware and software evidence agree on exact serviced component
Explanation
Correct Answer
B:Correct failed feed or PSU is repaired without losing both power sources. This outcome would specifically test whether one absent input is assumed to prove a physically failed psu has been corrected in the fictional situation: A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. It should follow the supported response distinguish failed input feed, power cord and psu unit using hardware status before swapping, with evidence from check pdu output and power supply status and verify separate redundant supply is functioning. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Recovery proceeds within the supported mode and returns to service could be a positive validation for the adjacent topic Maintenance and boot modes, but is insufficient to close this fault. The case reports A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. Its direct acceptance condition is that correct failed feed or psu is repaired without losing both power sources, after the appropriate action distinguish failed input feed, power cord and psu unit using hardware status before swapping. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Affected paths and FRU are handled with the correct supported disruption plan could be a positive validation for the adjacent topic I/O module replacement prerequisites, but is insufficient to close this fault. The case reports A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. Its direct acceptance condition is that correct failed feed or psu is repaired without losing both power sources, after the appropriate action distinguish failed input feed, power cord and psu unit using hardware status before swapping. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
D:Hardware and software evidence agree on exact serviced component could be a positive validation for the adjacent topic LED versus software-alert reconciliation, but is insufficient to close this fault. The case reports A replacement PSU is requested despite the power cord being unplugged at the rack inlet.. Its direct acceptance condition is that correct failed feed or psu is repaired without losing both power sources, after the appropriate action distinguish failed input feed, power cord and psu unit using hardware status before swapping. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 185
Fictional NetApp hardware-support incident R376-C047: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap. Which approved diagnostic or corrective step should be selected first?
- Distinguish boot-loader, maintenance and normal ONTAP modes before issuing any service command
- Distinguish failed input feed, power cord and PSU unit using hardware status before swapping
- Confirm fan module position and temperature trends before deciding the safe field exchange
- Cross-check physical LEDs with current ONTAP health data rather than relying on lamp color alone
Explanation
Correct Answer
C:Confirm fan module position and temperature trends before deciding the safe field exchange. This is the targeted supported response because a cooling failure is masked by adjusting unrelated performance settings. The fictional incident is: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. The technician should first correlate compare fan tachometer alerts with chassis thermal readings with verify approved fan module procedure and airflow clearance, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that cooling redundancy and operating temperatures return to supported limits. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
A:Distinguish boot-loader, maintenance and normal ONTAP modes before issuing any service command is a legitimate focus when investigating Maintenance and boot modes, but it does not resolve the reported fan fru and thermal telemetry failure. In this particular incident, A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. The decisive checks are compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance; these isolate why a cooling failure is masked by adjusting unrelated performance settings. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm fan module position and temperature trends before deciding the safe field exchange. Expert review has not yet confirmed option exclusivity.
B:Distinguish failed input feed, power cord and PSU unit using hardware status before swapping is a legitimate focus when investigating PSU fault isolation, but it does not resolve the reported fan fru and thermal telemetry failure. In this particular incident, A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. The decisive checks are compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance; these isolate why a cooling failure is masked by adjusting unrelated performance settings. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm fan module position and temperature trends before deciding the safe field exchange. Expert review has not yet confirmed option exclusivity.
D:Cross-check physical LEDs with current ONTAP health data rather than relying on lamp color alone is a legitimate focus when investigating LED versus software-alert reconciliation, but it does not resolve the reported fan fru and thermal telemetry failure. In this particular incident, A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. The decisive checks are compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance; these isolate why a cooling failure is masked by adjusting unrelated performance settings. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm fan module position and temperature trends before deciding the safe field exchange. Expert review has not yet confirmed option exclusivity.
Question 186
Fictional NetApp hardware-support incident R376-C047: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap. Which TWO records or observations most directly support a precise diagnosis?
- Compare fan tachometer alerts with chassis thermal readings
- Record POST and boot loader output with timestamps
- Correlate hardware error signatures with chassis slot inventory
- Verify approved fan module procedure and airflow clearance
- Map affected I/O ports to cluster HA storage or client functions
Explanation
Correct Answers
A:Compare fan tachometer alerts with chassis thermal readings is directly relevant evidence for the fan fru and thermal telemetry scenario. Pair it with verify approved fan module procedure and airflow clearance when both are called for to establish whether a cooling failure is masked by adjusting unrelated performance settings. The support case reports A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that cooling redundancy and operating temperatures return to supported limits. This is an author-intended diagnostic choice requiring human technical confirmation.
D:Verify approved fan module procedure and airflow clearance is directly relevant evidence for the fan fru and thermal telemetry scenario. Pair it with compare fan tachometer alerts with chassis thermal readings when both are called for to establish whether a cooling failure is masked by adjusting unrelated performance settings. The support case reports A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that cooling redundancy and operating temperatures return to supported limits. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
B:Record POST and boot loader output with timestamps may be appropriate for a separate console capture at startup case, but is not the most discriminating check in this incident: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. The described failure is a cooling failure is masked by adjusting unrelated performance settings. The targeted evidence is compare fan tachometer alerts with chassis thermal readings together with verify approved fan module procedure and airflow clearance, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Correlate hardware error signatures with chassis slot inventory may be appropriate for a separate chassis and midplane escalation case, but is not the most discriminating check in this incident: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. The described failure is a cooling failure is masked by adjusting unrelated performance settings. The targeted evidence is compare fan tachometer alerts with chassis thermal readings together with verify approved fan module procedure and airflow clearance, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
E:Map affected I/O ports to cluster HA storage or client functions may be appropriate for a separate i/o module replacement prerequisites case, but is not the most discriminating check in this incident: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. The described failure is a cooling failure is masked by adjusting unrelated performance settings. The targeted evidence is compare fan tachometer alerts with chassis thermal readings together with verify approved fan module procedure and airflow clearance, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 187
Fictional NetApp hardware-support incident R376-C047: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap. Which underlying failure mechanism most directly explains the documented symptoms?
- Successful POST is mistaken for complete workload restoration
- A replacement restores hardware but moves data traffic to the wrong port
- An ONTAP CLI instruction is entered at a firmware prompt or vice versa
- A cooling failure is masked by adjusting unrelated performance settings
Explanation
Correct Answer
D:A cooling failure is masked by adjusting unrelated performance settings. This diagnosis fits the original incident, A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap., rather than requiring an unrelated service action. Check compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance to confirm the location and status of the affected resource. The relevant corrective response is confirm fan module position and temperature trends before deciding the safe field exchange, with final acceptance when cooling redundancy and operating temperatures return to supported limits. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:Successful POST is mistaken for complete workload restoration describes a possible failure in the neighboring topic Post-controller replacement validation, not the main mechanism demonstrated here. The actual scenario is A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.; the more direct diagnosis is a cooling failure is masked by adjusting unrelated performance settings. Confirm it from compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:A replacement restores hardware but moves data traffic to the wrong port describes a possible failure in the neighboring topic Adapter port mapping after FRU, not the main mechanism demonstrated here. The actual scenario is A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.; the more direct diagnosis is a cooling failure is masked by adjusting unrelated performance settings. Confirm it from compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
C:An ONTAP CLI instruction is entered at a firmware prompt or vice versa describes a possible failure in the neighboring topic Maintenance and boot modes, not the main mechanism demonstrated here. The actual scenario is A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.; the more direct diagnosis is a cooling failure is masked by adjusting unrelated performance settings. Confirm it from compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 188
Fictional NetApp hardware-support incident R376-C047: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap. What measurable acceptance condition should the reviewer require after corrective work?
- Cooling redundancy and operating temperatures return to supported limits
- Support can distinguish POST, boot media and ONTAP startup faults
- Hardware and software evidence agree on exact serviced component
- Correct failed feed or PSU is repaired without losing both power sources
Explanation
Correct Answer
A:Cooling redundancy and operating temperatures return to supported limits. This outcome would specifically test whether a cooling failure is masked by adjusting unrelated performance settings has been corrected in the fictional situation: A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. It should follow the supported response confirm fan module position and temperature trends before deciding the safe field exchange, with evidence from compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
B:Support can distinguish POST, boot media and ONTAP startup faults could be a positive validation for the adjacent topic Console capture at startup, but is insufficient to close this fault. The case reports A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. Its direct acceptance condition is that cooling redundancy and operating temperatures return to supported limits, after the appropriate action confirm fan module position and temperature trends before deciding the safe field exchange. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Hardware and software evidence agree on exact serviced component could be a positive validation for the adjacent topic LED versus software-alert reconciliation, but is insufficient to close this fault. The case reports A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. Its direct acceptance condition is that cooling redundancy and operating temperatures return to supported limits, after the appropriate action confirm fan module position and temperature trends before deciding the safe field exchange. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
D:Correct failed feed or PSU is repaired without losing both power sources could be a positive validation for the adjacent topic PSU fault isolation, but is insufficient to close this fault. The case reports A chassis reports fan-2 stalled as inlet temperature climbs but a technician plans a network cable swap.. Its direct acceptance condition is that cooling redundancy and operating temperatures return to supported limits, after the appropriate action confirm fan module position and temperature trends before deciding the safe field exchange. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 189
Fictional NetApp hardware-support incident R376-C048: A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path. Which supported next step addresses the diagnosed fault while preserving the healthy parts of the system?
- Distinguish failed input feed, power cord and PSU unit using hardware status before swapping
- Confirm fan module position and temperature trends before deciding the safe field exchange
- Distinguish boot-loader, maintenance and normal ONTAP modes before issuing any service command
- Reconcile physical port identifiers and logical network configuration following an approved adapter replacement
Explanation
Correct Answer
B:Confirm fan module position and temperature trends before deciding the safe field exchange. This is the targeted supported response because a cooling failure is masked by adjusting unrelated performance settings. The fictional incident is: A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. The technician should first correlate compare fan tachometer alerts with chassis thermal readings with verify approved fan module procedure and airflow clearance, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that cooling redundancy and operating temperatures return to supported limits. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
A:Distinguish failed input feed, power cord and PSU unit using hardware status before swapping is a legitimate focus when investigating PSU fault isolation, but it does not resolve the reported fan fru and thermal telemetry failure. In this particular incident, A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. The decisive checks are compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance; these isolate why a cooling failure is masked by adjusting unrelated performance settings. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm fan module position and temperature trends before deciding the safe field exchange. Expert review has not yet confirmed option exclusivity.
C:Distinguish boot-loader, maintenance and normal ONTAP modes before issuing any service command is a legitimate focus when investigating Maintenance and boot modes, but it does not resolve the reported fan fru and thermal telemetry failure. In this particular incident, A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. The decisive checks are compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance; these isolate why a cooling failure is masked by adjusting unrelated performance settings. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm fan module position and temperature trends before deciding the safe field exchange. Expert review has not yet confirmed option exclusivity.
D:Reconcile physical port identifiers and logical network configuration following an approved adapter replacement is a legitimate focus when investigating Adapter port mapping after FRU, but it does not resolve the reported fan fru and thermal telemetry failure. In this particular incident, A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. The decisive checks are compare fan tachometer alerts with chassis thermal readings and verify approved fan module procedure and airflow clearance; these isolate why a cooling failure is masked by adjusting unrelated performance settings. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm fan module position and temperature trends before deciding the safe field exchange. Expert review has not yet confirmed option exclusivity.
Question 190
Fictional NetApp hardware-support incident R376-C048: A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path. Which TWO records or observations most directly support a precise diagnosis?
- Check PDU output and power supply status
- Check partner giveback, boot health and node state
- Record POST and boot loader output with timestamps
- Compare fan tachometer alerts with chassis thermal readings
- Verify approved fan module procedure and airflow clearance
Explanation
Correct Answers
D:Compare fan tachometer alerts with chassis thermal readings is directly relevant evidence for the fan fru and thermal telemetry scenario. Pair it with verify approved fan module procedure and airflow clearance when both are called for to establish whether a cooling failure is masked by adjusting unrelated performance settings. The support case reports A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that cooling redundancy and operating temperatures return to supported limits. This is an author-intended diagnostic choice requiring human technical confirmation.
E:Verify approved fan module procedure and airflow clearance is directly relevant evidence for the fan fru and thermal telemetry scenario. Pair it with compare fan tachometer alerts with chassis thermal readings when both are called for to establish whether a cooling failure is masked by adjusting unrelated performance settings. The support case reports A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that cooling redundancy and operating temperatures return to supported limits. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Check PDU output and power supply status may be appropriate for a separate psu fault isolation case, but is not the most discriminating check in this incident: A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. The described failure is a cooling failure is masked by adjusting unrelated performance settings. The targeted evidence is compare fan tachometer alerts with chassis thermal readings together with verify approved fan module procedure and airflow clearance, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
B:Check partner giveback, boot health and node state may be appropriate for a separate post-controller replacement validation case, but is not the most discriminating check in this incident: A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. The described failure is a cooling failure is masked by adjusting unrelated performance settings. The targeted evidence is compare fan tachometer alerts with chassis thermal readings together with verify approved fan module procedure and airflow clearance, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Record POST and boot loader output with timestamps may be appropriate for a separate console capture at startup case, but is not the most discriminating check in this incident: A shelf fan alarm follows a blocked rear exhaust and nobody checks the airflow path.. The described failure is a cooling failure is masked by adjusting unrelated performance settings. The targeted evidence is compare fan tachometer alerts with chassis thermal readings together with verify approved fan module procedure and airflow clearance, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.