Question 350
A four-node S2D deployment has uneven storage performance because half the hosts use mismatched RDMA-capable network adapters. Which observed result BEST demonstrates that the intended outcome has been achieved?
Explanation
Correct Answer
S2D storage traffic uses intended resilient paths with predictable performance and failover, avoiding unapproved management exposure on storage adapters. This is an observable acceptance condition, not merely evidence that a feature was enabled. Network ATC automates consistent host network intent where supported but cannot compensate for mismatched NIC hardware, unsuitable switch configuration, or unavailable RDMA support. Situation: A four-node S2D deployment has uneven storage performance because half the hosts use mismatched RDMA-capable network adapters.
Incorrect Answers
The failed node re-enters service without overwriting resource ownership or forcing two active writers, and clients use the surviving owner while repairs occur. This tests Drain roles and recover failed cluster nodes, but does not demonstrate that the requested outcome is satisfied. The relevant acceptance test is: S2D storage traffic uses intended resilient paths with predictable performance and failover, avoiding unapproved management exposure on storage adapters. Situation: A four-node S2D deployment has uneven storage performance because half the hosts use mismatched RDMA-capable network adapters.
Each node receives required updates and rejoins healthy while application roles remain available within accepted interruption budgets. This tests Cluster-Aware Updating and maintenance orchestration, but does not demonstrate that the requested outcome is satisfied. The relevant acceptance test is: S2D storage traffic uses intended resilient paths with predictable performance and failover, avoiding unapproved management exposure on storage adapters. Situation: A four-node S2D deployment has uneven storage performance because half the hosts use mismatched RDMA-capable network adapters.
A failed disk is replaced and data repair completes with virtual disks healthy and documented resilience against the next expected fault. This tests S2D storage pool repair and capacity planning, but does not demonstrate that the requested outcome is satisfied. The relevant acceptance test is: S2D storage traffic uses intended resilient paths with predictable performance and failover, avoiding unapproved management exposure on storage adapters. Situation: A four-node S2D deployment has uneven storage performance because half the hosts use mismatched RDMA-capable network adapters.


