A migration moves a VM into a rack with a different access VLAN tag, but the logical overlay must preserve the original tenant broadcast domain. A peer engineer challenges the proposed fix and asks for the underlying mechanism. Which technical explanation most accurately accounts for the observed behavior and the requirement for the correction?
- Head-end replication copies BUM frames to known remote VTEPs; an incomplete membership list selectively blackholes discovery traffic.
- A VLAN tag is local to a switching domain, whereas a VNI identifies the overlay segment; the mapping must be explicit and consistent with policy.
- The Ethernet and VXLAN/IP/UDP headers consume transport bytes; adding a tunnel can exceed a previously sufficient physical MTU.
- VTEPs encapsulate and decapsulate overlay frames; the routed spine underlay normally forwards only outer IP packets.
Explanation
Correct Answer
B:A VLAN tag is local to a switching domain, whereas a VNI identifies the overlay segment; the mapping must be explicit and consistent with policy. A suitable diagnostic is to inspect access-port VLAN membership and each local VLAN-to-common-VNI mapping. The narrowly scoped remediation is to map each site's correct local VLAN to the authorized common VNI and verify the access side independently. A peer engineer challenges the proposed fix and asks for the underlying mechanism.
Incorrect Answers
A:Head-end replication copies BUM frames to known remote VTEPs; an incomplete membership list selectively blackholes discovery traffic. That may help elsewhere, but it does not make the change required for vlan tag translation at overlay edge.
C:The Ethernet and VXLAN/IP/UDP headers consume transport bytes; adding a tunnel can exceed a previously sufficient physical MTU. That may help elsewhere, but it does not make the change required for vlan tag translation at overlay edge.
D:VTEPs encapsulate and decapsulate overlay frames; the routed spine underlay normally forwards only outer IP packets. That may help elsewhere, but it does not make the change required for vlan tag translation at overlay edge.
Question 451
EVPN routes show the remote MAC correctly, but its data traffic arrives at the remote VTEP without reaching the host port. The team has not approved a network change. Which diagnostic inspection most directly distinguishes the controlling configuration or forwarding dependency before any intervention?
- Measure allowed inner frame size, outer header overhead and configured MTU on each underlay hop.
- Inspect tunnel source selection, loopback addressing, underlay advertisements and the remote VTEP next-hop.
- Inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup.
- Inspect the VTEP source interface, remote tunnel destination, VNI and encapsulation counters.
Explanation
Correct Answer
C:Inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. Once the diagnosis is supported, the team can confirm the intended result: encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
Incorrect Answers
A:Measure allowed inner frame size, outer header overhead and configured MTU on each underlay hop. The Ethernet and VXLAN/IP/UDP headers consume transport bytes; adding a tunnel can exceed a previously sufficient physical MTU. The more informative check is to inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup.
B:Inspect tunnel source selection, loopback addressing, underlay advertisements and the remote VTEP next-hop. A VTEP bound to a physical link inherits that link's failure; a reachable loopback can persist as the underlay reroutes. The more informative check is to inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup.
D:Inspect the VTEP source interface, remote tunnel destination, VNI and encapsulation counters. VTEPs encapsulate and decapsulate overlay frames; the routed spine underlay normally forwards only outer IP packets. The more informative check is to inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup.
Question 452
EVPN routes show the remote MAC correctly, but its data traffic arrives at the remote VTEP without reaching the host port. The underlying fault is confirmed, and the fabric architect must choose a supportable target-state approach. Which design decision addresses the requirement without expanding unrelated tenant or infrastructure scope?
- Allocate unique VNIs to independently isolated broadcast domains under the tenant addressing policy.
- Allow the authorized VXLAN UDP transport between approved tunnel endpoints without opening general tenant services.
- Provide a bounded supported mechanism for unknown-unicast handling while minimizing excessive flooding.
- Resolve the mismatch between received VNI and the local forwarding bridge rather than treating it as an underlay outage.
Explanation
Correct Answer
D:Resolve the mismatch between received VNI and the local forwarding bridge rather than treating it as an underlay outage. The target state addresses the actual data-center dependency, not simply whether a device or BGP session appears online. An operational acceptance test should show that encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
Incorrect Answers
A:Allocate unique VNIs to independently isolated broadcast domains under the tenant addressing policy. A reused VNI can merge what should be separate Layer 2 overlay segments unless other controls explicitly isolate them. The case instead calls for the following: resolve the mismatch between received VNI and the local forwarding bridge rather than treating it as an underlay outage.
B:Allow the authorized VXLAN UDP transport between approved tunnel endpoints without opening general tenant services. Conventional VXLAN data encapsulation uses UDP destination port 4789; ordinary IP reachability tests alone do not prove the UDP tunnel can pass. The case instead calls for the following: resolve the mismatch between received VNI and the local forwarding bridge rather than treating it as an underlay outage.
C:Provide a bounded supported mechanism for unknown-unicast handling while minimizing excessive flooding. Unknown-unicast traffic requires a defined flood or learning mechanism, while known unicast should use endpoint reachability information. The case instead calls for the following: resolve the mismatch between received VNI and the local forwarding bridge rather than treating it as an underlay outage.
Question 453
EVPN routes show the remote MAC correctly, but its data traffic arrives at the remote VTEP without reaching the host port. The issue is isolated and a narrowly scoped, reversible change window has been approved. Which implementation step would most precisely correct the faulty behavior while retaining the existing control boundaries?
- Correct the local VNI-to-bridge binding or egress membership with an isolated test host.
- Correct the allowed multicast state or choose supported ingress replication for the affected segment.
- Configure the selected ingress replication or multicast behavior consistently across VTEPs in the VNI.
- Update the affected membership source or VTEP replication list and remove stale endpoints.
Explanation
Correct Answer
A:Correct the local VNI-to-bridge binding or egress membership with an isolated test host. The team should then confirm that encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
Incorrect Answers
B:Correct the allowed multicast state or choose supported ingress replication for the affected segment. Multicast transport for overlay BUM depends on group distribution in the underlay; an ordinary unicast fabric route is insufficient. It cannot substitute for the required control: correct the local VNI-to-bridge binding or egress membership with an isolated test host.
C:Configure the selected ingress replication or multicast behavior consistently across VTEPs in the VNI. Unknown-unicast traffic requires a defined flood or learning mechanism, while known unicast should use endpoint reachability information. It cannot substitute for the required control: correct the local VNI-to-bridge binding or egress membership with an isolated test host.
D:Update the affected membership source or VTEP replication list and remove stale endpoints. The required implementation instead is to correct the local VNI-to-bridge binding or egress membership with an isolated test host. It cannot substitute for the required control: correct the local VNI-to-bridge binding or egress membership with an isolated test host.
Question 454
EVPN routes show the remote MAC correctly, but its data traffic arrives at the remote VTEP without reaching the host port. The remediation has been applied in a controlled pilot. Which observed result most convincingly proves that the specific network requirement is working, beyond merely showing a healthy management dashboard?
- Broadcast discovery works across the intended failure paths with bounded multicast group membership.
- Encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
- A maximum approved inner frame passes end to end without fragmentation or an outer-MTU drop.
- The first unknown-destination packet follows the approved fallback path, and learned traffic subsequently uses the correct unicast tunnel.
Explanation
Correct Answer
B:Encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise. This is an observable outcome for tunnel decapsulation counter, not a screenshot showing only that a configuration command exists. Earlier evidence can be checked using: inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup.
Incorrect Answers
A:Broadcast discovery works across the intended failure paths with bounded multicast group membership. Such a result might prove multicast-backed bum delivery works: Multicast transport for overlay BUM depends on group distribution in the underlay; an ordinary unicast fabric route is insufficient. It addresses a different dependency from tunnel decapsulation counter.
C:A maximum approved inner frame passes end to end without fragmentation or an outer-MTU drop. Such a result might prove encapsulation mtu validation works: The Ethernet and VXLAN/IP/UDP headers consume transport bytes; adding a tunnel can exceed a previously sufficient physical MTU. It addresses a different dependency from tunnel decapsulation counter.
D:The first unknown-destination packet follows the approved fallback path, and learned traffic subsequently uses the correct unicast tunnel. Such a result might prove unknown-unicast handling works: Unknown-unicast traffic requires a defined flood or learning mechanism, while known unicast should use endpoint reachability information. It addresses a different dependency from tunnel decapsulation counter.
Question 455
EVPN routes show the remote MAC correctly, but its data traffic arrives at the remote VTEP without reaching the host port. A peer engineer challenges the proposed fix and asks for the underlying mechanism. Which technical explanation most accurately accounts for the observed behavior and the requirement for the correction?
- The Ethernet and VXLAN/IP/UDP headers consume transport bytes; adding a tunnel can exceed a previously sufficient physical MTU.
- Head-end replication copies BUM frames to known remote VTEPs; an incomplete membership list selectively blackholes discovery traffic.
- Successful tunnel receipt does not guarantee local switching; the receiving VTEP must map the VNI and destination MAC to the right bridge port.
- Multicast transport for overlay BUM depends on group distribution in the underlay; an ordinary unicast fabric route is insufficient.
Explanation
Correct Answer
C:Successful tunnel receipt does not guarantee local switching; the receiving VTEP must map the VNI and destination MAC to the right bridge port. The narrowly scoped remediation is to correct the local VNI-to-bridge binding or egress membership with an isolated test host. A suitable diagnostic is to inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup.
Incorrect Answers
A:The Ethernet and VXLAN/IP/UDP headers consume transport bytes; adding a tunnel can exceed a previously sufficient physical MTU. To distinguish the two, inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. The reported condition is about tunnel decapsulation counter, not this adjacent change.
B:Head-end replication copies BUM frames to known remote VTEPs; an incomplete membership list selectively blackholes discovery traffic. To distinguish the two, inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. The reported condition is about tunnel decapsulation counter, not this adjacent change.
D:Multicast transport for overlay BUM depends on group distribution in the underlay; an ordinary unicast fabric route is insufficient. To distinguish the two, inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. The reported condition is about tunnel decapsulation counter, not this adjacent change.
Question 456
A leaf receives VXLAN packets and increments tunnel RX counters, yet the intended local VLAN sends no frames toward the attached server. The team has not approved a network change. Which diagnostic inspection most directly distinguishes the controlling configuration or forwarding dependency before any intervention?
- Inspect access-port VLAN membership and each local VLAN-to-common-VNI mapping.
- Inspect the per-VNI flood list, learned remote VTEP membership and source of membership advertisements.
- Inspect outer tunnel source/destination routing separately from the inner tenant address and selected VNI.
- Inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup.
Explanation
Correct Answer
D:Inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. Once the diagnosis is supported, the team can confirm the intended result: encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise. A leaf receives VXLAN packets and increments tunnel RX counters, yet the intended local VLAN sends no frames toward the attached server. The team has not approved a network change.
Incorrect Answers
A:Inspect access-port VLAN membership and each local VLAN-to-common-VNI mapping. A VLAN tag is local to a switching domain, whereas a VNI identifies the overlay segment; the mapping must be explicit and consistent with policy. This is not the decisive inspection for tunnel decapsulation counter.
B:Inspect the per-VNI flood list, learned remote VTEP membership and source of membership advertisements. Head-end replication copies BUM frames to known remote VTEPs; an incomplete membership list selectively blackholes discovery traffic. This is not the decisive inspection for tunnel decapsulation counter.
C:Inspect outer tunnel source/destination routing separately from the inner tenant address and selected VNI. VXLAN carries inner tenant Ethernet traffic inside an outer IP packet; underlay forwarding uses the outer header, not the tenant's overlapping address. This is not the decisive inspection for tunnel decapsulation counter.
Question 457
A leaf receives VXLAN packets and increments tunnel RX counters, yet the intended local VLAN sends no frames toward the attached server. The underlying fault is confirmed, and the fabric architect must choose a supportable target-state approach. Which design decision addresses the requirement without expanding unrelated tenant or infrastructure scope?
- Resolve the mismatch between received VNI and the local forwarding bridge rather than treating it as an underlay outage.
- Allow the authorized VXLAN UDP transport between approved tunnel endpoints without opening general tenant services.
- Use a supported EVPN-informed or multicast-efficient BUM design suited to the fabric scale.
- Use supported multicast transport for overlay BUM only when the underlay supports the required group reachability.
Explanation
Correct Answer
A:Resolve the mismatch between received VNI and the local forwarding bridge rather than treating it as an underlay outage. The target state addresses the actual data-center dependency, not simply whether a device or BGP session appears online. An operational acceptance test should show that encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise. The underlying fault is confirmed, and the fabric architect must choose a supportable target-state approach.
Incorrect Answers
B:Allow the authorized VXLAN UDP transport between approved tunnel endpoints without opening general tenant services. Conventional VXLAN data encapsulation uses UDP destination port 4789; ordinary IP reachability tests alone do not prove the UDP tunnel can pass. That may help elsewhere, but it does not make the change required for tunnel decapsulation counter.
C:Use a supported EVPN-informed or multicast-efficient BUM design suited to the fabric scale. Replicating each BUM frame to every remote tunnel endpoint scales with VNI membership; optimized learning and replication reduce overhead. That may help elsewhere, but it does not make the change required for tunnel decapsulation counter.
D:Use supported multicast transport for overlay BUM only when the underlay supports the required group reachability. Multicast transport for overlay BUM depends on group distribution in the underlay; an ordinary unicast fabric route is insufficient. That may help elsewhere, but it does not make the change required for tunnel decapsulation counter.
Question 458
A leaf receives VXLAN packets and increments tunnel RX counters, yet the intended local VLAN sends no frames toward the attached server. The issue is isolated and a narrowly scoped, reversible change window has been approved. Which implementation step would most precisely correct the faulty behavior while retaining the existing control boundaries?
- Configure the outer VTEP reachability and per-tenant overlay mapping without exporting the inner overlap into underlay.
- Correct the local VNI-to-bridge binding or egress membership with an isolated test host.
- Increase supported link MTUs consistently or reduce permitted inner payload under change control.
- Map each site's correct local VLAN to the authorized common VNI and verify the access side independently.
Explanation
Correct Answer
B:Correct the local VNI-to-bridge binding or egress membership with an isolated test host. The team should then confirm that encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise. The issue is isolated and a narrowly scoped, reversible change window has been approved.
Incorrect Answers
A:Configure the outer VTEP reachability and per-tenant overlay mapping without exporting the inner overlap into underlay. VXLAN carries inner tenant Ethernet traffic inside an outer IP packet; underlay forwarding uses the outer header, not the tenant's overlapping address. A more direct response is to correct the local VNI-to-bridge binding or egress membership with an isolated test host.
C:Increase supported link MTUs consistently or reduce permitted inner payload under change control. The Ethernet and VXLAN/IP/UDP headers consume transport bytes; adding a tunnel can exceed a previously sufficient physical MTU. A more direct response is to correct the local VNI-to-bridge binding or egress membership with an isolated test host.
D:Map each site's correct local VLAN to the authorized common VNI and verify the access side independently. A VLAN tag is local to a switching domain, whereas a VNI identifies the overlay segment; the mapping must be explicit and consistent with policy. A more direct response is to correct the local VNI-to-bridge binding or egress membership with an isolated test host.
Question 459
A leaf receives VXLAN packets and increments tunnel RX counters, yet the intended local VLAN sends no frames toward the attached server. The remediation has been applied in a controlled pilot. Which observed result most convincingly proves that the specific network requirement is working, beyond merely showing a healthy management dashboard?
- BUM overhead remains within design limits as new VTEPs join, without losing legitimate host discovery.
- Traffic remains within each permitted tenant segment, with no learned MACs or BUM leakage between VNIs.
- Encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
- Overlay sessions and tunneled traffic survive one uplink outage without changing the VTEP identity.
Explanation
Correct Answer
C:Encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise. This is an observable outcome for tunnel decapsulation counter, not a screenshot showing only that a configuration command exists. Earlier evidence can be checked using: inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. The remediation has been applied in a controlled pilot.
Incorrect Answers
A:BUM overhead remains within design limits as new VTEPs join, without losing legitimate host discovery. However it cannot establish success for tunnel decapsulation counter. The case instead calls for the following: encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
B:Traffic remains within each permitted tenant segment, with no learned MACs or BUM leakage between VNIs. Such a result might prove duplicate vni tenant collision works: A reused VNI can merge what should be separate Layer 2 overlay segments unless other controls explicitly isolate them. The case instead calls for the following: encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
D:Overlay sessions and tunneled traffic survive one uplink outage without changing the VTEP identity. Such a result might prove vtep source-loopback stability works: A VTEP bound to a physical link inherits that link's failure; a reachable loopback can persist as the underlay reroutes. The case instead calls for the following: encapsulated ingress frames emerge on the correct tenant access interface and egress counters rise.
Question 460
A leaf receives VXLAN packets and increments tunnel RX counters, yet the intended local VLAN sends no frames toward the attached server. A peer engineer challenges the proposed fix and asks for the underlying mechanism. Which technical explanation most accurately accounts for the observed behavior and the requirement for the correction?
- Suppressing broadcast reduces noise only when another correct mechanism supplies address bindings; blind ARP dropping breaks reachability.
- A reused VNI can merge what should be separate Layer 2 overlay segments unless other controls explicitly isolate them.
- Multicast transport for overlay BUM depends on group distribution in the underlay; an ordinary unicast fabric route is insufficient.
- Successful tunnel receipt does not guarantee local switching; the receiving VTEP must map the VNI and destination MAC to the right bridge port.
Explanation
Correct Answer
D:Successful tunnel receipt does not guarantee local switching; the receiving VTEP must map the VNI and destination MAC to the right bridge port. The narrowly scoped remediation is to correct the local VNI-to-bridge binding or egress membership with an isolated test host. A suitable diagnostic is to inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. A peer engineer challenges the proposed fix and asks for the underlying mechanism.
Incorrect Answers
A:Suppressing broadcast reduces noise only when another correct mechanism supplies address bindings; blind ARP dropping breaks reachability. To distinguish the two, inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. It cannot substitute for the required control: successful tunnel receipt does not guarantee local switching; the receiving VTEP must map the VNI and destination MAC to the right bridge port.
B:A reused VNI can merge what should be separate Layer 2 overlay segments unless other controls explicitly isolate them. To distinguish the two, inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. It cannot substitute for the required control: successful tunnel receipt does not guarantee local switching; the receiving VTEP must map the VNI and destination MAC to the right bridge port.
C:Multicast transport for overlay BUM depends on group distribution in the underlay; an ordinary unicast fabric route is insufficient. To distinguish the two, inspect decapsulation state, destination VNI mapping, egress bridge membership and MAC-table lookup. It cannot substitute for the required control: successful tunnel receipt does not guarantee local switching; the receiving VTEP must map the VNI and destination MAC to the right bridge port.