Question 960

Before applying a production change, what diagnostic should the technician prioritize? A branch VSF stack reports that one member no longer participates after a stacking cable was unplugged.

  1. Review peak bandwidth, drop counters, queuing behavior and service latency under shared load.
  2. Calculate network and broadcast addresses and compare host route, ARP request and SVI IP.
  3. Check VSF topology, role/member state, stack port diagnostics and platform support.
  4. Check configured listeners, UDP ACL counters, packet traces and management service state.

Explanation

Correct Answer

C:

Check VSF topology, role/member state, stack port diagnostics and platform support. VSF groups supported switches into a coordinated virtual switching system, not a normal Ethernet LACP bundle. Next step: Restore the supported VSF stacking links and validate member state and control-plane redundancy.

Incorrect Answers

A:

Review peak bandwidth, drop counters, queuing behavior and service latency under shared load. This diagnostic addresses another network condition (A backup job saturates a campus uplink and a technician proposes policing voice media to solve file-transfer congestion.). Here inspect: Check VSF topology, role/member state, stack port diagnostics and platform support.

B:

Calculate network and broadcast addresses and compare host route, ARP request and SVI IP. This diagnostic addresses another network condition (A switch SVI is configured as 192.0.2.126/26 while a new host uses 192.0.2.130/26 and expects same-subnet ARP.). Here inspect: Check VSF topology, role/member state, stack port diagnostics and platform support.

D:

This diagnostic addresses another network condition (A test host reaches TCP port 22 of a switch but not UDP port 161 and the operator assumes successful SSH proves SNMP availability.). Here inspect: Check VSF topology, role/member state, stack port diagnostics and platform support.

Question 961

What specific operational information BEST distinguishes the cause of this issue? A rack-mounted aggregation switch overheats after installation because intake airflow is blocked by front-mounted cable trays.

  1. Compare vendor SKU, lifecycle notice, OS support matrix and service contract terms.
  2. Inspect AAA mapping, show user information, denied commands and privileged audit trail.
  3. Check intake orientation, inlet temperature, fan status and facility airflow plan.
  4. Review device group membership, inherited template, configuration diff and site service tests.

Explanation

Correct Answer

C:

Check intake orientation, inlet temperature, fan status and facility airflow plan. Switch enclosure cooling design and intake/exhaust orientation constrain reliable rack deployment. Next step: Use supported installation clearances, directional airflow and thermal monitoring for the hardware.

Incorrect Answers

A:

This diagnostic addresses another network condition (A network manager orders a discontinued switch variant after seeing its family name on an old training slide without checking current support.). Here inspect: Check intake orientation, inlet temperature, fan status and facility airflow plan.

B:

This diagnostic addresses another network condition (A support contractor can view port status through a CLI role but is denied configuration writes, and an administrator assumes the switch is faulty.). Here inspect: Check intake orientation, inlet temperature, fan status and facility airflow plan.

D:

This diagnostic addresses another network condition (A set of branch switches joins cloud management but receives an inappropriate template due to assignment to the wrong device group.). Here inspect: Check intake orientation, inlet temperature, fan status and facility airflow plan.

Question 962

What mistaken approach is MOST likely to worsen this networking fault? A switch hardening audit passes at commissioning but subsequent emergency changes reenable an insecure management protocol.

  1. Test both allowed and denied network paths after access-control changes.
  2. Check actual cable mapping before changing an LACP bundle.
  3. Mark the switch permanently compliant after a single successful installation audit.
  4. Confirm the approved gateway for traffic leaving a subnet.

Explanation

Correct Answer

C:

Mark the switch permanently compliant after a single successful installation audit. Configuration compliance is a recurring state assessment and must account for post-deployment drift. Safer action: Compare running configuration with approved baseline on a regular and event-triggered schedule.

Incorrect Answers

A:

Test both allowed and denied network paths after access-control changes. Negative tests confirm unauthorized paths remain restricted. For the stated issue, the appropriate action is: Compare running configuration with approved baseline on a regular and event-triggered schedule.

B:

Check actual cable mapping before changing an LACP bundle. Physical peer identity determines safe aggregation membership. For the stated issue, the appropriate action is: Compare running configuration with approved baseline on a regular and event-triggered schedule.

D:

Confirm the approved gateway for traffic leaving a subnet. Off-subnet forwarding depends on usable Layer 3 next hops. For the stated issue, the appropriate action is: Compare running configuration with approved baseline on a regular and event-triggered schedule.

Question 963

What fundamental switching or routing concept is MOST relevant here? A building-standard proposal requires PoE++ endpoints but a selected access series supports only lower power classes on the ordered power supply.

  1. Aruba operating system families and hardware generations can use different command interfaces and capabilities.
  2. PoE capabilities vary by model, power supply and standards compliance, not simply by physical RJ-45 count.
  3. Access bandwidth and aggregated upstream capacity are separate sizing dimensions.
  4. Logical stacking is a product-specific capability requiring compatible members and dedicated supported links.

Explanation

Correct Answer

B:

PoE capabilities vary by model, power supply and standards compliance, not simply by physical RJ-45 count. Appropriate intervention: Select a model and supply configuration whose PoE capabilities meet the highest supported endpoint demand.

Incorrect Answers

A:

This concept applies to another switch problem (A campus engineer attempts to apply an AOS-Switch-specific CLI command sequence unchanged on a device running AOS-CX.). PoE capabilities vary by model, power supply and standards compliance, not simply by physical RJ-45 count.

C:

This concept applies to another switch problem (A remote closet has forty gigabit users and a 1-Gb/s uplink saturated by backups, yet planners buy more client ports without changing aggregation.). PoE capabilities vary by model, power supply and standards compliance, not simply by physical RJ-45 count.

D:

This concept applies to another switch problem (A branch procurement plan requires one resilient managed logical switch from several chassis but selects a platform without the required VSF support.). PoE capabilities vary by model, power supply and standards compliance, not simply by physical RJ-45 count.

Question 964

Identify the unsafe shortcut to REJECT for the following campus switching situation: A switch web-management hostname fails but HTTPS works by its IP address from the same workstation.

  1. Restrict monitoring permissions to the required data access.
  2. Disable all HTTPS authentication because the browser cannot resolve the switch hostname.
  3. Review current NTP and syslog health during an incident.
  4. Confirm the approved gateway for traffic leaving a subnet.

Explanation

Correct Answer

B:

Disable all HTTPS authentication because the browser cannot resolve the switch hostname. Name resolution failures are distinct from transport/application reachability to a known IP. Safer action: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

Incorrect Answers

A:

Restrict monitoring permissions to the required data access. Read-only telemetry rarely needs broad configuration privileges. For the stated issue, the appropriate action is: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

C:

Review current NTP and syslog health during an incident. Time-aligned logs support sound fault analysis. For the stated issue, the appropriate action is: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

D:

Confirm the approved gateway for traffic leaving a subnet. Off-subnet forwarding depends on usable Layer 3 next hops. For the stated issue, the appropriate action is: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

Question 965

Which targeted correction is justified for this campus switching scenario? A server has correct IP and gateway addressing but its ARP cache repeatedly learns the wrong gateway MAC after a test device was connected.

  1. Install a reviewed default route to the valid upstream next hop where the switch is a Layer 3 router.
  2. Configure an approved trunk and corresponding server VLAN tag interfaces while retaining a planned native management VLAN.
  3. Disable unnecessary services and approve only supported management-plane protocols from known sources.
  4. Find the unauthorized ARP responder and restore the expected gateway ownership and Layer 2 segmentation.

Explanation

Correct Answer

D:

IPv4 ARP resolves an on-link next-hop MAC and can be disrupted by duplicate or spoofed responses. Verified result: ARP for the gateway maps to the intended router MAC and clients pass the same-subnet reachability test.

Incorrect Answers

A:

This change serves a different network condition (A local VLAN can reach its own gateway but cannot reach outside prefixes because the core routing table lacks a default path.), not the issue described. Appropriate response here: Find the unauthorized ARP responder and restore the expected gateway ownership and Layer 2 segmentation.

B:

This change serves a different network condition (A virtualization host tags its guest networks but the switchport is configured as a single untagged access port.), not the issue described. Appropriate response here: Find the unauthorized ARP responder and restore the expected gateway ownership and Layer 2 segmentation.

C:

This change serves a different network condition (A new AOS-CX switch accepts remote management protocols never requested in the commissioning standard.), not the issue described. Appropriate response here: Find the unauthorized ARP responder and restore the expected gateway ownership and Layer 2 segmentation.

Question 966

An HPE Aruba Networking switch operator observes this condition: An AOS-CX security notice names a vulnerable release, but the team lacks an inventory tying installed versions to affected devices. What action BEST addresses the fault?

  1. Forward appropriate switch logs to protected central collectors with time synchronization and retention policy.
  2. Provision supported SNMPv3 users with scoped authentication/privacy and protected secret distribution.
  3. Protect, encrypt and scope configuration backups while minimizing embedded secrets and applying retention controls.
  4. Maintain software/version inventory, determine applicability and create risk-based supported patch plans.

Explanation

Correct Answer

D:

Maintain software/version inventory, determine applicability and create risk-based supported patch plans. Lifecycle management must connect official advisories to actual deployed product versions and exposures. Verified result: Affected switches are identified correctly and remediated or have documented interim risk controls.

Incorrect Answers

A:

This change serves a different network condition (A branch switch reboots unexpectedly and loses volatile local fault history, leaving no evidence of the preceding issue.), not the issue described. Appropriate response here: Maintain software/version inventory, determine applicability and create risk-based supported patch plans.

B:

This change serves a different network condition (A monitoring deployment reuses one SNMPv2 community across all switches while compliance requires authenticated confidential device telemetry.), not the issue described. Appropriate response here: Maintain software/version inventory, determine applicability and create risk-based supported patch plans.

C:

This change serves a different network condition (Switch configuration archives contain read-only SNMP strings and local account hashes in a shared team folder.), not the issue described. Appropriate response here: Maintain software/version inventory, determine applicability and create risk-based supported patch plans.

Question 967

What specific operational information BEST distinguishes the cause of this issue? Traffic reaches a remote printer server from a new department VLAN, but the printer server's reply follows a firewall with no path back.

  1. Inspect route tables at both endpoints, traceroute each direction and firewall drop logs.
  2. Inspect interface disabled reason, BPDU guard event, neighbor identity and local topology.
  3. Review SVI ACL counters, packet source/destination, forwarding path and approved rule order.
  4. Review MAC move events, trunk topology, STP roles and broadcast counters.

Explanation

Correct Answer

A:

Next step: Establish an approved return route and validate both forward and reverse paths.

Incorrect Answers

B:

This diagnostic addresses another network condition (A newly deployed access point cannot connect after switch security protection placed its port into a disabled state on detecting a BPDU.). Here inspect: Inspect route tables at both endpoints, traceroute each direction and firewall drop logs.

C:

This diagnostic addresses another network condition (A switch can ping a host in VLAN25 but a remote host cannot return traffic after an ACL change on the SVI.). Here inspect: Inspect route tables at both endpoints, traceroute each direction and firewall drop logs.

D:

Review MAC move events, trunk topology, STP roles and broadcast counters. This diagnostic addresses another network condition (A switch repeatedly learns one server MAC on two trunk ports while broadcast utilization rises sharply.). Here inspect: Inspect route tables at both endpoints, traceroute each direction and firewall drop logs.

Question 968

Select TWO statements: the correct intervention and its observed verification in this AOS-CX case. A fiber uplink shows intermittent packet loss and increasing CRC errors whenever temperatures rise in a poorly ventilated cabinet.

  1. Action: Correct the assigned default gateway option and confirm the current SVI routing path.
  2. Unsafe shortcut: Reconfigure OSPF costs to compensate for damaged optical receive power.
  3. Verification: Optical and interface error counters stay stable across representative temperature and traffic tests.
  4. Verification: The certified cable plant sustains negotiated speed and port flap events disappear.
  5. Action: Check supported optics, light levels, patch condition and cooling before altering routing policies.

Explanation

Correct Answers

C:

Verification: Optical and interface error counters stay stable across representative temperature and traffic tests. Physical media errors can occur despite an administratively up port and affect all higher-layer traffic.

E:

Action: Check supported optics, light levels, patch condition and cooling before altering routing policies. Physical media errors can occur despite an administratively up port and affect all higher-layer traffic.

Incorrect Answers

A:

This remedy fits a different fault (A subnet's PCs can ping each other but never reach the building printer subnet after a DHCP option points them at an old gateway.).

B:

Physical media errors can occur despite an administratively up port and affect all higher-layer traffic.

D:

This is validation for another condition (A wall outlet repeatedly flaps between operational states, but the network team replaces the switch firmware before testing the copper run.). Here verify: Optical and interface error counters stay stable across representative temperature and traffic tests.

Question 969

An AOS-CX learner investigates: After several virtual machines move hosts, traffic briefly floods an access VLAN while dynamic MAC entries are relearned. What underlying concept should guide the response?

  1. Attack surface reduction limits externally reachable interfaces independent of user-data forwarding.
  2. Administrative roles should separate observation from configuration authority to reduce operational risk.
  3. QoS classifies and schedules competing traffic but cannot create bandwidth beyond physical link capacity.
  4. Ethernet switches populate forwarding tables by observing frame source MACs and age dynamic entries.

Explanation

Correct Answer

D:

Ethernet switches populate forwarding tables by observing frame source MACs and age dynamic entries. Appropriate intervention: Validate source-MAC learning and transient unknown-unicast behavior rather than hardcode every destination MAC.

Incorrect Answers

A:

This concept applies to another switch problem (A new AOS-CX switch accepts remote management protocols never requested in the commissioning standard.). Ethernet switches populate forwarding tables by observing frame source MACs and age dynamic entries.

B:

This concept applies to another switch problem (A contractor needs to view interface health but receives a full switch administrator account that can erase configuration.). Ethernet switches populate forwarding tables by observing frame source MACs and age dynamic entries.

C:

This concept applies to another switch problem (A voice handset marks RTP packets with an approved DSCP but a downstream switch rewrites all traffic to best effort.). Ethernet switches populate forwarding tables by observing frame source MACs and age dynamic entries.

Question 970

Which measurable state would demonstrate the fault was resolved? An aggregation link sporadically drops packets but staff check only the logical VLAN table.

  1. CRC/error rates return to baseline after targeted media remediation under comparable traffic load.
  2. The intended selected route is present and traceroute follows the correct forwarding decision.
  3. The affected edge interface is safely restricted when switch BPDUs appear while normal hosts continue working.
  4. Show spanning-tree identifies the planned root and access uplinks assume expected port roles.

Explanation

Correct Answer

A:

CRC/error rates return to baseline after targeted media remediation under comparable traffic load. Corresponding action: Use show interface extended counters and optical or copper diagnostics to localize the physical error cause.

Incorrect Answers

B:

That observation verifies a different fault (An administrator changes a static route but does not know whether a more-specific dynamic route still determines forwarding.). For the question at hand, verify: CRC/error rates return to baseline after targeted media remediation under comparable traffic load.

C:

That observation verifies a different fault (A contractor attaches an unmanaged switch to an edge port and creates a loop after the port was configured as unprotected edge.). For the question at hand, verify: CRC/error rates return to baseline after targeted media remediation under comparable traffic load.

D:

That observation verifies a different fault (An access switch with default bridge priority becomes the RSTP root ahead of the designated distribution device.). For the question at hand, verify: CRC/error rates return to baseline after targeted media remediation under comparable traffic load.