HP HPE6-A86 Practice Test 83
Question 820
A wired network administrator encounters: A network printer has a DHCP lease from the visitor subnet because its switchport retains the visitor access VLAN. Which configuration or response is MOST appropriate?
- Trace the fault from physical link and transceiver status upward before analyzing application payloads.
- Assign its untagged access port to the approved printer VLAN, preserving the intended DHCP scope.
- Configure matching compatible LACP modes and correct member interfaces on both endpoints.
- Identify the routing boundary and configure a supported SVI or external Layer 3 gateway for the intended subnets.
Explanation
Correct Answer
B:Assign its untagged access port to the approved printer VLAN, preserving the intended DHCP scope. An access VLAN classifies untagged traffic into one configured Ethernet broadcast domain. Verified result: The printer gets a lease from the printer scope and cannot reach the restricted visitor-only service set.
Incorrect Answers
A:This change serves a different network condition (An inventory application sends correct HTTP requests, but an operator blames its Layer 7 data when the distribution uplink has no physical signal.), not the issue described. Appropriate response here: Assign its untagged access port to the approved printer VLAN, preserving the intended DHCP scope.
C:This change serves a different network condition (A pair of uplinks were bundled as dynamic LAG on one side but configured as unrelated standalone ports on the neighbor.), not the issue described. Appropriate response here: Assign its untagged access port to the approved printer VLAN, preserving the intended DHCP scope.
D:This change serves a different network condition (Two workstations share a switch yet belong to distinct IP subnets; a technician expects the switch MAC table alone to route between them.), not the issue described. Appropriate response here: Assign its untagged access port to the approved printer VLAN, preserving the intended DHCP scope.
Question 821
Following the planned correction, which outcome MOST strongly confirms success? A switch configuration change works until the next reboot because operators did not follow the supported persistence workflow.
- The VLAN policy persists after management sync and intended site-specific exception is documented.
- API and CLI inspection report coherent effective configuration and changes are auditable after a controlled update.
- After a controlled reboot, intended VLAN and interface policy remain effective and recoverable.
- Relevant link flap events are recorded and useful alerts arrive without saturating the management CPU.
Explanation
Correct Answer
C:After a controlled reboot, intended VLAN and interface policy remain effective and recoverable. Corresponding action: Use the supported configuration save and checkpoint process appropriate to the installed AOS-CX release.
Incorrect Answers
A:That observation verifies a different fault (A cloud-managed AOS-CX switch reverts a temporary local VLAN change because a centrally enforced template remains authoritative.). For the question at hand, verify: After a controlled reboot, intended VLAN and interface policy remain effective and recoverable.
B:That observation verifies a different fault (A switch operator expects a traditional one-shot text file to be the only source of structured switch state used by automation.). For the question at hand, verify: After a controlled reboot, intended VLAN and interface policy remain effective and recoverable.
D:That observation verifies a different fault (Operations wants automated alerts on abnormal link flap patterns but plans to poll all interface counters at one-second intervals from a fragile script.). For the question at hand, verify: After a controlled reboot, intended VLAN and interface policy remain effective and recoverable.
Question 822
Select THREE statements: appropriate response, causal concept, and expected verification. A new server-facing switchport remains administratively disabled after an approved cable move even though the transceiver is detected.
- Verification: The correct port reaches an up state and service traffic follows its previously approved VLAN.
- Principle: An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
- Verification: Routing contains the expected precise paths, and isolated branch networks remain individually reachable.
- Action: Enable only the intended interface and verify link and access policy before restoring server traffic.
- Unsafe shortcut: Enable every unused switchport in the closet to find the one connected to the server.
- Action: Assign reviewed spanning-tree bridge priorities on supported switches so the intended core is root.
Explanation
Correct Answers
A:Verification: The correct port reaches an up state and service traffic follows its previously approved VLAN. An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
B:Principle: An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence. This causal networking concept connects the intervention and outcome.
D:Action: Enable only the intended interface and verify link and access policy before restoring server traffic. An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
Incorrect Answers
C:This is validation for another condition (A branch advertises overlapping IP subnets via static and OSPF entries and an engineer wants a broad summary that hides a required more-specific path.). Here verify: The correct port reaches an up state and service traffic follows its previously approved VLAN.
E:An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
F:This remedy fits a different fault (An access switch with default bridge priority becomes the RSTP root ahead of the designated distribution device.).
Question 823
An engineer wants to troubleshoot before making a change. Which sequence is MOST appropriate? Network changes from different technicians all appear under one shared local admin account, preventing accountability after an outage.
- First, Review chassis temperature, sensor thresholds, fan state and cabinet airflow trend. Then, Enable supported temperature, fan and PSU health monitoring with maintenance escalation thresholds.
- First, Compare live LLDP/VSF, circuit labels, asset registry and failover diagrams. Then, Update operational diagrams from verified device inventory and discovered physical/logical connectivity.
- First, Inspect AAA accounting, session logs, local roles and change records. Then, Use individual authorized identities and centralized or protected command/accounting logs.
- First, Inspect baseline history, current service listeners, change log and corrective action tickets. Then, Compare running configuration with approved baseline on a regular and event-triggered schedule.
Explanation
Correct Answer
C:Confirm: Each configuration change can be linked to the responsible operator and approved change request.
Incorrect Answers
A:This plan investigates a different issue (A rack switch operates near its maximum temperature each summer while operations monitors only Ethernet port utilization.). For the case described, inspect: Inspect AAA accounting, session logs, local roles and change records.
B:This plan investigates a different issue (The topology diagram shows one core switch while the actual building now uses a VSF pair with new distribution uplinks.). For the case described, inspect: Inspect AAA accounting, session logs, local roles and change records.
D:This plan investigates a different issue (A switch hardening audit passes at commissioning but subsequent emergency changes reenable an insecure management protocol.). For the case described, inspect: Inspect AAA accounting, session logs, local roles and change records.
Question 824
Following the planned correction, which outcome MOST strongly confirms success? A cloud-managed AOS-CX switch reverts a temporary local VLAN change because a centrally enforced template remains authoritative.
- The VLAN policy persists after management sync and intended site-specific exception is documented.
- All planned desks have dedicated policy-controlled switchports and powered handsets without oversubscription of the power budget.
- Initial device provisioning succeeds and deeper faults are diagnosed with supported detailed tools.
- The intended configuration applies only to compatible targets with no silent partial deployment.
Explanation
Correct Answer
A:The VLAN policy persists after management sync and intended site-specific exception is documented. Corresponding action: Identify the effective Central configuration ownership and apply approved changes through the authoritative workflow.
Incorrect Answers
B:That observation verifies a different fault (An office expansion needs 96 wired desks with PoE handsets, and purchasing selects one unmanaged eight-port switch based on low price.). For the question at hand, verify: The VLAN policy persists after management sync and intended site-specific exception is documented.
C:That observation verifies a different fault (An installer attempts to replace full core-switch troubleshooting with only a mobile onboarding app that lacks the needed detailed routing telemetry.). For the question at hand, verify: The VLAN policy persists after management sync and intended site-specific exception is documented.
D:That observation verifies a different fault (A deployment script configures a feature supported only on some AOS-CX releases, and half the switches reject the command.). For the question at hand, verify: The VLAN policy persists after management sync and intended site-specific exception is documented.
Question 825
What mistaken approach is MOST likely to worsen this networking fault? A campus closet's uplink documentation lists switch B on port 1/1/48 while cables were moved to port 1/1/47.
- Measure congestion and QoS drop counters under representative load.
- Use current platform release documentation for model-specific features.
- Trust an outdated asset spreadsheet over a consistently observed connected neighbor.
- Use SSH or secure management where supported and required.
Explanation
Correct Answer
C:Trust an outdated asset spreadsheet over a consistently observed connected neighbor. LLDP evidence helps identify the adjacent device but must be correlated with live forwarding state. Safer action: Use LLDP neighbor detail and interface counters to verify the active connected peer and port.
Incorrect Answers
A:Measure congestion and QoS drop counters under representative load. Prioritization does not create physical bandwidth. For the stated issue, the appropriate action is: Use LLDP neighbor detail and interface counters to verify the active connected peer and port.
B:Use current platform release documentation for model-specific features. Hardware and AOS-CX capabilities vary across series and versions. For the stated issue, the appropriate action is: Use LLDP neighbor detail and interface counters to verify the active connected peer and port.
D:Use SSH or secure management where supported and required. Encrypted authenticated management improves control-plane safety. For the stated issue, the appropriate action is: Use LLDP neighbor detail and interface counters to verify the active connected peer and port.
Question 826
Which TWO claims link a supported response and validation for this wired switching scenario? Two ports intended for a LAG operate at different negotiated speeds after an optic replacement and aggregation health degrades.
- Unsafe shortcut: Disable speed negotiation and force a fixed value without checking transceiver support.
- Verification: Cross-device logs align to a common event timeline and identify the initiating interface.
- Verification: Both LAG members negotiate compatible speeds and carry expected aggregate traffic.
- Action: Check supported optics, light levels, patch condition and cooling before altering routing policies.
- Action: Replace or reconfigure media to meet supported member compatibility before restoring redundancy.
Explanation
Correct Answers
C:Verification: Both LAG members negotiate compatible speeds and carry expected aggregate traffic. Aggregation may exclude members whose link capabilities are not compatible with the logical bundle.
E:Action: Replace or reconfigure media to meet supported member compatibility before restoring redundancy. Aggregation may exclude members whose link capabilities are not compatible with the logical bundle.
Incorrect Answers
A:Aggregation may exclude members whose link capabilities are not compatible with the logical bundle.
B:Verification: Cross-device logs align to a common event timeline and identify the initiating interface. This is validation for another condition (Two switches report intermittent spanning-tree changes but their logs use unsynchronized local clocks, obscuring the cause.). Here verify: Both LAG members negotiate compatible speeds and carry expected aggregate traffic.
D:This remedy fits a different fault (A fiber uplink shows intermittent packet loss and increasing CRC errors whenever temperatures rise in a poorly ventilated cabinet.).
Question 827
Following the planned correction, which outcome MOST strongly confirms success? The aggregation switch has connected routes but no path to 172.18.50.0/24 behind a remote router.
- The switch resolves management names through approved servers and connects using valid hostnames.
- VLAN99 appears on the intended interface and its MAC forwarding matches the approved topology.
- The observed neighbor and port map matches the corrected topology record.
- Traffic reaches the intended remote subnet through the planned peer with no routing loops.
Explanation
Correct Answer
D:Traffic reaches the intended remote subnet through the planned peer with no routing loops. Corresponding action: Add a reviewed specific static route with reachable next hop and confirm a suitable return route.
Incorrect Answers
A:That observation verifies a different fault (A switch can ping Central's management endpoint by IP but cannot resolve its hostname, blocking enrollment.). For the question at hand, verify: Traffic reaches the intended remote subnet through the planned peer with no routing loops.
B:That observation verifies a different fault (After migrating an access port, an operator relies solely on a change-ticket checkbox to claim VLAN99 is active on the port.). For the question at hand, verify: Traffic reaches the intended remote subnet through the planned peer with no routing loops.
C:That observation verifies a different fault (A campus closet's uplink documentation lists switch B on port 1/1/48 while cables were moved to port 1/1/47.). For the question at hand, verify: Traffic reaches the intended remote subnet through the planned peer with no routing loops.
Question 828
Which proposed action would be LEAST defensible for this AOS-CX or network problem? An inter-switch trunk receives untagged management traffic into different native VLANs at opposite ends.
- Measure congestion and QoS drop counters under representative load.
- Use SSH or secure management where supported and required.
- Verify port VLAN membership with operational state rather than ticket labels.
- Change IP addressing alone and leave the two native VLAN definitions inconsistent.
Explanation
Correct Answer
D:Change IP addressing alone and leave the two native VLAN definitions inconsistent. An 802.1Q native VLAN determines how untagged frames are classified on the trunk. Safer action: Align or explicitly tag the approved native VLAN settings and prevent unintended untagged cross-domain mapping.
Incorrect Answers
A:Measure congestion and QoS drop counters under representative load. Prioritization does not create physical bandwidth. For the stated issue, the appropriate action is: Align or explicitly tag the approved native VLAN settings and prevent unintended untagged cross-domain mapping.
B:Use SSH or secure management where supported and required. Encrypted authenticated management improves control-plane safety. For the stated issue, the appropriate action is: Align or explicitly tag the approved native VLAN settings and prevent unintended untagged cross-domain mapping.
C:Verify port VLAN membership with operational state rather than ticket labels. Actual forwarding can differ from intended configuration. For the stated issue, the appropriate action is: Align or explicitly tag the approved native VLAN settings and prevent unintended untagged cross-domain mapping.
Question 829
An AOS-CX learner investigates: A proposal assumes all advanced software features are present on every Aruba CX platform with no subscription or model restriction. What underlying concept should guide the response?
- Reliable switch automation converges on desired state rather than blindly replaying commands.
- Physical media and supported transceiver choices are constraints of the selected switch hardware.
- Power resilience depends on actual PSU and feed architecture rather than just multiple electrical outlets.
- Switching platform capabilities and cloud management entitlements can vary by model and product licensing.
Explanation
Correct Answer
D:Switching platform capabilities and cloud management entitlements can vary by model and product licensing. Appropriate intervention: Verify the feature and management-license requirements against the precise model, release and intended deployment.
Incorrect Answers
A:This concept applies to another switch problem (A script repeatedly creates the same VLAN and port description without checking existing state, generating failures on rerun.). Switching platform capabilities and cloud management entitlements can vary by model and product licensing.
B:This concept applies to another switch problem (A campus core requires a long fiber run but procurement supplies copper-only switch modules with no usable optical interface.).
C:This concept applies to another switch problem (A wiring closet must remain operational through one PSU failure but planners count two outlet sockets as redundant internal PSUs.). Switching platform capabilities and cloud management entitlements can vary by model and product licensing.
Question 830
What observed result BEST validates the change in this wired network case? A technician sees a large cumulative error counter and assumes a currently active fault despite no recent increment.
- Traffic consistently follows the NAS's actual port and the stale mapping no longer attracts frames.
- The intended neighbor forms and advertises routes with expected stability.
- Both LAG members negotiate compatible speeds and carry expected aggregate traffic.
- Error rates remain within tolerance during measured tests and no unnecessary hardware replacement occurs.
Explanation
Correct Answer
D:Error rates remain within tolerance during measured tests and no unnecessary hardware replacement occurs. Corresponding action: Compare time-normalized counter deltas under a known traffic interval before determining corrective work.
Incorrect Answers
A:That observation verifies a different fault (Several users see intermittent connection failures to a local NAS after it moved ports but an old static MAC mapping remains on the switch.). For the question at hand, verify: Error rates remain within tolerance during measured tests and no unnecessary hardware replacement occurs.
B:That observation verifies a different fault (OSPF neighbors between two core links never pass initialization although their areas and IPs match; their hello timers differ.). For the question at hand, verify: Error rates remain within tolerance during measured tests and no unnecessary hardware replacement occurs.
C:That observation verifies a different fault (Two ports intended for a LAG operate at different negotiated speeds after an optic replacement and aggregation health degrades.). For the question at hand, verify: Error rates remain within tolerance during measured tests and no unnecessary hardware replacement occurs.