HP HPE6-A86 Practice Test 78
Question 770
What fundamental switching or routing concept is MOST relevant here? A new server-facing switchport remains administratively disabled after an approved cable move even though the transceiver is detected.
- STP root election considers bridge identifiers; a low-priority unintended bridge can reshape paths.
- Factory/default and shared credentials undermine accountability and increase management compromise risk.
- An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
- Unique management identities reduce troubleshooting and change-control errors across similar devices.
Explanation
Correct Answer
C:An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence. Appropriate intervention: Enable only the intended interface and verify link and access policy before restoring server traffic.
Incorrect Answers
A:This concept applies to another switch problem (An access switch with default bridge priority becomes the RSTP root ahead of the designated distribution device.). An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
B:This concept applies to another switch problem (A new switch uses an administrative identity that all branch installers know, and the same password is reused on every device.). An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
D:This concept applies to another switch problem (Three new closet switches retain identical factory hostnames, causing logs and monitoring alerts to refer to an ambiguous node.). An administratively shut interface cannot forward user frames until explicitly enabled regardless of cable presence.
Question 771
Which proposed action would be LEAST defensible for this AOS-CX or network problem? A network manager orders a discontinued switch variant after seeing its family name on an old training slide without checking current support.
- Treat a decade-old catalog as proof every previous switch revision remains eligible for security updates.
- Correlate link fault counters with time and live traffic.
- Inspect the source management VRF when a switch-origin probe fails.
- Preserve separate management and guest network security boundaries.
Explanation
Correct Answer
A:Hardware family names are not sufficient evidence of current availability, software support or licensing entitlement.
Incorrect Answers
B:Correlate link fault counters with time and live traffic. Cumulative counters must be interpreted against a baseline. For the stated issue, the appropriate action is: Check current supported HPE Aruba Networking portfolio, software releases and lifecycle policy for the exact SKU.
C:Inspect the source management VRF when a switch-origin probe fails. Control-plane routes can differ from client forwarding paths. For the stated issue, the appropriate action is: Check current supported HPE Aruba Networking portfolio, software releases and lifecycle policy for the exact SKU.
D:Preserve separate management and guest network security boundaries. Least-privilege reachability limits management-plane exposure. For the stated issue, the appropriate action is: Check current supported HPE Aruba Networking portfolio, software releases and lifecycle policy for the exact SKU.
Question 772
Which measurable state would demonstrate the fault was resolved? An IPv6-enabled VLAN cannot communicate beyond its local prefix because the gateway lacks the intended IPv6 interface address or routing.
- A failed staging change can be reversed and all essential service VLANs return to baseline.
- Clients resolve the intended IPv6 gateway and reach approved remote IPv6 prefixes.
- Authorized administrators reach the correct device over TLS while guest attempts are refused.
- The approved filter is present and unauthorized traffic is denied in actual forwarding tests.
Explanation
Correct Answer
B:Clients resolve the intended IPv6 gateway and reach approved remote IPv6 prefixes. Corresponding action: Configure supported IPv6 addressing and routing for the correct SVI and verify neighbor discovery.
Incorrect Answers
A:That observation verifies a different fault (Before a campus commissioning change, staff overwrite many interface settings without capturing the previously working configuration.). For the question at hand, verify: Clients resolve the intended IPv6 gateway and reach approved remote IPv6 prefixes.
C:That observation verifies a different fault (The design requires browser-based operations but the tested AOS-CX model has an untrusted certificate and broad network exposure.). For the question at hand, verify: Clients resolve the intended IPv6 gateway and reach approved remote IPv6 prefixes.
D:That observation verifies a different fault (A remote change to an access switch unexpectedly removes a security filter and the team has no postchange verification checklist.). For the question at hand, verify: Clients resolve the intended IPv6 gateway and reach approved remote IPv6 prefixes.
Question 773
Following the planned correction, which outcome MOST strongly confirms success? A technician expects a four-link LAG to make one single TCP transfer four times faster than a member link.
- The destination MAC becomes learned and subsequent unicast traffic uses its proper outgoing interface.
- Broadcasts remain inside each intended VLAN and finance access is unaffected by guest chatter.
- Only designated administrators from the management subnet can connect while guest clients are refused.
- Aggregate bandwidth improves across diverse flows while a single flow follows its selected member link.
Explanation
Correct Answer
D:Aggregate bandwidth improves across diverse flows while a single flow follows its selected member link. This observed result validates the scoped repair. Corresponding action: Set realistic throughput expectations and validate hash distribution across multiple independent flows.
Incorrect Answers
A:That observation verifies a different fault (A campus access switch floods frames toward many ports after the destination MAC aged out during a quiet period.). For the question at hand, verify: Aggregate bandwidth improves across diverse flows while a single flow follows its selected member link.
B:That observation verifies a different fault (A guest VLAN broadcast storm spills onto a separate finance VLAN after staff accidentally bridged the two access segments.). For the question at hand, verify: Aggregate bandwidth improves across diverse flows while a single flow follows its selected member link.
C:That observation verifies a different fault (The out-of-band management interface of a new switch is reachable from the guest wireless subnet after installation.). For the question at hand, verify: Aggregate bandwidth improves across diverse flows while a single flow follows its selected member link.
Question 774
Select TWO statements: the correct intervention and its observed verification in this AOS-CX case. A new switch uses an administrative identity that all branch installers know, and the same password is reused on every device.
- Verification: Old shared credentials fail and approved site-specific administrators retain authorized access.
- Verification: The LAG forms with collecting/distributing members and correct partner system identifier.
- Unsafe shortcut: Keep a universal shared administrator password because the switch is inside a locked closet.
- Action: Replace generic credentials with unique managed administrative identities and supported AAA or role controls.
- Action: Use LLDP neighbor data and actual physical port tracing to identify the peer before changing trunk policy.
Explanation
Correct Answers
A:Verification: Old shared credentials fail and approved site-specific administrators retain authorized access. Factory/default and shared credentials undermine accountability and increase management compromise risk.
D:Action: Replace generic credentials with unique managed administrative identities and supported AAA or role controls. Factory/default and shared credentials undermine accountability and increase management compromise risk.
Incorrect Answers
B:Verification: The LAG forms with collecting/distributing members and correct partner system identifier. This is validation for another condition (Both endpoints of a new LAG are set to passive LACP operation and no members negotiate.). Here verify: Old shared credentials fail and approved site-specific administrators retain authorized access.
C:This is not a supported or safe intervention in this scenario. Factory/default and shared credentials undermine accountability and increase management compromise risk.
E:This remedy fits a different fault (After rewiring a campus distribution panel, staff see conflicting port-label records for one access uplink.).
Question 775
Which THREE conclusions correctly align remedy, principle and evidence for this situation? An installer attempts to replace full core-switch troubleshooting with only a mobile onboarding app that lacks the needed detailed routing telemetry.
- Action: Use vendor-supported copper/optical module combinations for the precise switch model and uplink type.
- Verification: The approved order matches required software and maintenance eligibility over the planned service lifetime.
- Verification: Initial device provisioning succeeds and deeper faults are diagnosed with supported detailed tools.
- Unsafe shortcut: Assume a mobile device showing a green checkmark proves every OSPF neighbor is correct.
- Principle: Management toolsets have different scopes and a commissioning interface does not replace all operational diagnostics.
- Action: Use the mobile app for supported setup tasks while relying on appropriate CLI, Central or API diagnostics for advanced analysis.
Explanation
Correct Answers
C:Verification: Initial device provisioning succeeds and deeper faults are diagnosed with supported detailed tools. Management toolsets have different scopes and a commissioning interface does not replace all operational diagnostics.
E:Principle: Management toolsets have different scopes and a commissioning interface does not replace all operational diagnostics. This causal networking concept connects the intervention and outcome.
F:Action: Use the mobile app for supported setup tasks while relying on appropriate CLI, Central or API diagnostics for advanced analysis. Management toolsets have different scopes and a commissioning interface does not replace all operational diagnostics.
Incorrect Answers
A:This remedy fits a different fault (A branch uses an RJ-45 SFP that requires host support but procurement assumes every optical SFP slot accepts all copper modules.). For this case use: Use the mobile app for supported setup tasks while relying on appropriate CLI, Central or API diagnostics for advanced analysis.
B:This is validation for another condition (A network manager orders a discontinued switch variant after seeing its family name on an old training slide without checking current support.).
D:Management toolsets have different scopes and a commissioning interface does not replace all operational diagnostics.
Question 776
What mistaken approach is MOST likely to worsen this networking fault? A recurring branch outage has several different fixes in chat messages but no versioned diagnostic guide, causing inconsistent recovery.
- Document a tested service restoration result before closing an outage.
- Test both allowed and denied network paths after access-control changes.
- Delete incident notes after each fix so every new technician starts from scratch.
- Avoid assuming web UI and CLI features are identical across devices.
Explanation
Correct Answer
C:Delete incident notes after each fix so every new technician starts from scratch. Standardized runbooks preserve operational knowledge while allowing evidence-based fault isolation. Safer action: Publish a reviewed troubleshooting runbook with evidence collection, decision points and rollback safeguards.
Incorrect Answers
A:Document a tested service restoration result before closing an outage. A successful command alone does not prove business recovery. For the stated issue, the appropriate action is: Publish a reviewed troubleshooting runbook with evidence collection, decision points and rollback safeguards.
B:Test both allowed and denied network paths after access-control changes. Negative tests confirm unauthorized paths remain restricted. For the stated issue, the appropriate action is: Publish a reviewed troubleshooting runbook with evidence collection, decision points and rollback safeguards.
D:Avoid assuming web UI and CLI features are identical across devices. Different platforms expose different supported management methods. For the stated issue, the appropriate action is: Publish a reviewed troubleshooting runbook with evidence collection, decision points and rollback safeguards.
Question 777
What specific operational information BEST distinguishes the cause of this issue? An untagged access port receives 802.1Q-tagged frames from a misconfigured endpoint and staff inspect only IP source addresses.
- Inspect DSCP at ingress/egress, queue statistics, utilization and media quality under load.
- Capture Ethernet headers, verify port mode and VLAN counters, and compare tagged versus untagged tests.
- Inspect forwarding table before and after traffic, interface source learning and VLAN-specific flood counters.
- Inspect ARP captures, SVI hardware addresses, duplicate IP events and switch MAC-port mapping.
Explanation
Correct Answer
B:Capture Ethernet headers, verify port mode and VLAN counters, and compare tagged versus untagged tests. 802.1Q adds VLAN identification in Ethernet frames, distinct from network-layer IP addresses. Next step: Match endpoint tagging expectations to the switchport access or trunk mode and its intended VLAN.
Incorrect Answers
A:This diagnostic addresses another network condition (A voice handset marks RTP packets with an approved DSCP but a downstream switch rewrites all traffic to best effort.). Here inspect: Capture Ethernet headers, verify port mode and VLAN counters, and compare tagged versus untagged tests.
C:This diagnostic addresses another network condition (A campus access switch floods frames toward many ports after the destination MAC aged out during a quiet period.). Here inspect: Capture Ethernet headers, verify port mode and VLAN counters, and compare tagged versus untagged tests.
D:This diagnostic addresses another network condition (A server has correct IP and gateway addressing but its ARP cache repeatedly learns the wrong gateway MAC after a test device was connected.). Here inspect: Capture Ethernet headers, verify port mode and VLAN counters, and compare tagged versus untagged tests.
Question 778
What mistaken approach is MOST likely to worsen this networking fault? An operator adds a repeater-style hub behind a managed switch and expects independent full-duplex Ethernet per hub port.
- Disable all switch loop prevention because a hub collision counter appears to increase.
- Confirm the approved gateway for traffic leaving a subnet.
- Retain change approval and operator accountability.
- Check optic and fiber compatibility when physical errors appear.
Explanation
Correct Answer
A:A legacy hub repeats symbols within one collision domain, whereas a switch isolates per-port Ethernet collisions.
Incorrect Answers
B:Confirm the approved gateway for traffic leaving a subnet. Off-subnet forwarding depends on usable Layer 3 next hops. For the stated issue, the appropriate action is: Replace the shared-media hub with switched Ethernet access or isolate its half-duplex collision domain.
C:Retain change approval and operator accountability. Production changes require traceable ownership and risk controls. For the stated issue, the appropriate action is: Replace the shared-media hub with switched Ethernet access or isolate its half-duplex collision domain.
D:Check optic and fiber compatibility when physical errors appear. Optical power and media standards constrain link operation. For the stated issue, the appropriate action is: Replace the shared-media hub with switched Ethernet access or isolate its half-duplex collision domain.
Question 779
Select TWO statements: the correct intervention and its observed verification in this AOS-CX case. A switch operator expects a traditional one-shot text file to be the only source of structured switch state used by automation.
- Unsafe shortcut: Edit random internal system database files directly to bypass switch configuration commands.
- Verification: The selected platform meets slot, throughput and power resiliency requirements with a validated growth plan.
- Verification: API and CLI inspection report coherent effective configuration and changes are auditable after a controlled update.
- Action: Use supported AOS-CX model-driven operational and configuration interfaces with documented consistency and backup procedures.
- Action: Configure intended management VRF addressing, route and allowed source path without leaking user networks into that VRF.
Explanation
Correct Answers
C:Verification: API and CLI inspection report coherent effective configuration and changes are auditable after a controlled update. AOS-CX exposes structured management information that can support programmatic operation beyond raw CLI screen scraping.
D:Action: Use supported AOS-CX model-driven operational and configuration interfaces with documented consistency and backup procedures. AOS-CX exposes structured management information that can support programmatic operation beyond raw CLI screen scraping.
Incorrect Answers
A:AOS-CX exposes structured management information that can support programmatic operation beyond raw CLI screen scraping.
B:This is validation for another condition (A regional core requires numerous line cards and high-density redundant power, but a fixed 24-port access model is proposed.).
E:This remedy fits a different fault (A core AOS-CX switch cannot be reached from the management network because the management interface lives in a separate VRF.).
Question 780
Identify the unsafe shortcut to REJECT for the following campus switching situation: A branch VSF stack reports that one member no longer participates after a stacking cable was unplugged.
- Maintain complete asset records and switch software inventory.
- Move a VSF stacking cable into an ordinary user-facing access port and call the stack restored.
- Test selected firmware rollback on a supported lab device.
- Retain change approval and operator accountability.
Explanation
Correct Answer
B:VSF groups supported switches into a coordinated virtual switching system, not a normal Ethernet LACP bundle.
Incorrect Answers
A:Maintain complete asset records and switch software inventory. Accurate inventory underpins maintenance and vulnerability handling. For the stated issue, the appropriate action is: Restore the supported VSF stacking links and validate member state and control-plane redundancy.
C:Test selected firmware rollback on a supported lab device. Upgrade reversibility should be validated before wide rollout. For the stated issue, the appropriate action is: Restore the supported VSF stacking links and validate member state and control-plane redundancy.
D:Retain change approval and operator accountability. Production changes require traceable ownership and risk controls. For the stated issue, the appropriate action is: Restore the supported VSF stacking links and validate member state and control-plane redundancy.