cert
cert-1
cert-2

Pass HP HPE6-A86 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
HPE6-A86 Exam - Verified By Experts
HPE6-A86 Premium Bundle
$14.99

HPE6-A86 Premium Bundle

$74.99
$89.98
  • Premium File 108 Questions & Answers. Last update: Nov 17, 2026
  • Study Guide 427 Pages
 
$89.98
$74.99
accept 17 downloads in last 7 days
block-screenshots
Purchase HP HPE6-A86 Exam Training Products Individually
HP HPE6-A86 Premium File
Premium File 108 Q&A
$76.99$69.99
HP HPE6-A86 PDF Study Guide
Study Guide 427 Pages
$21.99 $19.99
HP HPE6-A86 Practice Test 48

Question 470

For the following AOS-CX switching task, which intervention should the engineer take FIRST? An aggregation link sporadically drops packets but staff check only the logical VLAN table.

  1. Use show interface extended counters and optical or copper diagnostics to localize the physical error cause.
  2. Confirm the actual booted software image and version before applying release-dependent configuration.
  3. Set the appropriate supported passive OSPF interface design while retaining desired network advertisement.
  4. Align supported OSPF interface area and relevant peer parameters after verifying routing intent.

Explanation

Correct Answer

A:

Use show interface extended counters and optical or copper diagnostics to localize the physical error cause. Interface physical statistics reveal link impairments that VLAN membership alone cannot explain. Verified result: CRC/error rates return to baseline after targeted media remediation under comparable traffic load.

Incorrect Answers

B:

This change serves a different network condition (After first boot, a switch unexpectedly starts an old image despite a staged upgrade and the engineer proceeds without checking active software.), not the issue described. Appropriate response here: Use show interface extended counters and optical or copper diagnostics to localize the physical error cause.

C:

This change serves a different network condition (A VLAN interface serving end-user PCs emits OSPF hellos unnecessarily although no router is expected on that network.), not the issue described. Appropriate response here: Use show interface extended counters and optical or copper diagnostics to localize the physical error cause.

D:

This change serves a different network condition (Two routed AOS-CX switch interfaces are in the same IPv4 subnet but OSPF neighbors remain down because areas differ.), not the issue described.

Question 471

Before applying a production change, what diagnostic should the technician prioritize? An IPv6 endpoint gets router advertisements but cannot reach a peer because Neighbor Solicitation does not receive an answer.

  1. Compare server vSwitch port groups, Ethernet tags and AOS-CX trunk allowed/native configuration.
  2. Inspect VLAN database, trunk native and allowed list, packet tags and remote port membership.
  3. Capture ICMPv6 NS/NA, inspect neighbor cache and review VLAN multicast and ACL handling.
  4. Inspect candidate route status, interface subnets, ARP/ND for next hop and trace result.

Explanation

Correct Answer

C:

Capture ICMPv6 NS/NA, inspect neighbor cache and review VLAN multicast and ACL handling. IPv6 Neighbor Discovery uses ICMPv6 messages rather than IPv4 ARP for address-to-link mapping. Next step: Check IPv6 link-local scope, neighbor discovery filtering and Layer 2 multicast delivery.

Incorrect Answers

A:

Compare server vSwitch port groups, Ethernet tags and AOS-CX trunk allowed/native configuration. This diagnostic addresses another network condition (A virtualization host tags its guest networks but the switchport is configured as a single untagged access port.). Here inspect: Capture ICMPv6 NS/NA, inspect neighbor cache and review VLAN multicast and ACL handling.

B:

This diagnostic addresses another network condition (An uplink passes VLAN 10 but not the newly created VLAN 35 because the trunk allowed list was never updated.). Here inspect: Capture ICMPv6 NS/NA, inspect neighbor cache and review VLAN multicast and ACL handling.

D:

This diagnostic addresses another network condition (An engineer adds a route for a remote monitoring network using a next hop that is not reachable on any connected interface.). Here inspect: Capture ICMPv6 NS/NA, inspect neighbor cache and review VLAN multicast and ACL handling.

Question 472

Identify the unsafe shortcut to REJECT for the following campus switching situation: A regional core requires numerous line cards and high-density redundant power, but a fixed 24-port access model is proposed.

  1. Check a known-good rollback before a disruptive upgrade.
  2. Assume unused USB ports on an access switch can be populated with modular switching line cards.
  3. Maintain complete asset records and switch software inventory.
  4. Test selected firmware rollback on a supported lab device.

Explanation

Correct Answer

B:

Safer action: Evaluate modular switching platforms with documented redundancy and line-card expansion as required by the core design.

Incorrect Answers

A:

Check a known-good rollback before a disruptive upgrade. Controlled restoration reduces failed-change impact. For the stated issue, the appropriate action is: Evaluate modular switching platforms with documented redundancy and line-card expansion as required by the core design.

C:

Maintain complete asset records and switch software inventory. Accurate inventory underpins maintenance and vulnerability handling. For the stated issue, the appropriate action is: Evaluate modular switching platforms with documented redundancy and line-card expansion as required by the core design.

D:

Test selected firmware rollback on a supported lab device. Upgrade reversibility should be validated before wide rollout. For the stated issue, the appropriate action is: Evaluate modular switching platforms with documented redundancy and line-card expansion as required by the core design.

Question 473

A wired network administrator encounters: Two workstations share a switch yet belong to distinct IP subnets; a technician expects the switch MAC table alone to route between them. Which configuration or response is MOST appropriate?

  1. Identify the routing boundary and configure a supported SVI or external Layer 3 gateway for the intended subnets.
  2. Limit trunk allowed VLANs to the actual service inventory and validate required tagged reachability.
  3. Restrict the management plane and where supported migrate to SNMPv3 authenticated and encrypted monitoring.
  4. Validate each application's transport and port policy separately for the intended management functions.

Explanation

Correct Answer

A:

Layer 2 forwarding uses MAC learning within a VLAN; IP forwarding requires Layer 3 routing decisions. Verified result: Inter-subnet packets traverse the selected gateway, while same-VLAN forwarding stays at Ethernet Layer 2.

Incorrect Answers

B:

This change serves a different network condition (A server rack trunk carries every lab VLAN although only two production VLANs are needed on its uplink.), not the issue described. Appropriate response here: Identify the routing boundary and configure a supported SVI or external Layer 3 gateway for the intended subnets.

C:

This change serves a different network condition (A monitoring station polls switch counters via SNMPv2c using a default community string discoverable by guest clients.), not the issue described. Appropriate response here: Identify the routing boundary and configure a supported SVI or external Layer 3 gateway for the intended subnets.

D:

This change serves a different network condition (A test host reaches TCP port 22 of a switch but not UDP port 161 and the operator assumes successful SSH proves SNMP availability.), not the issue described. Appropriate response here: Identify the routing boundary and configure a supported SVI or external Layer 3 gateway for the intended subnets.

Question 474

What fundamental switching or routing concept is MOST relevant here? Several users see intermittent connection failures to a local NAS after it moved ports but an old static MAC mapping remains on the switch.

  1. Storm localization benefits from per-port counters and topology data rather than random switch restarts.
  2. STP election uses active bridge identifiers, so unsaved configurations can alter forwarding topology.
  3. Static MAC forwarding entries override dynamic learning and can point traffic to an obsolete location.
  4. Switch-generated test traffic may use different source interfaces or VRFs than data-plane forwarded traffic.

Explanation

Correct Answer

C:

Static MAC forwarding entries override dynamic learning and can point traffic to an obsolete location. Appropriate intervention: Remove or update the obsolete static MAC entry and validate dynamic forwarding learning.

Incorrect Answers

A:

This concept applies to another switch problem (A large spike in broadcast traffic follows a new office wall jack installation and staff cannot locate the originating port.). Static MAC forwarding entries override dynamic learning and can point traffic to an obsolete location.

B:

This concept applies to another switch problem (A planned reboot changes the STP root unexpectedly because preferred bridge priority was applied only to the running configuration.). Static MAC forwarding entries override dynamic learning and can point traffic to an obsolete location.

D:

This concept applies to another switch problem (Operations can SSH to the core from the NOC but a switch-origin ping to an NTP server fails because the wrong source VRF is used.). Static MAC forwarding entries override dynamic learning and can point traffic to an obsolete location.

Question 475

Identify the unsafe shortcut to REJECT for the following campus switching situation: A wiring closet must remain operational through one PSU failure but planners count two outlet sockets as redundant internal PSUs.

  1. Use current platform release documentation for model-specific features.
  2. Plug a single-PSU switch into a two-socket power strip and label it dual-redundant.
  3. Confirm the approved gateway for traffic leaving a subnet.
  4. Keep recovery configuration files protected and versioned.

Explanation

Correct Answer

B:

Plug a single-PSU switch into a two-socket power strip and label it dual-redundant. Power resilience depends on actual PSU and feed architecture rather than just multiple electrical outlets. Safer action: Select a switch with supported redundant power capacity and independent suitable AC distribution.

Incorrect Answers

A:

Use current platform release documentation for model-specific features. Hardware and AOS-CX capabilities vary across series and versions. For the stated issue, the appropriate action is: Select a switch with supported redundant power capacity and independent suitable AC distribution.

C:

Confirm the approved gateway for traffic leaving a subnet. Off-subnet forwarding depends on usable Layer 3 next hops. For the stated issue, the appropriate action is: Select a switch with supported redundant power capacity and independent suitable AC distribution.

D:

Keep recovery configuration files protected and versioned. Backup confidentiality and integrity support safe restoration. For the stated issue, the appropriate action is: Select a switch with supported redundant power capacity and independent suitable AC distribution.

Question 476

Following the planned correction, which outcome MOST strongly confirms success? A purchasing team wants to combine mixed switch series into one VSF stack even though supported member compatibility is not established.

  1. Congestion decreases after the uplink design is validated with representative multiple-user load.
  2. The stack boots predictably with valid members and planned master/standby roles.
  3. Read-only status inspection works, unauthorized writes fail and approved change records identify the operator.
  4. The serial/model is associated with the intended tenant and reports healthy managed status.

Explanation

Correct Answer

B:

The stack boots predictably with valid members and planned master/standby roles. Corresponding action: Choose a supported compatible VSF member set and documented stacking interconnect and software alignment.

Incorrect Answers

A:

That observation verifies a different fault (A remote closet has forty gigabit users and a 1-Gb/s uplink saturated by backups, yet planners buy more client ports without changing aggregation.). Congestion decreases after the uplink design is validated with representative multiple-user load.

C:

That observation verifies a different fault (A support contractor can view port status through a CLI role but is denied configuration writes, and an administrator assumes the switch is faulty.). For the question at hand, verify: The stack boots predictably with valid members and planned master/standby roles.

D:

That observation verifies a different fault (A new AOS-CX switch has Layer 2 connectivity but never becomes visible in HPE Aruba Networking Central inventory.). The serial/model is associated with the intended tenant and reports healthy managed status.

Question 477

Which proposed action would be LEAST defensible for this AOS-CX or network problem? A new uplink is physically patched into port 1/1/48 but the running configuration still describes it as a decommissioned printer.

  1. Assume renaming an interface description changes what physical device is attached.
  2. Separate an Ethernet tagging fault from an IP route fault.
  3. Inspect the source management VRF when a switch-origin probe fails.
  4. Choose switch hardware against traffic, PoE, and resiliency requirements.

Explanation

Correct Answer

A:

Assume renaming an interface description changes what physical device is attached. Documented interface descriptions aid operations but do not replace actual port discovery and verification. Safer action: Update the interface description and asset/cable record while validating actual operational connection.

Incorrect Answers

B:

Separate an Ethernet tagging fault from an IP route fault. Correct problem-layer isolation avoids ineffective reconfiguration. For the stated issue, the appropriate action is: Update the interface description and asset/cable record while validating actual operational connection.

C:

Inspect the source management VRF when a switch-origin probe fails. Control-plane routes can differ from client forwarding paths. For the stated issue, the appropriate action is: Update the interface description and asset/cable record while validating actual operational connection.

D:

Choose switch hardware against traffic, PoE, and resiliency requirements. Product capabilities vary independently of procurement price. For the stated issue, the appropriate action is: Update the interface description and asset/cable record while validating actual operational connection.

Question 478

Which TWO claims link a supported response and validation for this wired switching scenario? A VLAN interface serving end-user PCs emits OSPF hellos unnecessarily although no router is expected on that network.

  1. Verification: Logs, CLI prompts and monitoring inventory uniquely identify each physical device and site.
  2. Verification: Hosts stop receiving routing hellos and the required subnet remains advertised to intended routing peers.
  3. Action: Set the appropriate supported passive OSPF interface design while retaining desired network advertisement.
  4. Unsafe shortcut: Remove all routing protocol configuration from the core because one user VLAN should be passive.
  5. Action: Use show spanning-tree instance and bridge information to identify the elected root and port states.

Explanation

Correct Answers

B:

Verification: Hosts stop receiving routing hellos and the required subnet remains advertised to intended routing peers. Passive interfaces suppress OSPF neighbor formation on selected networks while route advertisement can remain configured.

C:

Action: Set the appropriate supported passive OSPF interface design while retaining desired network advertisement. Passive interfaces suppress OSPF neighbor formation on selected networks while route advertisement can remain configured.

Incorrect Answers

A:

This is validation for another condition (Three new closet switches retain identical factory hostnames, causing logs and monitoring alerts to refer to an ambiguous node.).

D:

Passive interfaces suppress OSPF neighbor formation on selected networks while route advertisement can remain configured.

E:

This remedy fits a different fault (A distribution design expects switch A to be root but a technician reads only port LEDs and cannot explain the blocked uplink.). For this case use: Set the appropriate supported passive OSPF interface design while retaining desired network advertisement.

Question 479

For the following AOS-CX switching task, which intervention should the engineer take FIRST? A core AOS-CX switch cannot be reached from the management network because the management interface lives in a separate VRF.

  1. Choose approved multi-gig capable access ports and adequate uplink speed for required devices.
  2. Validate supported web or CLI management services for the exact AOS-CX model and provision approved addresses and access.
  3. Configure intended management VRF addressing, route and allowed source path without leaking user networks into that VRF.
  4. Use the mobile app for supported setup tasks while relying on appropriate CLI, Central or API diagnostics for advanced analysis.

Explanation

Correct Answer

C:

Configure intended management VRF addressing, route and allowed source path without leaking user networks into that VRF. AOS-CX can separate management and data-plane routing contexts using supported VRFs. Verified result: Authorized out-of-band administration works and production forwarding remains separately routed.

Incorrect Answers

A:

This change serves a different network condition (A high-density access site requires 2.5-Gb/s access for Wi-Fi uplinks but selects a platform whose edge ports are gigabit-only.), not the issue described. Appropriate response here: Configure intended management VRF addressing, route and allowed source path without leaking user networks into that VRF.

B:

This change serves a different network condition (A field operator assumes every Aruba switch ships with the same always-enabled in-band web GUI and no setup is needed.), not the issue described. Appropriate response here: Configure intended management VRF addressing, route and allowed source path without leaking user networks into that VRF.

D:

This change serves a different network condition (An installer attempts to replace full core-switch troubleshooting with only a mobile onboarding app that lacks the needed detailed routing telemetry.), not the issue described. Appropriate response here: Configure intended management VRF addressing, route and allowed source path without leaking user networks into that VRF.

Question 480

Following the planned correction, which outcome MOST strongly confirms success? Two server NICs are supposed to use a dynamic LAG but the switch has interfaces configured separately with different VLAN modes.

  1. The observed neighbor and port map matches the corrected topology record.
  2. LACP reports both members synchronized and server traffic stays on intended VLANs.
  3. Traffic reaches the intended remote subnet through the planned peer with no routing loops.
  4. The preferred path appears in routing and traffic moves to backup on a controlled primary failure.

Explanation

Correct Answer

B:

LACP reports both members synchronized and server traffic stays on intended VLANs. Corresponding action: Build the supported LAG, set compatible member settings and apply the approved VLAN configuration to the aggregate.

Incorrect Answers

A:

That observation verifies a different fault (A campus closet's uplink documentation lists switch B on port 1/1/48 while cables were moved to port 1/1/47.). For the question at hand, verify: LACP reports both members synchronized and server traffic stays on intended VLANs.

C:

That observation verifies a different fault (The aggregation switch has connected routes but no path to 172.18.50.0/24 behind a remote router.). For the question at hand, verify: LACP reports both members synchronized and server traffic stays on intended VLANs.

D:

That observation verifies a different fault (Two redundant OSPF paths exist but traffic selects the slower backup because link costs were never reviewed.). For the question at hand, verify: LACP reports both members synchronized and server traffic stays on intended VLANs.

HPE Network Switching Associate (HPE6-A86) Practice Tests