HP HPE6-A86 Practice Test 45

Question 440

Which measurable state would demonstrate the fault was resolved? An operator adds a repeater-style hub behind a managed switch and expects independent full-duplex Ethernet per hub port.

  1. Host links attached to distinct switchports negotiate full duplex without hub-shared collisions.
  2. Link restoration makes the Ethernet interface operational and the application succeeds without changing HTTP content.
  3. Off-subnet destinations follow the expected route while direct connected networks stay reachable.
  4. The optical receiver sees valid light and the fiber interface reaches the expected operational speed.

Explanation

Correct Answer

A:

Host links attached to distinct switchports negotiate full duplex without hub-shared collisions. Corresponding action: Replace the shared-media hub with switched Ethernet access or isolate its half-duplex collision domain.

Incorrect Answers

B:

That observation verifies a different fault (An inventory application sends correct HTTP requests, but an operator blames its Layer 7 data when the distribution uplink has no physical signal.). For the question at hand, verify: Host links attached to distinct switchports negotiate full duplex without hub-shared collisions.

C:

That observation verifies a different fault (A local VLAN can reach its own gateway but cannot reach outside prefixes because the core routing table lacks a default path.).

D:

That observation verifies a different fault (A short-reach duplex fiber optic uplink has correct optic types but no signal after installers swapped patch cords.). For the question at hand, verify: Host links attached to distinct switchports negotiate full duplex without hub-shared collisions.

Question 441

Which evidence should be examined FIRST to localize this switch-related fault? Users report that a VoIP phone carries voice but its attached PC cannot join the data VLAN after a trunk policy update.

  1. Capture VLAN tags at both ends, inspect allowed/native lists and MAC learning for the two directions.
  2. Review Ethernet 802.1Q headers, LLDP-MED policy, access/trunk mode and DHCP offer VLAN.
  3. Record baseline and follow-up counters, interface uptime and current traffic volume.
  4. Capture DHCP Discover/Offer and relay giaddr, inspect helper settings and server scope.

Explanation

Correct Answer

B:

Review Ethernet 802.1Q headers, LLDP-MED policy, access/trunk mode and DHCP offer VLAN. Packet traces show what was transmitted and help distinguish VLAN tagging from IP configuration faults. Next step: Capture traffic at the port/uplink and identify actual untagged and tagged VLAN IDs against policy.

Incorrect Answers

A:

This diagnostic addresses another network condition (One office can reach the local file server but replies disappear over an uplink because VLAN60 is tagged on one side and treated as untagged on the other.). Here inspect: Review Ethernet 802.1Q headers, LLDP-MED policy, access/trunk mode and DHCP offer VLAN.

C:

Record baseline and follow-up counters, interface uptime and current traffic volume. This diagnostic addresses another network condition (A technician sees a large cumulative error counter and assumes a currently active fault despite no recent increment.). Here inspect: Review Ethernet 802.1Q headers, LLDP-MED policy, access/trunk mode and DHCP offer VLAN.

D:

Capture DHCP Discover/Offer and relay giaddr, inspect helper settings and server scope. This diagnostic addresses another network condition (Clients on a newly commissioned routed VLAN receive no DHCP offers while same-VLAN static clients reach the gateway.). Here inspect: Review Ethernet 802.1Q headers, LLDP-MED policy, access/trunk mode and DHCP offer VLAN.

Question 442

What fundamental switching or routing concept is MOST relevant here? A lab switch allows Telnet logins across an untrusted contractor VLAN despite password authentication being enabled.

  1. LAG member admission depends on compatible physical and logical properties rather than just a shared label.
  2. An access VLAN classifies untagged traffic into one configured Ethernet broadcast domain.
  3. A hypervisor trunk requires consistent VLAN tagging expectations on the virtual and physical switch boundaries.
  4. Telnet transmits session content without SSH transport encryption and is unsuitable for untrusted administration.

Explanation

Correct Answer

D:

Telnet transmits session content without SSH transport encryption and is unsuitable for untrusted administration. Appropriate intervention: Disable insecure remote terminal access and permit supported SSH administration from a restricted management network.

Incorrect Answers

A:

This concept applies to another switch problem (One member of a two-port LAG has an incompatible speed or VLAN configuration and never enters the operational bundle.). Telnet transmits session content without SSH transport encryption and is unsuitable for untrusted administration.

B:

This concept applies to another switch problem (A network printer has a DHCP lease from the visitor subnet because its switchport retains the visitor access VLAN.). Telnet transmits session content without SSH transport encryption and is unsuitable for untrusted administration.

C:

This concept applies to another switch problem (A virtualization host tags its guest networks but the switchport is configured as a single untagged access port.). Telnet transmits session content without SSH transport encryption and is unsuitable for untrusted administration.

Question 443

Identify the unsafe shortcut to REJECT for the following campus switching situation: A field team inserts a long-reach optic into a short multimode path and observes intermittent receive-power alarms.

  1. Disable optical alarms indefinitely rather than investigate a mismatched transceiver or attenuator requirement.
  2. Keep authenticated management credentials out of unprotected logs.
  3. Validate switch software image compatibility before deployment.
  4. Check optic and fiber compatibility when physical errors appear.

Explanation

Correct Answer

A:

Disable optical alarms indefinitely rather than investigate a mismatched transceiver or attenuator requirement. Optical interface reliability depends on matching module specification, fiber type and link budget. Safer action: Select a supported optic and fiber type with an appropriate wavelength, distance and optical budget.

Incorrect Answers

B:

Keep authenticated management credentials out of unprotected logs. Administrative secrets need confidentiality and access controls. For the stated issue, the appropriate action is: Select a supported optic and fiber type with an appropriate wavelength, distance and optical budget.

C:

Validate switch software image compatibility before deployment. Unsupported images can prevent reliable device startup. For the stated issue, the appropriate action is: Select a supported optic and fiber type with an appropriate wavelength, distance and optical budget.

D:

Check optic and fiber compatibility when physical errors appear. Optical power and media standards constrain link operation. For the stated issue, the appropriate action is: Select a supported optic and fiber type with an appropriate wavelength, distance and optical budget.

Question 444

What fundamental switching or routing concept is MOST relevant here? A monitoring station polls switch counters via SNMPv2c using a default community string discoverable by guest clients.

  1. 1000BASE-T depends on suitable twisted-pair wiring and pair integrity, not merely IP address correctness.
  2. SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.
  3. VLAN identifiers have significance across the connected Layer 2 domain and require coherent service mapping.
  4. A /26 mask divides a /24 into blocks of 64 addresses and ARP is used for local on-link destinations.

Explanation

Correct Answer

B:

SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections. Appropriate intervention: Restrict the management plane and where supported migrate to SNMPv3 authenticated and encrypted monitoring.

Incorrect Answers

A:

This concept applies to another switch problem (An office switch negotiates 100 Mb/s unexpectedly after a patch-panel repair although both endpoints support gigabit copper.). SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.

C:

This concept applies to another switch problem (A campus migration uses VLAN 200 for finance in one wiring closet and VLAN 200 for lab traffic on a connected trunk.). SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.

D:

This concept applies to another switch problem (A switch SVI is configured as 192.0.2.126/26 while a new host uses 192.0.2.130/26 and expects same-subnet ARP.). SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.

Question 445

A wired network administrator encounters: A set of branch switches joins cloud management but receives an inappropriate template due to assignment to the wrong device group. Which configuration or response is MOST appropriate?

  1. Evaluate supported event-driven telemetry or analytics capabilities and integrate alerts with bounded collection policies.
  2. Keep the least-privilege operator role and schedule authorized configuration changes under separate administrative identity.
  3. Plan a managed access switching design with sufficient ports, PoE budget and uplink capacity for the complete endpoint count.
  4. Correct group/template assignment using approved model-specific configuration and stage the change.

Explanation

Correct Answer

D:

Correct group/template assignment using approved model-specific configuration and stage the change. Central groups and templates determine which managed configuration policies apply to enrolled equipment. Verified result: Branches receive the intended standard and special sites preserve documented exceptions.

Incorrect Answers

A:

This change serves a different network condition (Operations wants automated alerts on abnormal link flap patterns but plans to poll all interface counters at one-second intervals from a fragile script.), not the issue described. Appropriate response here: Correct group/template assignment using approved model-specific configuration and stage the change.

B:

This change serves a different network condition (A support contractor can view port status through a CLI role but is denied configuration writes, and an administrator assumes the switch is faulty.), not the issue described. Appropriate response here: Correct group/template assignment using approved model-specific configuration and stage the change.

C:

This change serves a different network condition (An office expansion needs 96 wired desks with PoE handsets, and purchasing selects one unmanaged eight-port switch based on low price.), not the issue described. Appropriate response here: Correct group/template assignment using approved model-specific configuration and stage the change.

Question 446

Following the planned correction, which outcome MOST strongly confirms success? A switch web-management hostname fails but HTTPS works by its IP address from the same workstation.

  1. Both links report matching partner and aggregator state with expected multiflow forwarding capacity.
  2. Clients reach remote VLAN destinations through the intended gateway while same-subnet service remains unchanged.
  3. The intended neighbor forms and advertises routes with expected stability.
  4. The approved FQDN resolves to the intended management address and trusted HTTPS loads.

Explanation

Correct Answer

D:

The approved FQDN resolves to the intended management address and trusted HTTPS loads. Corresponding action: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

Incorrect Answers

A:

That observation verifies a different fault (A campus uplink LAG stays up but only one of two links forwards, and the nonforwarding member shows a different partner system ID.). For the question at hand, verify: The approved FQDN resolves to the intended management address and trusted HTTPS loads.

B:

That observation verifies a different fault (A subnet's PCs can ping each other but never reach the building printer subnet after a DHCP option points them at an old gateway.). Clients reach remote VLAN destinations through the intended gateway while same-subnet service remains unchanged.

C:

That observation verifies a different fault (OSPF neighbors between two core links never pass initialization although their areas and IPs match; their hello timers differ.). For the question at hand, verify: The approved FQDN resolves to the intended management address and trusted HTTPS loads.

Question 447

For this wired switching issue, which investigation and response plan is MOST defensible? An access-uplink trunk unexpectedly accepts untagged traffic into VLAN 1 when policy requires management VLAN 30 to be explicitly tagged.

  1. First, Inspect routing table, selected gateway, ACL and upstream firewall return path. Then, Configure a controlled 0.0.0.0/0 route toward the intended upstream firewall for unmatched destinations.
  2. First, Check show lldp neighbor-info detail, interface descriptions and cable inventory. Then, Use LLDP neighbor data and actual physical port tracing to identify the peer before changing trunk policy.
  3. First, Test revoked login, privilege map, credential storage and authentication audit. Then, Replace generic credentials with unique managed administrative identities and supported AAA or role controls.
  4. First, Inspect trunk native tag mode, allowed list and captures of tagged and untagged tests. Then, Configure supported native VLAN and tagging behavior and restrict allowed VLANs according to the approved trunk design.

Explanation

Correct Answer

D:

Native VLAN and explicit tagging determine how untagged Ethernet frames are handled on trunks.

Incorrect Answers

A:

This plan investigates a different issue (A branch AOS-CX L3 switch supports internal VLAN routing but cannot reach external destinations because no default route exists.). For the case described, inspect: Inspect trunk native tag mode, allowed list and captures of tagged and untagged tests.

B:

This plan investigates a different issue (After rewiring a campus distribution panel, staff see conflicting port-label records for one access uplink.).

C:

This plan investigates a different issue (A new switch uses an administrative identity that all branch installers know, and the same password is reused on every device.).

Question 448

Following the planned correction, which outcome MOST strongly confirms success? After several virtual machines move hosts, traffic briefly floods an access VLAN while dynamic MAC entries are relearned.

  1. Both eligible members join the intended LAG with consistent VLAN carriage and no loops.
  2. Link restoration makes the Ethernet interface operational and the application succeeds without changing HTTP content.
  3. The optical receiver sees valid light and the fiber interface reaches the expected operational speed.
  4. After convergence, frames are forwarded on learned ports and unexpected flooding subsides.

Explanation

Correct Answer

D:

After convergence, frames are forwarded on learned ports and unexpected flooding subsides. Corresponding action: Validate source-MAC learning and transient unknown-unicast behavior rather than hardcode every destination MAC.

Incorrect Answers

A:

That observation verifies a different fault (One member of a two-port LAG has an incompatible speed or VLAN configuration and never enters the operational bundle.). Both eligible members join the intended LAG with consistent VLAN carriage and no loops.

B:

That observation verifies a different fault (An inventory application sends correct HTTP requests, but an operator blames its Layer 7 data when the distribution uplink has no physical signal.). For the question at hand, verify: After convergence, frames are forwarded on learned ports and unexpected flooding subsides.

C:

That observation verifies a different fault (A short-reach duplex fiber optic uplink has correct optic types but no signal after installers swapped patch cords.). For the question at hand, verify: After convergence, frames are forwarded on learned ports and unexpected flooding subsides.

Question 449

A wired network administrator encounters: A switch web-management hostname fails but HTTPS works by its IP address from the same workstation. Which configuration or response is MOST appropriate?

  1. Inspect effective routed ACL direction and adjust the approved policy to permit required bidirectional flows.
  2. Correlate STP topology-change events with affected edge ports and apply appropriate edge protection policies.
  3. Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.
  4. Verify the switch's DHCP relay target and forwarding ACLs toward the remote server.

Explanation

Correct Answer

C:

Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed. Name resolution failures are distinct from transport/application reachability to a known IP. Verified result: The approved FQDN resolves to the intended management address and trusted HTTPS loads.

Incorrect Answers

A:

This change serves a different network condition (A switch can ping a host in VLAN25 but a remote host cannot return traffic after an ACL change on the SVI.), not the issue described. Appropriate response here: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

B:

This change serves a different network condition (During afternoon use, a small office suffers bursts of MAC-table instability every time a contractor unplugs a mini-switch in a meeting room.), not the issue described. Appropriate response here: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

D:

This change serves a different network condition (Clients on a newly commissioned routed VLAN receive no DHCP offers while same-VLAN static clients reach the gateway.), not the issue described. Appropriate response here: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.

Question 450

Identify the unsafe shortcut to REJECT for the following campus switching situation: A newly deployed access point cannot connect after switch security protection placed its port into a disabled state on detecting a BPDU.

  1. Avoid assuming web UI and CLI features are identical across devices.
  2. Choose switch hardware against traffic, PoE, and resiliency requirements.
  3. Check optic and fiber compatibility when physical errors appear.
  4. Repeatedly enable the port while ignoring the unexpected bridging protocol source.

Explanation

Correct Answer

D:

Repeatedly enable the port while ignoring the unexpected bridging protocol source. Port protection events should be diagnosed before administrative recovery to prevent repeated loops. Safer action: Determine whether the attached device is appropriate and correct its cabling or edge-policy treatment before recovery.

Incorrect Answers

A:

Avoid assuming web UI and CLI features are identical across devices. Different platforms expose different supported management methods. For the stated issue, the appropriate action is: Determine whether the attached device is appropriate and correct its cabling or edge-policy treatment before recovery.

B:

Choose switch hardware against traffic, PoE, and resiliency requirements. Product capabilities vary independently of procurement price. For the stated issue, the appropriate action is: Determine whether the attached device is appropriate and correct its cabling or edge-policy treatment before recovery.

C:

Check optic and fiber compatibility when physical errors appear. Optical power and media standards constrain link operation. For the stated issue, the appropriate action is: Determine whether the attached device is appropriate and correct its cabling or edge-policy treatment before recovery.