HP HPE6-A86 Practice Test 113
Question 1120
What observed result BEST validates the change in this wired network case? A campus engineer attempts to apply an AOS-Switch-specific CLI command sequence unchanged on a device running AOS-CX.
- Only the chosen supported interface responds from approved management hosts, with credentials and TLS policy enforced.
- Measured uplink utilization stays within design targets and routed service traffic follows clear aggregation boundaries.
- Operations can access core management during an isolated user-plane trunk failure.
- The intended settings appear correctly in running configuration and surviving links remain healthy.
Explanation
Correct Answer
D:The intended settings appear correctly in running configuration and surviving links remain healthy. Corresponding action: Identify actual OS family and switch model and use its documented AOS-CX configuration and show-command syntax.
Incorrect Answers
A:That observation verifies a different fault (A field operator assumes every Aruba switch ships with the same always-enabled in-band web GUI and no setup is needed.). For the question at hand, verify: The intended settings appear correctly in running configuration and surviving links remain healthy.
B:That observation verifies a different fault (A branch places forty access switches directly on a perimeter firewall with no suitable uplink distribution and experiences oversubscribed forwarding.). For the question at hand, verify: The intended settings appear correctly in running configuration and surviving links remain healthy.
C:That observation verifies a different fault (A network architect wants troubleshooting access during a data-VLAN outage but locates all switch management behind the same failed user trunk.). For the question at hand, verify: The intended settings appear correctly in running configuration and surviving links remain healthy.
Question 1121
An AOS-CX learner investigates: A switch web-management hostname fails but HTTPS works by its IP address from the same workstation. What underlying concept should guide the response?
- Local self-ping validates an address stack, not any external cable, VLAN or neighbor state.
- LACP membership requires compatible actor/partner information; a mismatched peer cannot safely join.
- Name resolution failures are distinct from transport/application reachability to a known IP.
- Routed connectivity needs usable paths in both directions, not merely successful outbound packet forwarding.
Explanation
Correct Answer
C:Name resolution failures are distinct from transport/application reachability to a known IP. Appropriate intervention: Test DNS resolution separately from the HTTPS listener and correct name/service mappings as needed.
Incorrect Answers
A:This concept applies to another switch problem (A newly provisioned switch can ping its own loopback IP but not the default gateway, yet an operator calls the uplink healthy.). Name resolution failures are distinct from transport/application reachability to a known IP.
B:This concept applies to another switch problem (A campus uplink LAG stays up but only one of two links forwards, and the nonforwarding member shows a different partner system ID.). Name resolution failures are distinct from transport/application reachability to a known IP.
D:This concept applies to another switch problem (Traffic reaches a remote printer server from a new department VLAN, but the printer server's reply follows a firewall with no path back.). Name resolution failures are distinct from transport/application reachability to a known IP.
Question 1122
Which technical networking principle BEST explains this condition? A network manager orders a discontinued switch variant after seeing its family name on an old training slide without checking current support.
- Central groups and templates determine which managed configuration policies apply to enrolled equipment.
- Fixed access and modular chassis designs address different expansion, performance and operational requirements.
- Hardware family names are not sufficient evidence of current availability, software support or licensing entitlement.
- Cloud management registration depends on device identity, network reachability and licensing or subscription workflow.
Explanation
Correct Answer
C:Hardware family names are not sufficient evidence of current availability, software support or licensing entitlement. Appropriate intervention: Check current supported HPE Aruba Networking portfolio, software releases and lifecycle policy for the exact SKU.
Incorrect Answers
A:This concept applies to another switch problem (A set of branch switches joins cloud management but receives an inappropriate template due to assignment to the wrong device group.). Hardware family names are not sufficient evidence of current availability, software support or licensing entitlement.
B:This concept applies to another switch problem (A regional core requires numerous line cards and high-density redundant power, but a fixed 24-port access model is proposed.). Hardware family names are not sufficient evidence of current availability, software support or licensing entitlement.
D:This concept applies to another switch problem (A new AOS-CX switch has Layer 2 connectivity but never becomes visible in HPE Aruba Networking Central inventory.). Hardware family names are not sufficient evidence of current availability, software support or licensing entitlement.
Question 1123
An AOS-CX learner investigates: A support VLAN can reach same-VLAN hosts but not a management VLAN even though both VLANs are allowed on the uplink. What underlying concept should guide the response?
- VLAN identifiers have significance across the connected Layer 2 domain and require coherent service mapping.
- VLAN trunk allowance permits Layer 2 carriage but does not itself create a Layer 3 path between subnets.
- PoE power delivered by ports is constrained by device requirements and the switch power budget.
- Policing drops traffic exceeding a limit, while shaping buffers and paces traffic under supported implementations.
Explanation
Correct Answer
B:VLAN trunk allowance permits Layer 2 carriage but does not itself create a Layer 3 path between subnets. Appropriate intervention: Provide appropriately scoped Layer 3 gateways, routing and security policy between the two VLANs.
Incorrect Answers
A:This concept applies to another switch problem (A campus migration uses VLAN 200 for finance in one wiring closet and VLAN 200 for lab traffic on a connected trunk.). VLAN trunk allowance permits Layer 2 carriage but does not itself create a Layer 3 path between subnets.
C:This concept applies to another switch problem (A stack of badge readers reboots during shift change after the access switch exhausts its available PoE budget.). VLAN trunk allowance permits Layer 2 carriage but does not itself create a Layer 3 path between subnets.
D:This concept applies to another switch problem (A backup job saturates a campus uplink and a technician proposes policing voice media to solve file-transfer congestion.). VLAN trunk allowance permits Layer 2 carriage but does not itself create a Layer 3 path between subnets.
Question 1124
Which measurable state would demonstrate the fault was resolved? A field team inserts a long-reach optic into a short multimode path and observes intermittent receive-power alarms.
- Only required service VLANs cross the link and unrequested laboratory broadcasts are absent.
- A stable loop-free logical topology forms and broadcast counters return toward baseline.
- The link remains stable within receive-power limits under representative traffic and temperature.
- Link restoration makes the Ethernet interface operational and the application succeeds without changing HTTP content.
Explanation
Correct Answer
C:The link remains stable within receive-power limits under representative traffic and temperature. Corresponding action: Select a supported optic and fiber type with an appropriate wavelength, distance and optical budget.
Incorrect Answers
A:That observation verifies a different fault (A server rack trunk carries every lab VLAN although only two production VLANs are needed on its uplink.). For the question at hand, verify: The link remains stable within receive-power limits under representative traffic and temperature.
B:That observation verifies a different fault (Two access switches are linked by a second unplanned Ethernet cable and broadcast traffic begins multiplying across the building.). For the question at hand, verify: The link remains stable within receive-power limits under representative traffic and temperature.
D:That observation verifies a different fault (An inventory application sends correct HTTP requests, but an operator blames its Layer 7 data when the distribution uplink has no physical signal.). For the question at hand, verify: The link remains stable within receive-power limits under representative traffic and temperature.
Question 1125
Which THREE conclusions correctly align remedy, principle and evidence for this situation? A monitoring station polls switch counters via SNMPv2c using a default community string discoverable by guest clients.
- Action: Replace the shared-media hub with switched Ethernet access or isolate its half-duplex collision domain.
- Verification: Off-subnet destinations follow the expected route while direct connected networks stay reachable.
- Principle: SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.
- Verification: Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data.
- Unsafe shortcut: Publish a read-write community string on the student portal for easier monitoring.
- Action: Restrict the management plane and where supported migrate to SNMPv3 authenticated and encrypted monitoring.
Explanation
Correct Answers
C:Principle: SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections. This causal networking concept connects the intervention and outcome.
D:Verification: Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data. SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.
F:Action: Restrict the management plane and where supported migrate to SNMPv3 authenticated and encrypted monitoring. SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.
Incorrect Answers
A:This remedy fits a different fault (An operator adds a repeater-style hub behind a managed switch and expects independent full-duplex Ethernet per hub port.). For this case use: Restrict the management plane and where supported migrate to SNMPv3 authenticated and encrypted monitoring.
B:This is validation for another condition (A local VLAN can reach its own gateway but cannot reach outside prefixes because the core routing table lacks a default path.). Here verify: Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data.
E:This is not a supported or safe intervention in this scenario. SNMPv2c community strings provide weak shared-secret access without SNMPv3 privacy protections.
Question 1126
An HPE Aruba Networking switch operator observes this condition: A new uplink is physically patched into port 1/1/48 but the running configuration still describes it as a decommissioned printer. What action BEST addresses the fault?
- Use show interface extended counters and optical or copper diagnostics to localize the physical error cause.
- Configure supported native VLAN and tagging behavior and restrict allowed VLANs according to the approved trunk design.
- Compare relevant sections of the effective running configuration to the approved baseline and test expected enforcement.
- Update the interface description and asset/cable record while validating actual operational connection.
Explanation
Correct Answer
D:Update the interface description and asset/cable record while validating actual operational connection. Documented interface descriptions aid operations but do not replace actual port discovery and verification. Verified result: Topology inventory matches physical cable endpoints and operations can identify the uplink correctly.
Incorrect Answers
A:This change serves a different network condition (An aggregation link sporadically drops packets but staff check only the logical VLAN table.), not the issue described. Appropriate response here: Update the interface description and asset/cable record while validating actual operational connection.
B:This change serves a different network condition (An access-uplink trunk unexpectedly accepts untagged traffic into VLAN 1 when policy requires management VLAN 30 to be explicitly tagged.), not the issue described. Appropriate response here: Update the interface description and asset/cable record while validating actual operational connection.
C:This change serves a different network condition (A remote change to an access switch unexpectedly removes a security filter and the team has no postchange verification checklist.), not the issue described. Appropriate response here: Update the interface description and asset/cable record while validating actual operational connection.
Question 1127
Which evidence should be examined FIRST to localize this switch-related fault? A wiring closet must remain operational through one PSU failure but planners count two outlet sockets as redundant internal PSUs.
- Check model port types, supported optics matrix, distance and optical budget.
- Inspect platform PSU inventory, power paths, feed circuits and controlled PSU test.
- Inspect archive history, protected credentials, hashes, restoration trial and change identifier.
- Inspect transceiver inventory, supported SKU list, interface negotiation and diagnostics.
Explanation
Correct Answer
B:Inspect platform PSU inventory, power paths, feed circuits and controlled PSU test. Power resilience depends on actual PSU and feed architecture rather than just multiple electrical outlets. Next step: Select a switch with supported redundant power capacity and independent suitable AC distribution.
Incorrect Answers
A:Check model port types, supported optics matrix, distance and optical budget. This diagnostic addresses another network condition (A campus core requires a long fiber run but procurement supplies copper-only switch modules with no usable optical interface.). Here inspect: Inspect platform PSU inventory, power paths, feed circuits and controlled PSU test.
C:Inspect archive history, protected credentials, hashes, restoration trial and change identifier. This diagnostic addresses another network condition (An administrator makes weekly ad hoc switch configuration exports but cannot identify which file matches the last known healthy version.). Here inspect: Inspect platform PSU inventory, power paths, feed circuits and controlled PSU test.
D:Inspect transceiver inventory, supported SKU list, interface negotiation and diagnostics. This diagnostic addresses another network condition (A branch uses an RJ-45 SFP that requires host support but procurement assumes every optical SFP slot accepts all copper modules.). Here inspect: Inspect platform PSU inventory, power paths, feed circuits and controlled PSU test.
Question 1128
What observed result BEST validates the change in this wired network case? A monitoring station polls switch counters via SNMPv2c using a default community string discoverable by guest clients.
- Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data.
- The link remains stable within receive-power limits under representative traffic and temperature.
- Tagged VLAN35 frames cross the uplink and tenant VLANs not on the allowed list remain blocked.
- The bundle has matching members and no individual interfaces create accidental parallel Layer 2 paths.
Explanation
Correct Answer
A:Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data. Corresponding action: Restrict the management plane and where supported migrate to SNMPv3 authenticated and encrypted monitoring.
Incorrect Answers
B:That observation verifies a different fault (A field team inserts a long-reach optic into a short multimode path and observes intermittent receive-power alarms.). For the question at hand, verify: Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data.
C:That observation verifies a different fault (An uplink passes VLAN 10 but not the newly created VLAN 35 because the trunk allowed list was never updated.). For the question at hand, verify: Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data.
D:That observation verifies a different fault (An upstream device forms a static bundle but the downstream AOS-CX switch expects LACP PDUs to negotiate members.). For the question at hand, verify: Approved monitors retrieve scoped counters while unknown guest endpoints cannot query management data.
Question 1129
An AOS-CX learner investigates: Three new closet switches retain identical factory hostnames, causing logs and monitoring alerts to refer to an ambiguous node. What underlying concept should guide the response?
- LAG logical up status alone does not prove all physical member links are contributing.
- MSTP can map VLANs into multiple logical spanning-tree instances to distribute paths safely.
- Inter-VLAN routing requires the correct SVI address, operational VLAN and Layer 3 forwarding.
- Unique management identities reduce troubleshooting and change-control errors across similar devices.
Explanation
Correct Answer
D:Unique management identities reduce troubleshooting and change-control errors across similar devices. Appropriate intervention: Assign unique descriptive device hostnames using supported configuration commands and update asset inventory.
Incorrect Answers
A:This concept applies to another switch problem (A two-member uplink LAG carries traffic but half the expected capacity is missing and only one physical member is active.). Unique management identities reduce troubleshooting and change-control errors across similar devices.
B:This concept applies to another switch problem (A two-building deployment wants separate spanning-tree paths for user and voice VLANs but maps all VLANs into one MST instance.). Unique management identities reduce troubleshooting and change-control errors across similar devices.
C:This concept applies to another switch problem (An engineer creates VLAN70 on a Layer 3 AOS-CX switch but puts the gateway address on the wrong VLAN SVI.). Unique management identities reduce troubleshooting and change-control errors across similar devices.
Question 1130
A wired network administrator encounters: A technician issues a VLAN configuration command from the operator context and interprets the rejection as a missing hardware capability. Which configuration or response is MOST appropriate?
- Use supported AOS-CX model-driven operational and configuration interfaces with documented consistency and backup procedures.
- Verify the feature and management-license requirements against the precise model, release and intended deployment.
- Use the appropriate manager/configuration context and supported privilege for that command without bypassing RBAC.
- Confirm account entitlement, device association, management routing and supported Central connectivity prerequisites.
Explanation
Correct Answer
C:Use the appropriate manager/configuration context and supported privilege for that command without bypassing RBAC. CLI execution context and user role determine available commands independently of physical port capability. Verified result: The intended VLAN configuration succeeds only for authorized users, and operator read-only commands remain limited.
Incorrect Answers
A:This change serves a different network condition (A switch operator expects a traditional one-shot text file to be the only source of structured switch state used by automation.), not the issue described. Appropriate response here: Use the appropriate manager/configuration context and supported privilege for that command without bypassing RBAC.
B:This change serves a different network condition (A proposal assumes all advanced software features are present on every Aruba CX platform with no subscription or model restriction.), not the issue described. Appropriate response here: Use the appropriate manager/configuration context and supported privilege for that command without bypassing RBAC.
D:This change serves a different network condition (A new AOS-CX switch has Layer 2 connectivity but never becomes visible in HPE Aruba Networking Central inventory.), not the issue described. Appropriate response here: Use the appropriate manager/configuration context and supported privilege for that command without bypassing RBAC.