HP HPE6-A85 Practice Test 77
Question 760
An Aruba campus technician is troubleshooting: A security system revokes a user's entitlement while the existing network session remains privileged. Which inspection BEST narrows the fault?
- Test primary server outage, fallback selection, and effective client roles.
- Inspect guest expiry, authentication logs, and active session treatment.
- Review identity groups, returned RADIUS attributes and ACL enforcement.
- Check active session identity, CoA event, and post-change access tests.
Explanation
Correct Answer
D:Check active session identity, CoA event, and post-change access tests. Authorization can change during a session and may require explicit signaling to network equipment. Next action: Apply a supported reauthorization or Change of Authorization mechanism with safe identity validation.
Incorrect Answers
A:Test primary server outage, fallback selection, and effective client roles. This diagnostic applies to another failure (A campus site loses all wired access when one RADIUS node is taken offline for maintenance.). For the stated problem inspect: Check active session identity, CoA event, and post-change access tests.
B:Inspect guest expiry, authentication logs, and active session treatment. This diagnostic applies to another failure (A visitor's temporary login continues authenticating after the documented end of a conference.). For the stated problem inspect: Check active session identity, CoA event, and post-change access tests.
C:Review identity groups, returned RADIUS attributes and ACL enforcement. This diagnostic applies to another failure (A vendor contractor authenticates correctly but can access employee payroll applications.). For the stated problem inspect: Check active session identity, CoA event, and post-change access tests.
Question 761
Which networking principle BEST explains the proper response to this campus access scenario? An edge router shows its BGP neighbor in Idle after a peer IP address change.
- A default route is used when no more-specific route matches the destination.
- BGP neighbors use configured peers and TCP reachability with matching autonomous-system parameters.
- IPv6 link-local next hops may require an explicit interface to resolve ambiguity.
- A directly connected route generally depends on an active interface with valid addressing.
Explanation
Correct Answer
B:BGP neighbors use configured peers and TCP reachability with matching autonomous-system parameters. Targeted action: Verify peer reachability, local and remote ASN, source address and configured neighbor target.
Incorrect Answers
A:A default route is used when no more-specific route matches the destination. This technical principle belongs to a different campus condition (A branch gateway reaches local VLANs but has no route for internet destinations.). For this case: BGP neighbors use configured peers and TCP reachability with matching autonomous-system parameters.
C:IPv6 link-local next hops may require an explicit interface to resolve ambiguity. This technical principle belongs to a different campus condition (An IPv6-only management subnet needs a route through a link-local next hop.). For this case: BGP neighbors use configured peers and TCP reachability with matching autonomous-system parameters.
D:This technical principle belongs to a different campus condition (A routing device has an SVI for VLAN 30 but no directly connected 192.0.2.0/24 route appears.). BGP neighbors use configured peers and TCP reachability with matching autonomous-system parameters.
Question 762
An Aruba campus technician is troubleshooting: A corridor laptop reports -82 dBm RSSI and frequent disconnects at an application-critical location. Which inspection BEST narrows the fault?
- Measure RSSI, noise, SNR, and client retransmissions along the corridor.
- Inspect client roam history, RSSI trend, and voice packet loss.
- Inspect role/VLAN assignment, DHCP offers, and switch or gateway forwarding.
- Inspect antenna orientation, mounting specifications, and client survey data.
Explanation
Correct Answer
A:Measure RSSI, noise, SNR, and client retransmissions along the corridor. Received signal strength indicates power at a client but is not an absolute measure of service quality. Next action: Review AP placement and antenna coverage to improve measured signal at the actual client position.
Incorrect Answers
B:Inspect client roam history, RSSI trend, and voice packet loss. This diagnostic applies to another failure (Mobile voice handsets cling to a distant AP while walking past several healthier access points.). For the stated problem inspect: Measure RSSI, noise, SNR, and client retransmissions along the corridor.
C:Inspect role/VLAN assignment, DHCP offers, and switch or gateway forwarding. This diagnostic applies to another failure (Clients authenticate to the guest SSID but obtain addresses from the staff VLAN.). For the stated problem inspect: Measure RSSI, noise, SNR, and client retransmissions along the corridor.
D:Inspect antenna orientation, mounting specifications, and client survey data. This diagnostic applies to another failure (A directional antenna mounted backwards leaves the intended loading dock poorly covered.). For the stated problem inspect: Measure RSSI, noise, SNR, and client retransmissions along the corridor.
Question 763
An associate technician reports: A campus uplink uses single-mode optics connected across a short patch of unsuitable multimode fiber. Which response MOST directly corrects the issue?
- Size backup power for switch plus PoE load and documented availability target.
- Validate port, fiber pair, and failure-domain mapping against the low-level design.
- Execute a site acceptance plan for addressing, authentication, routing, Wi-Fi, and resilience.
- Match transceiver wavelength, reach, and fiber type against the approved optical design.
Explanation
Correct Answer
D:Match transceiver wavelength, reach, and fiber type against the approved optical design. Optical link compatibility requires matching transceiver and fiber characteristics. Verification: The interface operates without optical alarms or error bursts using matched media.
Incorrect Answers
A:This action applies to a different case (The IDF includes PoE switches supporting voice phones but the UPS runtime covers only a few minutes.), not the reported condition. Targeted correction: Match transceiver wavelength, reach, and fiber type against the approved optical design.
B:This action applies to a different case (An IDF patching plan allocates two critical uplinks to the same physical fiber tray without separation.), not the reported condition. Targeted correction: Match transceiver wavelength, reach, and fiber type against the approved optical design.
C:This action applies to a different case (A new campus segment is handed over because every switch is powered on, without any user flow testing.), not the reported condition. Targeted correction: Match transceiver wavelength, reach, and fiber type against the approved optical design.
Question 764
For this HPE6-A85 network scenario, which response should be REJECTED? Slow legacy clients dominate a shared channel and reduce effective throughput for newer devices.
- Increase SSID count and assume slow clients cannot affect others anymore.
- Check DHCP and DNS service stages separately from Wi-Fi association.
- Review routing convergence and spanning-tree stability after a link failure.
- Review both permitted and prohibited traffic after changing security policy.
Explanation
Correct Answer
A:Increase SSID count and assume slow clients cannot affect others anymore. Shared Wi-Fi capacity depends on transmission airtime, not only client bit rate. Safer action: Review supported airtime policy and basic rate settings with compatibility testing.
Incorrect Answers
B:Check DHCP and DNS service stages separately from Wi-Fi association. Client onboarding spans distinct layers. Specific remediation: Review supported airtime policy and basic rate settings with compatibility testing.
C:Review routing convergence and spanning-tree stability after a link failure. Physical redundancy alone does not guarantee logical failover. Specific remediation: Review supported airtime policy and basic rate settings with compatibility testing.
D:Review both permitted and prohibited traffic after changing security policy. Negative tests help detect unintended privilege escalation. Specific remediation: Review supported airtime policy and basic rate settings with compatibility testing.
Question 765
Which THREE claims correctly connect cause, correction and verification for this campus case? A device installation report claims completion with only screenshots of the chassis LEDs.
- Unsafe shortcut: Use a power LED as the sole basis for accepting campus LAN security and redundancy.
- Principle: Production-readiness evidence must prove user services beyond physical power status.
- Action: Validate switch management, uplinks, segmentation, power and failover with documented test cases.
- Verification: The installation acceptance record includes verified end-to-end service evidence.
- Verification: New switches consistently apply shared policy while preserving unique site parameters.
- Action: Verify link speeds and adjust documented spanning-tree path metrics if required.
Explanation
Correct Answers
B:Principle: Production-readiness evidence must prove user services beyond physical power status. This principle connects the correction with the expected evidence.
C:Action: Validate switch management, uplinks, segmentation, power and failover with documented test cases. Production-readiness evidence must prove user services beyond physical power status.
D:Verification: The installation acceptance record includes verified end-to-end service evidence. Production-readiness evidence must prove user services beyond physical power status.
Incorrect Answers
A:Unsafe shortcut: Use a power LED as the sole basis for accepting campus LAN security and redundancy. Production-readiness evidence must prove user services beyond physical power status. Safer action: Validate switch management, uplinks, segmentation, power and failover with documented test cases.
E:Verification: New switches consistently apply shared policy while preserving unique site parameters. This test belongs to another problem (Several identical access switches are configured manually and drift on VLAN names and port protection.). Here verify: The installation acceptance record includes verified end-to-end service evidence.
F:Action: Verify link speeds and adjust documented spanning-tree path metrics if required. This intervention targets a different network condition (Two redundant campus uplinks are healthy but traffic chooses a lower-bandwidth path contrary to design.). Here use: Validate switch management, uplinks, segmentation, power and failover with documented test cases.
Question 766
After the recommended correction, which observation would BEST confirm success? A stacked access-switch pair loses its interconnect and management views show inconsistent members.
- Switch, gateway and AP event timestamps stay aligned after primary source failure.
- Both members recover coherent stacking identity and expected forwarding state.
- The standby router assumes the shared gateway with permitted client traffic continuity.
- Admin logins work from approved hosts while guest requests are denied and logged.
Explanation
Correct Answer
B:Both members recover coherent stacking identity and expected forwarding state. Appropriate action: Inspect stacking topology, split-detection design, and physical stack links before restoring service.
Incorrect Answers
A:Switch, gateway and AP event timestamps stay aligned after primary source failure. This observation would support a different case (Network device logs disagree by several minutes after the only NTP peer fails.), rather than the current problem. Required evidence: Both members recover coherent stacking identity and expected forwarding state.
C:This observation would support a different case (A subnet uses a virtual default gateway, but clients lose service when the active router is powered off.), rather than the current problem. Required evidence: Both members recover coherent stacking identity and expected forwarding state.
D:Admin logins work from approved hosts while guest requests are denied and logged. This observation would support a different case (A campus switch management web UI is exposed to the entire guest VLAN.), rather than the current problem. Required evidence: Both members recover coherent stacking identity and expected forwarding state.
Question 767
After the recommended correction, which observation would BEST confirm success? An auditorium AP uses 80 MHz in crowded 5 GHz spectrum and clients have high interference.
- Outdoor coverage meets planned boundaries without regulatory or interference issues.
- The SSID is available throughout the approved service window.
- Measured airtime contention falls with acceptable capacity for the expected client count.
- Wireless clients receive intended addresses and can reach assigned network resources.
Explanation
Correct Answer
C:Measured airtime contention falls with acceptable capacity for the expected client count. This outcome verifies the targeted campus correction. Appropriate action: Evaluate narrowing channel width and distributing AP channel assignments for measured density.
Incorrect Answers
A:Outdoor coverage meets planned boundaries without regulatory or interference issues. This observation would support a different case (The outdoor AP group inherited indoor transmit-power and channel settings from a generic template.), rather than the current problem. Required evidence: Measured airtime contention falls with acceptable capacity for the expected client count.
B:This observation would support a different case (A required campus SSID is configured but hidden under a WLAN schedule that disables it during office hours.), rather than the current problem. Required evidence: Measured airtime contention falls with acceptable capacity for the expected client count.
D:This observation would support a different case (Employee Wi-Fi connects and authenticates but clients receive no IP address after a guest VLAN redesign.), rather than the current problem. Required evidence: Measured airtime contention falls with acceptable capacity for the expected client count.
Question 768
What technical principle underpins the correct intervention for this issue? A switch team proposes using a MAC address allow list as the only corporate identity proof.
- MAC addresses are observable and spoofable and should not be treated as strong identity secrets.
- RADIUS authentication and accounting serve different but complementary audit functions.
- Guest authorization must be distinct from employee policy and time bounded.
- Encryption of a radio link does not replace internal authorization and segmentation.
Explanation
Correct Answer
A:MAC addresses are observable and spoofable and should not be treated as strong identity secrets. Targeted action: Combine appropriate 802.1X identity or policy controls with MAC checks as limited signals.
Incorrect Answers
B:RADIUS authentication and accounting serve different but complementary audit functions. This technical principle belongs to a different campus condition (A security investigation cannot correlate wireless users with session start/stop despite successful authentication.). For this case: MAC addresses are observable and spoofable and should not be treated as strong identity secrets.
C:Guest authorization must be distinct from employee policy and time bounded. This technical principle belongs to a different campus condition (A sponsored guest account receives permanent unrestricted employee access after portal registration.). For this case: MAC addresses are observable and spoofable and should not be treated as strong identity secrets.
D:This technical principle belongs to a different campus condition (A campus security plan relies only on Wi-Fi encryption and has no internal wired policy separation.). MAC addresses are observable and spoofable and should not be treated as strong identity secrets.
Question 769
Which networking principle BEST explains the proper response to this campus access scenario? A capture on a trunk port shows an 802.1Q tag while the IP packet header remains unchanged.
- An IP TTL or hop limit prevents packets from circulating indefinitely in routing loops.
- OSI Layer 1 concerns transmission over physical media rather than network addressing.
- VLAN tags are Layer 2 frame metadata rather than fields in the IP header.
- OSI Layer 3 makes forwarding decisions based on network-layer addressing and routing.
Explanation
Correct Answer
C:VLAN tags are Layer 2 frame metadata rather than fields in the IP header. Targeted action: Distinguish Ethernet VLAN encapsulation from the routed IP header when reading packet traces.
Incorrect Answers
A:An IP TTL or hop limit prevents packets from circulating indefinitely in routing loops. This technical principle belongs to a different campus condition (A traceroute repeatedly reports routing-loop hops before packets are discarded.). For this case: VLAN tags are Layer 2 frame metadata rather than fields in the IP header.
B:This technical principle belongs to a different campus condition (A remote campus uplink shows no link light despite correct IP configuration on both switches.). VLAN tags are Layer 2 frame metadata rather than fields in the IP header.
D:This technical principle belongs to a different campus condition (A laptop reaches its switch but cannot access a server in another IP network.).
Question 770
Which networking principle BEST explains the proper response to this campus access scenario? Users report slow application loading but the UXI wireless association step succeeds.
- End-to-end UXI diagnostics can isolate service layers beyond RF association.
- Syslog severity filters and destinations determine which events operations can observe.
- SNMP telemetry access depends on matching security credentials and allowed collectors.
- Monitoring scope determines whether aggregate health metrics are attributable.
Explanation
Correct Answer
A:End-to-end UXI diagnostics can isolate service layers beyond RF association. Targeted action: Review UXI DNS response and application connectivity test stages separately.
Incorrect Answers
B:Syslog severity filters and destinations determine which events operations can observe. This technical principle belongs to a different campus condition (A switch forwards link up/down messages but suppresses critical hardware alarms in Central operations.). For this case: End-to-end UXI diagnostics can isolate service layers beyond RF association.
C:SNMP telemetry access depends on matching security credentials and allowed collectors. This technical principle belongs to a different campus condition (An NOC dashboard stops displaying interface bandwidth after a switch SNMP credential rotation.). For this case: End-to-end UXI diagnostics can isolate service layers beyond RF association.
D:Monitoring scope determines whether aggregate health metrics are attributable. This technical principle belongs to a different campus condition (A dashboard incorrectly combines branch site alarms with campus headquarters metrics.). For this case: End-to-end UXI diagnostics can isolate service layers beyond RF association.