Question 300
A new replacement is visible in discovery but its ports do not receive policy because it is pending authorization. Which FortiSwitch configuration or corrective action BEST addresses the requirement?
Explanation
Correct Answer
Authorize only intended discovered FortiSwitch serial numbers and confirm management mode after the expected transition. Switch discovery is not the same as authorization; auto-authorization has governance implications and a managed-mode transition may reboot the device. Verify the action with: Review discovered/authorized controller inventory, switch serial, link state, approval method, reboot status and firmware compatibility.
Incorrect Answers
Set measured storm-control thresholds for broadcast, multicast or unknown unicast as supported and validate needed discovery protocols. This action is relevant to Storm-control thresholds and broadcast containment, not the controlling requirement in this case. Overaggressive storm control can break DHCP, ARP or group discovery even when physical links remain healthy. The targeted response is: Authorize only intended discovered FortiSwitch serial numbers and confirm management mode after the expected transition.
Permit shared FortiSwitch hardware across VDOMs only with verified port and feature support and explicit tenant VLAN tagging. This action is relevant to Shared port multi-VDOM policy boundaries, not the controlling requirement in this case. Shared physical ports can support some per-port controls across VDOMs, but feature support and tagging must be checked for the exact release. The targeted response is: Authorize only intended discovered FortiSwitch serial numbers and confirm management mode after the expected transition.
Use supported FortiLink point-to-point L2 or Layer-3 transport configuration and validate discovery and control traffic end to end. This action is relevant to FortiLink transport over nontrivial L2 or L3 paths, not the controlling requirement in this case. FortiLink over intermediate networks requires topology-specific settings; ordinary IP reachability alone does not establish FortiLink discovery. The targeted response is: Authorize only intended discovered FortiSwitch serial numbers and confirm management mode after the expected transition.