CompTIA 220-1202 Practice Test 59
Question 580
At Elmwood Legal, a PC shuts off under sustained CPU load without a blue screen. Evidence: Thermal or power issue may manifest as OS shutdown. The support goal is to collect thermal and power evidence before applying software patches. What operational signal should the support team monitor for regression or a return of the issue?
- Monitor logon-duration events
- Monitor boot repair logs and disk failures
- Monitor CPU temperature and unexpected power events
- Monitor clock drift and failed time service
Explanation
Correct Answer
C:
Monitor CPU temperature and unexpected power events. The case states that thermal or power issue may manifest as OS shutdown. In the monitor stage, this action directly supports the required outcome: collect thermal and power evidence before applying software patches.
Incorrect Answers
A:
Monitor logon-duration events. That step targets Windows startup slow profile when profile scripts and mapped resources may be timing out. The current situation instead says thermal or power issue may manifest as OS shutdown, and the goal is to collect thermal and power evidence before applying software patches.
B:
Monitor boot repair logs and disk failures. That step targets Windows startup repair boot records when firmware can see the disk but Windows does not boot. The current situation instead says thermal or power issue may manifest as OS shutdown, and the goal is to collect thermal and power evidence before applying software patches.
D:
Monitor clock drift and failed time service. That step targets Windows time drift authentication failure when kerberos authentication is sensitive to time skew. The current situation instead says thermal or power issue may manifest as OS shutdown, and the goal is to collect thermal and power evidence before applying software patches.
Question 581
At Ashwood Design, windows becomes unresponsive while many browser tabs run. Evidence: Task Manager shows memory nearly exhausted and heavy paging. The support goal is to address the identified memory consumer before reinstall. The technician must identify the likely cause before changing configuration or user data. Which first investigation best establishes what is wrong?
- Inspect committed memory, processes and pagefile use
- Inspect event logs, thermals and power readings
- Inspect disk activity with Resource Monitor and SMART status
- Inspect crash module, app version and vendor support list
Explanation
Correct Answer
A:
Inspect committed memory, processes and pagefile use. The case states that task Manager shows memory nearly exhausted and heavy paging. In the diagnose stage, this action directly supports the required outcome: address the identified memory consumer before reinstall.
Incorrect Answers
B:
Inspect event logs, thermals and power readings. That step targets Windows random shutdown thermal when thermal or power issue may manifest as OS shutdown. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
C:
Inspect disk activity with Resource Monitor and SMART status. That step targets Windows 100 percent disk activity when background indexing or failing storage can drive I/O. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
D:
Inspect crash module, app version and vendor support list. That step targets Windows application crash after upgrade when the app has an older unsupported dependency. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
Question 582
At Greenwood Media, windows becomes unresponsive while many browser tabs run. Evidence: Task Manager shows memory nearly exhausted and heavy paging. The support goal is to address the identified memory consumer before reinstall. Which corrective or preventative action best addresses this requirement while retaining appropriate access and change controls?
- Repair verified source of I/O, preserve backup if disk health is poor
- Repair appropriate component or approved driver dependency
- Close/repair runaway apps and adjust memory plan if justified
- Use supported startup repair for damaged boot records
Explanation
Correct Answer
C:
Close/repair runaway apps and adjust memory plan if justified. The case states that task Manager shows memory nearly exhausted and heavy paging. In the design stage, this action directly supports the required outcome: address the identified memory consumer before reinstall.
Incorrect Answers
A:
Repair verified source of I/O, preserve backup if disk health is poor. That step targets Windows 100 percent disk activity when background indexing or failing storage can drive I/O. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
B:
Repair appropriate component or approved driver dependency. That step targets failed Windows service after patch when event Viewer shows a dependency error. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
D:
Use supported startup repair for damaged boot records. That step targets Windows startup repair boot records when firmware can see the disk but Windows does not boot. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
Question 583
At Monarch Energy, windows becomes unresponsive while many browser tabs run. Evidence: Task Manager shows memory nearly exhausted and heavy paging. The support goal is to address the identified memory consumer before reinstall. Which bounded nonproduction test best checks the proposed solution before wider deployment?
- Use a VM snapshot to reproduce driver update and rollback
- Test old and supported builds in disposable Windows VM
- Reproduce controlled memory load in test VM
- Upgrade a VM snapshot then test rollback
Explanation
Correct Answer
C:
Reproduce controlled memory load in test VM. The case states that task Manager shows memory nearly exhausted and heavy paging. In the pilot stage, this action directly supports the required outcome: address the identified memory consumer before reinstall.
Incorrect Answers
A:
Use a VM snapshot to reproduce driver update and rollback. That step targets Windows BSOD after driver change when the failures started immediately after the driver update. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
B:
Test old and supported builds in disposable Windows VM. That step targets Windows application crash after upgrade when the app has an older unsupported dependency. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
D:
Upgrade a VM snapshot then test rollback. That step targets Windows update rollback issue when the update changed drivers or services. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
Question 584
At Evergreen Operations, windows becomes unresponsive while many browser tabs run. Evidence: Task Manager shows memory nearly exhausted and heavy paging. The support goal is to address the identified memory consumer before reinstall. Which result would most convincingly show the support requirement has been satisfied?
- The target account signs in within agreed time without losing data
- Domain sign-in succeeds with correct time
- Response time improves without process crashes
- Normal I/O returns without data loss
Explanation
Correct Answer
C:
Response time improves without process crashes. The case states that task Manager shows memory nearly exhausted and heavy paging. In the validate stage, this action directly supports the required outcome: address the identified memory consumer before reinstall.
Incorrect Answers
A:
Target account signs in within agreed time without losing data. That step targets Windows startup slow profile when profile scripts and mapped resources may be timing out. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
B:
Domain sign-in succeeds with correct time. That step targets Windows time drift authentication failure when kerberos authentication is sensitive to time skew. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
D:
Normal I/O returns without data loss. That step targets Windows 100 percent disk activity when background indexing or failing storage can drive I/O. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
Question 585
At Coral Bay Partners, windows becomes unresponsive while many browser tabs run. Evidence: Task Manager shows memory nearly exhausted and heavy paging. The support goal is to address the identified memory consumer before reinstall. What operational signal should the support team monitor for regression or a return of the issue?
- Monitor boot repair logs and disk failures
- Monitor working set growth and paging
- Monitor clock drift and failed time service
- Monitor repeat update attempts and support deadlines
Explanation
Correct Answer
B:
Monitor working set growth and paging. The case states that task Manager shows memory nearly exhausted and heavy paging. In the monitor stage, this action directly supports the required outcome: address the identified memory consumer before reinstall.
Incorrect Answers
A:
Monitor boot repair logs and disk failures. That step targets Windows startup repair boot records when firmware can see the disk but Windows does not boot. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
C:
Monitor clock drift and failed time service. That step targets Windows time drift authentication failure when kerberos authentication is sensitive to time skew. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
D:
Monitor repeat update attempts and support deadlines. That step targets Windows update rollback issue when the update changed drivers or services. The current situation instead says task Manager shows memory nearly exhausted and heavy paging, and the goal is to address the identified memory consumer before reinstall.
Question 586
At Horizon Accounting, a print-related Windows service fails to start after cumulative update. Evidence: Event Viewer shows a dependency error. The support goal is to diagnose service dependency rather than reset the PC. The technician must identify the likely cause before changing configuration or user data. Which first investigation best establishes what is wrong?
- Check update history, event logs and rollback eligibility
- Compare affected and unaffected logon events and GPO scripts
- Check Services snap-in, dependent services and error ID
- Inspect event logs, thermals and power readings
Explanation
Correct Answer
C:
Check Services snap-in, dependent services and error ID. The case states that event Viewer shows a dependency error. In the diagnose stage, this action directly supports the required outcome: diagnose service dependency rather than reset the PC.
Incorrect Answers
A:
Check update history, event logs and rollback eligibility. That step targets Windows update rollback issue when the update changed drivers or services. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
B:
Compare affected and unaffected logon events and GPO scripts. That step targets Windows startup slow profile when profile scripts and mapped resources may be timing out. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
D:
Inspect event logs, thermals and power readings. That step targets Windows random shutdown thermal when thermal or power issue may manifest as OS shutdown. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
Question 587
At Golden Gate Training, a print-related Windows service fails to start after cumulative update. Evidence: Event Viewer shows a dependency error. The support goal is to diagnose service dependency rather than reset the PC. Which corrective or preventative action best addresses this requirement while retaining appropriate access and change controls?
- Fix stale mapped resources or damaged profile component
- Roll back or replace the implicated driver with a supported version
- Repair appropriate component or approved driver dependency
- Use supported startup repair for damaged boot records
Explanation
Correct Answer
C:
Repair appropriate component or approved driver dependency. The case states that event Viewer shows a dependency error. In the design stage, this action directly supports the required outcome: diagnose service dependency rather than reset the PC.
Incorrect Answers
A:
Fix stale mapped resources or damaged profile component. That step targets Windows startup slow profile when profile scripts and mapped resources may be timing out. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
B:
Roll back or replace the implicated driver with a supported version. That step targets Windows BSOD after driver change when the failures started immediately after the driver update. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
D:
Use supported startup repair for damaged boot records. That step targets Windows startup repair boot records when firmware can see the disk but Windows does not boot. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
Question 588
At Westfield Community Services, a print-related Windows service fails to start after cumulative update. Evidence: Event Viewer shows a dependency error. The support goal is to diagnose service dependency rather than reset the PC. Which bounded nonproduction test best checks the proposed solution before wider deployment?
- Try the app against permitted lab endpoint
- Start service on patched lab image after repairing dependency
- Alter a lab client clock then resync
- Connect mock USB peripherals across ports in lab
Explanation
Correct Answer
B:
Start service on patched lab image after repairing dependency. The case states that event Viewer shows a dependency error. In the pilot stage, this action directly supports the required outcome: diagnose service dependency rather than reset the PC.
Incorrect Answers
A:
Try the app against permitted lab endpoint. That step targets Windows network stack application fault when only one app is affected, suggesting local app proxy or firewall policy. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
C:
Alter a lab client clock then resync. That step targets Windows time drift authentication failure when kerberos authentication is sensitive to time skew. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
D:
Connect mock USB peripherals across ports in lab. That step targets Windows USB resource warning when multiple high-bandwidth devices share a USB controller. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
Question 589
At Crescent Bay Finance, a print-related Windows service fails to start after cumulative update. Evidence: Event Viewer shows a dependency error. The support goal is to diagnose service dependency rather than reset the PC. Which result would most convincingly show the support requirement has been satisfied?
- Spooler or target service stays running and required functionality works
- Target account signs in within agreed time without losing data
- App reaches service without disabling host firewall globally
- App launches and main workflow completes
Explanation
Correct Answer
A:
Spooler or target service stays running and required functionality works. The case states that event Viewer shows a dependency error. In the validate stage, this action directly supports the required outcome: diagnose service dependency rather than reset the PC.
Incorrect Answers
B:
Target account signs in within agreed time without losing data. That step targets Windows startup slow profile when profile scripts and mapped resources may be timing out. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
C:
App reaches service without disabling host firewall globally. That step targets Windows network stack application fault when only one app is affected, suggesting local app proxy or firewall policy. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
D:
App launches and main workflow completes. That step targets Windows application crash after upgrade when the app has an older unsupported dependency. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
Question 590
At Blue Ridge Systems, a print-related Windows service fails to start after cumulative update. Evidence: Event Viewer shows a dependency error. The support goal is to diagnose service dependency rather than reset the PC. What operational signal should the support team monitor for regression or a return of the issue?
- Track app event errors after OS updates
- Watch repeated service failures after updates
- Monitor recurring BSOD codes and driver updates
- Monitor boot repair logs and disk failures
Explanation
Correct Answer
B:
Watch repeated service failures after updates. The case states that event Viewer shows a dependency error. In the monitor stage, this action directly supports the required outcome: diagnose service dependency rather than reset the PC.
Incorrect Answers
A:
Monitor app event errors after OS updates. That step targets Windows application crash after upgrade when the app has an older unsupported dependency. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
C:
Monitor recurring BSOD codes and driver updates. That step targets Windows BSOD after driver change when the failures started immediately after the driver update. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.
D:
Monitor boot repair logs and disk failures. That step targets Windows startup repair boot records when firmware can see the disk but Windows does not boot. The current situation instead says event Viewer shows a dependency error, and the goal is to diagnose service dependency rather than reset the PC.