cert
cert-1
cert-2

Pass CompTIA 220-1201 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
220-1201 Exam - Verified By Experts
220-1201 Premium Bundle
$29.98

220-1201 Premium Bundle

$79.99
$109.97
  • Premium File 527 Questions & Answers. Last update: Nov 15, 2026
  • Training Course 106 Video Lectures
  • Study Guide 2615 Pages
 
$109.97
$79.99
accept 102 downloads in last 7 days
block-screenshots
Purchase CompTIA 220-1201 Exam Training Products Individually
CompTIA 220-1201 Premium File
Premium File 527 Q&A
$76.99$69.99
CompTIA 220-1201 Video Training Course
Training Course 106 Lectures
$21.99 $19.99
CompTIA 220-1201 PDF Study Guide
Study Guide 2615 Pages
$21.99 $19.99
CompTIA 220-1201 Practice Test 31

Question 300

On a service ticket for Horizon College, the team observes: An inkjet photo printer produces blank horizontal stripes in cyan images. The supporting record states that a nozzle check identifies missing cyan nozzles while the paper path is clear. The desired outcome is to correct an ink delivery issue rather than changing duplex settings. User data and business service continuity must be preserved. Which verification result supports the intended technical outcome?

  1. Verify dark print appears on the active coated side without consumable ink
  2. Verify cyan lines are continuous and color image banding is reduced
  3. Verify queued and new jobs print and the queue reports the device online
  4. Verify repeated marks are gone across consecutive pages

Explanation

Correct Answer

B:

Verify cyan lines are continuous and color image banding is reduced. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that a nozzle check identifies missing cyan nozzles while the paper path is clear. The support goal is to correct an ink delivery issue rather than changing duplex settings; this validate action specifically addresses inkjet horizontal banding and nozzle obstruction without confusing a different subsystem.

Incorrect Answers

A:

Verify dark print appears on the active coated side without consumable ink. This action is appropriate for thermal printer paper orientation, normally when a shipping label printer feeds paper but produces completely blank labels. Here the observed facts require inkjet horizontal banding and nozzle obstruction instead.

C:

Verify queued and new jobs print and the queue reports the device online. This action is appropriate for printer offline queue despite network availability, normally when a shared printer is reachable on the network but user jobs accumulate in an offline queue. Here the observed facts require inkjet horizontal banding and nozzle obstruction instead.

D:

Verify repeated marks are gone across consecutive pages. This action is appropriate for laser repeated streaks from drum defect, normally when printed laser pages have a dark stripe repeated at the same distance down each sheet. Here the observed facts require inkjet horizontal banding and nozzle obstruction instead.

Question 301

A support request at Amberline Finance presents this problem: A domain receives email at the wrong destination after DNS changes. The supporting record states that its MX record points to a decommissioned mail host while SPF TXT data still names authorized outbound senders. The desired outcome is to distinguish mail routing records from sender authorization policies. A safe non-destructive test must be used before replacing additional parts. Which safe pilot action gives the most relevant evidence?

  1. Change MX in a test zone and validate mail routing versus outbound SPF evaluation
  2. Renew the printer lease in a lab subnet after applying its reservation
  3. Query a known internal name on a test client with corrected DNS settings
  4. Pilot guest-to-payroll denial and an authorized remote VPN session independently

Explanation

Correct Answer

A:

Change MX in a test zone and validate mail routing versus outbound SPF evaluation. It tests the proposed solution safely on an approved representative system. The relevant observation is that its MX record points to a decommissioned mail host while SPF TXT data still names authorized outbound senders. The support goal is to distinguish mail routing records from sender authorization policies; this pilot action specifically addresses mx and spf dns records distinct purposes without confusing a different subsystem.

Incorrect Answers

B:

Renew the printer lease in a lab subnet after applying its reservation. This action is appropriate for dhcp reservation versus exclusion, normally when a networked printer must keep the same IPv4 address while the rest of the office remains DHCP-managed. Here the observed facts require mx and spf dns records distinct purposes instead.

C:

Query a known internal name on a test client with corrected DNS settings. This action is appropriate for dns resolution versus dhcp address assignment, normally when a workstation has a valid IPv4 address, gateway and lease but cannot reach services by hostname. Here the observed facts require mx and spf dns records distinct purposes instead.

D:

Pilot guest-to-payroll denial and an authorized remote VPN session independently. This action is appropriate for vlan segmentation versus vpn encrypted tunneling, normally when a small office needs guest Wi-Fi isolated from payroll devices but also needs secure remote employee access. Here the observed facts require mx and spf dns records distinct purposes instead.

Question 302

At Crescent Operations, a technician working in hardware and network incident triage identifies this issue: A computer reports no bootable operating system after a new secondary drive was added. The supporting record states that the original OS disk remains detected but firmware boot order points at the empty secondary disk. The desired outcome is to restore the intended boot entry without formatting healthy storage. A safe non-destructive test must be used before replacing additional parts. Which verification result supports the intended technical outcome?

  1. Verify interface CRC errors stop increasing and drive detection is consistent
  2. Verify the original system boots normally with both drives attached
  3. Verify firmware recognizes the correct drive capacity and health
  4. Verify the array returns to healthy state and files match known checksums

Explanation

Correct Answer

B:

Verify the original system boots normally with both drives attached. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that the original OS disk remains detected but firmware boot order points at the empty secondary disk. The support goal is to restore the intended boot entry without formatting healthy storage; this validate action specifically addresses uefi boot order after a second drive without confusing a different subsystem.

Incorrect Answers

A:

Verify interface CRC errors stop increasing and drive detection is consistent. This action is appropriate for intermittent sata cable data fault, normally when a SATA HDD disappears occasionally despite healthy spin-up and no clear media errors. Here the observed facts require uefi boot order after a second drive instead.

C:

Verify firmware recognizes the correct drive capacity and health. That action is appropriate for nvme ssd not detected after installation, normally when a new NVMe SSD is absent from firmware and the storage installer. Here the observed facts require uefi boot order after a second drive instead.

D:

Verify the array returns to healthy state and files match known checksums. That action is appropriate for degraded raid after a failed member, normally when a mirrored NAS reports one disk failed while files remain available. Here the observed facts require uefi boot order after a second drive instead.

Question 303

During Horizon College's laptop and mobile device repair, the technician encounters this condition: A wireless headset pairs with a tablet but does not appear on a new laptop's device discovery list. The supporting record states that the headset is still connected to the tablet and has not entered discoverable pairing mode. The desired outcome is to pair the intended audio accessory without erasing unrelated device settings. A safe non-destructive test must be used before replacing additional parts. What should support monitor to catch a recurrence of the same failure?

  1. Track pen battery, firmware and digitizer driver issues
  2. Monitor reconnection failures and the headset's remembered-device limit
  3. Track backup failures, replacement SSD health and encryption key escrow
  4. Track incompatible adapter purchases and port capability labeling

Explanation

Correct Answer

B:

Monitor reconnection failures and the headset's remembered-device limit. It tracks recurrence of the specific failure mechanism over time. The relevant observation is that the headset is still connected to the tablet and has not entered discoverable pairing mode. The support goal is to pair the intended audio accessory without erasing unrelated device settings; this monitor action specifically addresses bluetooth headset pairing without confusing a different subsystem.

Incorrect Answers

A:

Track pen battery, firmware and digitizer driver issues. This action is appropriate for active stylus digitizer compatibility, normally when a designer needs pen pressure and palm rejection on a convertible laptop. Here the observed facts require bluetooth headset pairing instead.

C:

Track backup failures, replacement SSD health and encryption key escrow. This action is appropriate for laptop ssd replacement and encryption, normally when a laptop SSD is failing SMART health checks and holds company data protected with full-disk encryption. Here the observed facts require bluetooth headset pairing instead.

D:

Track incompatible adapter purchases and port capability labeling. This action is appropriate for usb-c connector versus supported protocol, normally when a user assumes every laptop USB-C port can send video to a USB-C monitor. Here the observed facts require bluetooth headset pairing instead.

Question 304

On a service ticket for Lakeside Analytics, the team observes: A shared office laser device prints pale text even though paper feeds cleanly. The desired outcome is to identify toner depletion separately from inkjet printhead faults. The goal is to restore required function without creating a new security or safety problem. What should the technician verify first to establish the problem?

  1. Inspect nozzle test results, cartridge levels and printhead cleaning history
  2. Inspect application print preferences, default tray, media size and duplex capability
  3. Compare IPS and TN viewing-angle color shifts, calibration and target workload
  4. Check toner level, cartridge seating, toner-save mode and page examples

Explanation

Correct Answer

D:

Check toner level, cartridge seating, toner-save mode and page examples. It checks the likely failure boundary before altering working parts or settings. The relevant observation is that a shared office laser device prints pale text even though paper feeds cleanly. The support goal is to identify toner depletion separately from inkjet printhead faults; this diagnose action specifically addresses laser printer faded output and toner without confusing a different subsystem.

Incorrect Answers

A:

Inspect nozzle test results, cartridge levels and printhead cleaning history. This action is appropriate for inkjet printhead clogging, normally when an inkjet printer leaves missing color bands although cartridges contain ink. Here the observed facts require laser printer faded output and toner instead.

B:

Inspect application print preferences, default tray, media size and duplex capability. This action is appropriate for printer duplex and tray settings, normally when a network printer puts letter-size forms on the wrong paper and uses one-sided output. Here the observed facts require laser printer faded output and toner instead.

C:

Compare IPS and TN viewing-angle color shifts, calibration and target workload. This action is appropriate for ips versus tn versus oled displays, normally when a graphic designer prioritizes consistent viewing angles and color accuracy over lowest display price. Here the observed facts require laser printer faded output and toner instead.

Question 305

At Brookside Agency, a technician working in end-user troubleshooting identifies this issue: An employee can use Teams on office wireless but loses connectivity in the parking lot due to a cellular data toggle. The desired outcome is to distinguish cellular configuration from a working Wi-Fi connection. User data and business service continuity must be preserved. What should the technician recommend as the corrective approach?

  1. Choose less congested supported channels or move compatible clients to a cleaner 5 GHz band
  2. Enable permitted cellular data and confirm the correct subscriber plan
  3. Remove safe debris using manufacturer-recommended nonconductive methods or arrange service
  4. Correct the runaway synchronization or app update behavior while preserving necessary notifications

Explanation

Correct Answer

B:

Enable permitted cellular data and confirm the correct subscriber plan. It corrects the documented cause using the compatible technology and support constraints. The relevant observation is that an employee can use Teams on office wireless but loses connectivity in the parking lot due to a cellular data toggle. The support goal is to distinguish cellular configuration from a working Wi-Fi connection; this design action specifically addresses mobile data failure due to disabled cellular without confusing a different subsystem.

Incorrect Answers

A:

Choose less congested supported channels or move compatible clients to a cleaner 5 GHz band. This action is appropriate for intermittent wi-fi due to channel interference, normally when users near a lunchroom suffer slow 2.4 GHz Wi-Fi at peak periods while wired links stay normal. Here the observed facts require mobile data failure due to disabled cellular instead.

C:

Remove safe debris using manufacturer-recommended nonconductive methods or arrange service. This action is appropriate for mobile charging port debris, normally when a phone charges intermittently only when its USB-C plug is held at an angle. Here the observed facts require mobile data failure due to disabled cellular instead.

D:

Correct the runaway synchronization or app update behavior while preserving necessary notifications. This action is appropriate for background app mobile battery drain, normally when a business phone loses most of its battery overnight despite a healthy battery test. Here the observed facts require mobile data failure due to disabled cellular instead.

Question 306

During Juniper Tech's hardware and network incident triage, the technician encounters this condition: A new NVMe SSD is absent from firmware and the storage installer. The supporting record states that motherboard documentation shows one M.2 socket is SATA-only while the installed drive requires PCIe lanes. The desired outcome is to identify storage slot signaling incompatibility before declaring the SSD defective. User data and business service continuity must be preserved. Which controlled service test best evaluates the planned approach?

  1. Select the existing OS boot manager temporarily on a test PC
  2. Rehearse a RAID 1 rebuild with a disposable lab array and a spare disk
  3. Turn off Wi-Fi on a spare authorized test device and attempt a harmless network request
  4. Test the SSD in an approved NVMe-capable lab M.2 socket

Explanation

Correct Answer

D:

Test the SSD in an approved NVMe-capable lab M.2 socket. It tests the proposed solution safely on an approved representative system. The relevant observation is that motherboard documentation shows one M.2 socket is SATA-only while the installed drive requires PCIe lanes. The support goal is to identify storage slot signaling incompatibility before declaring the SSD defective; this pilot action specifically addresses nvme ssd not detected after installation without confusing a different subsystem.

Incorrect Answers

A:

Select the existing OS boot manager temporarily on a test PC. This action is appropriate for uefi boot order after a second drive, normally when a computer reports no bootable operating system after a new secondary drive was added. Here the observed facts require nvme ssd not detected after installation instead.

B:

Rehearse a RAID 1 rebuild with a disposable lab array and a spare disk. This action is appropriate for degraded raid after a failed member, normally when a mirrored NAS reports one disk failed while files remain available. Here the observed facts require nvme ssd not detected after installation instead.

C:

Turn off Wi-Fi on a spare authorized test device and attempt a harmless network request. This action is appropriate for mobile data failure due to disabled cellular, normally when a smartphone can browse over Wi-Fi but cannot connect to the internet when leaving the office. Here the observed facts require nvme ssd not detected after installation instead.

Question 307

On a service ticket for Stonebridge Research, the team observes: A seasonal ticket service needs temporary compute capacity only during sale windows. The desired outcome is to recognize elasticity as capacity adjustment to changing utilization. The customer requires a verified fix rather than a guess based on one symptom. How should the solution first be tested on an approved spare or pilot system?

  1. Test authorized isolation between two synthetic SaaS tenant accounts
  2. Run a safe synthetic load curve in an isolated test service to trigger scale out and back in
  3. Open a test virtual desktop session from a thin client over a controlled network
  4. Pilot a private-to-public integration in a controlled test network

Explanation

Correct Answer

B:

Run a safe synthetic load curve in an isolated test service to trigger scale out and back in. It tests the proposed solution safely on an approved representative system. The relevant observation is that a seasonal ticket service needs temporary compute capacity only during sale windows. The support goal is to recognize elasticity as capacity adjustment to changing utilization; this pilot action specifically addresses cloud elasticity versus fixed provisioning without confusing a different subsystem.

Incorrect Answers

A:

Test authorized isolation between two synthetic SaaS tenant accounts. This action is appropriate for multitenancy versus dedicated cloud resources, normally when an organization uses a SaaS platform shared with several customer organizations. Here the observed facts require cloud elasticity versus fixed provisioning instead.

C:

Open a test virtual desktop session from a thin client over a controlled network. This action is appropriate for vdi versus local desktop processing, normally when a company wants centrally managed user desktops accessed from inexpensive endpoints. Here the observed facts require cloud elasticity versus fixed provisioning instead.

D:

Pilot a private-to-public integration in a controlled test network. This action is appropriate for public versus private versus hybrid cloud, normally when an enterprise must keep one legacy regulatory workload in its own datacenter while scaling an unrelated web front end in a public provider. Here the observed facts require cloud elasticity versus fixed provisioning instead.

Question 308

At Pioneer Markets, a technician working in end-user troubleshooting identifies this issue: A new monitor's text appears soft because the operating system outputs 1366x768 to a 1920x1080 panel. The desired outcome is to correct resolution and scaling without treating blur as pixel hardware failure. The customer requires a verified fix rather than a guess based on one symptom. Which post-repair signal best detects regression or repeat exposure?

  1. Monitor driver mode changes and unexpected display scaling resets
  2. Monitor recurring connector issues and dock port strain
  3. Monitor brightness dropout and hinge-related display cable faults
  4. Monitor port configuration drift and unexpected subnet allocations

Explanation

Correct Answer

A:

Monitor driver mode changes and unexpected display scaling resets. It tracks recurrence of the specific failure mechanism over time. The relevant observation is that a new monitor's text appears soft because the operating system outputs 1366x768 to a 1920x1080 panel. The support goal is to correct resolution and scaling without treating blur as pixel hardware failure; this monitor action specifically addresses wrong screen resolution and scaling without confusing a different subsystem.

Incorrect Answers

B:

Monitor recurring connector issues and dock port strain. That action is appropriate for intermittent monitor image due to video cable, normally when a monitor intermittently goes black when its display cable is moved. Here the observed facts require wrong screen resolution and scaling instead.

C:

Monitor brightness dropout and hinge-related display cable faults. That action is appropriate for backlight failure on laptop lcd, normally when a laptop screen looks black but a flashlight reveals a faint intact desktop image. Here the observed facts require wrong screen resolution and scaling instead.

D:

Monitor port configuration drift and unexpected subnet allocations. This action is appropriate for vlan mismatch causing one desk to lose access, normally when a desk phone and PC stop reaching their correct services after a switch port change. Here the observed facts require wrong screen resolution and scaling instead.

Question 309

During Monarch Pharmacy's hardware and network incident triage, the technician encounters this condition: An office PC obtains a 169.254 address and cannot reach internet destinations. The supporting record states that its VLAN's DHCP helper address was removed during a switch configuration update. The desired outcome is to identify absent DHCP replies rather than blaming remote DNS first. Any configuration change must be reversible and validated on a controlled test device. Which diagnostic check best distinguishes the relevant fault?

  1. Inspect channel use, signal strength, client retries and non-Wi-Fi interference sources
  2. Check resolver settings, DNS request responses and direct-IP reachability
  3. Review DHCP Discover and Offer exchange, relay route and scope health
  4. Inspect link LEDs, cable jacket, RJ45 latch and switch port error counters

Explanation

Correct Answer

C:

Review DHCP Discover and Offer exchange, relay route and scope health. It checks the likely failure boundary before altering working parts or settings. The relevant observation is that its VLAN's DHCP helper address was removed during a switch configuration update. The support goal is to identify absent DHCP replies rather than blaming remote DNS first; this diagnose action specifically addresses dhcp failure and 169.254 apipa symptom without confusing a different subsystem.

Incorrect Answers

A:

Inspect channel use, signal strength, client retries and non-Wi-Fi interference sources. This action is appropriate for intermittent wi-fi due to channel interference, normally when users near a lunchroom suffer slow 2.4 GHz Wi-Fi at peak periods while wired links stay normal. Here the observed facts require dhcp failure and 169.254 apipa symptom instead.

B:

Check resolver settings, DNS request responses and direct-IP reachability. That action is appropriate for dns failure with working ip connectivity, normally when a workstation opens a service directly by numeric IP but says its hostname cannot be resolved. Here the observed facts require dhcp failure and 169.254 apipa symptom instead.

D:

Inspect link LEDs, cable jacket, RJ45 latch and switch port error counters. That action is appropriate for copper ethernet link flapping, normally when a workstation loses Ethernet connection whenever its patch lead is bent. Here the observed facts require dhcp failure and 169.254 apipa symptom instead.

Question 310

At Silverline Travel, a technician working in computer equipment refresh identifies this issue: A builder swaps in a low-wattage supply that lacks the required eight-pin GPU feed. The desired outcome is to select an adequately rated power supply with correct board and GPU connectors. A safe non-destructive test must be used before replacing additional parts. Which verification result supports the intended technical outcome?

  1. Verify stable component power without damaged devices or hot connectors
  2. Verify improved access latency and acceptable write endurance for the workload
  3. Verify the server remains online and generates the expected module failure alert
  4. Verify the machine remains stable under expected combined CPU and GPU draw

Explanation

Correct Answer

D:

Verify the machine remains stable under expected combined CPU and GPU draw. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that a builder swaps in a low-wattage supply that lacks the required eight-pin GPU feed. The support goal is to select an adequately rated power supply with correct board and GPU connectors; this validate action specifically addresses psu wattage and 20+4 atx connector without confusing a different subsystem.

Incorrect Answers

A:

Verify stable component power without damaged devices or hot connectors. This action is appropriate for modular psu cable safety, normally when a builder replaces a modular PSU but wants to reuse its old detachable power leads. Here the observed facts require psu wattage and 20+4 atx connector instead.

B:

Verify improved access latency and acceptable write endurance for the workload. This action is appropriate for ssd versus hdd latency and interface, normally when a mobile user needs low-latency storage and shock resistance but a procurement request specifies a 5400 RPM hard disk. Here the observed facts require psu wattage and 20+4 atx connector instead.

C:

Verify the server remains online and generates the expected module failure alert. This action is appropriate for redundant psu failover, normally when an office server needs to stay online when one power supply module fails. Here the observed facts require psu wattage and 20+4 atx connector instead.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests