cert
cert-1
cert-2

Pass CompTIA 220-1201 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
220-1201 Exam - Verified By Experts
220-1201 Premium Bundle
$29.98

220-1201 Premium Bundle

$79.99
$109.97
  • Premium File 527 Questions & Answers. Last update: Nov 15, 2026
  • Training Course 106 Video Lectures
  • Study Guide 2615 Pages
 
$109.97
$79.99
accept 102 downloads in last 7 days
block-screenshots
Purchase CompTIA 220-1201 Exam Training Products Individually
CompTIA 220-1201 Premium File
Premium File 527 Q&A
$76.99$69.99
CompTIA 220-1201 Video Training Course
Training Course 106 Lectures
$21.99 $19.99
CompTIA 220-1201 PDF Study Guide
Study Guide 2615 Pages
$21.99 $19.99
CompTIA 220-1201 Practice Test 100

Question 990

On a service ticket for Harborworks, the team observes: A file server has two equal 2 TB disks and needs redundancy against one disk failure. The supporting record states that a proposed RAID 0 stripe provides speed but no copy of data on a second drive. The desired outcome is to choose RAID 1 when simple mirroring is the requirement. The customer requires a verified fix rather than a guess based on one symptom. How should the solution first be tested on an approved spare or pilot system?

  1. Create a small lab array of two mirrored pairs striped together
  2. Simulate a single disk failure in an isolated RAID 1 test array
  3. Benchmark random reads on approved test HDD and SATA SSD devices
  4. Model two drive failures on a disposable RAID 6 lab array

Explanation

Correct Answer

B:

Simulate a single disk failure in an isolated RAID 1 test array. It tests the proposed solution safely on an approved representative system. The relevant observation is that a proposed RAID 0 stripe provides speed but no copy of data on a second drive. The support goal is to choose RAID 1 when simple mirroring is the requirement; this pilot action specifically addresses raid 1 mirror capacity and resilience without confusing a different subsystem.

Incorrect Answers

A:

Create a small lab array of two mirrored pairs striped together. That action is appropriate for raid 10 mirrored striped array, normally when a database server needs fast disk I/O and redundancy with four equal drives. Here the observed facts require raid 1 mirror capacity and resilience instead.

C:

Benchmark random reads on approved test HDD and SATA SSD devices. This action is appropriate for ssd versus hdd latency and interface, normally when a mobile user needs low-latency storage and shock resistance but a procurement request specifies a 5400 RPM hard disk. Here the observed facts require raid 1 mirror capacity and resilience instead.

D:

Model two drive failures on a disposable RAID 6 lab array. That action is appropriate for raid 5 versus raid 6 dual parity, normally when a four-disk production array must remain available during any two simultaneous drive failures. Here the observed facts require raid 1 mirror capacity and resilience instead.

Question 991

During Juniper Tech's workplace mobile support, the technician encounters this condition: A notebook loses Wi-Fi range after a screen repair while its wireless adapter remains detected. The desired outcome is to restore the wireless antenna path without replacing a healthy radio. Any configuration change must be reversible and validated on a controlled test device. What should the technician verify first to establish the problem?

  1. Inspect WLAN antenna snap connectors, cable routing and card detection against service documentation
  2. Confirm swelling, disconnect external power, and check the manufacturer's battery handling instructions
  3. Inspect eSIM profiles, carrier activation state, service plan and cellular data toggle
  4. Check backup success, recovery-key availability, drive connector and manufacturer form-factor compatibility

Explanation

Correct Answer

A:

Inspect WLAN antenna snap connectors, cable routing and card detection against service documentation. It checks the likely failure boundary before altering working parts or settings. The relevant observation is that a notebook loses Wi-Fi range after a screen repair while its wireless adapter remains detected. The support goal is to restore the wireless antenna path without replacing a healthy radio; this diagnose action specifically addresses laptop wi-fi antenna reconnection without confusing a different subsystem.

Incorrect Answers

B:

Confirm swelling, disconnect external power, and check the manufacturer's battery handling instructions. That action is appropriate for swollen laptop battery replacement, normally when a business laptop has a lifted trackpad and a visibly swollen internal lithium-ion battery. Here the observed facts require laptop wi-fi antenna reconnection instead.

C:

Inspect eSIM profiles, carrier activation state, service plan and cellular data toggle. This action is appropriate for mobile esim carrier activation, normally when a company phone has cellular signal bars but cannot attach to its assigned business data plan. Here the observed facts require laptop wi-fi antenna reconnection instead.

D:

Check backup success, recovery-key availability, drive connector and manufacturer form-factor compatibility. That action is appropriate for laptop ssd replacement and encryption, normally when a laptop SSD is failing SMART health checks and holds company data protected with full-disk encryption. Here the observed facts require laptop wi-fi antenna reconnection instead.

Question 992

During Keystone Health's branch networking support, the technician encounters this condition: A mail migration fails because administrators edit an SPF string instead of the MX record. The desired outcome is to distinguish mail routing records from sender authorization policies. Only approved service procedures and compatible replacement components may be used. What observation would verify successful service restoration?

  1. Confirm the same address returns on renewal and is not leased to another client
  2. Verify guest traffic cannot reach payroll while VPN users reach their approved internal resources
  3. Verify improved wireless contention and connection reliability without assuming the wired tap measured radio noise
  4. Verify incoming mail resolves to the right mail exchanger and SPF evaluates approved senders

Explanation

Correct Answer

D:

Verify incoming mail resolves to the right mail exchanger and SPF evaluates approved senders. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that a mail migration fails because administrators edit an SPF string instead of the MX record. The support goal is to distinguish mail routing records from sender authorization policies; this validate action specifically addresses mx and spf dns records distinct purposes without confusing a different subsystem.

Incorrect Answers

A:

Confirm the same address returns on renewal and is not leased to another client. That action is appropriate for dhcp reservation versus exclusion, normally when a networked printer must keep the same IPv4 address while the rest of the office remains DHCP-managed. Here the observed facts require mx and spf dns records distinct purposes instead.

B:

Verify guest traffic cannot reach payroll while VPN users reach their approved internal resources. That action is appropriate for vlan segmentation versus vpn encrypted tunneling, normally when a small office needs guest Wi-Fi isolated from payroll devices but also needs secure remote employee access. Here the observed facts require mx and spf dns records distinct purposes instead.

C:

Verify improved wireless contention and connection reliability without assuming the wired tap measured radio noise. This action is appropriate for wi-fi analyzer versus network tap, normally when staff complain about busy wireless channels in a meeting room. Here the observed facts require mx and spf dns records distinct purposes instead.

Question 993

During Granite Capital's IT virtualization planning, the technician encounters this condition: A company wants centrally managed user desktops accessed from inexpensive endpoints. The supporting record states that user sessions must run inside a hosted datacenter platform and persist per supported policy. The desired outcome is to choose Virtual Desktop Infrastructure rather than local OS installations. User data and business service continuity must be preserved. Which safe pilot action gives the most relevant evidence?

  1. Take a test snapshot then restore it while testing separate backup recovery
  2. Boot a disposable guest after enabling the feature on a lab system
  3. Open a test virtual desktop session from a thin client over a controlled network
  4. Start a harmless container on a lab host and inspect the shared kernel version

Explanation

Correct Answer

C:

Open a test virtual desktop session from a thin client over a controlled network. It tests the proposed solution safely on an approved representative system. The relevant observation is that user sessions must run inside a hosted datacenter platform and persist per supported policy. The support goal is to choose Virtual Desktop Infrastructure rather than local OS installations; this pilot action specifically addresses vdi versus local desktop processing without confusing a different subsystem.

Incorrect Answers

A:

Take a test snapshot then restore it while testing separate backup recovery. This action is appropriate for vm snapshot versus independent backup, normally when a developer calls a local VM snapshot a complete disaster recovery backup. Here the observed facts require vdi versus local desktop processing instead.

B:

Boot a disposable guest after enabling the feature on a lab system. That action is appropriate for virtualization cpu extensions, normally when a new virtual machine cannot start a 64-bit guest even though the host processor supports virtualization. Here the observed facts require vdi versus local desktop processing instead.

D:

Start a harmless container on a lab host and inspect the shared kernel version. That action is appropriate for container isolation versus full virtual machine, normally when a team needs to package one web service and its dependencies but not another complete guest kernel. Here the observed facts require vdi versus local desktop processing instead.

Question 994

During Monarch Pharmacy's computer equipment refresh, the technician encounters this condition: A laptop replacement M.2 disk fits its bay but is invisible because firmware supports only SATA M.2. The desired outcome is to match storage interface protocol to motherboard slot capabilities. Any configuration change must be reversible and validated on a controlled test device. Which diagnostic check best distinguishes the relevant fault?

  1. Read motherboard M.2 keying and SATA or PCIe lane support alongside drive protocol
  2. Check touch controller reporting and the glass digitizer surface instead of replacing the inverter
  3. Check fiber type, distance budget, wavelength and transceiver compatibility
  4. Inspect each RJ45 conductor color order and wiremap tester results

Explanation

Correct Answer

A:

Read motherboard M.2 keying and SATA or PCIe lane support alongside drive protocol. It checks the likely failure boundary before altering working parts or settings. The relevant observation is that a laptop replacement M.2 disk fits its bay but is invisible because firmware supports only SATA M.2. The support goal is to match storage interface protocol to motherboard slot capabilities; this diagnose action specifically addresses nvme pcie versus sata storage interface without confusing a different subsystem.

Incorrect Answers

B:

Check touch controller reporting and the glass digitizer surface instead of replacing the inverter. This action is appropriate for digitizer input versus backlight inverter, normally when a convertible LCD image is visible but finger touches no longer register at a specific region. Here the observed facts require nvme pcie versus sata storage interface instead.

C:

Check fiber type, distance budget, wavelength and transceiver compatibility. That action is appropriate for single-mode versus multimode fiber, normally when a campus backbone spans several kilometers between buildings and requires high throughput. Here the observed facts require nvme pcie versus sata storage interface instead.

D:

Inspect each RJ45 conductor color order and wiremap tester results. That action is appropriate for t568a versus t568b rj45 terminations, normally when a newly crimped eight-wire Ethernet cable fails a wiremap test because one end follows T568A and the other T568B. Here the observed facts require nvme pcie versus sata storage interface instead.

Question 995

On a service ticket for Silverline Travel, the team observes: A tower PC has no LEDs, fans, or POST activity after the user changed power outlets. The supporting record states that the AC cable and switched outlet are unverified and there is no sign the PSU receives input. The desired outcome is to isolate basic external power before replacing the motherboard. User data and business service continuity must be preserved. Which verification result supports the intended technical outcome?

  1. Verify POST and extended memory tests pass with all intended modules installed
  2. Verify stable boot and normal shutdown with the safe power connection
  3. Verify stable operation without power-related resets at the specified load
  4. Verify POST and video return without the suspect expansion card

Explanation

Correct Answer

B:

Verify stable boot and normal shutdown with the safe power connection. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that the AC cable and switched outlet are unverified and there is no sign the PSU receives input. The support goal is to isolate basic external power before replacing the motherboard; this validate action specifically addresses completely dead desktop power path without confusing a different subsystem.

Incorrect Answers

A:

Verify POST and extended memory tests pass with all intended modules installed. That action is appropriate for desktop memory fault preventing post, normally when a desktop powers on but gives a repeating memory-related beep pattern and no display. Here the observed facts require completely dead desktop power path instead.

C:

Verify stable operation without power-related resets at the specified load. This action is appropriate for psu instability under peak component load, normally when a machine passes idle checks but reboots when the GPU and CPU draw peak power together. Here the observed facts require completely dead desktop power path instead.

D:

Verify POST and video return without the suspect expansion card. That action is appropriate for post beep code interpretation and expansion-card isolation, normally when a newly upgraded desktop beeps at startup and shows no BIOS screen. Here the observed facts require completely dead desktop power path instead.

Question 996

A support request at Maplebank Ltd presents this problem: A consultant requests company email on a personal tablet with no whole-device management rights. The desired outcome is to apply supported corporate application controls with appropriate privacy scope. Any configuration change must be reversible and validated on a controlled test device. Which safe pilot action gives the most relevant evidence?

  1. Activate the eSIM on a spare enrolled phone using an approved carrier test profile
  2. Create one harmless test appointment and synchronize through the chosen enterprise account
  3. Connect a test laptop, both monitors and the approved dock power supply in a service area
  4. Pilot managed work apps with a consented BYOD phone and an unprotected personal app

Explanation

Correct Answer

D:

Pilot managed work apps with a consented BYOD phone and an unprotected personal app. It tests the proposed solution safely on an approved representative system. The relevant observation is that a consultant requests company email on a personal tablet with no whole-device management rights. The support goal is to apply supported corporate application controls with appropriate privacy scope; this pilot action specifically addresses byod mobile application management without confusing a different subsystem.

Incorrect Answers

A:

Activate the eSIM on a spare enrolled phone using an approved carrier test profile. That action is appropriate for mobile esim carrier activation, normally when a company phone has cellular signal bars but cannot attach to its assigned business data plan. Here the observed facts require byod mobile application management instead.

B:

Create one harmless test appointment and synchronize through the chosen enterprise account. That action is appropriate for mobile calendar and contact synchronization, normally when a user's phone receives mail but calendar edits never appear on the company laptop. Here the observed facts require byod mobile application management instead.

C:

Connect a test laptop, both monitors and the approved dock power supply in a service area. This action is appropriate for docking station display and power capability, normally when a small-business employee connects two monitors and power to a laptop through a new USB-C dock. Here the observed facts require byod mobile application management instead.

Question 997

On a service ticket for Fountain Transport, the team observes: A campus backbone spans several kilometers between buildings and requires high throughput. The supporting record states that the planned multimode optic supports too short a reach for the installed path while suitable single-mode optics exist. The desired outcome is to choose optical media and transceivers matched to distance and wavelength. Only approved service procedures and compatible replacement components may be used. What should support monitor to catch a recurrence of the same failure?

  1. Monitor renegotiation to fallback modes after dock or firmware changes
  2. Monitor optical attenuation and connector contamination
  3. Monitor inventory bins for mixed laptop and desktop memory modules
  4. Monitor new drive purchases for overlooked slot protocol differences

Explanation

Correct Answer

B:

Monitor optical attenuation and connector contamination. It tracks recurrence of the specific failure mechanism over time. The relevant observation is that the planned multimode optic supports too short a reach for the installed path while suitable single-mode optics exist. The support goal is to choose optical media and transceivers matched to distance and wavelength; this monitor action specifically addresses single-mode versus multimode fiber without confusing a different subsystem.

Incorrect Answers

A:

Monitor renegotiation to fallback modes after dock or firmware changes. That action is appropriate for usb-c versus thunderbolt port capability, normally when an external high-bandwidth storage enclosure only negotiates low speed on a laptop USB-C connector. Here the observed facts require single-mode versus multimode fiber instead.

C:

Monitor inventory bins for mixed laptop and desktop memory modules. This action is appropriate for sodimm versus dimm form factor, normally when a desktop repair requires replacement memory but the spare part comes from a notebook. Here the observed facts require single-mode versus multimode fiber instead.

D:

Monitor new drive purchases for overlooked slot protocol differences. That action is appropriate for nvme pcie versus sata storage interface, normally when a technician orders an M.2 SSD for a motherboard slot that supports only SATA signaling. Here the observed facts require single-mode versus multimode fiber instead.

Question 998

A support request at Northland Labs presents this problem: A firewall allows remote desktop to a Windows server but staff cannot browse its shared project folder. The desired outcome is to identify the protocol and port needed for Windows file share access. Only approved service procedures and compatible replacement components may be used. Which configuration or repair action best addresses the stated requirement?

  1. Restore DHCP server or relay reachability rather than assigning random static client addresses
  2. Use a Wi-Fi analyzer to select a cleaner channel and appropriate channel width
  3. Permit the authorized DNS transport paths including TCP 53 without opening unrelated services
  4. Allow approved SMB 445 between specified clients and the file server without opening remote desktop

Explanation

Correct Answer

D:

Allow approved SMB 445 between specified clients and the file server without opening remote desktop. It corrects the documented cause using the compatible technology and support constraints. The relevant observation is that a firewall allows remote desktop to a Windows server but staff cannot browse its shared project folder. The support goal is to identify the protocol and port needed for Windows file share access; this design action specifically addresses smb file sharing port versus rdp without confusing a different subsystem.

Incorrect Answers

A:

Restore DHCP server or relay reachability rather than assigning random static client addresses. That action is appropriate for dhcp client and server port roles, normally when a new PC never receives an IPv4 lease on its office VLAN. Here the observed facts require smb file sharing port versus rdp instead.

B:

Use a Wi-Fi analyzer to select a cleaner channel and appropriate channel width. This action is appropriate for wi-fi analyzer versus network tap, normally when staff complain about busy wireless channels in a meeting room. Here the observed facts require smb file sharing port versus rdp instead.

C:

Permit the authorized DNS transport paths including TCP 53 without opening unrelated services. That action is appropriate for dns service transport and port 53, normally when a branch resolver answers ordinary UDP name queries but large signed responses fail. Here the observed facts require smb file sharing port versus rdp instead.

Question 999

On a service ticket for Vertex Media, the team observes: An IT manager insists a parity array survive two failed disks during a long maintenance window. The desired outcome is to select a RAID level providing protection against two disk failures. Only approved service procedures and compatible replacement components may be used. What should be tracked after the fix to maintain service reliability?

  1. Monitor patrol reads, failed drives and rebuild exposure
  2. Monitor renegotiation to fallback modes after dock or firmware changes
  3. Monitor remaining SSD health and firmware updates
  4. Monitor mirror health and successful independent backups

Explanation

Correct Answer

A:

Monitor patrol reads, failed drives and rebuild exposure. It tracks recurrence of the specific failure mechanism over time. The relevant observation is that an IT manager insists a parity array survive two failed disks during a long maintenance window. The support goal is to select a RAID level providing protection against two disk failures; this monitor action specifically addresses raid 5 versus raid 6 dual parity without confusing a different subsystem.

Incorrect Answers

B:

Monitor renegotiation to fallback modes after dock or firmware changes. This action is appropriate for usb-c versus thunderbolt port capability, normally when an external high-bandwidth storage enclosure only negotiates low speed on a laptop USB-C connector. Here the observed facts require raid 5 versus raid 6 dual parity instead.

C:

Monitor remaining SSD health and firmware updates. That action is appropriate for ssd versus hdd latency and interface, normally when a mobile user needs low-latency storage and shock resistance but a procurement request specifies a 5400 RPM hard disk. Here the observed facts require raid 5 versus raid 6 dual parity instead.

D:

Monitor mirror health and successful independent backups. That action is appropriate for raid 1 mirror capacity and resilience, normally when a file server has two equal 2 TB disks and needs redundancy against one disk failure. Here the observed facts require raid 5 versus raid 6 dual parity instead.

Question 1000

At Orchard Services, a technician working in laptop and mobile device repair identifies this issue: A corporate laptop's camera indicator comes on during meetings even when the user thinks video is disabled. The supporting record states that the hardware privacy shutter and camera disable switch are independently controllable from the conferencing app. The desired outcome is to distinguish physical camera privacy control from software meeting settings. Any configuration change must be reversible and validated on a controlled test device. What observation would verify successful service restoration?

  1. Verify the new battery sits flat, charges normally, and the enclosure closes without pressure
  2. Confirm the camera shows no image behind the closed shutter while audio remains unaffected
  3. Verify BIOS reports the expected memory and extended diagnostics pass without errors
  4. Compare Wi-Fi received signal strength and roaming stability before and after reconnection

Explanation

Correct Answer

B:

Confirm the camera shows no image behind the closed shutter while audio remains unaffected. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that the hardware privacy shutter and camera disable switch are independently controllable from the conferencing app. The support goal is to distinguish physical camera privacy control from software meeting settings; this validate action specifically addresses physical webcam privacy hardware without confusing a different subsystem.

Incorrect Answers

A:

Verify the new battery sits flat, charges normally, and the enclosure closes without pressure. This action is appropriate for swollen laptop battery replacement, normally when a business laptop has a lifted trackpad and a visibly swollen internal lithium-ion battery. Here the observed facts require physical webcam privacy hardware instead.

C:

Verify BIOS reports the expected memory and extended diagnostics pass without errors. That action is appropriate for laptop sodimm compatibility, normally when a field technician wants to add RAM to a serviceable laptop that currently uses DDR4 SODIMMs. Here the observed facts require physical webcam privacy hardware instead.

D:

Compare Wi-Fi received signal strength and roaming stability before and after reconnection. That action is appropriate for laptop wi-fi antenna reconnection, normally when after a laptop display assembly replacement, Bluetooth works but Wi-Fi signal is very weak. Here the observed facts require physical webcam privacy hardware instead.