cert
cert-1
cert-2

Pass Cisco 300-745 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
300-745 Exam - Verified By Experts
300-745 Premium File

300-745 Premium File

$69.99
$76.99
  • Premium File 77 Questions & Answers. Last Update: Nov 21, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Cisco 300-745 Practice Test 51

Question 500

A regional hospital routes all traffic through one security gateway with no redundant unit despite a business continuity requirement for uninterrupted clinical records. Following the authorized correction, which observed result would most directly verify that the ORIGINAL problem has been solved?

  1. Clinical sessions survive an approved gateway failover within the documented recovery objective.
  2. A clean independent restore point remains available after a simulated delayed compromise.
  3. A controlled traffic stress test preserves portal availability through the designed mitigation path.
  4. The report job reaches only its needed database endpoint and other server access is denied.

Explanation

Correct Answer

A:

This result directly proves the approved repair addressed the case: Clinical sessions survive an approved gateway failover within the documented recovery objective. The planned intervention was Design a tested resilient gateway pair with synchronized state and independently supported failure paths. For independent corroboration, also perform Compare failover routing behavior in a maintenance simulation with the proposed redundant topology. A successful command alone would not establish this end-user outcome.

Incorrect Answers

B:

The proposed measure is relevant to cloud backup retention too short for ransomware detection window, not the reported fault: A regional hospital routes all traffic through one security gateway with no redundant unit despite a business continuity requirement for uninterrupted clinical records. To differentiate the failure, inspect the current failure domain and the availability requirements for clinical applications. The matching corrective response is to design a tested resilient gateway pair with synchronized state and independently supported failure paths.

C:

The proposed measure is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A regional hospital routes all traffic through one security gateway with no redundant unit despite a business continuity requirement for uninterrupted clinical records. To differentiate the failure, inspect the current failure domain and the availability requirements for clinical applications. The matching corrective response is to design a tested resilient gateway pair with synchronized state and independently supported failure paths.

D:

The proposed measure is relevant to legacy application requires broad admin firewall exception, not the reported fault: A regional hospital routes all traffic through one security gateway with no redundant unit despite a business continuity requirement for uninterrupted clinical records. To differentiate the failure, inspect the current failure domain and the availability requirements for clinical applications. The matching corrective response is to design a tested resilient gateway pair with synchronized state and independently supported failure paths.

Question 501

A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. A security architecture engineer is investigating this fictional security design case. Which correction most directly addresses the observed fault without changing unrelated security services?

  1. Use staged configuration commits with reachability validation and automatic rollback when the management path fails.
  2. Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.
  3. Require explicit exception ownership time-bound expiry and automated review for temporary security controls.
  4. Design independent redundant key-management availability and securely backed-up recovery materials outside the same failure domain.

Explanation

Correct Answer

B:

The relevant facts are: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. The supported corrective response is Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile. Confirm the suspected cause using Compare data classifications and credible attack paths for both device categories. Following the change, success means High-impact assets receive stronger proportionate controls and documented residual risk decisions.

Incorrect Answers

A:

The alternative is relevant to remote branch security change lacks rollback connectivity, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

C:

The alternative is relevant to unowned exception leaves exposed development environment, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

D:

The alternative is relevant to key-management system located in same failure zone, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

Question 502

A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. Before making a change, the engineer wants two independent checks that directly test the suspected fault. Which TWO observations should be collected? (Select TWO.)

  1. Compare data classifications and credible attack paths for both device categories.
  2. Inspect key manager dependencies and the actual location of encrypted key backups.
  3. Inspect the firewall exception's business owner and expiry metadata.
  4. Inspect historical and anticipated traffic volume relative to available circuit and scrubbing capacity.
  5. Review the documented risk assessment and residual-risk acceptance authorities.

Explanation

Correct Answers

A:

This check directly targets the reported failure: Compare data classifications and credible attack paths for both device categories. It independently corroborates Review the documented risk assessment and residual-risk acceptance authorities. Together they provide evidence before implementing Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile. A successful resolution is High-impact assets receive stronger proportionate controls and documented residual risk decisions.

E:

This check directly targets the reported failure: Review the documented risk assessment and residual-risk acceptance authorities. It independently corroborates Compare data classifications and credible attack paths for both device categories. Together they provide evidence before implementing Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile. A successful resolution is High-impact assets receive stronger proportionate controls and documented residual risk decisions.

Incorrect Answers

B:

The suggested fix is relevant to key-management system located in same failure zone, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

C:

The suggested fix is relevant to unowned exception leaves exposed development environment, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

D:

The suggested fix is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

Question 503

A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. If this condition is left unresolved, which operational or security consequence follows most directly from the available facts?

  1. Expired exceptions can permanently expose services beyond their justified business need.
  2. A mistaken remote policy can lock operators out and delay incident recovery.
  3. Loss of the shared failure zone can render otherwise intact encrypted backups unusable.
  4. Uniform controls can overprotect low-risk assets while leaving high-impact data inadequately safeguarded.

Explanation

Correct Answer

D:

The case describes A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. The specific consequence supported by those conditions is Uniform controls can overprotect low-risk assets while leaving high-impact data inadequately safeguarded. This is a plausible unresolved risk, not an assertion that damage has already occurred. The corrective control remains Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

Incorrect Answers

A:

That option is relevant to unowned exception leaves exposed development environment, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

B:

That option is relevant to remote branch security change lacks rollback connectivity, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

C:

That option is relevant to key-management system located in same failure zone, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

Question 504

A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. A change reviewer requires BOTH the corrective step and a matching risk-control safeguard. Which TWO actions form the most appropriate pair? (Select TWO.)

  1. Require risk owner approval and regular review of material changes in exposure.
  2. Require explicit exception ownership time-bound expiry and automated review for temporary security controls.
  3. Separate backup administration and immutable storage identities from routine production security domains.
  4. Arrange upstream volumetric DDoS mitigation with measured diversion and application-layer protections.
  5. Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

Explanation

Correct Answers

A:

This is the appropriate change-control precaution: Require risk owner approval and regular review of material changes in exposure. That guard reduces the case-specific exposure Uniform controls can overprotect low-risk assets while leaving high-impact data inadequately safeguarded. The paired technical correction is Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile. Completion is judged using High-impact assets receive stronger proportionate controls and documented residual risk decisions.

E:

This is the targeted repair: Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile. It must be paired with a separately selected risk-control action: Require risk owner approval and regular review of material changes in exposure. Together these address the concern Uniform controls can overprotect low-risk assets while leaving high-impact data inadequately safeguarded. Verify the outcome using High-impact assets receive stronger proportionate controls and documented residual risk decisions.

Incorrect Answers

B:

The competing intervention is relevant to unowned exception leaves exposed development environment, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

C:

The competing intervention is relevant to backup network shares same trust as compromised production, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

D:

The competing intervention is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

Question 505

A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. Following the authorized correction, which observed result would most directly verify that the ORIGINAL problem has been solved?

  1. The policy applies only when health tests pass and safely reverts when reachability fails.
  2. The database can recover keys under the approved disaster scenario without exposing secret material.
  3. The temporary test rule expires automatically while authorized permanent services remain accessible.
  4. High-impact assets receive stronger proportionate controls and documented residual risk decisions.

Explanation

Correct Answer

D:

This result directly proves the approved repair addressed the case: High-impact assets receive stronger proportionate controls and documented residual risk decisions. The planned intervention was Set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile. For independent corroboration, also perform Review the documented risk assessment and residual-risk acceptance authorities. A successful command alone would not establish this end-user outcome.

Incorrect Answers

A:

The proposed measure is relevant to remote branch security change lacks rollback connectivity, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

B:

The proposed measure is relevant to key-management system located in same failure zone, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

C:

The proposed measure is relevant to unowned exception leaves exposed development environment, not the reported fault: A company applies the same malware policy to a public kiosk and a machine storing highly confidential merger documents, disregarding the different impacts. To differentiate the failure, compare data classifications and credible attack paths for both device categories. The matching corrective response is to set risk treatments using asset criticality threat likelihood exposure and business impact rather than a single uniform control profile.

Question 506

A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. A security architecture engineer is investigating this fictional security design case. Which correction most directly addresses the observed fault without changing unrelated security services?

  1. Separate backup administration and immutable storage identities from routine production security domains.
  2. Add protected immutable backup generations and retention designed around realistic detection and recovery objectives.
  3. Design a tested resilient gateway pair with synchronized state and independently supported failure paths.
  4. Arrange upstream volumetric DDoS mitigation with measured diversion and application-layer protections.

Explanation

Correct Answer

B:

The relevant facts are: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. The supported corrective response is Add protected immutable backup generations and retention designed around realistic detection and recovery objectives. Confirm the suspected cause using Inspect backup history and immutability settings relative to documented recovery requirements. Following the change, success means A clean independent restore point remains available after a simulated delayed compromise.

Incorrect Answers

A:

The alternative is relevant to backup network shares same trust as compromised production, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

C:

The alternative is relevant to single edge firewall is availability bottleneck, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

D:

The alternative is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

Question 507

A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. Before making a change, the engineer wants two independent checks that directly test the suspected fault. Which TWO observations should be collected? (Select TWO.)

  1. Inspect historical and anticipated traffic volume relative to available circuit and scrubbing capacity.
  2. Inspect the change design for tested alternative management and checkpoint mechanisms.
  3. Simulate recovery from an older clean restore point in an isolated environment.
  4. Compare access roles for domain admins and backup deletion operations.
  5. Inspect backup history and immutability settings relative to documented recovery requirements.

Explanation

Correct Answers

C:

This check directly targets the reported failure: Simulate recovery from an older clean restore point in an isolated environment. It independently corroborates Inspect backup history and immutability settings relative to documented recovery requirements. Together they provide evidence before implementing Add protected immutable backup generations and retention designed around realistic detection and recovery objectives. A successful resolution is A clean independent restore point remains available after a simulated delayed compromise.

E:

This check directly targets the reported failure: Inspect backup history and immutability settings relative to documented recovery requirements. It independently corroborates Simulate recovery from an older clean restore point in an isolated environment. Together they provide evidence before implementing Add protected immutable backup generations and retention designed around realistic detection and recovery objectives. A successful resolution is A clean independent restore point remains available after a simulated delayed compromise.

Incorrect Answers

A:

The suggested fix is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

B:

The suggested fix is relevant to remote branch security change lacks rollback connectivity, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

D:

The suggested fix is relevant to backup network shares same trust as compromised production, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

Question 508

A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. If this condition is left unresolved, which operational or security consequence follows most directly from the available facts?

  1. A shared trust boundary can let one production compromise destroy both data and recovery capability.
  2. A single inspection appliance failure can isolate critical services even without an attack.
  3. An on-premises firewall cannot absorb attack volume that saturates its upstream link.
  4. Short mutable retention can leave no viable known-good recovery after delayed incident discovery.

Explanation

Correct Answer

D:

The case describes A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. The specific consequence supported by those conditions is Short mutable retention can leave no viable known-good recovery after delayed incident discovery. This is a plausible unresolved risk, not an assertion that damage has already occurred. The corrective control remains Add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

Incorrect Answers

A:

That option is relevant to backup network shares same trust as compromised production, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

B:

That option is relevant to single edge firewall is availability bottleneck, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

C:

That option is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

Question 509

A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. A change reviewer requires BOTH the corrective step and a matching risk-control safeguard. Which TWO actions form the most appropriate pair? (Select TWO.)

  1. Protect recovery credentials separately and verify restores before adjusting production retention.
  2. Design independent redundant key-management availability and securely backed-up recovery materials outside the same failure domain.
  3. Use staged configuration commits with reachability validation and automatic rollback when the management path fails.
  4. Arrange upstream volumetric DDoS mitigation with measured diversion and application-layer protections.
  5. Add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

Explanation

Correct Answers

A:

This is the appropriate change-control precaution: Protect recovery credentials separately and verify restores before adjusting production retention. That guard reduces the case-specific exposure Short mutable retention can leave no viable known-good recovery after delayed incident discovery. The paired technical correction is Add protected immutable backup generations and retention designed around realistic detection and recovery objectives. Completion is judged using A clean independent restore point remains available after a simulated delayed compromise.

E:

This is the targeted repair: Add protected immutable backup generations and retention designed around realistic detection and recovery objectives. It must be paired with a separately selected risk-control action: Protect recovery credentials separately and verify restores before adjusting production retention. Together these address the concern Short mutable retention can leave no viable known-good recovery after delayed incident discovery. Verify the outcome using A clean independent restore point remains available after a simulated delayed compromise.

Incorrect Answers

B:

The competing intervention is relevant to key-management system located in same failure zone, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

C:

The competing intervention is relevant to remote branch security change lacks rollback connectivity, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

D:

The competing intervention is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

Question 510

A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. Following the authorized correction, which observed result would most directly verify that the ORIGINAL problem has been solved?

  1. A clean independent restore point remains available after a simulated delayed compromise.
  2. A controlled traffic stress test preserves portal availability through the designed mitigation path.
  3. A production-domain test account cannot delete protected backups and approved restoration succeeds.
  4. Clinical sessions survive an approved gateway failover within the documented recovery objective.

Explanation

Correct Answer

A:

This result directly proves the approved repair addressed the case: A clean independent restore point remains available after a simulated delayed compromise. The planned intervention was Add protected immutable backup generations and retention designed around realistic detection and recovery objectives. For independent corroboration, also perform Simulate recovery from an older clean restore point in an isolated environment. A successful command alone would not establish this end-user outcome.

Incorrect Answers

B:

The proposed measure is relevant to ddos mitigation capacity undersized for public service, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

C:

The proposed measure is relevant to backup network shares same trust as compromised production, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

D:

The proposed measure is relevant to single edge firewall is availability bottleneck, not the reported fault: A business retains only one day of mutable backups, yet ransomware events commonly remain undetected long enough for that copy to be altered. To differentiate the failure, inspect backup history and immutability settings relative to documented recovery requirements. The matching corrective response is to add protected immutable backup generations and retention designed around realistic detection and recovery objectives.

Designing Cisco Security Infrastructure (300-745) Practice Tests