cert
cert-1
cert-2

Pass Cisco 300-745 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
300-745 Exam - Verified By Experts
300-745 Premium File

300-745 Premium File

$69.99
$76.99
  • Premium File 77 Questions & Answers. Last Update: Nov 21, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Cisco 300-745 Practice Test 23

Question 220

A remote employee laptop leaves corporate VPN and connects to public Wi-Fi where the enterprise perimeter firewall has no visibility of inbound local network probes. Following the authorized correction, which observed result would most directly verify that the ORIGINAL problem has been solved?

  1. Approved apps continue and identified disallowed applications are denied under policy.
  2. Unapproved east-west lateral traffic is denied at workload boundaries without breaking necessary services.
  3. Unapproved container process egress is detected and blocked without interrupting authorized pod communications.
  4. Public-network probes cannot reach restricted laptop services while permitted outbound work continues.

Explanation

Correct Answer

D:

This result directly proves the approved repair addressed the case: Public-network probes cannot reach restricted laptop services while permitted outbound work continues. The planned intervention was Enforce centrally managed host-based firewall profiles that default deny unneeded inbound services on untrusted networks. For independent corroboration, also perform Test an authorized benign inbound connection probe to exposed laptop services on public Wi-Fi. A successful command alone would not establish this end-user outcome.

Incorrect Answers

A:

The proposed measure is relevant to ngfw application identification absent for unknown tls flow, not the reported fault: A remote employee laptop leaves corporate VPN and connects to public Wi-Fi where the enterprise perimeter firewall has no visibility of inbound local network probes. To differentiate the failure, compare host firewall profiles active on corporate versus public networks. The matching corrective response is to enforce centrally managed host-based firewall profiles that default deny unneeded inbound services on untrusted networks.

B:

The proposed measure is relevant to east-west workload traffic bypasses perimeter ngfw, not the reported fault: A remote employee laptop leaves corporate VPN and connects to public Wi-Fi where the enterprise perimeter firewall has no visibility of inbound local network probes. To differentiate the failure, compare host firewall profiles active on corporate versus public networks. The matching corrective response is to enforce centrally managed host-based firewall profiles that default deny unneeded inbound services on untrusted networks.

C:

The proposed measure is relevant to ebpf runtime policy for ephemeral container workloads, not the reported fault: A remote employee laptop leaves corporate VPN and connects to public Wi-Fi where the enterprise perimeter firewall has no visibility of inbound local network probes. To differentiate the failure, compare host firewall profiles active on corporate versus public networks. The matching corrective response is to enforce centrally managed host-based firewall profiles that default deny unneeded inbound services on untrusted networks.

Question 221

Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. A security architecture engineer is investigating this fictional security design case. Which correction most directly addresses the observed fault without changing unrelated security services?

  1. Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.
  2. Enforce centrally managed host-based firewall profiles that default deny unneeded inbound services on untrusted networks.
  3. Deploy a supported inline IPS or enforcement control at the correct traffic choke point with tuned prevention signatures.
  4. Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

Explanation

Correct Answer

D:

The relevant facts are: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. The supported corrective response is Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context. Confirm the suspected cause using Inspect workload-to-process flow attribution for a short-lived test container. Following the change, success means Unapproved container process egress is detected and blocked without interrupting authorized pod communications.

Incorrect Answers

A:

The alternative is relevant to traditional acl needed instead of deep packet inspection, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

B:

The alternative is relevant to host firewall required for roaming laptop on public wi-fi, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

C:

The alternative is relevant to ids detects intrusion but cannot stop repeated attack, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

Question 222

Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. Before making a change, the engineer wants two independent checks that directly test the suspected fault. Which TWO observations should be collected? (Select TWO.)

  1. Inspect workload-to-process flow attribution for a short-lived test container.
  2. Compare pod identity and allowed egress destinations with actual node-level socket events.
  3. Compare observed encrypted flow metadata with identified application categories and policy matches.
  4. Compare host firewall profiles active on corporate versus public networks.
  5. Inspect whether the sensor receives mirrored packets or sits inline in the forwarded path.

Explanation

Correct Answers

A:

This check directly targets the reported failure: Inspect workload-to-process flow attribution for a short-lived test container. It independently corroborates Compare pod identity and allowed egress destinations with actual node-level socket events. Together they provide evidence before implementing Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context. A successful resolution is Unapproved container process egress is detected and blocked without interrupting authorized pod communications.

B:

This check directly targets the reported failure: Compare pod identity and allowed egress destinations with actual node-level socket events. It independently corroborates Inspect workload-to-process flow attribution for a short-lived test container. Together they provide evidence before implementing Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context. A successful resolution is Unapproved container process egress is detected and blocked without interrupting authorized pod communications.

Incorrect Answers

C:

The suggested fix is relevant to ngfw application identification absent for unknown tls flow, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

D:

The suggested fix is relevant to host firewall required for roaming laptop on public wi-fi, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

E:

The suggested fix is relevant to ids detects intrusion but cannot stop repeated attack, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

Question 223

Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. If this condition is left unresolved, which operational or security consequence follows most directly from the available facts?

  1. Overengineering inspection on unsupported hardware can cause outages without adding meaningful risk reduction.
  2. Out-of-band detection may report a threat while malicious packets still reach the target.
  3. Perimeter-only controls leave roaming endpoints exposed to direct local network threats.
  4. IP-only controls can lose process context when ephemeral workloads share addresses or nodes.

Explanation

Correct Answer

D:

The case describes Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. The specific consequence supported by those conditions is IP-only controls can lose process context when ephemeral workloads share addresses or nodes. This is a plausible unresolved risk, not an assertion that damage has already occurred. The corrective control remains Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

Incorrect Answers

A:

That option is relevant to traditional acl needed instead of deep packet inspection, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

B:

That option is relevant to ids detects intrusion but cannot stop repeated attack, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

C:

That option is relevant to host firewall required for roaming laptop on public wi-fi, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

Question 224

Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. A change reviewer requires BOTH the corrective step and a matching risk-control safeguard. Which TWO actions form the most appropriate pair? (Select TWO.)

  1. Deploy a supported inline IPS or enforcement control at the correct traffic choke point with tuned prevention signatures.
  2. Test agent kernel compatibility and fail-closed behavior against real application performance requirements.
  3. Use distributed firewall microsegmentation at workload interfaces to enforce east-west application policy.
  4. Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.
  5. Use next-generation firewall application identification with policy tied to app identity and validated TLS visibility constraints.

Explanation

Correct Answers

B:

This is the appropriate change-control precaution: Test agent kernel compatibility and fail-closed behavior against real application performance requirements. That guard reduces the case-specific exposure IP-only controls can lose process context when ephemeral workloads share addresses or nodes. The paired technical correction is Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context. Completion is judged using Unapproved container process egress is detected and blocked without interrupting authorized pod communications.

D:

This is the targeted repair: Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context. It must be paired with a separately selected risk-control action: Test agent kernel compatibility and fail-closed behavior against real application performance requirements. Together these address the concern IP-only controls can lose process context when ephemeral workloads share addresses or nodes. Verify the outcome using Unapproved container process egress is detected and blocked without interrupting authorized pod communications.

Incorrect Answers

A:

The competing intervention is relevant to ids detects intrusion but cannot stop repeated attack, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

C:

The competing intervention is relevant to east-west workload traffic bypasses perimeter ngfw, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

E:

The competing intervention is relevant to ngfw application identification absent for unknown tls flow, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

Question 225

Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. Following the authorized correction, which observed result would most directly verify that the ORIGINAL problem has been solved?

  1. Public-network probes cannot reach restricted laptop services while permitted outbound work continues.
  2. The approved test attack signature is blocked in the inline path and benign traffic remains permitted.
  3. Unapproved container process egress is detected and blocked without interrupting authorized pod communications.
  4. Only approved industrial protocols pass and device throughput remains within validated capacity.

Explanation

Correct Answer

C:

This result directly proves the approved repair addressed the case: Unapproved container process egress is detected and blocked without interrupting authorized pod communications. The planned intervention was Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context. For independent corroboration, also perform Compare pod identity and allowed egress destinations with actual node-level socket events. A successful command alone would not establish this end-user outcome.

Incorrect Answers

A:

The proposed measure is relevant to host firewall required for roaming laptop on public wi-fi, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

B:

The proposed measure is relevant to ids detects intrusion but cannot stop repeated attack, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

D:

The proposed measure is relevant to traditional acl needed instead of deep packet inspection, not the reported fault: Containers are created and removed in seconds, but a static perimeter rule cannot identify which process inside a node is making unexpected outbound calls. To differentiate the failure, inspect workload-to-process flow attribution for a short-lived test container. The matching corrective response is to use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.

Question 226

A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. A security architecture engineer is investigating this fictional security design case. Which correction most directly addresses the observed fault without changing unrelated security services?

  1. Place WAF inspection on supported HTTP application entry points and separate database access with network or workload policy controls.
  2. Use a supported eBPF-based runtime observability and enforcement layer tied to workload identity and container context.
  3. Use distributed firewall microsegmentation at workload interfaces to enforce east-west application policy.
  4. Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

Explanation

Correct Answer

D:

The relevant facts are: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. The supported corrective response is Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement. Confirm the suspected cause using Document required protocols address ranges and router performance capacity. Following the change, success means Only approved industrial protocols pass and device throughput remains within validated capacity.

Incorrect Answers

A:

The alternative is relevant to waf expected to inspect database layer attacks, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

B:

The alternative is relevant to ebpf runtime policy for ephemeral container workloads, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

C:

The alternative is relevant to east-west workload traffic bypasses perimeter ngfw, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

Question 227

A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. Before making a change, the engineer wants two independent checks that directly test the suspected fault. Which TWO observations should be collected? (Select TWO.)

  1. Inspect whether the sensor receives mirrored packets or sits inline in the forwarded path.
  2. Compare the proposed feature demands with supported hardware and nearby gateway capabilities.
  3. Trace source and destination workload placement and the actual same-host traffic path.
  4. Document required protocols address ranges and router performance capacity.
  5. Map the flow protocols and determine which requests actually pass through the WAF listener.

Explanation

Correct Answers

B:

This check directly targets the reported failure: Compare the proposed feature demands with supported hardware and nearby gateway capabilities. It independently corroborates Document required protocols address ranges and router performance capacity. Together they provide evidence before implementing Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement. A successful resolution is Only approved industrial protocols pass and device throughput remains within validated capacity.

D:

This check directly targets the reported failure: Document required protocols address ranges and router performance capacity. It independently corroborates Compare the proposed feature demands with supported hardware and nearby gateway capabilities. Together they provide evidence before implementing Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement. A successful resolution is Only approved industrial protocols pass and device throughput remains within validated capacity.

Incorrect Answers

A:

The suggested fix is relevant to ids detects intrusion but cannot stop repeated attack, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

C:

The suggested fix is relevant to east-west workload traffic bypasses perimeter ngfw, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

E:

The suggested fix is relevant to waf expected to inspect database layer attacks, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

Question 228

A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. If this condition is left unresolved, which operational or security consequence follows most directly from the available facts?

  1. IP-only controls can lose process context when ephemeral workloads share addresses or nodes.
  2. A north-south perimeter firewall cannot inspect same-cluster traffic that never traverses it.
  3. Overengineering inspection on unsupported hardware can cause outages without adding meaningful risk reduction.
  4. A layer-seven HTTP inspection control cannot replace authorization on non-HTTP database ports.

Explanation

Correct Answer

C:

The case describes A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. The specific consequence supported by those conditions is Overengineering inspection on unsupported hardware can cause outages without adding meaningful risk reduction. This is a plausible unresolved risk, not an assertion that damage has already occurred. The corrective control remains Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

Incorrect Answers

A:

That option is relevant to ebpf runtime policy for ephemeral container workloads, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

B:

That option is relevant to east-west workload traffic bypasses perimeter ngfw, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

D:

That option is relevant to waf expected to inspect database layer attacks, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

Question 229

A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. A change reviewer requires BOTH the corrective step and a matching risk-control safeguard. Which TWO actions form the most appropriate pair? (Select TWO.)

  1. Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.
  2. Place WAF inspection on supported HTTP application entry points and separate database access with network or workload policy controls.
  3. Use selective policy-driven TLS inspection where permitted, with documented sensitive-category bypass and trusted certificate distribution.
  4. Deploy a supported inline IPS or enforcement control at the correct traffic choke point with tuned prevention signatures.
  5. Keep logging and upstream threat inspection as separate controls where deep inspection is required.

Explanation

Correct Answers

A:

This is the targeted repair: Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement. It must be paired with a separately selected risk-control action: Keep logging and upstream threat inspection as separate controls where deep inspection is required. Together these address the concern Overengineering inspection on unsupported hardware can cause outages without adding meaningful risk reduction. Verify the outcome using Only approved industrial protocols pass and device throughput remains within validated capacity.

E:

This is the appropriate change-control precaution: Keep logging and upstream threat inspection as separate controls where deep inspection is required. That guard reduces the case-specific exposure Overengineering inspection on unsupported hardware can cause outages without adding meaningful risk reduction. The paired technical correction is Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement. Completion is judged using Only approved industrial protocols pass and device throughput remains within validated capacity.

Incorrect Answers

B:

The competing intervention is relevant to waf expected to inspect database layer attacks, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

C:

The competing intervention is relevant to encrypted tls traffic needs selective decryption governance, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

D:

The competing intervention is relevant to ids detects intrusion but cannot stop repeated attack, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

Question 230

A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. Following the authorized correction, which observed result would most directly verify that the ORIGINAL problem has been solved?

  1. Malicious HTTP test requests are inspected while unauthorized database connections are blocked separately.
  2. Only approved industrial protocols pass and device throughput remains within validated capacity.
  3. Unapproved container process egress is detected and blocked without interrupting authorized pod communications.
  4. Unapproved east-west lateral traffic is denied at workload boundaries without breaking necessary services.

Explanation

Correct Answer

B:

This result directly proves the approved repair addressed the case: Only approved industrial protocols pass and device throughput remains within validated capacity. The planned intervention was Use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement. For independent corroboration, also perform Compare the proposed feature demands with supported hardware and nearby gateway capabilities. A successful command alone would not establish this end-user outcome.

Incorrect Answers

A:

The proposed measure is relevant to waf expected to inspect database layer attacks, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

C:

The proposed measure is relevant to ebpf runtime policy for ephemeral container workloads, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

D:

The proposed measure is relevant to east-west workload traffic bypasses perimeter ngfw, not the reported fault: A low-power industrial router must filter traffic by fixed source subnets and transport ports, but a proposed resource-heavy NGFW cannot be supported by its platform. To differentiate the failure, document required protocols address ranges and router performance capacity. The matching corrective response is to use a simple stateful or routed access-control architecture at a suitable gateway matched to the actual limited filtering requirement.

Designing Cisco Security Infrastructure (300-745) Practice Tests