cert
cert-1
cert-2

Pass Cisco 200-901 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
200-901 Exam - Verified By Experts
200-901 Premium Bundle
$29.98

200-901 Premium Bundle

$79.99
$109.97
  • Premium File 431 Questions & Answers. Last update: Nov 24, 2026
  • Training Course 11 Video Lectures
  • Study Guide 1212 Pages
 
$109.97
$79.99
accept 31 downloads in last 7 days
block-screenshots
Purchase Cisco 200-901 Exam Training Products Individually
Cisco 200-901 Premium File
Premium File 431 Q&A
$76.99$69.99
Cisco 200-901 Video Training Course
Training Course 11 Lectures
$21.99 $19.99
Cisco 200-901 PDF Study Guide
Study Guide 1212 Pages
$21.99 $19.99
Cisco 200-901 Practice Test 33

Question 320

For an original CCNA Automation educational scenario, consider: An operator tries to change an ACI contract by issuing an ordinary switch CLI command rather than using the APIC model and policy objects. Select TWO complementary steps: the targeted correction and its strongest prechange validation.

  1. Change: Query and modify the documented APIC managed objects with their distinguished names and correct tenant/application context.
  2. Change: Traverse the documented Meraki organization, network and device or client resources using explicit IDs and the correct endpoint for each desired object.
  3. Check: Inspect managed object distinguished names, parent tenant and returned class plus an isolated policy-change preview before committing.
  4. Check: Test listing spaces, resolving a known space ID, reading permitted memberships and posting a non-sensitive sandbox message.
  5. Update an arbitrary same-named EPG without tenant qualification because all APIC objects are globally interchangeable.

Explanation

Correct Answer

A:

ACI exposes a hierarchical policy object model through APIC; EPG, bridge-domain and contract objects have relationships distinct from flat device CLI lines. Acceptance: Only the intended tenant policy objects are read or changed and referenced EPG relationships remain valid.

C:

ACI exposes a hierarchical policy object model through APIC; EPG, bridge-domain and contract objects have relationships distinct from flat device CLI lines. Required intervention: Query and modify the documented APIC managed objects with their distinguished names and correct tenant/application context.

Incorrect Answers

B:

Change: Traverse the documented Meraki organization, network and device or client resources using explicit IDs and the correct endpoint for each desired object. ACI exposes a hierarchical policy object model through APIC; EPG, bridge-domain and contract objects have relationships distinct from flat device CLI lines.

D:

Check: Test listing spaces, resolving a known space ID, reading permitted memberships and posting a non-sensitive sandbox message. ACI exposes a hierarchical policy object model through APIC; EPG, bridge-domain and contract objects have relationships distinct from flat device CLI lines.

E:

ACI exposes a hierarchical policy object model through APIC; EPG, bridge-domain and contract objects have relationships distinct from flat device CLI lines.

Question 321

A network automation engineer is examining this network automation situation: A WAN operations team needs centralized device status, but a script scrapes CLI output separately from every edge while ignoring its available SD-WAN manager APIs. A proposed shortcut is: Claim a successful login to SD-WAN Manager proves every transport tunnel and application path is healthy. What should the network automation engineer recommend as the narrowly scoped correction? Select ONE best answer.

  1. Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics.
  2. Choose AXL for supported administrative configuration operations and UDS for appropriate user and device lookup or self-service functions under least privilege.
  3. Model the intended network service through supported Cisco NSO service abstractions with transactional orchestration and device-level reconciliation.
  4. Claim a successful login to SD-WAN Manager proves every transport tunnel and application path is healthy.

Explanation

Correct Answer

A:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

Incorrect Answers

B:

Choose AXL for supported administrative configuration operations and UDS for appropriate user and device lookup or self-service functions under least privilege. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

C:

Model the intended network service through supported Cisco NSO service abstractions with transactional orchestration and device-level reconciliation. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

Question 322

A Cisco network automation implementation review finds: A WAN operations team needs centralized device status, but a script scrapes CLI output separately from every edge while ignoring its available SD-WAN manager APIs. The team proposes: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Which engineering principle most strongly supports the recommended response? Select ONE best answer.

  1. Cisco ISE focuses on identity-based network access, Secure Endpoint on endpoint protection, Secure Firewall on network enforcement and XDR on detection and incident correlation.
  2. ACI exposes a hierarchical policy object model through APIC; EPG, bridge-domain and contract objects have relationships distinct from flat device CLI lines.
  3. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.
  4. RESTCONF exposes YANG-modeled resources over HTTP whereas NX-API may expose structured CLI interfaces with different request envelopes and capabilities.

Explanation

Correct Answer

C:

Demonstrable success requires: The automation reports actual edge and overlay status without interpreting controller connectivity as proof that all user traffic is healthy.

Incorrect Answers

A:

Cisco ISE focuses on identity-based network access, Secure Endpoint on endpoint protection, Secure Firewall on network enforcement and XDR on detection and incident correlation. This option addresses a different network automation topic (Cisco security platform API differentiation) rather than the documented Cisco Catalyst SD-WAN controller APIs decision. The case-specific mechanism is: The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The relevant action is: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Discriminating evidence: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.

B:

ACI exposes a hierarchical policy object model through APIC; EPG, bridge-domain and contract objects have relationships distinct from flat device CLI lines. This option addresses a different network automation topic (ACI APIC objects and tenant isolation) rather than the documented Cisco Catalyst SD-WAN controller APIs decision. The case-specific mechanism is: The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The relevant action is: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Discriminating evidence: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.

D:

RESTCONF exposes YANG-modeled resources over HTTP whereas NX-API may expose structured CLI interfaces with different request envelopes and capabilities. This option addresses a different network automation topic (IOS XE RESTCONF and NX-OS NX-API) rather than the documented Cisco Catalyst SD-WAN controller APIs decision. The case-specific mechanism is: The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The relevant action is: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Discriminating evidence: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.

Question 323

The network automation team has not yet approved changes. Current evidence indicates: A WAN operations team needs centralized device status, but a script scrapes CLI output separately from every edge while ignoring its available SD-WAN manager APIs. Which evidence best tests the technical diagnosis before approving a disruptive change? Select ONE best answer.

  1. Cross-check organization ID, network ID, endpoint path and two known device serial numbers versus one observed client in a sandbox.
  2. Check the registered fabric and server inventory, identity policy scope, API permissions and resulting profile assignment in a lab domain.
  3. Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.
  4. Compare the documented method contracts, service account permissions and a read-only lookup versus a staged configuration change in lab CUCM.

Explanation

Correct Answer

C:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. Confirm afterward that: The automation reports actual edge and overlay status without interpreting controller connectivity as proof that all user traffic is healthy.

Incorrect Answers

A:

Cross-check organization ID, network ID, endpoint path and two known device serial numbers versus one observed client in a sandbox. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

B:

Check the registered fabric and server inventory, identity policy scope, API permissions and resulting profile assignment in a lab domain. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

Compare the documented method contracts, service account permissions and a read-only lookup versus a staged configuration change in lab CUCM. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

Question 324

A candidate correction has been tested and the platform team requires a post-change acceptance check. Original problem: A WAN operations team needs centralized device status, but a script scrapes CLI output separately from every edge while ignoring its available SD-WAN manager APIs. The service owner needs positive and negative results and evidence that legitimate data workflows still function. Which acceptance result demonstrates correct network automation behavior without disrupting authorized workflows? Select ONE best answer.

  1. The automation reports actual edge and overlay status without interpreting controller connectivity as proof that all user traffic is healthy.
  2. Only the intended tenant policy objects are read or changed and referenced EPG relationships remain valid.
  3. The intended servers receive approved compute profiles without cross-domain device confusion or unexpected access.
  4. The response returns intended modeled interface state and the experiment does not modify production devices.

Explanation

Correct Answer

A:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The result must be validated using the documented device, service or access context.

Incorrect Answers

B:

Only the intended tenant policy objects are read or changed and referenced EPG relationships remain valid. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

C:

The intended servers receive approved compute profiles without cross-domain device confusion or unexpected access. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

The response returns intended modeled interface state and the experiment does not modify production devices. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

Question 325

An implementation sign-off request identifies the following problem: A WAN operations team needs centralized device status, but a script scrapes CLI output separately from every edge while ignoring its available SD-WAN manager APIs. Which paired technical change and validation should close the implementation review? Select ONE best answer.

  1. Change: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Verify: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.
  2. Change: Instantiate the supported Cisco SDK client with documented authentication configuration and invoke its exact documented resource method and parameters. Verify: Consult the pinned SDK version documentation and run a sandbox test that lists one authorized resource without exposing credentials.
  3. Change: Query and modify the documented APIC managed objects with their distinguished names and correct tenant/application context. Verify: Inspect managed object distinguished names, parent tenant and returned class plus an isolated policy-change preview before committing.
  4. Change: Use the documented Catalyst Center token workflow and the appropriate network-device or client endpoint based on the requested data. Verify: Compare a known switch ID and known endpoint MAC against their separate API responses with the correct token and site filters.

Explanation

Correct Answer

A:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The change is successful only when: The automation reports actual edge and overlay status without interpreting controller connectivity as proof that all user traffic is healthy.

Incorrect Answers

B:

Change: Instantiate the supported Cisco SDK client with documented authentication configuration and invoke its exact documented resource method and parameters.

C:

Change: Query and modify the documented APIC managed objects with their distinguished names and correct tenant/application context. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

Change: Use the documented Catalyst Center token workflow and the appropriate network-device or client endpoint based on the requested data.

Question 326

A network automation engineer is examining this network automation situation: A workflow confuses overlay control status with application-level health and marks every transport up merely because a management request returned 200. A proposed shortcut is: Claim a successful login to SD-WAN Manager proves every transport tunnel and application path is healthy. What should the network automation engineer recommend as the narrowly scoped correction? Select ONE best answer.

  1. Claim a successful login to SD-WAN Manager proves every transport tunnel and application path is healthy.
  2. Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics.
  3. Model the intended network service through supported Cisco NSO service abstractions with transactional orchestration and device-level reconciliation.
  4. Select UCS Manager or Cisco Intersight capabilities according to managed compute domain, policy scope and supported API resource model.

Explanation

Correct Answer

B:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

Incorrect Answers

A:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. Use this instead: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics.

C:

Model the intended network service through supported Cisco NSO service abstractions with transactional orchestration and device-level reconciliation. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

Select UCS Manager or Cisco Intersight capabilities according to managed compute domain, policy scope and supported API resource model. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

Question 327

A Cisco network automation implementation review finds: A workflow confuses overlay control status with application-level health and marks every transport up merely because a management request returned 200. The team proposes: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Which engineering principle most strongly supports the recommended response? Select ONE best answer.

  1. Cisco ISE focuses on identity-based network access, Secure Endpoint on endpoint protection, Secure Firewall on network enforcement and XDR on detection and incident correlation.
  2. An SDK wraps transport, pagination and authentication details only according to the versioned library contract; raw REST endpoints are not automatically Python method names.
  3. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.
  4. Controller inventory APIs and client-assurance APIs represent different entity types; authentication and RBAC are required for both.

Explanation

Correct Answer

C:

Demonstrable success requires: The automation reports actual edge and overlay status without interpreting controller connectivity as proof that all user traffic is healthy.

Incorrect Answers

A:

Cisco ISE focuses on identity-based network access, Secure Endpoint on endpoint protection, Secure Firewall on network enforcement and XDR on detection and incident correlation. This option addresses a different network automation topic (Cisco security platform API differentiation) rather than the documented Cisco Catalyst SD-WAN controller APIs decision. The case-specific mechanism is: The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The relevant action is: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Discriminating evidence: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.

B:

An SDK wraps transport, pagination and authentication details only according to the versioned library contract; raw REST endpoints are not automatically Python method names. This option addresses a different network automation topic (Cisco SDK client initialization and documentation) rather than the documented Cisco Catalyst SD-WAN controller APIs decision. The case-specific mechanism is: The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The relevant action is: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Discriminating evidence: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.

D:

Controller inventory APIs and client-assurance APIs represent different entity types; authentication and RBAC are required for both. This option addresses a different network automation topic (Catalyst Center device and client API scopes) rather than the documented Cisco Catalyst SD-WAN controller APIs decision. The case-specific mechanism is: The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The relevant action is: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics. Discriminating evidence: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.

Question 328

The network automation team has not yet approved changes. Current evidence indicates: A workflow confuses overlay control status with application-level health and marks every transport up merely because a management request returned 200. Which evidence best tests the technical diagnosis before approving a disruptive change? Select ONE best answer.

  1. Trace a sample event to its owning platform and test a read-only authorized endpoint before designing any containment command.
  2. Inspect managed object distinguished names, parent tenant and returned class plus an isolated policy-change preview before committing.
  3. Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.
  4. Cross-check organization ID, network ID, endpoint path and two known device serial numbers versus one observed client in a sandbox.

Explanation

Correct Answer

C:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. This check tests the actual network, API or deployment boundary before an operationally risky change.

Incorrect Answers

A:

Trace a sample event to its owning platform and test a read-only authorized endpoint before designing any containment command. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

B:

Inspect managed object distinguished names, parent tenant and returned class plus an isolated policy-change preview before committing. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

Cross-check organization ID, network ID, endpoint path and two known device serial numbers versus one observed client in a sandbox. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

Question 329

A candidate correction has been tested and the platform team requires a post-change acceptance check. Original problem: A workflow confuses overlay control status with application-level health and marks every transport up merely because a management request returned 200. The service owner needs positive and negative results and evidence that legitimate data workflows still function. Which acceptance result demonstrates correct network automation behavior without disrupting authorized workflows? Select ONE best answer.

  1. The response returns intended modeled interface state and the experiment does not modify production devices.
  2. The automation reports actual edge and overlay status without interpreting controller connectivity as proof that all user traffic is healthy.
  3. The workflow retrieves or modifies the right security object's state and does not request privileges from unrelated security products.
  4. Only the intended tenant policy objects are read or changed and referenced EPG relationships remain valid.

Explanation

Correct Answer

B:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. The approved implementation step was: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics.

Incorrect Answers

A:

The response returns intended modeled interface state and the experiment does not modify production devices. A workflow confuses overlay control status with application-level health and marks every transport up merely because a management request returned 200.

C:

The workflow retrieves or modifies the right security object's state and does not request privileges from unrelated security products. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

Only the intended tenant policy objects are read or changed and referenced EPG relationships remain valid. A workflow confuses overlay control status with application-level health and marks every transport up merely because a management request returned 200.

Question 330

For an original CCNA Automation educational scenario, consider: A workflow confuses overlay control status with application-level health and marks every transport up merely because a management request returned 200. Select TWO complementary steps: the targeted correction and its strongest prechange validation.

  1. Claim a successful login to SD-WAN Manager proves every transport tunnel and application path is healthy.
  2. Check: Trace a sample event to its owning platform and test a read-only authorized endpoint before designing any containment command.
  3. Check: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.
  4. Change: Select UCS Manager or Cisco Intersight capabilities according to managed compute domain, policy scope and supported API resource model.
  5. Change: Retrieve supported controller device and transport data through documented Catalyst SD-WAN APIs and distinguish inventory, control connections and application metrics.

Explanation

Correct Answer

C:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. Acceptance: The automation reports actual edge and overlay status without interpreting controller connectivity as proof that all user traffic is healthy.

E:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views. Evidence: Compare known WAN edge identifiers, control connection state and link health against an approved test site's controller dashboard.

Incorrect Answers

A:

The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

B:

Check: Trace a sample event to its owning platform and test a read-only authorized endpoint before designing any containment command. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

D:

Change: Select UCS Manager or Cisco Intersight capabilities according to managed compute domain, policy scope and supported API resource model. The SD-WAN controller exposes centrally aggregated overlay and device information, while different API resources represent different operational views.

DevNet Associate (DEVASC) (200-901) Practice Tests