Amazon AWS Certified Solutions Architect - Associate SAA-C03 Practice Test 71
Question 700
A Java service starts slowly and scale-out begins only after a traffic peak. What economical capacity strategy can help?
- Use target-tracking or scheduled scale-in with a safe minimum capacity.
- Evaluate a compute-optimized EC2 family consistent with the application's architecture.
- Use predictive or scheduled scaling for known demand while retaining minimum safe capacity.
- Automate start and stop schedules for approved nonproduction instances.
Explanation
Correct Answer
C:Prewarming only for justified peaks can reduce long periods of idle overprovisioning. Compare prepeak readiness and daily total instance-hours.
Incorrect Answers
A:Elastic scaling aligns billed fleet size with demand rather than permanently provisioned peak capacity. Use predictive or scheduled scaling for known demand while retaining minimum safe capacity. Compare prepeak readiness and daily total instance-hours.
B:Matching capacity to the real bottleneck can avoid paying for unused memory. Use predictive or scheduled scaling for known demand while retaining minimum safe capacity. Compare prepeak readiness and daily total instance-hours.
D:Stopping unneeded compute removes instance running charges while leaving storage charges to budget separately. Prewarming only for justified peaks can reduce long periods of idle overprovisioning.
Question 701
A company has steady compute spending across EC2 instance families, AWS Fargate and Lambda. Which discount commitment has broad flexibility?
- Model a flexible commitment against realistic workload migration risk and potential unused spend.
- Compute Savings Plans may cover qualifying Fargate usage, while EC2 Instance Savings Plans do not.
- Consider a Compute Savings Plan based on forecast qualifying usage.
- Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage.
Explanation
Correct Answer
C:Compute Savings Plans can cover eligible EC2, Fargate and Lambda usage with a flexible spend commitment. Inspect eligible usage and commitment coverage in Cost Explorer.
Incorrect Answers
A:A longer commitment can improve rates but raises exposure to changing usage patterns. Consider a Compute Savings Plan based on forecast qualifying usage. Inspect eligible usage and commitment coverage in Cost Explorer.
B:Discount-plan eligibility depends on compute service and commitment type. Consider a Compute Savings Plan based on forecast qualifying usage. Inspect eligible usage and commitment coverage in Cost Explorer.
D:Instance Savings Plans apply to an eligible regional instance family with narrower scope than Compute Savings Plans. Consider a Compute Savings Plan based on forecast qualifying usage. Inspect eligible usage and commitment coverage in Cost Explorer.
Question 702
An EC2 fleet has stable Region and instance family and wants deeper discount flexibility within that family. What commitment may fit?
- Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage.
- Compute Savings Plans may cover qualifying Fargate usage, while EC2 Instance Savings Plans do not.
- Use an appropriate EC2 Capacity Reservation or eligible zonal Reserved Instance as required.
- Consider a Compute Savings Plan based on forecast qualifying usage.
Explanation
Correct Answer
A:Instance Savings Plans apply to an eligible regional instance family with narrower scope than Compute Savings Plans. Compare compatible instance-hours and proposed commitment utilization.
Incorrect Answers
B:Discount-plan eligibility depends on compute service and commitment type. Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage. Compare compatible instance-hours and proposed commitment utilization.
C:Savings Plans reduce eligible compute cost but do not themselves reserve AZ capacity. Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage. Compare compatible instance-hours and proposed commitment utilization.
D:Compute Savings Plans can cover eligible EC2, Fargate and Lambda usage with a flexible spend commitment. Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage. Compare compatible instance-hours and proposed commitment utilization.
Question 703
A customer must reserve scarce capacity in a particular Availability Zone for an important workload. Which purchasing feature provides capacity reservation, not just billing discount?
- Compute Savings Plans may cover qualifying Fargate usage, while EC2 Instance Savings Plans do not.
- Distinguish discount-only regional RI benefits from actual capacity reservation mechanisms.
- Use an appropriate EC2 Capacity Reservation or eligible zonal Reserved Instance as required.
- Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage.
Explanation
Correct Answer
C:Savings Plans reduce eligible compute cost but do not themselves reserve AZ capacity. Test launch capacity in the reserved AZ and inspect active reservation.
Incorrect Answers
A:Discount-plan eligibility depends on compute service and commitment type. Use an appropriate EC2 Capacity Reservation or eligible zonal Reserved Instance as required. Test launch capacity in the reserved AZ and inspect active reservation.
B:A billing discount does not universally ensure AZ-specific instance availability. Use an appropriate EC2 Capacity Reservation or eligible zonal Reserved Instance as required. Test launch capacity in the reserved AZ and inspect active reservation.
D:Instance Savings Plans apply to an eligible regional instance family with narrower scope than Compute Savings Plans. Use an appropriate EC2 Capacity Reservation or eligible zonal Reserved Instance as required. Test launch capacity in the reserved AZ and inspect active reservation.
Question 704
A team purchases savings commitments based on peak Friday traffic and underutilizes them on quiet days. How should the amount be sized?
- Model a flexible commitment against realistic workload migration risk and potential unused spend.
- Base commitments on sustained eligible baseline usage rather than occasional peak hours.
- Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage.
- Consider a Compute Savings Plan based on forecast qualifying usage.
Explanation
Correct Answer
B:Commitment charges apply even if actual eligible usage falls below the committed spend. Compare hourly usage distribution with commitment utilization.
Incorrect Answers
A:A longer commitment can improve rates but raises exposure to changing usage patterns. Base commitments on sustained eligible baseline usage rather than occasional peak hours. Compare hourly usage distribution with commitment utilization.
C:Instance Savings Plans apply to an eligible regional instance family with narrower scope than Compute Savings Plans. Base commitments on sustained eligible baseline usage rather than occasional peak hours. Compare hourly usage distribution with commitment utilization.
D:Compute Savings Plans can cover eligible EC2, Fargate and Lambda usage with a flexible spend commitment. Base commitments on sustained eligible baseline usage rather than occasional peak hours. Compare hourly usage distribution with commitment utilization.
Question 705
An organization holds an old Standard Reserved Instance but plans to move to a different instance family. What economic risk needs review?
- Model a flexible commitment against realistic workload migration risk and potential unused spend.
- Check reservation modification or exchange flexibility and compatible usage before migration.
- Consider a Compute Savings Plan based on forecast qualifying usage.
- Compute Savings Plans may cover qualifying Fargate usage, while EC2 Instance Savings Plans do not.
Explanation
Correct Answer
B:Reservation discounts can be constrained by attributes, so an architecture change may strand coverage. Compare proposed instance attributes with active reservation matching.
Incorrect Answers
A:A longer commitment can improve rates but raises exposure to changing usage patterns. Check reservation modification or exchange flexibility and compatible usage before migration. Compare proposed instance attributes with active reservation matching.
C:Compute Savings Plans can cover eligible EC2, Fargate and Lambda usage with a flexible spend commitment. Check reservation modification or exchange flexibility and compatible usage before migration. Compare proposed instance attributes with active reservation matching.
D:Discount-plan eligibility depends on compute service and commitment type. Check reservation modification or exchange flexibility and compatible usage before migration. Compare proposed instance attributes with active reservation matching.
Question 706
An application migrates from EC2 to Fargate, and finance assumes an EC2 Instance Savings Plan still covers it. What distinction matters?
- Compute Savings Plans may cover qualifying Fargate usage, while EC2 Instance Savings Plans do not.
- Consider a Compute Savings Plan based on forecast qualifying usage.
- Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage.
- Base commitments on sustained eligible baseline usage rather than occasional peak hours.
Explanation
Correct Answer
A:Discount-plan eligibility depends on compute service and commitment type. Check projected Fargate charges against the plan's eligible coverage.
Incorrect Answers
B:Compute Savings Plans can cover eligible EC2, Fargate and Lambda usage with a flexible spend commitment. Compute Savings Plans may cover qualifying Fargate usage, while EC2 Instance Savings Plans do not. Check projected Fargate charges against the plan's eligible coverage.
C:Instance Savings Plans apply to an eligible regional instance family with narrower scope than Compute Savings Plans. Compute Savings Plans may cover qualifying Fargate usage, while EC2 Instance Savings Plans do not. Check projected Fargate charges against the plan's eligible coverage.
D:Commitment charges apply even if actual eligible usage falls below the committed spend. Discount-plan eligibility depends on compute service and commitment type.
Question 707
A team wants the lower price of a Reserved Instance and also assumes every Standard RI guarantees a specific AZ launch slot. What needs correction?
- Distinguish discount-only regional RI benefits from actual capacity reservation mechanisms.
- Use an appropriate EC2 Capacity Reservation or eligible zonal Reserved Instance as required.
- Evaluate an EC2 Instance Savings Plan for the predictable instance-family usage.
- Consider a Compute Savings Plan based on forecast qualifying usage.
Explanation
Correct Answer
A:A billing discount does not universally ensure AZ-specific instance availability. Inspect scope of the reservation and verify capacity at the chosen AZ.
Incorrect Answers
B:Savings Plans reduce eligible compute cost but do not themselves reserve AZ capacity. Distinguish discount-only regional RI benefits from actual capacity reservation mechanisms. Inspect scope of the reservation and verify capacity at the chosen AZ.
C:Instance Savings Plans apply to an eligible regional instance family with narrower scope than Compute Savings Plans. Distinguish discount-only regional RI benefits from actual capacity reservation mechanisms. Inspect scope of the reservation and verify capacity at the chosen AZ.
D:Compute Savings Plans can cover eligible EC2, Fargate and Lambda usage with a flexible spend commitment. A billing discount does not universally ensure AZ-specific instance availability.
Question 708
Management wants to buy a three-year compute commitment despite imminent uncertainty about workload location. What should guide the decision?
- Model a flexible commitment against realistic workload migration risk and potential unused spend.
- Check reservation modification or exchange flexibility and compatible usage before migration.
- Consider a Compute Savings Plan based on forecast qualifying usage.
- Base commitments on sustained eligible baseline usage rather than occasional peak hours.
Explanation
Correct Answer
A:A longer commitment can improve rates but raises exposure to changing usage patterns. Perform downside utilization analysis before committing.
Incorrect Answers
B:Reservation discounts can be constrained by attributes, so an architecture change may strand coverage. Model a flexible commitment against realistic workload migration risk and potential unused spend. Perform downside utilization analysis before committing.
C:Compute Savings Plans can cover eligible EC2, Fargate and Lambda usage with a flexible spend commitment. Model a flexible commitment against realistic workload migration risk and potential unused spend. Perform downside utilization analysis before committing.
D:Commitment charges apply even if actual eligible usage falls below the committed spend. Model a flexible commitment against realistic workload migration risk and potential unused spend. Perform downside utilization analysis before committing.
Question 709
A function runs for milliseconds a few times per day but its team keeps an EC2 server running 24/7. Which design may reduce idle compute cost?
- Use an eligible long-running container or batch platform because Lambda has a maximum execution duration.
- Benchmark alternative Lambda memory configurations using duration and cost together.
- Schedule one-off Fargate tasks and remove idle service replicas.
- Use an appropriately sized Lambda function for eligible short sporadic executions.
Explanation
Correct Answer
D:Lambda pricing follows invocation and duration rather than always-on instance-hours. Compare projected monthly invocations and duration to EC2 running hours.
Incorrect Answers
A:Compute selection must satisfy execution limits before cost comparison. Use an appropriately sized Lambda function for eligible short sporadic executions. Compare projected monthly invocations and duration to EC2 running hours.
B:Lambda CPU scales with memory, so lower memory may run longer; minimum GB-seconds is not always lowest cost. Use an appropriately sized Lambda function for eligible short sporadic executions. Compare projected monthly invocations and duration to EC2 running hours.
C:Paying for active tasks only during job execution can eliminate unnecessary always-on task-hours. Use an appropriately sized Lambda function for eligible short sporadic executions. Compare projected monthly invocations and duration to EC2 running hours.
Question 710
A Lambda image-processing function uses maximum memory despite low utilization. What optimization controls both cost and latency?
- Use an eligible long-running container or batch platform because Lambda has a maximum execution duration.
- Schedule provisioned concurrency only during justified low-latency demand periods.
- Use an appropriately sized Lambda function for eligible short sporadic executions.
- Benchmark alternative Lambda memory configurations using duration and cost together.
Explanation
Correct Answer
D:Lambda CPU scales with memory, so lower memory may run longer; minimum GB-seconds is not always lowest cost. Compare total request charges and p95 duration across memory sizes.
Incorrect Answers
A:Compute selection must satisfy execution limits before cost comparison. Benchmark alternative Lambda memory configurations using duration and cost together. Compare total request charges and p95 duration across memory sizes.
B:Provisioned concurrency has a time-based cost even when requests are absent. Benchmark alternative Lambda memory configurations using duration and cost together. Compare total request charges and p95 duration across memory sizes.
C:Lambda pricing follows invocation and duration rather than always-on instance-hours. Benchmark alternative Lambda memory configurations using duration and cost together. Compare total request charges and p95 duration across memory sizes.