Amazon AWS Certified Solutions Architect - Associate SAA-C03 Practice Test 49
Question 480
An analytics team wants lower scan volume for a columnar S3 dataset queried by Athena. What object layout helps?
- Cache eligible S3 objects using CloudFront near users.
- Store partitioned Parquet objects aligned with common query predicates.
- Evaluate S3 Transfer Acceleration for supported distant clients and buckets.
- Use multipart upload with retries of failed parts.
Explanation
Correct Answer
B:Columnar and partitioned data reduce unnecessary scanned bytes. Compare bytes scanned before and after conversion.
Incorrect Answers
A:Edge caches reduce long-distance origin fetches for repeat reads. Store partitioned Parquet objects aligned with common query predicates. Compare bytes scanned before and after conversion.
C:Transfer Acceleration can use CloudFront edge networking to improve distant upload paths. Store partitioned Parquet objects aligned with common query predicates. Compare bytes scanned before and after conversion.
D:Multipart transfers support parallelism and part-level recovery for large objects. Store partitioned Parquet objects aligned with common query predicates. Compare bytes scanned before and after conversion.
Question 481
A company is migrating a large on-premises SMB file share to Amazon EFS. It needs scheduled incremental transfers, verification of copied content, and private access to the destination filesystem. Which TWO capabilities are central to the migration? (Select TWO.)
- Enable the task’s supported verification and incremental-copy behavior for the specified file-set.
- Mount EFS through a public S3 website endpoint and copy files using anonymous HTTPS PUT.
- Assume EFS automatically discovers and copies data from every on-premises SMB server without a transfer service.
- Delete source files before the first verification run and rely on task success messages alone.
- Use AWS DataSync with suitable on-premises agent connectivity and source/destination configuration.
Explanation
Correct Answers
A:DataSync can verify data transfer integrity and avoid unnecessarily recopying unchanged source files under its configured rules.
E:DataSync manages repeatable file movement from supported network shares to AWS storage with task logging and scheduling.
Incorrect Answers
B:An EFS network filesystem is not a public website endpoint; this loses the required file-protocol transfer semantics.
C:EFS storage provision alone does not perform migration; a transfer mechanism and route must be configured.
D:Destroying source data before checking integrity creates avoidable recovery risk and violates the verification requirement.
Question 482
A hybrid application needs on-premises SMB clients to access objects stored in S3 through a file interface. Which gateway fits?
- Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots.
- Use AWS Storage Gateway Tape Gateway with compatible virtual tape devices.
- Expose an NFS-only File Gateway share to Windows clients that are restricted to SMB.
- Use AWS Storage Gateway File Gateway with SMB or NFS shares.
Explanation
Correct Answer
D:File Gateway exposes object-backed file shares to supported on-premises clients. Write a file and inspect the corresponding S3 object.
Incorrect Answers
A:Volume Gateway connects local block workloads with AWS-backed recovery storage. Use AWS Storage Gateway File Gateway with SMB or NFS shares. Write a file and inspect the corresponding S3 object.
B:Tape Gateway emulates tape libraries with AWS-backed storage. Use AWS Storage Gateway File Gateway with SMB or NFS shares. Write a file and inspect the corresponding S3 object.
C:S3 File Gateway can support SMB or NFS, but an NFS-only configuration cannot meet a client-specific SMB interface requirement. Configure an SMB-capable File Gateway share for these clients.
Question 483
An on-premises database needs low-latency block volumes backed by cloud snapshots for disaster recovery. Which hybrid storage option is relevant?
- Use File Gateway for ongoing file protocol access to S3-backed objects.
- Use AWS Storage Gateway Tape Gateway with compatible virtual tape devices.
- Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots.
- Use AWS Storage Gateway File Gateway with SMB or NFS shares.
Explanation
Correct Answer
C:Volume Gateway connects local block workloads with AWS-backed recovery storage. Verify initiator connectivity and snapshot restore.
Incorrect Answers
A:DataSync is for transfers, while File Gateway exposes ongoing file shares. Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots. Verify initiator connectivity and snapshot restore.
B:Tape Gateway emulates tape libraries with AWS-backed storage. Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots. Verify initiator connectivity and snapshot restore.
D:File Gateway exposes object-backed file shares to supported on-premises clients. Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots. Verify initiator connectivity and snapshot restore.
Question 484
A tape-based backup process must preserve existing tape software while migrating storage to AWS. Which virtual storage service fits?
- Use AWS Storage Gateway File Gateway with SMB or NFS shares.
- Use AWS Storage Gateway Tape Gateway with compatible virtual tape devices.
- Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots.
- Use AWS DataSync tasks with appropriate agents and verified source/destination paths.
Explanation
Correct Answer
B:Tape Gateway emulates tape libraries with AWS-backed storage. Perform backup and restore with existing tape software.
Incorrect Answers
A:File Gateway exposes object-backed file shares to supported on-premises clients. Use AWS Storage Gateway Tape Gateway with compatible virtual tape devices. Perform backup and restore with existing tape software.
C:Volume Gateway connects local block workloads with AWS-backed recovery storage. Use AWS Storage Gateway Tape Gateway with compatible virtual tape devices. Perform backup and restore with existing tape software.
D:DataSync accelerates supported transfers and validates file metadata/integrity. Tape Gateway emulates tape libraries with AWS-backed storage.
Question 485
An EFS migration task is much slower than expected across an internet link. What infrastructure path should be assessed?
- Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots.
- Evaluate DataSync network bandwidth and Direct Connect/VPN constraints before resizing storage.
- Configure DataSync incremental tasks and supported verification settings.
- Use AWS DataSync tasks with appropriate agents and verified source/destination paths.
Explanation
Correct Answer
B:Transfer speed can be limited by source, network and DataSync task concurrency. Measure achieved Mbps against bottlenecked link capacity.
Incorrect Answers
A:Volume Gateway connects local block workloads with AWS-backed recovery storage. Evaluate DataSync network bandwidth and Direct Connect/VPN constraints before resizing storage. Measure achieved Mbps against bottlenecked link capacity.
C:Incremental synchronization and managed task history simplify retries after interruption. Evaluate DataSync network bandwidth and Direct Connect/VPN constraints before resizing storage. Measure achieved Mbps against bottlenecked link capacity.
D:DataSync accelerates supported transfers and validates file metadata/integrity. Evaluate DataSync network bandwidth and Direct Connect/VPN constraints before resizing storage. Measure achieved Mbps against bottlenecked link capacity.
Question 486
A business must transfer 800 TB from an isolated data center without enough network bandwidth. Which offline option fits?
- Consider AWS Snow Family offline data transfer options subject to current availability.
- Evaluate DataSync network bandwidth and Direct Connect/VPN constraints before resizing storage.
- Use AWS Storage Gateway Tape Gateway with compatible virtual tape devices.
- Use AWS Storage Gateway File Gateway with SMB or NFS shares.
Explanation
Correct Answer
A:Physical transfer can avoid infeasibly long internet migration windows. Compare transfer time and supported device availability.
Incorrect Answers
B:Transfer speed can be limited by source, network and DataSync task concurrency. Consider AWS Snow Family offline data transfer options subject to current availability. Compare transfer time and supported device availability.
C:Tape Gateway emulates tape libraries with AWS-backed storage. Consider AWS Snow Family offline data transfer options subject to current availability. Compare transfer time and supported device availability.
D:File Gateway exposes object-backed file shares to supported on-premises clients. Consider AWS Snow Family offline data transfer options subject to current availability. Compare transfer time and supported device availability.
Question 487
A migration uses custom rsync scripts and failures require re-copying whole directories. What managed feature reduces manual restarts?
- Use AWS DataSync tasks with appropriate agents and verified source/destination paths.
- Evaluate DataSync network bandwidth and Direct Connect/VPN constraints before resizing storage.
- Configure DataSync incremental tasks and supported verification settings.
- Use File Gateway for ongoing file protocol access to S3-backed objects.
Explanation
Correct Answer
C:Incremental synchronization and managed task history simplify retries after interruption. Interrupt and resume a test migration task.
Incorrect Answers
A:DataSync accelerates supported transfers and validates file metadata/integrity. Configure DataSync incremental tasks and supported verification settings. Interrupt and resume a test migration task.
B:Transfer speed can be limited by source, network and DataSync task concurrency. Configure DataSync incremental tasks and supported verification settings. Interrupt and resume a test migration task.
D:DataSync is for transfers, while File Gateway exposes ongoing file shares. Configure DataSync incremental tasks and supported verification settings. Interrupt and resume a test migration task.
Question 488
A company needs continuous on-premises file access after the initial one-time S3 migration. What service is different from DataSync batch transfer?
- Evaluate Storage Gateway Volume Gateway for local block access and cloud-backed snapshots.
- Use File Gateway for ongoing file protocol access to S3-backed objects.
- Use AWS Storage Gateway File Gateway with SMB or NFS shares.
- Use AWS DataSync tasks with appropriate agents and verified source/destination paths.
Explanation
Correct Answer
B:DataSync is for transfers, while File Gateway exposes ongoing file shares. Read and write through the gateway after migration completes.
Incorrect Answers
A:Volume Gateway connects local block workloads with AWS-backed recovery storage. Use File Gateway for ongoing file protocol access to S3-backed objects. Read and write through the gateway after migration completes.
C:File Gateway exposes object-backed file shares to supported on-premises clients. Use File Gateway for ongoing file protocol access to S3-backed objects. Read and write through the gateway after migration completes.
D:DataSync accelerates supported transfers and validates file metadata/integrity. Use File Gateway for ongoing file protocol access to S3-backed objects. Read and write through the gateway after migration completes.
Question 489
A workload spends most CPU time compiling code and has modest memory needs. Which EC2 family is appropriate?
- Select compute-optimized EC2 instances sized to measured CPU demand.
- Select memory-optimized compute and retest peak resident memory requirements.
- Right-size toward compute-optimized instance shapes based on measured utilization.
- Choose memory-optimized EC2 instances with sufficient RAM headroom.
Explanation
Correct Answer
A:Compute-optimized families provide a higher CPU-to-memory ratio for processor-heavy workloads. Benchmark compilation throughput per dollar.
Incorrect Answers
B:Additional CPU capacity does not correct memory pressure when RAM is limiting. Select compute-optimized EC2 instances sized to measured CPU demand. Benchmark compilation throughput per dollar.
C:Family selection should match observed resource ratios, not raw instance size. Select compute-optimized EC2 instances sized to measured CPU demand. Benchmark compilation throughput per dollar.
D:Memory-optimized instances provide larger memory per vCPU for in-memory workloads. Select compute-optimized EC2 instances sized to measured CPU demand. Benchmark compilation throughput per dollar.
Question 490
An in-memory analytics service retains hundreds of gigabytes of working state. Which instance family should be evaluated?
- Choose memory-optimized EC2 instances with sufficient RAM headroom.
- Choose a compatible accelerated-computing GPU instance family.
- Select compute-optimized EC2 instances sized to measured CPU demand.
- Select memory-optimized compute and retest peak resident memory requirements.
Explanation
Correct Answer
A:Memory-optimized instances provide larger memory per vCPU for in-memory workloads. Measure memory pressure and swap activity.
Incorrect Answers
B:GPU instances provide device acceleration for supported parallel operations. Choose memory-optimized EC2 instances with sufficient RAM headroom. Measure memory pressure and swap activity.
C:Compute-optimized families provide a higher CPU-to-memory ratio for processor-heavy workloads. Choose memory-optimized EC2 instances with sufficient RAM headroom. Measure memory pressure and swap activity.
D:Additional CPU capacity does not correct memory pressure when RAM is limiting. Choose memory-optimized EC2 instances with sufficient RAM headroom. Measure memory pressure and swap activity.